Loading...
HomeMy WebLinkAboutPS 06-160; Comerica Bank; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760)602-4610 PLANNIN REC'D BY DATE fy SIGN FEE SIGN PROGRAM FEE RECEIPT NO. 'PLJCATim#PS REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: ^^i ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER: RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (^Residential /Mb)"TCommercial ^7 Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes D VILLAGE REDEVELOPMENT AREA YesQ SIGN ORDINANCE: YesQ COASTAL ZONE: YesQ (e) (f) (g) (h) Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone NO n NoD NO n NO Specific Plan Number Requires VR Approval «*««»«»*»««•»»»»»«•«» Form 10 Revised 12/04 Page 1 of4 EXISTING SIGNS: TYPE Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) NUMBER SIGN AREA SIGN HEIGHT PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: No Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED NUMBER PROPOSED / / MAXIMUM SIGN AREA 2 '(HWto*- - P PROPOSED SIGN AREA, 2 tfi 3/rfli' MAXIMUM SIGN HEIGHT / (* juf/' PROPOSED SIGN HEIGHT / jlh /fBf PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of 4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building Is P/L \- J I / Show all property lines [ ; i •, •, • S curb line •" Sight Visibility Sight Distance Requireir 1 1 how setbacks from all cu i 1 1 1 Street Name(s) 1 i ent irbs North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. Form 10 Revised 12/04 Page 3 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. sq. ft. OWNER APPLICANT NAME/PRINT OR TYP NAME (PRINT OR TYPE) CITY AND STATE ZIP TELEPHONE CITY.AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THATH AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: *»* In right-of-way *J» In visibility triangle at corner 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: Form 10 Revised 12/04 Page 4 of 4 Page 1 of 1 Warner LeMenager From: "Azad Golshani" <azad@ad-impact.net> To: "Warner LeMenager" <ilmigliore@earthlink.net> Sent: Wednesday, August 23, 2006 7:50 AM Subject: FW: Kelly Sign guidelines This is what I have from the landlord, please see below. Thanks, Azad From: Harve Filuk [mailto:hfiluk@allengroup.com] Sent: Tuesday, August 22, 2006 2:01 PM To: Azad Golshani Subject: RE: Kelly Sign guidelines Your proposed signage as submitted appears OK Harve Filuk The Allen Group 858-764-6814 From: Azad Golshani [mailto:azad@ad-impact.net] Sent: Tuesday, August 22, 2006 9:39 AM To: Harve Filuk Subject: RE: Kelly Sign guidelines Hi Harve, Please see attached proposed drawing for Comerica Bank for your review and approval. Thanks, Azad From: Harve Filuk [mailto:hfiluk@allengroup.com] Sent: Monday, July 03, 2006 10:16 AM To: Azad Golshani Subject: Kelly Sign guidelines Please keep in mind that the Lease does not allow for a major building sign. Monument and eye-brow over the entry is what is allowed. Harve Filuk The Allen Group 858-764-6814 8/23/2006 PLANNING( BUILDING ComericA Bank 1OOO AVIARA PARKWAY, SUITE 1O4 - CARLSBAD, CA Y^f^lJmi-f-i-.JV_-/ /_/ ljs»<iS*i* —,->»-• IT—' -^ 1- - REV #OO OO-OO-OO L E G E N D NA NEW RB RC RF RL RO RP RR RS RSL K?l <§-c NOTE = NO ACTION = NEW PRODUCT = REFURBISH = REMOVE CABINET = REFACE = REMOVE & RELOCATE = REMOVE ONLY = REPAINT = REMOVE & REPLACE = REMOVE - SAVE SIGN = REMOVE - SAVE LOGO PRIMARY SIGN | DIRECTIONAL SIGNS — PROPERTY LINE ALL EXISTING SIGNAGE W/ THE "RO" PREFIX TO BE REMOVED AND THE WALL BEHIND IT TO BE REPAIRED AS NECESSARY. NORTH SITE PLAN NOT TO SCALE DATE 07-05-06 SCALEc O * *n 3 Shown CO BRANCH* PROJECT NAME Comerica Bank ADDRESS " 1 000 AVIARA PARKWAY, SUITE 104 ^ CITY/STATE 1 CARLSBAD, CA CLIENT APPROVAL PROPERTY OWNER APPROVAL NO.DATE REVISION ADIMPACT CORPORATE SIGNAGE 19772 MacArthur Blvd. Suite 110 Irvine, CA 92612 (949) 476-0015 fax. (949) 476-0029 CS SEE SEPARATE STRUCTURAL CALCULATION AND DETAIL ATTACHMENT. STRUCTURAL TECHNOLOGY CONSULTANTS, INC. - V006-251 LEGEND NA = NO ACTION N EW = NEW PRODUCT RB = REFURBISH RC = REMOVE CABINET RF = REFACE RL = REMOVE & RELOCATE RO = REMOVE ONLY RP = REPAINT RR = REMOVE & REPLACE RS = REMOVE - SAVE SIGN RSL = REMOVE - SAVE LOGO PRIMARY SIGN DIRECTIONAL SIGNS PROPERTY LINE NOTE: ALL EXISTING SIGNAGE W/ THE "RO" PREFIX TO BE REMOVED AND THE WALL BEHIND IT TO BE REPAIRED AS NECESSARY. _L PRIMARY ELECTRICAL TO SIGN 3CATIONS TO BE SUPPLIED NORTH FLOOR PLAN NTS O•n -o DATE PROJECT NAME S 07-05-06 Comerica Bank i SCALE ADDRESS 3 Shown : 1000 AVIARA PARKWAY, SUITE 104 BRANCH* CITY/STATE CARLSBAD, CA CLIENT APPROVAL PROPERTY OWNER APPROVAL NO. DATE REVISION ADIMPACT CORPORATE SIGNAGE 19772 Mac Arthur Blvd. Suite 110 Irvine, CA 92612 (949) 476-0015 fax. (949) 476-0029 s CO ComencA Bank NEW F.C.O. LETTERS 3" = 1'-0"2.0 Sq. SPECIFICATIONS: MANUFACTURE AND INSTALL NEW 1/4" THICK FLAT CUT OUT ACRYLIC LETTERS. NON-ILLUMINATED. STUD MOUNTED. COMERICABANK: 1/4" ACRYLIC PAINTED BLACK. 1/4" F.C.O. ACRYLIC LTRS. METAL STUD ATTACHED TO WALL WITH EPOXY OR SILICONS NOTE: FIELD VERIFY DIMENSION PRIOR TO CONSTRUCTION FLAT CUT OUT LETTERS ATTACHMENT DETAIL CO g DATE & 07-05-06z i ''SCALE * ; Shown BRANCH# PROJECT NAME Comerica Bank ADDRESS 1000 AVIARA PARKWAY, SUITE 104 CITY/STATE CARLSBAD, CA CUENT APPROVAL PROPERTY OWNER APPROVAL NO. DATE REVISION ADIMPACT CORPORATE SIGN AGE 19772 MacArthur Blvd. Suite 110 Irvine, CA 92612 (949) 476-0015 fax. (949) 476-0029 EQ T T EQ ComencA Bank SOUTH ELEVATION Scale: 1/16"=1' I I Proposed Location Scale: 1/2"=1' NOTE: FIELD VERIFY DIMENSION PRIOR TO CONSTRUCTION O §—i-i m~ » CD DATE 07-05-06 SCALE Shown BRANCH * PROJECT NAME Comerica Bank ADDRESS 1000 AVIARA PARKWAY, SUITE 104 CITY/STATE CARLSBAD, CA CLIENT APPROVAL PROPERTY OWNER APPROVAL NO. DATE REVISION 19772 MacArthur Blvd. Suite 110 Irvine, CA 92612 (949) 476-0015 fax. (949) 476-0029 5'-7 1/4" Comenq\ Bank 0 (2) NEW F.C.O. LETTERS _ 1-1/2" = 1'-0" SPECIFICATIONS: MANUFACTURE AND INSTALL (2) NEW 1/«" THICK FLAT CUT OUT ACRYLIC LETTERS. NON-ILLUMINATED. STUD MOUNTED. COMERICABANK: 1/4M ACRYLIC PAINTED BLACK. o CD 8'-4" Comeno\ Bank MONUMENT SIGN 3/4" = 1'- CD g DATE 8 07-05-06 i SCALE 3 ; Shown BRANCH# PROJECT NAME Comerica Bank ADDRESS 1000 AVIARA PARKWAY, SUITE 104 CITY/STATE CARLSBAD,CA CLIENT APPROVAL PROPERTY OWNER APPROVAL NO. DATE REVISION 19772 MacArthur Blvd. Suite 110 Irvine, CA 92612 (949)476-0015 fax. (949) 476-0029