Loading...
HomeMy WebLinkAboutPS 07-43; Torrey Pines Bank; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION # PS 0"7 - REC'D BY On /Y) nJ^j^UJL^, DATE (gQs^qatefegaq» H 00^-iq-07 SIGN FEE ^HO SIGN PROGRAM FEE - RECEIPT NO. . REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The apDlication must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: f^/P/^M^ ^ I ^^V? h^f^'^ ADDRESS OF PROJECT: 21{o0 Cxkl.^JjJ^ ASSESSOR PARCEL NUMBER: ai3 -300 -Ol-OO RELATED PLANNING CASE NUMBER(S):. TYPE OF DEVELOPMENT: (a) Residential /(^Commercial (c) Office/Industrial (d) Hotel/Motel (e) (f) (g) (h) Service Station Prof Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesD No^ VILLAGE REDEVELOPMENT AREA YesD No^ SIGN ORDINANCE: Yesl^ No • COASTAL ZONE: • •••••••••••••• YesD • • • • No^ Specific Plan Number Requires VR Approval Form 10 Revised 12/04 • ••••••••••••••• Page 1 of 4 EXISTING SIGNS: /\/ | pr TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument 1 Wall Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes • No • PROPOSED PERMANENT SIGNS: Date TYPE (J ' MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** Monument** Wall 1 1 f-HK Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a trafHc hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. • •••••••• Form 10 Revised 12/04 Page 2 of4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. OWNER APPLICANT NAME (PRINT OR TYPE) 5?^ C(ZOIl( NAME (PRINT OR TYPE) ^/C^AjfiCCU Sl^cJfAjtcAL Api^^^-Y/'S/^ MAILING ADDRESS 40£> W p)^£ ff-Sc^ MAILING ADDRESS 4444 /^^!?e/C4t, CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE GNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: • In right-of-way • In visibility triangle at comer 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: Date: (i-)-S '~Q'7 Form 10 Revised 12/04 Page 4 of 4 /CRC OIX Mav31.2007 Ms. Anne Marie Berg Senior Vice President Corporate Facilities Torrey Pines BanJc 760 B Street, Ste. 100 San Diego, CA 92101 Re: Torrey Pines Bank, Bressi Spectrum Signage Dear Ms. Berg: I have received your information and request for approval for the wall sign and the ATM at your building located at Bressi Spectrum, Carlsbad. It appears as this sign meets the criteria and requirments as set by the City and CC&R's. Therefore, this letter serves as approval by the Bressi Spectrum Owners Association. Regards, Cindy Jacob ^ President St. Croix Capital Management Gi'oup, Inc. Acting President Bressi Spectrum Owner,s Association, Inc. Corporate Office; 406 9rh Ave., Suite 309, San Diecc. CA 921C1 • Ph: 619,876.4176 • rx. 619.876.4178 Austin Office: 515 Congress,Ave, Suite 2525E, Ajs'i,-. TX 76701 • Ph: 5i2.391.0718 • Fx: 512.469.7612 R1-Delete the letters wittiout tlie logo. Add call outs to the monument display. 4/13/07-k R2: Deleted sign B; Relocated sign A; added ATM info - 5/21/07(t) R3: Added fabrication options as per customer. 5122/07-3 R4: Revised atm surround - 5/24/07(1) R5: Deleted sign A option - 5/30/07(t) 2760 Gateway Road • Carlsbad, CA 92009 PALOMAR AIRPORT ROAD SIGN PERMIT NO. PS OT-^^ PLANNING BUILDING APPROVED BY DATE fc-S-07 i o <: o DC < CD N 6 w 6igntech 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-6100 / Fax: (619) 527-6111 www.signtechUSA.com 0 Torrey Pines Bank Mall Name Street Address City State Zip n.to- 3/14/07 Salesperson: Je!iyJ^M§!l___ Coordinator: JashaJide Designer J-imlhomseiL Scale: Noted A Revisions A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrlceil to sign location -RESPONSIBIUTf OF OTHERS! Date Customer Signature Ttiis design is ttie exclusive property of Signtech and cannot be reproducecl in whole or in part, without their prior written approval. Drawing Number: 07-00558 Sheet: Of: 1 R5 Rl-Delete ttie letters without ttie logo. Add call outs to the monument display. 4/13/07-l< R2: Deleted sign B; Relocated sign A: added ATM info - 5/21/07(t) R3: Added fabrication options as per customer. 5/22/07-a R4: Revised atm surround - 5/24/07(t) R5: Deleted sign A option - 5/30/07(t) 109'-3"± 21 y2"-"-|^JH^KB¥' n' n BUILDING "A" - NORTH ELEVATION SCALE: 3/32" = 1 '-0" 109'-3"± BUILDING "A" - SOUTH ELEVATION SCALE: 3/32" = I'-O' 16'-0" 6i9ntech 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-6100 / Fax: (619) 527-6111 www.signtechUSA.com MEMBER :nuiiNUiM[ii6yii!i(iiiiDn Torrey Pines Bank Mall Name Street Address City State Zip n.to- 3/14/07 Salesperson: Terry Kitaen Coordinator: JMiaEide_ Designer JMIhornSfilL Scale:_Noted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPV; COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Date Customer Signature This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 07-00558 Sheet: Of 2 4 R5 Rl-Delete the letters without the logo. Add call outs to the monument display. 4/13/07-k R2: Deleted sign B; Relocated sign A: added ATM info - 5/21/07(t) R3: Added fabrication options as per customer. 5/22/07-a R4: Revised atm surround - 5/24/07(t) R5: Deleted sign A option - 5/30/07(t) o 21 1/2" SCALE: 3/8" = 1'-0" 48.27 SQUARE FEET PENETRATIONS LOWER HALF OF LEHERS/LOGO MANUFACTURE & INSTALL ONE (1) SET OF HALO LIT REVERSE PAN CHANNEL LETTERS & LOGO COPY & LOGO: ALUMINUIVI FACES & 3 1/8" DEEP ALUMINUM RETURNS PAINTED TO MATCH PANTONE 5487C GREEN (SEMI-GLOSS) LEHER BACKS: CLEAR LEXAN PEG LEHERS OFF FASCIA WITH 1/2" DIAMETER x 1 5/8" SPACERS PAINTED TO MATCH BUILDING COLOR (T.B.D.) HALO ILLUMINATION: SLOAN MINI WHITE LEDs AS REQUIRED REMOTE POWER SUPPLIES Typical channel letter attachment to Wood framing#10 X 3 Wood screws min. 4 per letter Metal framing#10 X 3" toggle bolt, min. 4 per letter Stud space#10 X 3" toggle bolt, min. 4 per letter Masonry/Goncrete#10 X 3" screw into lead anchor, min. 4 per letter (screw/bolt lengths must be extended for stand off clips/spacers.) 3" , 1 5/8 ALUMINUM RETURN & FACE .050 ALUMINUM CLIPS LED ILLUMINATION CLEAR LEXAN BACK WEEP HOLES REQUIRED FOR ALL EXTERIOR INSTALLATIONS SPACER POWER SUPPLY PRIMARY ELECTRICAL U.L. APPROVED INSTALLATION DETAIL: HALO-LIT REVERSE PAN CHANNEL LETTER WITH LED ILLUMINATION • 1 V2 "=1-0 " 6igntech 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527^6100 / Fax: (619) 527-6111 www.signtechUSA.com Torrey Pines Bank Mall Name Street Address City State Zip n.t»- 3/14/07 Salesperson: Jer[yJ<itaen___ Coordinator: Tasha Eide pocjgnor- TimThomsen Scale:_NQted Revisions A A A A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPX COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBIUTY OF OTHERS! Date Customer Signature This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 07-00558 Sheet: Of: R5 R1-Delete the letters wrttiout the logo. Add call outs to the monument display. 4/13/07-k R2: Deleted sign B; Relocated sign A; added ATM Info - 5/21/07(t) R3: Added fabrication options as per customer. 5/22/07-a R4: Revised atm surround - 5/24/07(1) R5: Deleted sign A option - 5/30/07(1) 5'-7" 1'-2" 2" MULLION (TYR). 2" IVIULLION (TYR). 2'-r OPENING BEYOND OUTER EDGES OF LIGHT BOX TO HAVE 1/4" RADIUS EDGES WHITE LENS 10" 2'-4" o TORREY PINES BANK OUTER EDGES OF SURROUND TO HAVE 1/4" RADIUS EDGES MANUFACTURE AND INSTALL (1) NEW ATIVI SURROUND TO FIT OVER EXISTING ATM. SURROUND : .125" ROUTED AND BRAKE FORMED ALUM. FACE WITH .125" ALUM. RETURNS. FLUSH MOUNTED TO WALL. REMOVABLE ACCESS FRAME TO BE PROVIDED AT FRONT OF ILLUMINATED PORTION OF SURROUND FACE. PAINT : FACE, RETURNS AND NETWORK LOGO COVER PAINTED TO MATCH PMS 5487C GREEN I.D. PANEL: .177" WHITE LEXAN WITH FIRST SURFACE VINYL GRAPHICS: COPY & LOGO: 3630-126 EMERALD GREEN VINYL. DOWN LIGHT LENSE : .177" WHITE LEXAN. ILLUMINATION : (2) 48" DAY LIGHT LAMPS AND BALLAST AS REQUIRED FOR PROPER ILLUMINATION. ATTACH BALLAST RACEWAY TO 1" x 1/8" ALUM. ANGLE FRAME. ATM NETWORK LOGOS: 4" x 6" CLEAR LEXAN PANELS PUSH THRU .125" ALUM. FRAME 1/16". PANELS TO HAVE NETWORK LOGOS ON SECOND SURFACE WITH 3M 3630-10 WHITE VINYL BACKGROUND. ENVELOPE HOLDER WITH CORIAN SURFACE -HINGED WASTE RECEPTACLE DOOR •Mc MASTER CARR ECON D LOCK R 2491 PART#10335A7; 4'-11 MA" 6'-1 1/4" FRONT VIEW SCALE: 3/4" ^ 1'-0" 6igntech 4444 Federal Blvd. San Diego CA 92102 Phone: (619) 527-6100 / Fax: (619) 527-6111 www.signtechUSA.com Torrey Pines Bank Mall Name Street Address City State Zip n.fo- 3/14/07 Salesperson: Je!iyJ<itaerL__ Coordinator: JashaEide Designer JMIhomsmL Scale: Noted Revisions A 5/22/07(1) A A 5/30/07(1) A A A A A A A CUSTOMER APPROVAL Customer Signature Date COPY, COLORS & SIZES Signtech does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Date Customer Signature This design is the exclusive property of Signtecl and cannot be reproduced in whole or in part, without their prior written approval. Drawing Number: 07-00558 Sheet: Of