Loading...
HomeMy WebLinkAboutPS 08-13; Genoptix Medical Laboratory; Sign Permits/Programs (PS)•• City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 SIGN PROGRAM FEE _________ _ RECEIPT NO. ___________ _ REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: Cbtdfl j.;J( tit;,~ / La£1>r4/ery ADDRESS OF PROJECT: o?/10 Z4~r/L . .A t:J ASSESSOR PARCEL NUMBER: -""';;t=-'--'1 Q....._,. __ 0ooL--17L--'Q~---'a~~~---------- RELATED PLANNING CASE NUMBER(S): ________________ _ TYPE OF DEVELOPMENT: (a) Residential ~ommercial '1C} Office/Industrial (d) lfotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA (e) (f) (g) (h) YesD VILLAGE REDEVELOPMENT AREA YesD SIGN ORDINANCE: YesD COASTAL ZONE: YesD Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (l) P-U/OS Zone NoD NoD NoD NoD Specific Plan Number ____ _ Requires VR Approval • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 12/04 Page 1 of4 .. . .. EXISTING SIGNS: n(A TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument - Wall Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes 0 No W Date ______ _ PROPOSED PERMANENT SIGNS: TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED NUMBER PROPOSED SIGN SIGN SIGN SIGN ALLOWED AREA AREA HEIGHT HEIGHT Pole** Monument** I J"'. ?r J1.ll. J -1'1 I Wall Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: (I I A TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED NUMBER PROPOSED SIGN SIGN SIGN SIGN ALLOWED AREA AREA HEIGHT HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 12/04 Page 2 of4 .. SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I 1 I PIL Sight Distance Requirement l I • • I Show building Is • • • • I • • : I ~ I • • Show setbacks from all curbs '----l --- I • • I • I I • • I • I Show all property lines I • • PIL I • • I • ' • I ' • • curb line • • • • • • • ----------~ -- • • (i) Sight Visibility I Street N ame(s) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 12/04 Page 3 of4 ' - EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONT AGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) ____________ ft. ______________________ sq. ft. _li\ ...... 1"-'A,___ _______ sq. ft. ______________________ sq. ft. ___ S'"""--L..Lf_._Lf'..____ sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ______________________ sq. ft. OWNER NAMF (PRINT OR TYPE) ii~t~altl MAILING ADDRESS 11) 610 CITY AND STATE s~ CA- I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. APPLICANT NAME (PRINT OR TYPE) CA I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •!• In right-of-way •:• In visibility triangle at comer 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ~ ~"""-Date:c:l-/4 -i • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 12/04 Page 4 of4 City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 11111.1111111111111111111111111 Applicant: INTEGRATED SIGN ASSOCIATES Description Amount ~.~!~~!". 44.00 2110 RUTHERFORD RD CBAD Receipt Number: R0068596 Transaction ID: R0068596 Transaction Date: 02/07/2008 Pay Type Method Description Amount Payment Check 44.00 Transaction Amount: 44.00 City of Carlsbad Faraday Center Faraday Cashiering 001 0803801-2 02/07/2008 75 Thu Feb07,2008 12:08 PM PERMITS -PERMITS $44 00 lran Nbr: 080380102 0028 0030 Trans/Rcpt#: R0068596 SET #: PS080013 lfEM(S): TOTAL: $44.00 Check (Chk# 003529) $44.00 Total Received: $44.00 Have a nice day! **********~***CUSTOMER COPY************* CARLSBAD RESEARCH CENTER 4 February 2008 Mr. Kevin Berry Integrated Signs 1160 Pioneer Way, Suite M El Cajon, California 92020 Re: Lot 38-Genoptix Sign Review Dear Kathleen: ARCHITECTURAL REVIEW COMMITTEE The Architectural Review Committee (ARC) of the Carlsbad Research Center (CRC) has reviewed the sign plans proposed for Genoptix, located at 2210 Rutherford Road. The proposed plans for a single monument sign are largely consistent with the Design Guidelines, with a single exception. The Guidelines require a 20 foot setback from the face-of- curb for signs 3 feet in height or less. The site plan provided shows the proposed sign to be approximately 10 feet from the face-of-curb. Therefore the submitted plans are considered CONDITIONALLY APPROVED. Prior to installation, please submit a revised site plan indicating a location that meets the 20 foot setback requirement. Please feel free to call me if you have any questions or require additional information. Sincerely, Seth Schulberg cc: A. Blackmore, C. Blackmore, T. Hageman, W. Beckman and S. McGrath 1530 FARADAY AVE., STE. 1 00, CARLSBAD CA 92008, PH: 760/931 {)780 FAX: 760/931-57 44 CARLSBAD RESEARCH CENTER -ARCHITECTURAL REVIEW COMMITTEE Sign Evaluation Matrix for: Genoptix (02/01/08) I Applicant Address: 211 0 Rutherford Rd. Building Area: N/A Lot No: 38 Sign Criteria CRC Design Guidelines Proposed Dimensions Number per lot Building area < 35,000 ft" = 1 wall or 1 monument 1 monument Building area 35,000-60,000 ft2 = 2 wall or 1 monument Number per elevation Monument Sign: 1 per lot. 1 monument Wall Sign: Building area <35,000 ft2 = 1 Building area> 60,000 ft2 = 2 Sign dimensions Not specified 13.3 ft. X 3ft. Area 50.0 ft:t maximum (monument or wall) 39.9 ft:t Sign Height Monument sign: > 3 feet, sign must observe building setback of 30ft. 3ft. ::> 3 feet, setback at least 20 feet from curb Wall Sign: Below eave line Sign Depth Monument signs must be at least 8 inches in depth 1 ft. No standard for wall signs Size of lettering/logo Monument Sign: 18 inches maximum 15 in. Monument Sign: Address lettering::; ?inches (Helvetica) Wall Sign: 24 inches maximum if building area is < 35,000 ft2 36 inches maximum if building area is> 35,000 ft2 Area of Lettering & logo 10 ftL ·--· Percent coverage of Logo/logtype area may not exceed 1/3 of total sign area. 25% lettering and logo No standard for wall signs Lighting Must be internally lit Location Monument sign: Near the primary access point to the lot. Sign setback ~ ··- -1 -- i 1 -~ Wall sign: May not be mounted on any architectural projection, appears to be 10 ft. from curb. A parapet, equipment enclosure or on glass portions of building elevations The CRC Design Guidelines allow one wall or monument sign for buildings with an area of under 35,000 square feet . A. The sign needs to be setback 20 feet from curb. Based on a site visit it appears there is adequate space in the driveway planter to allow a 20 foot setback. Items in bold face are not in conformance with the Design Guidelines of the CRC. !3 '~ ·j 1 •j APPROVED BY DATE 11 ~j PLANNING ~~~M~~=-~~-::.!/~~:!_-_!r~-·~ \: BUILDING I ~. ' ti&*IWFA'"',;;g.:.tt·fu·'-w · ,. ... _....j G ENOPTIX. MEDICAL LABORATORY DESIGN No. 14212-0BR 1 2110 RUTHERFORD ROAD CARLSBAD, CALl FORN lA 92008 INTEGRATED SIGN ASSOCIATES visual communications for a changing world 1160 Pioneer Way, Suite M, El Cajon, California 92020-9144 619.579.2229 • fax 619.579.7651 • www.isasign.com visual communications for a changing world ORIGINAL CONCEPT This design is the exclusive property of Integrated Sign Associates and cannot be reproduced in whole or in part without their prior written consent Genoptix 211 0 Rutherford Road, EXISTING PLANTER MONUMENT SIGN Kevin Berry Carlsbad, CA 92008 January 09, 2007 SCALE: 3/32"=1'-0" REVISION SIGN LEGEND D/F FABRICATED MONUMENT SIGN W/ NON- ILLUMINATED REVERSE CHANNEL LETIERS & ILLUMINATED PUSHED-THRU HORIZONTAL BAR. 3'-0"H X 13'-4"W MONUMENT SIGN. GENERAL NOTES: 1 FIELD VERIFY ALL SIGN LOCATIONS DATE H TO COMPOSITION miNT~~~!\~~~ E~IGN visual communications for a changing world ORIGINAL CONCEPT This design is the exclusive property of Integrated Sign Associates and cannot be reproduced in whole or in part without their prior written consent. PHOTO COMPOSITION Genoptix 211 0 Rutherford Road, Carlsbad, CA 92008 Kevin Berry REVISION DATE 14212-08r1 January 09, 2007 2 FABRICATED AlUMINUM MONUMENT SIGN ''"T tt'"" 1'-<l" DP ..-- REVERSE CHANNEl lEITERS THRU I BRUSH ~ 1.50" THK. PUSHED HORIZONTAl BAR W RED STAINLESS STE ElOVERlAY~ RED lED lllUMINAT ION lES TO MOUNT lED MODU HORIZONTAl SliDIN PANEl FOR SERVICI ACCESS DOOR (FACING BUilDING) GAlUM. NG SECTION VIEW I 13'-4" MONUMENT 8'-0"± I I ------- ~ ~ m p ~ -r-;;;;-_ T -··------ .. . . . . .. .. . . . ·· . .. . .. .. . .. .. . . ·. .·· ... ; · . .-.:.: . .. ·. . . - t -r ~ - ~ - BlACK GRANITE TilE OVERLAY NON-CORROSIVE THREADED STUD ACRYliC MOUNTING PADS (TYP.) AlUMINUM BAFFlE CONCRETE PAD/BASE (FIElD VERIFY) SCALE: 1"-1'-0"0 RELOCATED EXISTING 12" X 18" SPRINKlER BOX (BY OTHERS) 1'-0" DP. END VIEW D/F MONUMENT SIGN a SCALE: 1/2" = 1'-0" visual communications for a changing world ORIGINAL CONCEPT This design is the exclusive property of Integrated Sign Associates and cannot be reproduced in whole or in part without their prior written consent. Genoptix 211 0 Rutherford Road, Kevin Berry REVISION [AM]r1 revised rule overlay. Carlsbad, CA 92008 January 09, 2007 SIGN SPECIFICATIONS D/F MONUMENT SIGN MON. D/F FABRICATED ALUMINUM MONUMENT SIGN W/ BLACK GRANITE OVERLAY TILE. BKGD.: ABSOLUTE BLACK GRANITE TILE. LETTERS: NON-ILLUMINATED FABRICATED REVERSE STAINLESS STEEL CHANNEL LETTERS (2 1/2" DP.) W/ BRUSH FINISH.LETTERS TO BE PEGGED-OFF 1/2" FROM FACE OF MONUMENT. RULE: SHELF-CUT & PUSHED-THRU 1.50" THK. ACRYLIC PLASTIC RULE W/ POLISHED EDGES & FIRST SURFACE APPLIED BRUSH RED STAINLESS STEEL OVERLAY & SUB- SURFACE APPLIED 3M WHITE DIFFUSER FILM. ADDRESS: NON-ILLUMINATED FABRICATED REVERSE CHANNEL STAINLESS STEEL ADDRESS NUMERALS (1/2" DP.) W/ BRUSH FINISH. ADDRESS NUMERALS TO BE FLUSH MOUNTED . ILLUM.: RED LED ILLUMINATION@ HORIZONTAL RULE ONLY . QTY.: TYP. OF ONE (1) MONUMENT. INSTALL: MONUMENT SIGN TO BE INSTALL ONTO LANDSCAPE AREA AS REQUIRED. NOTES: EXISTING 12"X 18" SPRINKLER BOX TO BE RELOCATED (BY OTHERS). FIELD VERIFY DIMENSION & CONDI- TIONS PRIOR TO MANUFACTURING MONUMENT SIGN. SQUARE FOOTAGE: LETTERS & RULE: 10 SQ. FT. ' MONUMENT SIGN :39.99 SQ.FT. DATE 01-11-08