Loading...
HomeMy WebLinkAboutPS 06-198; Hoehn Honda; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION # REC'DDATE SIGN FEE SIGN PROG RECEIPT NO. cS REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: z^--Kl .rfrQ^ D> As _ ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER:V 00 RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential /{rJp Commercial (c) Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes D VILLAGE REDEVELOPMENT AREA YesQ SIGN ORDINANCE: YesQ COASTAL ZONE: YesQ (e) (f) (g) (h) Service Station Prof. Care Theater Govt/Church (if Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone No No No No Specific Plan Number . Requires VR Approval »•«»«» Form 10 Revised 12/04 Page 1 of 4 EXISTING SIGNS: TYPE ;r .Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) NUMBER 3 2. SIGN AREA ! - ^,-7^ tzf \\ tf A %i ! §IGN HEIGHT 5" */ ^vA t ^( > ,i f^-L, .3 PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: NoQ Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED NUMBER PROPOSED 1 MAXIMUM SIGN AREA PROPOSED SIGN AREA &.2&jtf MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT t «r ff-« PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT t PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding sighs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of 4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building /s P/L \-J.i ;i • Show all property lines j J i • i • • ••• S curb line •* • Sight Visibility 1 i Sight Distance Requires 1 1 1 how setbacks from all cv l 1 1 1 Street Name(s) 1 i ent irbs North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any •„- pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. -*s**- « « • Form 10 Revised 12/04 Page 3 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE '' EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. OWNER NAME (PRINT OR TYPE) e^B \(\e^^^c^, MAILING ADDRESS CITY AND STATE ZIP TELEPHONE ^y^i^'L^'^^O ^*4c <st/2j5>£><!p> I CERTIFY THAT 1 AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE APPLICANT NAME (PRINT OR TYPE) -^p=^^\ fx3^VTT' MAILING ADDRESS CITY AND STATE ZIP TELEPHONE ^ -izi-^biz. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE ' PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: <• In right-of-way <• In visibility triangle at corner 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 67 When approved route copy to Data Entry APPROVED: Planner:Dates- Form 10 Revised 12/04 Page 4 of 4 19. 2pp6JK 1:58PM,. PETROLEUM 3 SOUTH373; SEP-16-06 10:53;No. 0434 :P. 1 1/1 o. 2ui/D o:j5flM rtiKULtUM 3 SjQUIH No. 0256 P. 2 Sept 6,2006 Hoehn Honda Bob Hoehn 5454 Paseo Del Norte Carlsbad, CA 92008 To whom it may concern, This letter authorizes Certified Sign, of Homeland, CA,, to be Hoohn Honda's contractor for its upcoming purchase and installation of a new exterior Certified Used Cars pole sign. Sincerely, Bob Hoehn Principal Owner - Hoehn Honda ! I Non-illuminated "Entance Signs" 1 _115' loehn Honda 36" Dealer Name Letters SIGN PEIXMIT NO. PS Account Honda Pre/ectT7tfe HO Hoehn Elevation Scale Site Plan 1:750 Sign 1:48 Date Created 08 June 06 Drawn By J. Allington IP Rep. D. Wares Approved By Date Revised 06-0600 Pglofl All ideas, plans or arrangements indicated in this drawing are copyrighted and owned by ImagePoint and shall not be reproduced, used by or disclosed to any person, firm or corporation for any purpose whatsoever without written permission of ImagePoint. ImagePoint, PO Box 59043 KnoxvilleJN 37950-9043 1-800-444-7446 www.imagepoint.com • CONTRACTOR - IMA6EPOINT • CA. STATE BUILDING CODE « 1O MPH WIND SPEED • Cq = I.4 • (2) POLES (2) FOUNDATIONS SI6N CABINET AND CONNECTION BY OTHERS 6'-0" NOTE: SEE SIGN DRAWINGS FOR ADDITIONAL DIMENSIONS AND DETAILS. VERIFY ALL DIMENSIONS. Job Information o ih OPEN rV n fi •HSS b 5/&" DIA. x .2&0" WALL «5 BAR Vt3?T. AS REQ'D (6) «5 SK T-« (4) «5 LK T+B •CONCRETE PEDESTAL I2"xl2"xq" C-RADE 3'-0" FRONT VIEH 3'-O" LOUIS J. CORTINA, P.E. •SIGN ENGINEERING •CIVIL *STRUCTURAL 299 WEISGARBER RD. KNOXVILLE. TENNESSEE 37919 PHONE FAX 665-584-0999 865-584-5213 FRONT VIEH SPREAD FOUNDATION PROJECT: Carlsbad, CA Comm * Name Location Date Designer Code 06001.119 Hoehn Honda Carlsbad. CA 4/11/2006 F.C.M.(Approvad by | California Slate Building Code Input Parameters Louis J. Cortina, P.E. 299 N. Weisgarber Road Knoxville, TN 37909 Phone: (865) 584-0999 Fax: (865)584-5213 wftW.sign-engineer.com www.michaeifaradyinc.com Wind Load Calculations (per 1997 Uniform Building Code) Section/ Sign Face" 1 P; 2 P, 3 H 4 W: S W. e W. 7 p e f7 9 P, 10 P, Width ((9 2.60 f . 4.00 ' .3.75 „: 0.60 •(. 0.50 0.00 ' , 0.00 i . 9.00 : 0.00 " ~ 0.00~ „ Height (ft) ,.0.60v ^. J-67 , :0.50 -- 8 JO ' OJ>0 . 0.00 .,0.00 , 0.00 0.00 ; •::<• 0.00 „. Area (sq ft) 1.25 10.68 1.88 4.00 0.00 0.00 0.00 0.00 0.00 0.00 Sectbn Weight (kips) 0.01 0.11 0.00 0.04 0.00 0.00 0.00 0.00 0.00 0.00 Height Above Grade (ft) 11.67 11.17 8.50 8.00 0.00 0.00 0.00 0.00 0.00 0.00 C. 1.06 1.06 1.06 1.06 1.06 1.06 1.06 1.06 1.06 1.06 c, 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 qs(psf) 12.6 12.6 12.6 12.6 12.6 12.6 12.6 12.6 12.6 12.6 P(psf)* 18.70 18.70 18.70 18.70 18.70 18.70 18.70 18.70 18.70 18.70 F(kips) 0.02 0.20 0.04 0.07 0.00 0.00 0.00 0.00 0.00 0.00 Centroid (ft) 11.42 9.84 8.25 4.00 0.00 0.00 0.00 0.00 0.00 0.00 M(k-fl) 0.27 1.96 0.29 0.30 0.00 0.00 0.00 0.00 000 0.00 * Uncheck box if section is pole only Pole Size Calculations * Far (2) pole signs, Cq is reduced by 1/2 to account for wind load applied to (2) poles. Augered Footing Calculations Diameter < Allow. Press.j V of Poles 0 ,. ft JOO ' psf/ft . 1 ; Augered Footing Design Moment Force AH S1 A Req'd Depth 2.82 0.33 8.47 0.00 SDIVAJ! SOMO! k-ft kips ft Stiffness Analysis CBnping Ratio 0.035 Steel Base Pole I, 26.4 in4 Natural Freq. 6.8 cycles/second Stiffness OK Spread Footing Calculations Assumed Cap. mUgM psf El:l E 1.5:1 E2:l Spread Footingjpesign pj Manual Design Values Depth '"* V"" "ft Length | 6 ft VWdth ___ J v>ft Footing Weight Sign Weight VRM HRM RM OTM 8.10 0.37 25.40 2.40 27.80 3.82 e 0.45 Maximum SoilPressun I™, 0.68 Overtiming Ratios Volume 7.28 Shallow 6.65 kips kips k-fi k-fl k-ft k-ft ft <1ksf >1S >1.5 Augered Footing Size Diameter Depth Volume cu.yds. Spread Footing Size Depth Length Width N&lume 3 6 3 2.00 ft ft ft cu.yds. Sign Specifications Refer to Sign Company's drawing(s) for more details. designs .detailing,fabrication and construction shall conform to: California State Building Code AC 1301-89 AISC American Welding Society Local Building Codes & Ordinances Concrete: 3000PSI@28days HSS Round Section: ASTM A500 Grade B (Fy=42 ksi) HSS Square/Rectangular Section: ASTM A500 Grade B(Fy=46ksi) Anchor Bolts: F1554 Grade 36 U.N.O. (alternates Grade 55 and 105) Connection Bolts: A325 Steel Angles .Channels, Structural Shapes and Plates ASTM A36 Reinforcing Grade 60 Provide a minimum of three inches of concrete cover over embedded steel. The contractor (Installer) is responsible for the means & methods of construction in regards to jobsite safety. No field heating to bend steel shall be allowed without the Engineer's approval. Voiding Electrodes E70XX Calculated Soil Bearing Pressure 682 psf Assumed Horizontal (Passive Pressure) assumed at 200 PSF/Footof Depth. All footings shall bear on firm undisturbed residual soil and/or engineered earth fillcommpacted to 98% of its maximum dry density as per ASTM D 698-70 (standard proctor) unless noted otherwise. The soil bearing capacity is to be verified by a geo- technical engineer prior to construction, if allowable bearing and/or lateral pressure is less than the above assumed and/or calculated pressures, the engineer should be contacted for re-evaluation. Excavation shall be free of loose soil before pouring concrete. Welders shall be certified for type of welding. Adequately brace pole(s) until concrete has set up for 14 days. Grout under base plates with non-shrink grout. This Engineer does not warrant the accuracy of dimensions furnished by others. All exposed steel shall be painted with an enamel paint to inhibit corrosion. This design is for the indicated address only, and should not be used at other locations withoutwritten permission of the engineer. Design of details and structural members notshown, byothers. I COMM. NO. \O6OO\.\\e\ I DATE: O4/I4/O6 DRAWING TITLE: Hoehn Honda DRAWING NO. EDO Version: 1.2 2'-8" 3" WHITE COPY BLUE BACKGROUND CUSTOM, FONT/-PMS 285C -4 1/2" WHITE COPY GILL SANS BOLD 7'-6" PAINT WHITE IN FIELD 1'-5" 3'-Q" -3" 3"0 HAND HOLE ELECTRICAL BOX 'BY INSTALLER PLASTI-LINEJNC 623 E. EMORY ROAD, P.O.BOX 59043,KNOXVILLEJN 37950 FOUNDATION SPECIFICATION FOR: USE OR REUSE OF THIS DOCUMENT FOR OTHER LOCATIONS IS STRICTLY PROHIBITED WITHOUT APPROVAL OF ENGINEER. SIGN: 3x8 HONDA PYLONS HEIGHT: 1 1'8" WINDLOAD: 80 & 1 10 MPH 1. 2. CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS. CONCRETE SHALL BE READY MIXED AND DESIGNED TO DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS. 3. REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE 60 WITH DEFORMATIONS IN CONFORMING WITH ASTM A-305. 4. THE ENGINEER HAS NOT INSPECTED THE SITE. IT SHALL BE THE OWNER'S OR HIS AGENT'S RESPONSIBILTY. 5. SOIL CAPACITY: A. A MINIMUM SOIL CAPACITY OF 2000 PSF (VERTICAL) HAS BEEN USED IN THE FOUNDATION DESIGN. B. A LATERAL SOIL RESISTANCE OF 150 PSF/FT OF DEPTH HAS BEEN USED IN THE FOUNDATION DESIGN. 6. THESE DRAWINGS CONTAIN INSTALLS FOR BLOCK, VERTICAL SLAB & CAISSON FOUNDATIONS. 1 SIGN SPECFICATIONS LAMPS: (8) F36T12/CW/HO P/N: 067407 2. BALLASTS: (2) JEFFERSON 256-448-100 P/N:00-10-002-4296 3. VOLTAGE: 120 V, 60 HZ 4. FACE: BLUE ACRYSTEEL 5. SERVICE: REMOVE TOP CAP P/N: 00-00-005-0741 PLASTI-LI P.O. BOX 59043 KNOXVILLE, TN 37950-9043 D 4/3/03 DJB Dl: UPDATED GRAPHICS PER ECN 7161 02: ADDED FONT NOTE D3: ADDED PMS COLOR DSGNR: JHP DWG.BY: JHP CH'K BY: C 2/20/0 DJB 8567 C-ADDED NOTE: PAINT COLUMNS WITH SUPPLIED PAINT.SCALE: NONE DATE: 5-28-97 DATE: B 2-17-99 VAL 7326 B1-ADDED VARIABLE DIMENSION "D". B2-PART WAS 11-33-992-0440 DESCRIPTION: A 2-13-98 VAL 6653 UPDATED GRAPHICS TO ADD SPACE BETWEEN UNDERSCORE LINE AND LETTERS TO ALLOW ROOM FOR DECAL.3X8 INSTALLS CUSTOMER: REV DATE INIT ECN DESCRIPTION OE CHANGE HONDA PROPERTY OF PLASTI-LINEJNC NOT TO BE DUPLICATED. UNSPECIFIED RADII = .015 R TOLERANCES: ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED .XX = ±.03 .XXX = ±.015 ANGLES = ±r SHT OF DRAWING NUMBER: EDO Version: 1.2 GRADE 6" PIPE W/ .28 WALL -5' -5'-6 5/8" PEDESTAL \ T :_ i. TOP OF COLUMN ELEC. ACCESS r Y ELEC. BOX BY INSTALLER WELD DETAIL FRONT VIEW SIDE VIEW NSTALLATION TRUCTION SEE "INSTALLATION FIELD MANUAL' INSTALLATION STANDARDS. #A15552 FOR FOUNDATION AND 1. 2. 3. 4. 5. 6. 7. 8. 9. 10 EXCAVATE FOR FOUNDATION AND ELECT,LEVEL,AND PLUMB COLUMN. POUR CONCRETE AND ALLOW 7 DAYS FOR CONCRETE TO CURE. BE SURE THE CONDUIT IS IN PLACE BEFORE POURING CONCRETE. REMOVE ALL EXCAVATED FILL FROM SITE. UNCRATE THE SIGN AND TEST LIGHT. LIFT THE SIGN IN PLACE AND WELD TO COLUMN (SEE WELD DETAIL). REPLACE EYEBOLTS WITH BOLTS MAKE FINAL ELECTRICAL CONNECTION & TEST LIGHT. PAINT COLUMNS WITH SUPPLIED PAINT. CLEAN SITE OF ALL DEBRIS. , INSTALLATION TO CONFORM TO N.E.C. AND ANY OTHER APPLICABLE LOCAL CODES. PLUG WELD PLATE TO COLUMN (FILL IN COMPLETE TYP 4 SIDES k: uTYP CLEARANCE WELD DETAIL (FACES & FACE MOUNTING HARDWARE REMOVED FOR CLARITY) PEDESTAL WIDTH PEDESTAL LENGTH PEDESTAL THICKNESS I'O" I'D" 0'9" BLOCK FOUNDATION 80 MPH COLUMN SET: 11-33-992-0430 110 MPH COLUMN SET: 11-33-992-0430 SLAB WIDTH DIM A SLAB LENGTH DIM B SLAB DEPTH DIM C CONCRETE EACH EDUNDATIDN EXCAVATION EACH EDUNDATIDN 80 MPH 2'6" 3'9" 3'0" 1,048 YDS 1,215 YDS 110 MPH 2'6" 5'0" 3'0" 1,395 YDS 1,620 YDS pi A c T i i I M rr LMO II LI IN L_ P.O. BOX 59043 KNOXVILLE, TN 37950-9043 DSGNR:JHP DWG.BY: JHP SCALE: NONE DATE: 5-28-97 DATE CH'K BY: DESCRIPTION:3X8 INSTALLS CUSTOMER:HONDA PROPERTY OF PLASTI-LINE, INC. NOT TO BE DUPLICATED. UNSPECIFIED RADII = .015 R TOLERANCES: ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED .XX = ±.03 .XXX = ±.015 ANGLES = ±T SHT OF DRAWING NUMBER: EDO Version: 1.2 1' GRADE PEDESTAL J. c -A FRONT VIEW SIDE VIEW VERTICAL SLAB 2X2 ANGLES TO SUPPORT 110 MPH COLUMN IF REQUIRED. (BY INSTALLER) GRADE T A JPEDESTAL .i FRONT VIEW SIDE VIEW CAISSON 80 MPH COLUMN SET: 11-33-992-0430 110 MPH COLUMN SET: 11-33-992-0430 SLAB WIDTH DIM A SLAB THICKNESS DIM B SLAB DEPTH DIM C CONCRETE (TOTAL) EXCAVATION (TOTAL) 80 MPH 9'0" 2'0" 3'0" 0'3" 2,006 YDS 2,333 YDS 110 MPH 9'0" 2'0" 3'9" I'O" 2,506 YDS 2,833 YDS PEDESTAL WIDTH PEDESTAL LENGTH PEDESTAL THICKNESS 0'9" 80 MPH COLUMN SET: 11-33-992-0440 110 MPH COLUMN SET: 11-33-992-0440 " CAISSON^EPTH' "' DIM A CAISSON DIAMETER DIM B CONCRETE EACH EXCAVATION EACH DIM C CASSION CASSION 80 MPH , , , :,3,g,. , . 2'0" 0'3" 0,415 YDS 0.436 YDS 110 MPH 4'9" ' 2'0" 1'3* 0.531 YDS 0,553 YDS TIMI I LI P.O. BOX 59043 KNOXVILLE, TN 57950-9045 DSGNR: JHP DWG.BY: JHP SCALE: NONE DATE: 5-28-97 DATE CH'K BY: DESCRIPTION:3X8 INSTALLS CUSTOMER: PROPERTY OF PLASTI-LINE, INC. NOT TO BE DUPLICATED. UNSPECIFIED RADII = .015 R TOLERANCES:ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED .XX = ±.03 .XXX = ±.015 ANGLES = ±T SHT 5 OF 5 DRAWING NUMBER:1740 EDO Version: 1.2 -* ENGINEER: Matt Snith CUSTOMER: Honda PROJECT: 3' 8' x 8' 0' Used Car COLUMN P/N:WIND SPEED (70-no) ================ gg MPH 11' 8' oah ND. COL. ITEM HEIGHT 2.000 WIDTH SHAPE FACTOR O.A.H. sign head columns D.A.H. 3,670 8.000 8.000 1.000 11.670 1,000 11,670 0,670 8.000 Vind Load 24.3 24.3 CENTRDID HEIGHT AREA TOTAL FORCE MOMENT 1.835 29.360 4.000 5.360 0,715 1.311 0.845 7.549 ITEM COLUMN STRESSES (CODES P=PIPE;0=DTHER) COLUMN COLUMN Ixx Sxx ALLOW. ACTUAL MOMENT DEPTH WALL COLUMN COLUMN STRESS STRESS t sign head p colunns ITEM 1.311 4x4 7.549 6.625 0.188 0.280 6.590 28.142 3.300 27,600 8.496 23,100 3,999 7. detfection deflection W*L"3A8*E*I) W Ibs 779.777 L in 140.040 0.044 0.061 BOLT CALCULATIONS BOLT BOLTS/ TENSION/ BOLT ALLOW. ALLOWABLE MOMENT SPACING PLATE BOLT DIAMETER STRESS TENSION sign head cotunns ITEM sign head colunns ITEM sign head colunns "'•"-•"'-•• 0.000 0.000 0.000 0.000 0,000 0.000 1.311 7.549 9.000 0.000 4.000 0.000 0.328 ttDIV/0! 0.500 0,000 20,000 0.000 3.927 0.000 PLATE CALCULATIONS TENSION/ 1* BOLT ( 0.328 ttDIV/0! 10MENT SRM 2.500 0.000 MOMENT PLATE 1.639 ttDIV/0! PLATE f WIDTH ] 12.000 0,000 3LATE DEPTH 12,000 0,000 PLATE THICK. 0,375 0.000 MIN. THICK 0.174 ttDIV/0! WELD CALCULATIONS XXXXXXXXXXiOXSSXXSO LENGTH GUSSET THICKNESS GUSSET ANGLE GUSSET In Sw WELD ACTUAL REQ'D WELD 0,000 0,000 0.000 1111 33.250 0.012 0.187 0.000' ' 0.000 "O'.OOO'- ••*-*'•"- 0.000 " "T36.000 0.017" "V-"0'1'88 • add "gussetts 0.000 0,000 0.000 1111 1111 ttDIV/0! 0.000 tube size 0.000 0.000 0.000 1111 1111 ttDIV/0! 0.000 I gussets 0.000 0.000 0.000 1111 nn ftDIV/0! 0.000 I tube 0.000 0.000 0,000 1111 111! ttDIV/0! O.OOO I totalo.ooo o.ooo o.ooo nn nn ttoiv/0! o.ooo swo.ooo o.ooo o.ooo nn nn ttmv/O! o.ooo -85 one per side 423 337 ttDIV/0! MOMENT AT GRADE TOTAL FORCE DIAMETER DE EMBEDDED PIPE DEPTH DF EMBEDMENT foundation size is per poleBLOCK FOUNDATION WEIGHT OF SIGN PEDESTAL WIDTH PEDESTAL LENGTH PEDESTAL THICKNESS PEDESTAL WEIGHT SLAB WIDTH SLAB LENGTH SLAB DEPTH SLAB WEIGHT TOTAL WEIGHT OVERTURNING MOMENT FACTOR OF SAFETY e = OTM/WT L/2 -e SOIL PRESSURE 2*WT/(3*(L/2-e)*WIDTH CONCRETE EXCAVATION MIN. THICKNESS w/o REBAR SQRT(M*12*6*1.7*.75A.178*12*WIDTH) ACTUAL THICKNESS VERTICAL SLAB foundation size is for both poles MOMENT FORCE REFERENCE UBC 2907 8, TABLE 29-B ASSUME SOIL CLASS ft4 SW,SP,SM,SC,GM,8, GC LATERIAL BEARING PRESSURE PSF/FT.DEPTH SI SLAB DEPTH (d) SLAB WIDTH <b> SLAB THICKNESS AVERAGE HEIGHT (h) A = 2.34*FORCEASl*b) CALC. DEPTH MIN, THICKNESS w/o REBAR SQRT<M*12*6*1.7*.75A.178*i2*WIDTH) ACTUAL THICKNESS CONCRETE EXCAVATION CAISSON foundation size is per pole MOMENT FORCE "-'"-:« - • - '" • - •'.• ••-- REFERENCE UBC 2907 8, TABLE 29-B ASSUME SOIL CLASS It4 SW,SP,SM,SC,GM,8, GC LATERIAL BEARING PRESSURE PSF/FT.DEPTH SI CAISSON DEPTH (d) CAISSON DIAMETER (b) AVERAGE HEIGHT (h) A = 2.34*FORCE/(Sl*b) 3.775 0.423 6.625 3.000 0.375 1.000 1.000 0.750 0.113 2.500 3.750 3.000 4.219 4.706 5.359 1.647 1.139 0.736 1.705 1.048 1.215 8.055 36.000 7.549 0.845 150.000 399.900 3.000 9.000 2.000 8.934 0.549 2.604 6.004 24.000 2.006 2,333 3,775 -0,423" 150.000 499.875 3.750 2.000 8.934 KIP-FT. KIP IN. FT. KIP FT, FT. FT. KIP FT. FT. FT. KIP KIP FT.-KIP FT, FT, KSF YDS YDS IN. IN. FT.-KIP KIP PSF/FT. PSF FT. FT. FT. FT. FT. IN. IN. YDS YDS FT.-KIP KIP ' • PSF/FT. PSF FT. FT. FT. DESCRIPTION: LINE P.O. BOX 59043 KNOXVILLE, TN 57950-9045 DSGNR: JHP DWG.BY: JHP SCALE: NONE DATE: 5-28-97 DATE CH'K BY: 3X8 INSTALLS CUSTOMER:HONDA PROPERTY OF PLASTI-LINE, INC. NOT TO BE DUPLICATED. UNSPECIFIED = .015 R RADII TOLERANCES: ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED .XX = ±.03 ,XXX = ±.015 ANGLES = ±r SHT OF DRAWING NUMBER: EDO Version: 1.2 *•' > ENGINEER: Mutt Snith CUSTOMER; Honda PROJECT: 3' 8' x 8' 0' Used Cor 5 11' 8' ooh COLUMN P/N: SHAPE CENTRDID TOTAL [TEM HEIGHT VIDTH FACTOR D.A.H. Vind Lood HEIGHT AREA FORCE MOMENT sign head 3.670 8.000 1.000 11.670 46.0 1.835 29.360 1.351 2.478 colunns 8.000 1.000 0.670 8.000 46.0 4.000 5.360 1.597 14.270 D.A.H. 11.670 C COLUMN STRESSES (CODES P=PIPEiD=DTHER) 0 D COLUMN COLUMN Ixx Sxx ALLOW. ACTUAL E ITEM MOMENT DEPTH WALL COLUMN COLUMN STRESS STRESS 7. defection = ======== ==== ==== ==== -= = = ===== ==== ==== deflection W*LA3/( t sign head 2.478 4x4 0.188 6.590 3.300 27.600 3.380 W Ibs 14 p colunns 14.270 6.625 0.280 28.142 8.496 23.100 7.559 L in 1 BOLT CALCULATIONS XXKXXXXXKXXX**XXX BOLT BOLTS/ TENSION/ BOLT ALLOW. ALLOWABLE ITEM MOMENT SPACING PLATE BOLT DIAMETER STRESS TENSION sign head 2.478 9.000 4.000 0.620 0.500 20.000 3.927 colunns 14.270 0.000 0.000 DDIV/0! 0.000 0.000 0.000 PLATE CALCULATIONS TENSION/ MOMENT MOMENT PLATE PLATE PLATE MIN. ITEM BOLT ARM PLATE WIDTH DEPTH THICK. THICK sign head 0.620 2.500 3.098 12.000 12.000 0.375 0.240 colunns ttDIV/0! 0.000 KDIV/0! 0.000 0.000 0.000 SDIV/0! WELO CALCULATIONS LENGTH GUSSET THICKNESS VELD ACTUAL ITEM GUSSET ANGLE GUSSET Iw Sw REQ'D WELD sign head 0.000 0.000 0.000 ???? 33.250 0.023 0.187 cotunns 0.000 0.000 0.000 0.000 136.000 0.032 0.188 odd gussetts 0.000 0.000 0.000 0.000 ?? HIV/0! 0.000 tube size 0.000 0.000 0.000 0.000 ?? KDIV/0! 0.000 I gussets 0.000 0.000 0.000 0.000 ?? KDIV/0! 0.000 I tubeo.ooo o.ooo o.ooo a.ooo n m\in\ o.ooa i -totalo.ooo o.ooo o.ooo o.ooo n KDIV/OI o.ooo s« »DI\ 0.000 0.000 0.000 0.000 ?? IDIV/0! 0.000 PROPERTY OF PLASTI-LINE, INC. UNSPECIFIE NOT TO BE DUPLICATED. =-015 R MOMENT AT GRADE 7.135 KIP-FT. TOTAL FORCE 0.799 KIP DIAMETER OF EMBEDDED PIPE 6.625 IN. DEPTH OF EMBEDMENT 3.000 FT, BLOCK FOUNDATION Foundation size is per pole WEIGHT OF SIGN 0.375 KIP PEDESTAL WIDTH 1.000 FT. PEDESTAL LENGTH 1.000 FT, PEDESTAL THICKNESS 0.750 FT. PEDESTAL WEIGHT O.U3 KIP SLAB WIDTH 2.500 FT. SLAB LENGTH 5.000 FT. SLAB DEPTH 3.000 FT. SLAB WEIGHT 5,625 KIP TOTAL WEIGHT 6.113 KIP OVERTURNING MOMENT 10.130 FT.-KIP 0.083 FACTOR OF SAFETY 1.509 3"E»I) 0.116 e = DTM/WT 1.657 FT. 403094608 L/2 -e °'843 FL SOIL PRESSURE 2*WT/(3*(L/2-e)*WIDTH 1.934 KSF CONCRETE 1.395 YDS EXCAVATION 1.620 YDS MIN. THICKNESS w/o REBAR 11.075 IN. SQRKM*12*6*l.7*.75/U78*12*W[DTH) ACTUAL THICKNESS 36.000 IN. VERTICAL SLAB foundation size is for both poles MOMENT 14.270 FT.-KIP FORCE 1.597 KIP REFERENCE UBC 2907 8, TABLE 29-B ASSUME SOIL CLASS #4 SW,SP,SM,SC,GM,8, GC LATERIAL BEARING PRESSURE PSF/FT. DEPTH 150.000 PSF/FT, SI 466.550 PSF SLAB DEPTH (cO 3.500 FT. SLAB WIDTH (b) 9.000 FT. SLAB THICKNESS 2.000 FT. AVERAGE HEIGHT (h) 8.934 FT. A = 2.34*FORCEASl*lo) 0,890 8 CALC. DEPTH 3.423 FT, 423 orle per 5I* MIN. THICKNESS w/o REBAR 8.255 IN. 337 SQRT(M*12*6*1.7*.75/U78*12*WIDTH) //O! ACTUAL THICKNESS 24.000 IN. CONCRETE 2,339 YDS EXCAVATION 2.667 YDS CAISSON foundation size is per pole , • , .-,»;,. .•.-.••.- . • • MOMENT « .,,-,= .... .,,. .,-.„ ,!;W; . ..,, 7.135 •• P-T-.-KIP ..•.-•«-.• . •-• -,, &... . , , ,- . .. ,,--s,, ..,.-, FORCE ' 0.799 KIP REFERENCE UBC 2907 8, TABLE 29-B ASSUME SOIL CLASS tt4 SW,SP,SM,SC,GM,i GC LATERIAL BEARING PRESSURE PSF/FT.DEPTH 150.000 PSF/FT. SI 633.175 PSF CAISSON DEPTH (d) 4.750 FT. CAISSON DIAMETER (b) 2.000 FT. AVERAGE HEIGHT (h) 8.934 FT. A = 2.34*FQRCEASl*b) 1.476 FLASH-LINE INC1 lL=r^ ^=} 11 L= II 1 1 L= 5 111 \=/ • P.O. BOX 59043 KNOXVILLE, TN 37950-9043 DSGNR: JHP DWG. BY: JHP CH'K BY: SCALE: NONE DATE: 5-28-97 DATE: °E5CR™: 3 X 8 INSTALLS CU5T°"ERi HONDA n RADII r~ r= DRAWING NUMBER: n— » A —7 * /=•* t=*u I^MUII TOLERANCES- ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED ^UT ^\ OF" ^ W 1 / /I 1 1 Vs, .XX=±.03 .XXX = ±.015 ANGLES = ±T -> ' ' ' ^J ^ " ^J LJ / ^-f \J CJ