Loading...
HomeMy WebLinkAboutPS 08-140; San Diego Premier Training; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION #-----~.f.-..::S_D_B_-...:....14-_,__D_ REC'D BY t:l \ U1l-~lj~ DATE lU'Z.-...-oa • SIGN FEE ..::::!~~5..LJ.· (p!oii:.------------ SIGN PROGRAM FEE--------- RECEIPT NO.------------ REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign( s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00p.m. Average processing time: 2 weeks NAME OF PROJECT: 5D \)re_m ier ]?a l (l t /\_~ ADDREss oF PROJECT: &q q 4 £{ Ca111j a c) IP._pa.Q #-f COt - ASSESSORPARCELNUMBER: _______________________________ _ RELATED PLANNING CASE NUMBER(S): ----------------------- TYPE OF DEVELOPMENT: (a) Residential (b) Commercial (c) Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA (e) (f) (g) (h) YesO VILLAGE REDEVELOPMENT AREA YesD SIGN ORDINANCE: COASTAL ZONE: YesD YesD Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OS Zone NoD No.D Specific Plan Number ____ _ NoD NoD Requires VR Approval t t • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 3/08 Page I of4 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument WaD Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes 0 No 0 Date ------- PROPOSED PERMANENT SIGNS: TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED NUMBER PROPOSED SIGN SIGN SIGN SIGN ALLOWED AREA AREA HEIGHT HEIGHT Pole** Monument** WaD I I 'lS~Q5 rA l/.~7) rA .l <a (I llQII Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED NUMBER PROPOSED SIGN SIGN SIGN SIGN ALLOWED AREA AREA HEIGHT HEIGHT Construction** For Sale** Banner **Prior to approval, aU proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 3/08 Page 2 of4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I 1 I Pll.. • Sight Distance Requirement • I • • I Show building/s • • • I • • • I : I I • • • Show setbacks from all curbs ,_ ---l --- I • • I • I I • • I • I Show all property lines I • • Pll.. I • • I • I • I I • • curb line • • • • • • • ----------:ce -- Sight Visibility I Street N ame(s) Ci> I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 3/08 Page 3 of4 .. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONT AGE TOTAL SIGN AGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) ____________ ft. ____________________ sq. ft. _____________________ sq. ft. ____________________ sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ____________________ sq. ft. _____________________ sq. ft. PROPERTY OWNER NAME (PRINT OR TYPE) C.Oll f~ \vtt'Q . MAILING ADDRESS I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. -"'-"-J!l~a~-~-· ·-~ tl-a-o-Dt SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. APPLICANT NAME (PRINT OR TYPE) rvt MAILING ADDRESS I LJ20S: o CITY AND STATE ZIP I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNA~ (?~,0~ 'ffiF 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •!• In right-of-way •!• In visibility triangle at comer 5. 6. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. When approved route copy to Data Entry APPROVED: Planner: -=Gt;........!...!.l~.:........LfJc_~~__,!:I(L,..w:._ ______ __ Date: 11-{ 1.-/ cF/ I • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 10 Revised 3/08 Page 4 of4 ----------------------------------------------------------------- . ~· . PROJECT AGREEMENT 141.6" ::;:~~TRAINING liS" Qty. 1 set 5" deep aluminum channel1etters & 5" deep 18" x 24" aluminum logo box -Letters are 18" tall with blue acrylic faces with black trim cap & returns -Logo box is 18" x 24" with white acrylic face, black trim cap & returns with full color laminated digital translucent print applied to face. -Mounted to 18" x 142" x 8" deep aluminum raceway painted to match building stucco Total Area of sign = 17.68 sq ft Total Area Allowed = 28.5 sq ft Linear footage of storefront = 19 linear feet channel letter detail*** This delign and cll'aM!g eubmltted for yo..-rev~-and approwlls the exclusive property of IUGN*A*RAMA. It may not be repn:dlcad, copied, axhilited or utilzad for eny purpose, in part or in whole by any individual inside o.a outside without writlan oor..rt of SIGN*A*RAJIA. APPROVALS CUSTOMER:~ Przmi{Vlrttlni (d{C1Lf B\ CCtmlnD~a.J *t Ct4i~CA SIGNATURE: --------------------- DATE: --------------------------- 0 SEE DISCLAMIER 0 SEEWAIVER PROPERTY MANAGEMENT: SIGNATURE: --------------------- DATE: --------------------------- 0 SEE OTHER ATTACHMENT(S) 8 SIGN*A*RAMA ~-....-""~ -------------- 191 N. El Camino Real, Suite 206 Encinitas, California 92024 phone 76G-634-3217 fax 76G-634-3218 sar92024@sbcglobal.net Channel letter detail: 1'4 5" ... I .040 ALUM. RETURNS,-----tt--_J 3/16" ACRYLIC WITH PLASTIC RETAINER---. ... L.E.D. ILLUMINATORS AS REQUIRED.-----tt-----•1 .063 ALUM. BACK----+t----..-.1 SEAL ENTRY & EXIF-----+t-------'t~H~lltcf----~ HOLES W/ SILICONE Y." WEEP HOLES----++-------., (2MIN.) EXIST. WALL:----------•1 DETAIL FOR TYPICAL CHANNEL LETTER W/ILLUM. PLEX FACE NOTES: NOT TO SCALE 1-All seams to be placed for min. visibility. 2-Install to conform w/ section 600 of NEC. 3-Letters fabricated to UL standards. 4-Transformer mounting TBD. in field . 5-Letters to be canst. to prevent light leaks. 6-Min. 2 mounting bolts per letter. 1/8" -1/4"ANCHOR BOLTS (4) MIN. REQ, NON CORROSIVE #SSCREWS ,------LETTER TO LETTER JUMP. POWER SUPPLY OUTPUT LEAD OR EXTENDED LEAD USING APPROPRIATE UL LISTED PLTC: Up to 15' = 18AWG I Up to 50'= 14AWG NEMA 3R or UL listed for wet location electrical/ transformer box (box not required if power supply is installed indoors (ie: attic). 24 VOLT TRANSFORMER +-DISCONNECT SWITCH (1 PER CIRCUIT) ....._""'!"""------fff!-""' EXISTING ELECTRICAL-----' PANEL BRANCH CIRCUIT(S) (BY OTHERS) FOR SIGN ----------M31 See notes for requirements Branch Circuit: eo•,.E~~so!:.'.:~i~~~u .... A. All branch circuits for signs must be totally dedicated to signs (induding dedicated ground and dedicated neutral per circuit rli\ IIIHmiten B Sign circuits must not be shared with olher loads such as lighting, air conditioning, and other equipment \:1) t.alllrlterin IK. c. Properly sized ground wire that can be traced back to the breaker panel must be prov1ded. D. Number and size of circuits for each sign to meet requirements .. ELECTRIC SIGN WESTBLUFF PLAZA 6986-6996 EL CAMINO REAL I CARLSBAD, CAUF"ORNIA ____..... oc:_.aMl'llt 1r TYPICAL PARKING STAll. ~==15~~~~~~~-r-----, I :~:__!-!iiMb';;:,;;:;:;;;--·-1 ) EL SCALD 1'=40' ~ 0 "' < g < ,J.N. 2001-:)J City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 lllllllllillllllllll~~ll~llllllllllllllllllllllllllllllll Applicant: FORD STACY Description Amount PS080140 56.00 6994 EL CAMINO REAL CBAD Receipt Number: R0072840 Transaction ID: R0072840 Transaction Date: 12/02/2008 Pay Type Method Description Amount Payment Check 56.00 Transaction Amount: 56.00 ~ I I ' .. i .. .. . ~ ) g ) .. ... ) .. ... "' .. APPROVALS CUSTOMER; u-0!_P Q .o -~' SK!NATURE· Jfl: __ -·--· 4#. nA'It:: :ti,-J,,r,. . _......_:.1-t-'-,!,+.w.._·--- p,gc 1 ofl ______ .,:.141.0'' ~~~!TRAINING ll8· ·-----~ --I" -=---....... -we~ ... ---·~ ·-·--''" .. - I Lll11!00S ··==~--~111 • 4 sc .J$ e e _,.,. :M-• , · PROJECT AGREEMENT ~ APPROVALS CUSTOMER:~ f:r-twti~T~ivv· ~4 CC( ~minD Jq(.l..X -±t-1 C~LCA SIGNATURE: ------------------- DATE: -------------------------- 141.6" Qty. 1 set 5" deep aluminum channel letters & S" deep 18" x24" aluminum logo box -Letters are 18" tall with blue acrylic faces with black trim cap & returns -Logo box is 18" x 24" with white acrylic face, black trim cap & returns with full color laminated digital translucent print applied to face. -Mounted to 18" x 142" x 8" deep aluminum raceway painted to match building stucco Total Area of sign = 17.68 sq ft Total Area Allowed = 28.5 sq ft Linear footage of storefront = 19 linear feet ***See attached page for channel letter detail*** D SEE DISCLAMIER D SEEWAIVER D SEE OTHER ATTACHMENT(S) PROPERTY MANAGEMENT: • SIGN*A*RAMA ~»c_,_,.,:;o ------------- SIGNATURE: ________ _ 191 N.EI Camino Reai,Suite206 Encinitas, California 92024 phone 76Q-634-3217 fax 76o-634-3218 sar92024@sbcglobal.net DATE: ___________________ _ Channel letter detail: 5" .040 ALUM. RETURNS-----tt--___.J 3/16" ACRYLIC WITH PLASTIC RETAINEttR---11>• L.E.D. ILLUMINATORS AS REQUIRED.-----++-----•1 .063 ALUM. BACK----t+----t--1111 SEAL ENTRY & EXJl'-----++-------tHIIII+---~ HOLES W/ SILICONE W WEEP HOLES ----tt------, (2MIN.) EXIST. WALL:------------.1 DETAIL FOR TYPICAL CHANNEL LETTER W/ILLUM. PLEX FACE NOTES: NOT TO SCALE 1-All seams to be placed for min. visibility. 2-lnstall to conform w/ section 600 of NEC. 3-Letters fabricated to UL standards. 4-Transformer mounting TBD. in field. 5-Letters to be const. to prevent light leaks. 6-Min. 2 mounting bolts per letter. 1/8" -1/4"ANCHOR BOLTS (4) MIN. REQ. NON CORROSIVE #8SCREWS .---LETTER TO LETTER JUMP. POWER SUPPLY OUTPUT LEAD OR EXTENDED LEAD USING APPROPRIATE UL LISTED PLTC: Up to 15' = 18AWG I Up to 50'= 14AWG NEMA 3R or UL listed for wet location electrical/ transformer box (box not required if power supply is installed indoors (ie: attic). 24 VOLT TRANSFORMER +--DISCONNECT SWITCH (1 PER CIRCUIT) ....._~------FFFJ--1 EXISTING ELECTRICAL--_J PANEL +---J-BOX (BY OTHERS) BRANCH CIRCUIT(S) (BY OTHERS) FOR SIGN-----------F'lll See notes for requirements Branch Circuit: -~..:'::i~- A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit tlj\......,. B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. ~) I.Herllllillllc. c. Properly sized ground wire that can be traced back to the breaker panel must be provided. ELECTRiC SIGN D. Number and size of circuits for each sign to meet requirements .. WESTBLUFF PLAZA 6986-6996 EL CAMINO REAL CARLSBAD. CAUFORNIA w 6~ 0 El .. .. .... n'PICAI.. PARICINC STAll. ~m ,..uDCJNCJ sr..u.s =~~~~~----, ., SCALE• 1'=40' .. • ~-.... ~· Si -:.. CL -~:0.8. -"""'-... -., -;.~: "' -, ... .... ..... ..... ...., ~ ......... I "" g < .... ;;> <( ~ ~ :5 N .., <( "'< " -' oz z o_ :;;3 S2 ~~ 0:: o3 < lL Q. lL.--' 0 ~ ~~ ... ~ -' "'II! Q. ~ ~~ 0 "' Ulll: Cl. w m iii 5 i li! .. ""'"" 1 .LN. 2001-33 ; I I ' .. s :I • .. 1:1 ;J I' 'll D , D .. I.PPROVAUI CUSTOMER: M' ,, () 0). ,/) 1 SIONATURfo J!l."..g)!_ JA:t.J. nAT£: • ...JJ..j.J.1.(.:;.1:_______ - J'vgtll ofl ______ ..:,.14,1.0'' ~~~JTRAINING lw ·---··--'!11 --~·· -=---- ,. .. -~ ..., ---.. ~ ·-·--· ~..... -- ll111'200S ,., .... as.w~. 14-C: 1.'1 E