Loading...
HomeMy WebLinkAboutPS 06-193; Ken Grody Ford; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION # REC'D BY DATE SIGN FEE jf SIGN PROGRAM FEE RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department AH plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 pan. Average processing time: 2 weeks NAME OF PROJECT: _ \r\fJT\. (^]£Q(j.U ADDRESS OF PROJECT: 5555 . )gi Co/.\Sbcxd ASSESSOR PARCEL NUMBER: '2.1\~ D6& - (e) (f) (g) (h) RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: Residential I Commercial (c) Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA VILLAGE REDEVELOPMENT AREA YesQ SIGN ORDINANCE: YesQ Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone COASTAL ZONE:Ye: No H] Specific Plan Number . No |£f Requires VR Approval No D NoQ Form 10 Revised 12/04 Page 1 of4 EXISTING SIGNS: TYPE Pole Monument Wall S!u«iw>n/l«/i Directional Canopy Freestanding (Project Identity) NUMBER & v SIGNAREA SIGN HEIGHT #• 'Ft'3"x 13._ 23'9*>r I' PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: NoQ Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED NUMBER PROPOSED JT\ MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT •gu'V'^TJ^ AI'II" y /«/'9 PROPOSED TEMPORARY SIGNS: TYPE rv».c.«OT..~4:.~~.** VxIMiaU UtUUll - - For Sale** Banner MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Showbuilding/s - P/L i 4 v / ^ — /' Show all property lines j /Jr/JLi • f \ f / f s curb line • Sight Visibility 1 Sight Distance Requireir 1 1 1 1 'how setbacks from all cu 1 1 1 Street Name(s) 1 i ent jrbs North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. Form 10 Revised 12/04 Page 3 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. $.*)£ c^\d ^L £11 O~j\d 5*>c sq. ft. 9 / sq. ft. sq.ft. ??> sq.ft. sq.ft. OWNER NAME (PRINT OR TYPE) V4? r\ (r)Voduy Pore! MAILING ADDRESS1 6556 Hvseorkl PvOr'te. CITY AND STATE ZIP TELEPHONE Cci * \sbad C/ft I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE APPLICANT NAME (PRINT OR TYPE) , — . . _ j . ' VrxoCc o o i cw\ ( onsVucri an Xr\c. MAILING ADDRESS I ^3^9 OcxV \<r\ol\ ^ocxd CITY AND STATE ZIP TELEPHONE I CERTIFY-^HAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. ^^^jP(?LOv<^ /YU^X^oeXJr //3%lfofi: SIGNATURE/rA fl DATE f ' PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •!» In right-of-way •t* In visibility triangle at corner 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved rou|e-eppy to Daja_Entry Date: ^< /141C>LAPPROVED: Planner: Form 10 Revised 12/04 Page 4 of 4 7/16" -W-5- 17'-79/16" 14'-9 6'-3 1/4' 23'-9" BEFORE F19-119 P20 AFTER F-73 P20 Account FORD Protect Title FO Ken Gmdy Sign Comp Scale 1:64 Date Created 19 July OS • OX-OOOXrX Drawn By 1. Allington IP Rep. J Bullard Approved By Date Revised All ideas, plans or arrangements indicated in this drawing are copyrighted and owned by ImagePoint and shall not be reproduced, used by or disclosed to any person, firm or corporation for any purpose whatsoever without wntten " PO Box 59043 ImaeroPnint Knoxville, TN 37950-9043imageruini, M00,444_7446 P wwwjmagepoint.com pg 2 of 2 ^^^^^^^^^^^^^^^^^^^^^m^^^^^^^^^^^_ 5555 Poseo Del Norte Carlsbad CA F71102 STREET STATE F-60 P16 "' [_10'-B- l-S THBIS ftN ORaPttL IWU8USHEO DWMHG DESENEO Wmane SIGN cownjaioN, we. n is SUBMTIED ran YOUR FtRSCWW- USE IN CONJUNCTION WTH A PROJECT BEMG PUWKEO TORYOU Bf WOBC SIGN CONSTRUCTION, INC. IT IS NOT TO BE SHOWN TO «N«M OUTSIDE YOUR ORGANZRTION NOR IS IT TO BE REPRODUCED. COPIED OR EIHBITEOINANYFASHCH II PACIFIC SIGN CONSTRUCTION, INC. "' ~ - (858)486-800612339 Oak Knoll Rd. Poway, Ca. 92064 Lic.#447724 JOB TITLE Ken Grody Ford ADDRESS 5555 Paseo Del Norte, Carlsbad, Ca. SALES Roy Flahive DRAWING BY KB.W FONT CUSTOMERAPPROVAL DATE / / REVISED SHEET w OF1 * 1 AS NOTED DATE 9/15/06 #Site Plan \ EXPIRES DEC 3 1 2007 Project New Ford Sign Values from Wind Pressure Worksheet Job No. 99 4775 wsb, wind: MODEL: F60P16 wa, wind: Date: 5/9/00 we, wind: wd, wind: we. wind: wf.wind: wg, wind: Pa psfrtt: 300 Soil Bearing Capacity psf: 3000 Fc psi: 2500 SIGN DIMENSIONS, ft:Total Height Col.Ht Col.Loc. 20.74 15.06 6.71 h c e FOOTING DIMENSIONS, ft; FtgWidth FtgThick FtgUn 4.00 4.00 8.00 f t fl Wind Forces on Sign Box, kips: Wf. sign box 1.666 Total 1.666 \ Wind Forces on Column Cover, kips: Wac. column 40-50 ft 0.000 Wcc. column 30-40 ft 0.000 Wdc. column 25-30 ft 0.000 Wee, column 20-25 ft 0.000 Wfc, column 15-20 ft 0.005 Wgc. column 0-15 ft 1.209 Total 1.214 W. Total Wind Force: 2.88 27.77 34.44 32.86 30.96 29.70 28.44 26.86 SECTION PR( Length 13.42 1 Overt) 0.67 o psf @ sign box psf40-50ft psf30-40ft psf 25-30 ft psf 20-25 ft psf 15-20 ft psf 0-15 ft JPERTES: Depth 5.68 d PedWidth 4.50 P Moment Am (ft) 17.90 Moment Arm (ft) 0.00 0.00 0.00 0.00 15.03 7.50 Cover Plato Dimensions: COLUMN: TS8x8x3/8 STEEL Fy: 48 Thickness of one n Cover Plate (In): Cover Plate Width (in): 0 Tube Depth (hi): 8 Tube Width (hi): 8 Tube Thickness (in): 0.375 Moment of Inertia of .^ann Total Section (in«4) 106-°° WidthofColCover(ft): 3 V. . J(lnM> 17000of tub* only: '""" A O*2| of tube only: WT(lbsm) of tub. only: 37'69 Inertia of Tube (ln*4): 106 Sign Box are* (ft*2): 60 Total Column Wt (Ibs/ft): Sx(inA3): 37.69 26.50 Wind Moments at Base From Sign Box, ft-k: Mf. Sign box 29.823 Wind Moments at Base From Column Cover, ft-k: Mac, column 40-50 ft 0.000 Mcc, column 30-40 ft 0.000 Mdc. column 25-30 ft 0.000 Mac, column 20-25 ft 0.000 Mfc, column 15-20 ft 0.077 Mgc, column 0-15 ft 9.064 Total 9.141 M.Total Wind Moment (ft-k) 38.969 Torque at Base From Wind, ft-k: Tf, Total Torque (ft-k) 4.47 STRESS, ksi: fw, wind moment ft, torsion: fv, shear fp, princ. stress, ksi: Fa. allowable stress, ksi: RECTANGULAR SPREAD FOOTING: P. vertical load, kips: Mo, overturn, ft-kips: Mr. resistive, ft-kips: F.S., factor of safely: Ms. soil reaction, ft-kips: e', ecentricity. ft ps, soil pressure, ksf: Mu, ultimate, ft-kips/ft: fb. ultimate, psi: V. allowable kip/ft: Vu. ultimate, kips/ft Flexural Steel in.2/ft. CIRCULAR CAISSON: Mot, overturn, ft-kips: Mpr, resistive, ft-kips: a'.ft: Mu, max. mom., ft-kips: As. area of steel, inA2: As, provided. inA2: Vertical Bars: use* Stirrup Size: use tf 17.65 =12'MySx 1.26 =(12*T*L/2)y 0.26 =W/A 17.78 =(fw)/2+sqrt((fw/2)A2+(ft+fv)A2) 40.38 =1.33'0.66'Fy fp < Fa, O.K. 22.62 =ntrO. 15+ni'o-O. 1+C(d+(h-d-cX2)-0.012+c'WT 52.41 =M+W*(t+o) 111.76 =P"fl/2+Pa'p-(tto)A3/6000*Pa't"3'(f-p)/6000' 1.3 =Mr/Mo 31.14 =Mo-0.3-(f-p)'(t)A3/6-0.3V(t+o)A3/6 1.38 =Ms/P 1.44 =2P/(3'f-(fl*-e')) 1.67 =1.3'(ps-0.15't)'((<H>y2)A2/2 F.S.>1.5 94.3280387 =P'(fl/2)+W*(t/3) O.K. k. kern, ft fl/6 = 1.33 OK 4.34 =6000'Mu/(12t)*2 fb<3.25*sqrt fc, no reinforcing req'd 48.96 =.85'2sqrt(fc)(144't)/1000 0.95 =1.3'(ps-0.15-t)'(fl-p)/2 O.K. 0.01 •=((4.5(d-4)HSQRT(4.5(d-4)H3.32M-rc/1000)A2)/3.32TcQuOO) D, diameter, ft = 3.50 38.97 = Mom.at Surface Le, embedment, ft =10.50 Lc, tens ox 1 10.24 = See UBC W 2907.g.2; Shape Factor= 0.636 N.A. N.A. 50.66 =1.3'Mot 0.94 =3*Mu"12/(0.9"60"(12"D"6/7)) < 2.48 5 #5 Vertical Bars 3 #3 ties @ 16 inches o.c. maximum OK 1.70 Job Name Job Number Engineer Date Sign Identification Tube Width (in) : Tube Depth (in) : Tube Thickness (in) : Cover Plate Width (in) : 2over Plate Thickness (in) : M.O.I. Of Tube (inA4) : Weight of Tube (Ibs/ft) : Modulus of Elasticity(psi) 29000000 E Moment of Inertia of Total Section (inM) 106.00 I Mass of Sign Box m Mass of Column mb New Ford Sign 99 4775 mst 5/9/00 F60P16 8 8 0.375 0 0 106 37.69 Wt. Of Sign Box (psf) 12 Wsb Wt. Of Total Section (Ibs/ft) 37.69 We 1.86 1.75 3.203 | Area of Sign Box (ftA2) 60 Asb Height to Midpoint of Sign Box (ft) 17.9 L JO.K. Job Name Job Number Identification Engineer Date New Ford Sign 99 4775 F60P16 mst 5/9/00 Height to Midpoint of Sign Box, z (ft) 17.90 50 40 30 25 20 0-15 *110 mph=Standard Wind Velocity *150 mph=High Wind Velocity Velocity Pressure Coefficient •Wind Velocity (mph) Table 6-3 V Kz 110 0.879 110 1.09 110 1.04 110 0.98 110 0.94 110 0.9 110 0.85 Width of Sign Box Height of Sign Box M N 13.42 5.68 From ASCE 7-95 Table C6-« C V 0.2 I " 500 e 0.2 Factors from ASCE 7-95 Topographic Importance Factor Factor Fig 6-2 Table 6-2 Kzt 1 1 1 1 1 1 1 1 1 Iz Lz Q qz/Kz Force Coefficient Table 6-8 Cf 1.2 1.2 1.2 1.2 1.2 1.2 1.2 0.222 442.423 0.959 30.976 Eq.C6-6 ASCE 7-95 Eq. C6-8 ASCE 7-95 Eq. C6-7 ASCE 7-95 Eq. 6-1 ASCE 7-95 Natural Frequency (Hz) 3.203 0.85 Rigid Structure _Section 6.6.1 ASCE 7-95 Exposure C 17.900 40-50ft 30-40ft 25-30ft 20-25ft 15-20 ft 0-15 ft i FILENAME: ASDPLATE.XLS ' . AXIAL LOADED COLUMN WITH A LARGE ECCENTRICITY IDENTITY: DATE: 7/17/00 New Ford Sign F60P16 Axial Load 75% of TotalWind Moment about X-Axis Total Column Depth Compressive Strength of Concrete Yield Stress of Plate Steel Nominal Diameter of Bolts Number of Bolts in Tension ASTM Designation of Bolts Distance From Bolt To Plate Edge Dist. from center of bolt to plate center Sumofalld*2: Total No. of Bolts in Base Plate.N Plate Dim. in Y-Direction Plate Dim. in X-Direction Pedestal Dimension in Y-Direction Pedestal Dimension in X-Direction P (kips) : MX (ft-kips): d (inch) : fc (ksi): Fy (ksi) : db (inch) : (307, 325, or 490) : g (inch) : d (inch): N (inch): B (inch): (ft): (ft): 1.29 29.23 8.00 2.50 36.00 1.13 3 307 2.00 7.21 280 6 16.00 12.00 2.75 4.50 Y-Direction = Parallel to Force X-Direction = Perpendicular to Force Kem Eccentricity Large Eccentricity k (inch) : e (inch): 2.67 272.38 YES Plate Area Concrete Bearing Surface Area .35*fc*SQRT(A2/A1) .7*fc Allowable Bearing Stress A1 (sq. in.) : A2 (sq. in.) : Fp1 (ksi): Fp2 (ksi) : Fp (ksi) : 192.00 1782.00 2.67 1.75 1.75 Applied Concrete Bearing Stress Area of Bolts in Tension Plate Region In Compression Summation Of Force In Anchor Bolts Cantilever Dimension Plate Thickness Plate Thickness Plate Thickness fp (ksi): As (sq. in.) : A (inch) : T (kips) : X (inch) : tension side tp (inch) : compression side tp (inch) : tp (inch) : 0.79 2.98 6.36 28.88 4.00 0.88 0.90 0.90 OK Development Length for A307 Anchor Bolts Minimum Embedment: 12 X diameter (inch): 13.5 GOVERNS Concrete Cone (inch) - 9-59 Edge distance in Y-direction (inch): 10.50 O.K. Edge distance in X-direction (inch): 23 O.K. NOTE: EDGE DISTANCE IN BOTH DIRECTIONS IS IDENTICAL Check of Combined Tension, Shear, and Torsion on Bolts: Allowable tension in ea. Bolt, Ps(kips): 19.88 =20ksi*area of A307 bolt Allowable shear in ea. Bolt, Vs (kips): 9.94 =10ksi*area of A307 bolt Torsional force on ea. Bolt.Vt (kips): 1.38 =(T*d)/(sum of all dA2) Shear force from wind, Vv (kips): 0.48 = W / N Total Tension in ea. Bolt, Pu (kips): 9.63 =T/2 Total Shear in ea. Bolt, Vu (kips): 1.86 =Vt + Vv (Pu/Ps)A2+(Vu/1.33*Vs)A2 0.25 BOLTS O.K.