HomeMy WebLinkAboutPS 05-99; Gregorio's; Sign Permits/Programs (PS)City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4600
PLANNIN
REC'D BY
DATE
SIGN FEE
SIGN PROGRAM FEE
RECEIPT NO.
PLICATION #."PS
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
NAME OF PROJECT: &• '
ADDRESS OF PROJECT:30Q
ASSESSOR PARCEL NUMBER:
RELATED PLANNING CASE NUMBER(S):
TYPE OF DEVELOPMENT:
(a) Residential
<£$/ Commercial
(c) Office/Industrial
(d) Hotel/Motel
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA
OS"
(e)
(f)
(g)
(h)
Service Station
Prof. Care
Theater
Govt/Church
(i) Public Park
(j) Produce Stand
(k) Nursery
(1) P-U/OSZone
Yes No
VILLAGE REDEVELOPMENT AREA YesE] No
SIGN ORDINANCE: YesQ
Specific Plan Number
Requires VR Approval
COASTAL ZONE:
Form 10 Revised 01/04
Yes
No
No
» » » » »
Page 1 of 3
EXISTING SIGNS:
TYPE
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project
Identity)
NUMBER SIGN AREA SIGN HEIGHT
PERMITS ISSUED FOR EXISTING SIGNS: Yes D No
PROPOSED PERMANENT SIGNS:
Date
TYPE
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding
(Project
Identity)
MAXIMUM
NUMBER
ALLOWED
1
NUMBER
PROPOSED
1
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
n*
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
PROPOSED TEMPORARY SIGNS:
TYPE
Construction
For Sale
Banner
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
Form 10 Revised 01/04 Page 2 of 3
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONTAGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
/I ft.
3V
O
O
n-
£TL.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
sq.ft.
OWNER
NAME (PRINT OR TYPE)
/U^" Itapf^y /l^jAi^if
MAILING ADDRESS
~200 (oJilfd ti\lttf, A. I0\
CITY AND STATE ZIP TELEPHONE
(Vilj , £ ^ 3 WO 8 >orc- 7>-006S
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT
ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE
Scr /|-/J*Uf
SIGNATURE DATE
APPLICANT
NAME (PRINT OR TYPE)
,)ory ^lJ0no
MAILING ADoAfiSS
fMS &/U ^ -If- 1*0
CITY AND STATE ZIP TELEPHONE
JW lOf/ftt) ^M fJ/?l S^ 5fcff/0°
I CERTIFY1 THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA-
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE
/~ ~ y^//
SIG#fATU#E DATE
PLANNER CHECK LIST:
I . Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: *v» In right-of-way
•J* In visibility triangle at comer
5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner:Date
Form 10 Revised 01/04 Page 3 of 3
Maa 09 2005 12:4SPM RCFttPROPERTY JtMRMHGEMENT 7607200042 p.l
ACF PROPERTY MANAGEMENT
Fax
To: John Hadaya From: Cathy Gardner-Samuel son
Fax: 858-569-1453 Fax: 760-720-0042
Phone: 858-569-1400 Phone: 760-720-0065
Date: 5/9/2005 Pages:
Subject: Suite 208, 300 Carlsbad Village Drive, Carlsbad, CA
The information contained in this facsimile message is privileged and confidential information
and intended only for the use of the individual or entity named above.
Notes:
This facsimile is intended to advise that Management has approved the signage
for Gregorio's to be installed at the above referenced address. Any building signage is
required to be tied into the suites electrical meter and not the common area electrical.
Further, this approval is contingent that all permits are pulled in accordance with the
City's guidelines and a copy submitted for our files prior to signage installation
Please do not hesitate to contact my office with any questions or concerns you
may have.
PMB #353, 300 Carlsbad Village Drive, Suite 108A, Carlsbad, CA 92008-2999
(760) 720-0065 Office (760) 720-0042 Fax cgardner(%acfbm.com
City of Carlsbad
1635 Faraday Avenue Carlsbad CA
Receipt
92008
Applicant: ALIONO JOEY
Description
PS050099
Amount
40.00
Receipt Number: R0051898
Transaction Date: 08/09/2005
Transaction ID: R0051898
Pay Type Method Description Amount
Payment Check 2376 40.00
Transaction Amount: 40.00
4312 08/09/05 0002 01 02
CGP 40 = 00
2'-10 "
JOB INFORMATION
GREGORIOS
300 CARLSBAD
VILLAGE DR.
CARLSBAD, CA
92008
SALESPERSON
JOHN HADAYA
DESIGNER
DAVID GREEN
SKETCH NO
GREGOR02
DATE
05-02-2005
REVISION DATES
NEW SINGLE FACED INTERNALLY ILLUMINATED FASCIA DISPLAY SCALE 3/4"=1 '-0"
USE STANDARD ALUMINUM CONSTRUCTION WITH MATTHEWS SATIN ACRYLIC POLYURETHANE FINISH.
"GREGORIO'S" USE PLEX FACED CHANNELS WITH THROUGH FACE ILLUMINATION,,
FACES USE #7328 WHITE PLEX WITH APPLIED POPPY RED VINYL OVERLAYS,
USE 3/4" RED TRIM CAR PAINT 5" DEEP RETURNS TO MATCH CARDINAL RED VINYL,
ILLUMINATE WITH CLEAR RED NEON AT 3-1/2" ON CENTER,
SYMBOL USE PLEX FACED CHANNELS WITH THROUGH FACE ILLUMINATION,
DECORATE FIRST SURFACE OF WHITE PLEX WITH CARDINAL RED AND EMERALD GREEN VINYL OVERLAYS,
USE 3/4" RED TRIM CAR PAINT 5" DEEP RETURNS TO MATCH CARDINAL RED VINYL,
ILLUMINATE WITH #4500 WHITE NEON AT 3-1/2" ON CENTER,
6" DEEP ALUMINUM BACKGROUND (RACEWAY) PAINT LIGHT GREY TO MATCH BUILDING COLOR,
INSTALL SO FACE OF RACEWAY IS FLUSH WITH FACE OF HEADER BOARD WITH FOUR 1/2" MOUNTING 30LTS
ALUMINUM CHANNEL
b I ANUAnU bLAoo bl AND
Fl FPTnn PIT0
NFfiN TIIPF
WFFP Hni FQ . /
/
\
/
' \
\\
n
/
(§i)
•0 0
•^
/-
5"RETURNS
6"ALUMINUM
WEATHERPROOF RACEWAY
INSTALLWITH3#10SCREWS
GTO-15WIRE
1/2" X 3-1/2" LAGS INTO EXPANSION SHIELDS
TWO(2)AT4'-0"ONCENTER
TRANSFORMER
DISCONNECTSWITCH
SECTION
SIGN TO BE UL APPROVED AND BEAR UL LABEL
PLEX FACED CHANNEL LETTERS
OVERSIZE RACEWAY MOUNT
VOLTAGE
120 VOLTS
PRIMARY ELECTRICAL
TO SIGN LOCATIONS IS TO BE
PROVIDED BY OTHERS.
A 20 AMP DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS
AND A GROUND RETURNING TO
THE PANE IS REQUIRED FOR
ALL INSTALLATIONS.
COLORS REPRESENTED
IN THIS DRAWING ARE FOR
PRESENTATION PURPOSES ONLY.
THEY WILL NOT MATCH YOUR
FINISHED PRODUCT PERFECTLY.
COLOR CALLOUTS ARE FOR A
MATCH AS CLOSE AS POSSIBLE.
THIS ORIGINAL DESIGN IS THE
SOLE PROPERTY OF ULTRASIGNS.
IT CANNOT BE REPRODUCED,
COPIED OR EXHIBITED, IN WHOLE
OR PART. WITHOUT FIRST
OBTAINING WRITTEN CONSENT
FROM ULTRASIGNS.
Page 1 of 2
CLIENT APPROVAL
TEL: 858-569-1400 FAX: 858-569-1453
9025 BALBOA AVENUE, STE 150
SAN DIEGO, CA 92123-1520
SECOND FLOOR
PROPOSED ELEVATION SCALE 3/8"=1'-0"
AS IS ELEVATION SCALE PROPORTIONATE
JOB INFORMATION
GREGORIOS
300 CARLSBAD
VILLAGE DR.
CARLSBAD, CA
92008
SALESPERSON
JOHN HADAYA
DESIGNER
DAVID GREEN
SKETCH NO
GREGOR02
DATE
05-02-2005
REVISION DATES
VOLTAGE
120 VOLTS
PRIMARY ELECTRICAL
TO SIGN LOCATIONS IS TO BE
PROVIDED BY OTHERS.
A 20 AMP DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS
AND A GROUND RETURNING TO
THE PANEL IS REQUIRED FOR
ALL INSTALLATIONS.
COLORS REPRESENTED
IN THIS DRAWING ARE FOR
PRESENTATION PURPOSES ONLY.
THEY WILL NOT MATCH YOUR
FINISHED PRODUCT PERFECTLY.
COLOR CALLOUTS ARE FOR A
MATCH AS CLOSE AS POSSIBLE.
THIS ORIGINAL DESIGN IS THE
SOLE PROPERTY OF ULTRASIGNS.
IT CANNOT BE REPRODUCED,
COPIED OR EXHIBITED, IN WHOLE
OR PART WITHOUT FIRST
OBTAINING WRITTEN CONSENT
FROM ULTRASIGNS.
Page 2 of 2
CLIENT APPROVAL
TEL: 858-569-1400 FAX: 858-569-1453
9025 BALBOA AVENUE, STE 150
SAN DIEGO, CA 92123-1520