HomeMy WebLinkAboutPS 08-13; Genoptix Medical Laboratory; Sign Permits/Programs (PS)••
City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4610
SIGN PROGRAM FEE _________ _
RECEIPT NO. ___________ _
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
NAME OF PROJECT: Cbtdfl j.;J( tit;,~ / La£1>r4/ery
ADDRESS OF PROJECT: o?/10 Z4~r/L . .A t:J
ASSESSOR PARCEL NUMBER: -""';;t=-'--'1 Q....._,. __ 0ooL--17L--'Q~---'a~~~----------
RELATED PLANNING CASE NUMBER(S): ________________ _
TYPE OF DEVELOPMENT:
(a) Residential
~ommercial
'1C} Office/Industrial
(d) lfotel/Motel
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA
(e)
(f)
(g)
(h)
YesD
VILLAGE REDEVELOPMENT AREA YesD
SIGN ORDINANCE: YesD
COASTAL ZONE: YesD
Service Station
Prof. Care
Theater
Govt/Church
(i) Public Park
(j) Produce Stand
(k) Nursery
(l) P-U/OS Zone
NoD
NoD
NoD
NoD
Specific Plan Number ____ _
Requires VR Approval
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Form 10 Revised 12/04 Page 1 of4
.. . ..
EXISTING SIGNS: n(A
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument -
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes 0 No W Date ______ _
PROPOSED PERMANENT SIGNS:
TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
NUMBER PROPOSED SIGN SIGN SIGN SIGN
ALLOWED AREA AREA HEIGHT HEIGHT
Pole**
Monument** I J"'. ?r J1.ll. J -1'1
I
Wall
Suspended
Directional
Canopy
Freestanding**
(Project
Identity)
PROPOSED TEMPORARY SIGNS: (I I A
TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
NUMBER PROPOSED SIGN SIGN SIGN SIGN
ALLOWED AREA AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues. Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Form 10 Revised 12/04 Page 2 of4
..
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter. Additional time will be required for on-site inspection.
I I
1 I
PIL Sight Distance Requirement l I • • I Show building Is • • • • I • • : I
~ I • • Show setbacks from all curbs '----l ---
I • • I • I I • • I • I Show all property lines I • • PIL I • • I •
' • I ' • •
curb line • • • • • • • ----------~ --
• •
(i) Sight Visibility
I
Street N ame(s)
I
I North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Form 10 Revised 12/04 Page 3 of4
' -
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONT AGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.)
____________ ft.
______________________ sq. ft.
_li\ ...... 1"-'A,___ _______ sq. ft.
______________________ sq. ft.
___ S'"""--L..Lf_._Lf'..____ sq. ft.
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ______________________ sq. ft.
OWNER
NAMF (PRINT OR TYPE)
ii~t~altl
MAILING ADDRESS
11) 610
CITY AND STATE
s~ CA-
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT
ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE.
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
APPLICANT
NAME (PRINT OR TYPE)
CA
I CERTIFY THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA-
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: •!• In right-of-way
•:• In visibility triangle at comer
5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner: ~ ~"""-Date:c:l-/4 -i
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Form 10 Revised 12/04 Page 4 of4
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
11111.1111111111111111111111111
Applicant: INTEGRATED SIGN ASSOCIATES
Description Amount
~.~!~~!". 44.00
2110 RUTHERFORD RD CBAD
Receipt Number: R0068596 Transaction ID: R0068596
Transaction Date: 02/07/2008
Pay Type Method Description Amount
Payment Check 44.00
Transaction Amount: 44.00
City of Carlsbad
Faraday Center
Faraday Cashiering 001
0803801-2 02/07/2008 75
Thu Feb07,2008 12:08 PM
PERMITS -PERMITS $44 00
lran Nbr: 080380102 0028 0030
Trans/Rcpt#: R0068596
SET #: PS080013
lfEM(S): TOTAL: $44.00
Check (Chk# 003529) $44.00
Total Received: $44.00
Have a nice day!
**********~***CUSTOMER COPY*************
CARLSBAD
RESEARCH CENTER
4 February 2008
Mr. Kevin Berry
Integrated Signs
1160 Pioneer Way, Suite M
El Cajon, California 92020
Re: Lot 38-Genoptix Sign Review
Dear Kathleen:
ARCHITECTURAL
REVIEW COMMITTEE
The Architectural Review Committee (ARC) of the Carlsbad Research Center (CRC) has
reviewed the sign plans proposed for Genoptix, located at 2210 Rutherford Road.
The proposed plans for a single monument sign are largely consistent with the Design
Guidelines, with a single exception. The Guidelines require a 20 foot setback from the face-of-
curb for signs 3 feet in height or less. The site plan provided shows the proposed sign to be
approximately 10 feet from the face-of-curb. Therefore the submitted plans are considered
CONDITIONALLY APPROVED. Prior to installation, please submit a revised site plan
indicating a location that meets the 20 foot setback requirement.
Please feel free to call me if you have any questions or require additional information.
Sincerely,
Seth Schulberg
cc: A. Blackmore, C. Blackmore, T. Hageman, W. Beckman and S. McGrath
1530 FARADAY AVE., STE. 1 00, CARLSBAD CA 92008, PH: 760/931 {)780 FAX: 760/931-57 44
CARLSBAD RESEARCH CENTER -ARCHITECTURAL REVIEW COMMITTEE
Sign Evaluation Matrix for: Genoptix
(02/01/08)
I Applicant Address: 211 0 Rutherford Rd. Building Area: N/A Lot No: 38
Sign Criteria CRC Design Guidelines Proposed
Dimensions
Number per lot Building area < 35,000 ft" = 1 wall or 1 monument 1 monument
Building area 35,000-60,000 ft2 = 2 wall or 1 monument
Number per elevation Monument Sign: 1 per lot. 1 monument
Wall Sign: Building area <35,000 ft2 = 1
Building area> 60,000 ft2 = 2
Sign dimensions Not specified 13.3 ft. X 3ft.
Area 50.0 ft:t maximum (monument or wall) 39.9 ft:t
Sign Height Monument sign: > 3 feet, sign must observe building setback of 30ft. 3ft.
::> 3 feet, setback at least 20 feet from curb
Wall Sign: Below eave line
Sign Depth Monument signs must be at least 8 inches in depth 1 ft.
No standard for wall signs
Size of lettering/logo Monument Sign: 18 inches maximum 15 in.
Monument Sign: Address lettering::; ?inches (Helvetica)
Wall Sign: 24 inches maximum if building area is < 35,000 ft2
36 inches maximum if building area is> 35,000 ft2
Area of Lettering & logo 10 ftL
·--· Percent coverage of Logo/logtype area may not exceed 1/3 of total sign area. 25%
lettering and logo No standard for wall signs
Lighting Must be internally lit
Location Monument sign: Near the primary access point to the lot. Sign setback
~
··-
-1 --
i 1 -~
Wall sign: May not be mounted on any architectural projection, appears to be 10
ft. from curb. A parapet, equipment enclosure or on glass portions of building
elevations
The CRC Design Guidelines allow one wall or monument sign for buildings with an area of under 35,000 square feet .
A. The sign needs to be setback 20 feet from curb. Based on a site visit it appears there is adequate space in the driveway planter to allow a 20
foot setback.
Items in bold face are not in conformance with the Design Guidelines of the CRC.
!3 '~ ·j 1 •j APPROVED BY DATE 11
~j PLANNING ~~~M~~=-~~-::.!/~~:!_-_!r~-·~
\: BUILDING I
~. ' ti&*IWFA'"',;;g.:.tt·fu·'-w · ,. ... _....j
G ENOPTIX.
MEDICAL LABORATORY
DESIGN No. 14212-0BR 1
2110 RUTHERFORD ROAD
CARLSBAD, CALl FORN lA 92008
INTEGRATED SIGN
ASSOCIATES
visual communications for a changing world
1160 Pioneer Way, Suite M, El Cajon, California 92020-9144
619.579.2229 • fax 619.579.7651 • www.isasign.com
visual communications for a changing world
ORIGINAL CONCEPT
This design is the
exclusive property
of Integrated Sign
Associates and cannot
be reproduced in whole
or in part without their
prior written consent
Genoptix
211 0 Rutherford Road,
EXISTING PLANTER
MONUMENT SIGN
Kevin Berry
Carlsbad, CA 92008 January 09, 2007
SCALE: 3/32"=1'-0"
REVISION
SIGN LEGEND
D/F FABRICATED MONUMENT SIGN W/ NON-
ILLUMINATED REVERSE CHANNEL LETIERS &
ILLUMINATED PUSHED-THRU HORIZONTAL BAR.
3'-0"H X 13'-4"W MONUMENT SIGN.
GENERAL NOTES:
1 FIELD VERIFY ALL SIGN LOCATIONS
DATE
H TO COMPOSITION
miNT~~~!\~~~ E~IGN
visual communications for a changing world
ORIGINAL CONCEPT
This design is the
exclusive property
of Integrated Sign
Associates and cannot
be reproduced in whole
or in part without their
prior written consent.
PHOTO COMPOSITION
Genoptix
211 0 Rutherford Road, Carlsbad, CA 92008
Kevin Berry REVISION DATE 14212-08r1
January 09, 2007 2
FABRICATED AlUMINUM
MONUMENT SIGN
''"T tt'"" 1'-<l" DP
..--
REVERSE CHANNEl lEITERS
THRU
I BRUSH ~
1.50" THK. PUSHED
HORIZONTAl BAR W
RED STAINLESS STE ElOVERlAY~
RED lED lllUMINAT ION
lES TO MOUNT lED MODU
HORIZONTAl SliDIN
PANEl FOR SERVICI
ACCESS DOOR
(FACING BUilDING)
GAlUM.
NG
SECTION VIEW
I
13'-4" MONUMENT
8'-0"±
I
I
-------
~ ~
m p
~ -r-;;;;-_ T
-··------
.. . . . . .. .. . . . ·· . .. . .. .. . .. .. . . ·. .·· ... ; · . .-.:.: . .. ·. . . -
t
-r
~ -
~
-
BlACK GRANITE
TilE OVERLAY
NON-CORROSIVE
THREADED STUD
ACRYliC MOUNTING
PADS (TYP.)
AlUMINUM BAFFlE
CONCRETE PAD/BASE
(FIElD VERIFY)
SCALE: 1"-1'-0"0
RELOCATED EXISTING 12" X 18"
SPRINKlER BOX (BY OTHERS)
1'-0"
DP.
END VIEW
D/F MONUMENT SIGN a SCALE: 1/2" = 1'-0"
visual communications for a changing world
ORIGINAL CONCEPT
This design is the
exclusive property
of Integrated Sign
Associates and cannot
be reproduced in whole
or in part without their
prior written consent.
Genoptix
211 0 Rutherford Road,
Kevin Berry REVISION
[AM]r1 revised rule overlay.
Carlsbad, CA 92008 January 09, 2007
SIGN SPECIFICATIONS
D/F MONUMENT SIGN
MON. D/F FABRICATED ALUMINUM MONUMENT
SIGN W/ BLACK GRANITE OVERLAY TILE.
BKGD.: ABSOLUTE BLACK GRANITE TILE.
LETTERS: NON-ILLUMINATED FABRICATED REVERSE
STAINLESS STEEL CHANNEL LETTERS
(2 1/2" DP.) W/ BRUSH FINISH.LETTERS
TO BE PEGGED-OFF 1/2" FROM FACE OF
MONUMENT.
RULE: SHELF-CUT & PUSHED-THRU 1.50" THK.
ACRYLIC PLASTIC RULE W/ POLISHED
EDGES & FIRST SURFACE APPLIED BRUSH
RED STAINLESS STEEL OVERLAY & SUB-
SURFACE APPLIED 3M WHITE DIFFUSER
FILM.
ADDRESS: NON-ILLUMINATED FABRICATED REVERSE
CHANNEL STAINLESS STEEL ADDRESS
NUMERALS (1/2" DP.) W/ BRUSH FINISH.
ADDRESS NUMERALS TO BE FLUSH
MOUNTED .
ILLUM.: RED LED ILLUMINATION@ HORIZONTAL
RULE ONLY .
QTY.: TYP. OF ONE (1) MONUMENT.
INSTALL: MONUMENT SIGN TO BE INSTALL ONTO
LANDSCAPE AREA AS REQUIRED.
NOTES: EXISTING 12"X 18" SPRINKLER BOX TO
BE RELOCATED (BY OTHERS).
FIELD VERIFY DIMENSION & CONDI-
TIONS PRIOR TO MANUFACTURING
MONUMENT SIGN.
SQUARE FOOTAGE:
LETTERS & RULE: 10 SQ. FT.
' MONUMENT SIGN :39.99 SQ.FT.
DATE
01-11-08