Loading...
HomeMy WebLinkAboutPS 06-89; Sun Diego; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 /£- PLANNING APPLICATION #4_^ REC'D BY ' DATE SIGN FEE SIGN PROGRAM^ RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks ^ NAME OF PROJECT: tS O W V^> \ &C D ADDRESS OF PROJECT: ^ ASSESSOR PARCEL NUMBER: (e) (f) (g) 00 Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: Residential Commercial )ffice/Industrial Hotel/Motel SIGN PROGRAM AND/OR .- SPECIFIC PLAN CRITERIA YesJQ/ No D Specific Plan Number . VILLAGE REDEVELOPMENT AREA YesQ No Q Requires VR Approval SIGN ORDINANCE: YesQ No D COASTAL ZONE: YesQ No D Form 10 Revised 12/04 Page 1 of 4 EXISTING SIGNS: TYPE Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) NUMBER 1 A 1N SIGN AREA \ /Jy /^ \ SIGN HEIGHT PERMITS ISSUED FOR EXISTING SIGNS: Yes Q No D Date PROPOSED PERMANENT SIGNS: TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED i NUMBER PROPOSED ( MAXIMUM SIGN AREA SO^ PROPOSED SIGN AREA ^\.^fl MAXIMUM SIGN HEIGHT V PROPOSED SIGN HEIGHT I -a H PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of 4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building/s P/L V--/i *i / Show all property lines [ ,* i • ! •* • 1 S curb Une •* Sight Visibility 1 i Sight Distance Requireni 1 1 how setbacks from all cu l 1 1 1 Street Name(s) 1 i ent irbs North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. Form 10 Revised 12/04 Page 3 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. OWNER NAME (PRINT OR TYPE) MAILING ADDRESS CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. 5u£- &$$^jeA^> £A^, SIGNATURE DATE APPLICANT NAME (PRINT OR TYPE) l"XvA^V^C,iR2vfeA ^YQvv-As^ MAILING ADDRESS ' (\hO "Vicn^w- W\y CITY AND STATE ZIP TELEPHONE ^l^flWcA ^o^ o <**-**-»* I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY ZGE. 1^4? £--}^b SIGNATURE * <zJ—~\ DATE PLANNER CHECK LIST: 1. Field check by planner. Within maximum length, area. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. Location: *«« In right-of-way •t» In visibility triangle at corner Pole and monument signs to be checked by Traffic Engineering, for visibility issues. When approved route copy to Data Entr 2. 3. 4. 5. 6. APPROVED: Planner: (Date: TL Form 10 Revised 12/04 Page 4 of 4 City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: INTEGRATED SIGN Description PS060089 Amount 45.00 Receipt Number: R0057060 Transaction Date: 05/01/2006 Transaction ID: R0057060 Pay Type Method Description Amount Payment Check 45.00 Transaction Amount: 45.00 flPR-21-2006 03:12P FROM:PLANNING SYSTEMS 760 931 5744 70:16195797651 P:2'3 CARLJSBAD ARCHITECTURAL RESEARCH CENTER REVIEW COMMITTEE 21 April 2 006 Mr. Kevin Bern' Integrated Sign Associates 1160 Pioneer Way, Suite M El Cajon, California 92020 Re: Lot 52 - Sun Diego Boardshops Sign Plan Review Dear Kevin: The Architectural Review Committee (ARC) of the Carlsbad Research Center (CRC) has reviewed the sign plans proposed for Sun Diego Boardshops, located at 2105 Rutherford Road. Tbe proposed plans are consistent with die CRC Design Guidelines and therefore the submitted plans are considered APPROVED, Sign construction may begin once a Sign Permit is obtained from the City of Carlsbad. Please feel free to call me if you have any questions or require additional information. Sincerely, Seth Schulbarg cc: A. Blackmore, C. Blackmore, T. Hageman, W. Be^kman and S. McGrath 153O FARADAY AVE., STE. 10O, CARUSBAD CA 92OO8. PM: 76O/931-O78O FAX: 76O/931 -5744 PPR-21-2S06 Q3:13P FROM:PLANNING SYSTEMS 7S0 931 5744 10:16195797551 P:3'3 CARLSBAO RESEARCH CENTER • ARCHITECTURAL REVIEW COMMITTEE Sign Evaluation Matrix for Sun Diego Boardshops (4/19/06) Applicant Address:2105 Rutherford Rd Building Area: N/A Loft No:52 f Sign Criteria Number per lot Number per elevation Sign dimensions Area Sign Height Sign Depth Size of lettering/logo r Area of Lettering Area of lettering/logo Lighting Location CRC Design Guidelines Building area < 35,000 tf - 1 wail or 1 monument Building area 35,000-60,000 ft2 = 1 wall or 1 monument Building area <35,.000 ft* = 1 Building area > 60,000 ft2 = 2 Not specified 50.0 ff maximum - monument Below eave line No standard for wall signs 24 inches maximum - wall sign No standard for wall signs _j Must be internally lit May not be mounted on any architectural projection, parapet, equipment enclosure or on glass portions of building elevations Proposed dimensions 1 waJi 1 over main entrance 12.0 ft. x 1.8ft. 21. 6 ft/ Over main entrance i_Not applicable 15.25 in.= lettering 16.75 in. = logo 21.6ft/ Not applicable No lighting specified Over main entrance The CRC Design Guidelines allow one waif or monument sign for buildings wii/i an area of under 35,000 square fast . * Signs 3 feet or higher must observe ihe building setback. Signs 3 feet or lower mail M located within the setback area, but no closer than 20 feet to the closest curb. The building setback distance is 30 feet from me ptoperty Sine. Proposed sign location at corner of Balfour and Rutherford is not proximate to building driveway. Items In bold face are not in conforrnance with th» Design Guidelines of the CRC. DESIGN NO. I 3O96-O6 21 OS RUTHERFORD CALRSBAD, CALIFORNIA iS\INTEGRATED SIGN ASSOCIATES i*ua/ csmmunflGMtoru tor a (hanging worid \ 160 Pioneer Way, Suite M, El Cajon, California 92020-9144 (619)579-2229 • fax (619) 579-7651 • www.isasign.com SIGN LEGEND FLOOR PLAN NOT TO SCALE NON-ILLUMINATED FABRICATED ALUMINUIt REVERSE CHANNEL LOGO & LETTERS V-43WH. LOGO & 1'-3 W OA HT •SUNDIEGO' LETTERS «12'-0- OVERALL STRETCHOUT. ^Ck INTEGRATED SIGN f^fjfL ASSOCIATES visual communtartfara far a changing wwtf ORIGINAL CONCEPT This design is the exclusive property of Integrated Sign Associates and cannotbe reproduced in whole or in part without their prior written consent. Sun Diego 2105 Rutherford, Carlsbad, CA Kevin Berry March 28, 2006 mwui.m ArnieM. no scale REVISION DATE 13096-0< 1 of TWO PROPOSED LOCATION FOR REVERSE CHANNEL ALUMINUM LOGO 8 LETTERS NON-ILLUMINATED REVERSE CHANNEL LOGO & LETTERS SCALE: 3/8" = V-0" SIGN SPECIFICATIONS 4> LOGO LOGO: FACES & EDGES: GRAPHIC: ILIUM.: QTY: INSTALL: * LETTERS: FACES » EDGES: GRAPHICS: •BOARD- SHOP': ILLUM.: QTY.: INSTALL: FABRICATED ALUMINUM REVERSE CHANNEL LOGO (2' DP.) PAINTED BLACK (SEMI-GLOSS FINISH) FIRST SURFACE APPLIED 3M WHITE #772 5-10 VINYL OVERLAY'S' NON-ILLUMINATED TYP.OFONE(1)LOGO LOGO TO BE PEGGED-OFF 1' FROMBUILDING WALL AS PER DETAIL 6 LEFT. LETTERS FABRICATED ALUMINUM REVERSECHANNEL LETTERS (2 'DP.) PAINTED BLACK (SEMI-GLOSS FINISH) FIRST SURFACE APPUED 3M RED HIGH PERFORMANCE OPAQUE VINYL OVERLAINSET FILM. FIRST SURFACE APPUED 3M WHITE *7725-10 VINYL OVERLAY COPY. NON-ILLUMINATED TYP.OFONE(1)SET LETTERS TO BE PEGGED-OFF 1 ' FROM BUILDING WALL AS PER DETAIL ® LEFT. INTEGRATED SIGN ASSOCIATES vbutlcotiiminkatfoiu tort changing woiltl ORIGINAL CONCEPT This design is the exclusive property of Integrated SignAssociates and cannotbe reproduced in whole or in part without their prior written consent. Sun Diego 2105 Rutherford, Kevin Berry Carlsbad, CA March 28, 2006 ill.l.-lliMHIIW.I»- ArnieM. 13096-0 <* TWO