Loading...
HomeMy WebLinkAboutPS 09-44; Toyota Carlsbad Service Center; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION # PS REC'D BY giuXd . yjiJCf-gyy DATE^-/7r^ SIGN FEE (O ,(yO SIGN PROGRAM FEE RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department AU plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must bc submitted prior to 4;00 p.m. Average processing time: 2 weeks NAME OF PROJECT:"" ADDRESS OF PROJECT: ^ (1 %0 _ J\ t O A-- ^^C/ /O 9^ ASSESSOR PARCEL NUMBER: RELATED PLANNING CASE NUMBER(S): \/- 0 ^-<Q^ TYPE OF DEVELOPMENT: (a)Residential (e) A-t^) Commercial (f) (c) Office/Industrial (g) (d) Hotel/Motel (h) Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesD No VILLAGE REDEVELOPMENT AREA YesD No SIGN ORDINANCE: Yes/S No • COASTAL ZONE: Yesp No • *************** • • • • * * * Form 10 Revised 3/08 Specific Plan Number . Requires VR Approval ******* ******* Page 1 of 4 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended Directional r Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTE^G SIGNS: Yes • No • Date PROPOSED PERMANENT SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** Monument** I \ WaU Suspended Directional u ^\ Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 3/08 * * * * * Page 2 of4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINE^G SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. . sq. ft. . sq. ft. . sq. ft. sq. ft. , sq. ft. PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRESS CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE C) DATE SIGlJiATURE f\ DATE PLANNER CHECK LIST 1. 2. 3. 4. 5. 6. Field check by planner. Within maximum length, area. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. Location: • In right-of-way • In visibility triangle at comer Pole and monument signs to be checked by Traffic Engineering, for visibility issues. When approved route copy to Data Entry APPROVED: Planner: ^A,,,^^Y\)] ^/^i. Date: ************* Form 10 Revised 3/08 ************************* Page 4 of 4 City of Carlsbad Faraday Center Faraday Cashiering 001 0910701-1 04/17/2009 75 Fri, ,Apr 17, 2009 04;27 PM Receipt Ref Nbr: R0910701-1/0036 PERMITS - PERMITS Tran Ref Nbr; 091070101 0036 0038 Trans/Rcpt#: R0074414 SET #: PS090044 Amount: 1 § $56,00 Item Subtotal: $56,00 Item Total: $56,00 1 ITEM(S) TOTAL: $56.00 Check (Chk# 005622) $56.00 Total Received: $56.00 Have a nice day! **************CUST0MER COPY************* City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: TOYOTA OF CARLSBAD Description Amount PS090044 56.00 6020 AVENIDA ENCINAS CBAD Not valid unless validated by Cash Register PLEASE RETAIN RECEIPT FOR REFUNDS OR ADJUSTMENTS Receipt Number: R0074414 Transaction ID: R0074414 Transaction Date: 04/17/2009 Pay Type Method Description Amount Payment Check 56.00 Transaction Amount: 56.00 CL Page 3 of 3 I mm EAST ELEVATNm WESraEVATKW Elevations CLICK BELOW FOR MORE INFORMATION S'-O" TOYOTA &- 0" 8'-4" M86 D/F ILLUMINATED MONUMENT STREETSIDE fMOTE: LOW EDGE OF MONUMENT TOWARDS STREET. HIGH EDGE OF MONUMENT TOWARDS BUILDING. https://www.epattison.com/5gf4du/printPhotosp.cfm?ss=BIUGXD511FB71M9M059OYHX7D05NZ98N... 2/5/2009 BOB WOLF PROJECT MANAGER OFFICE (760) 496-2931 FAX (760) 496-2979 MOBILE (760) 497-7286 CORPORATE OFFICES OF 6030 AVENIDA ENCINAS, STE. A CARLSBAD, CALIFORNIA92009 / \ ^^'<i ^ ^ \ \ '\ \ 1 \ '"mm o J CONC 1.11 CU. YDS. OF REQ'D. r CABINET & CLADDING DESIGN BY OTHERS ELECTRICAL DESIGN BY OTHERS 2"x2"x1/4" STEEL ANGLE, TYP. r- C6x8.2 STEEL ' CHANNEL 1" DIA. X 18" LONG ANCHOR BOLT (4 REQ'D) TS 6x2x1/4 5"x5"x3/8" STEEL GUSSET GRADE ^^^^^^^^^ -3'-0" -ELECTRICAL CONDUIT (3) #4 VERT. BARS @ 14" O.C. WITH (4) #4 HORIZ. BARS @ 13" O.C. ON THE WINDW/ARD & LEEWARD FACES OF THE FOUNDATION. 3" MIN. COVER. DO NOT WELD REBAR. l'-6" 1'-2' -2'-6" ELEVATION SIDE VIEW TYP!> '3/1 B-k' NOTES: 1. Design is based on 85 mph 3 second gust design wind speed per CBC 2007. Exposure C. 2. Foundation is based on a safe lateral soil bearing pressure mininnum of 100 psf per foot of depth. Soil report was not furnished. Allowable bearing pressure should be verified prior to placement of concrete. Do not place foundation in fill. 3. Concrete sholl be mixed to ottoin a minimum compressive strength of 2500 psi in 28 days. 4. Support members shall be free from defects end sholl meet ASTM A500 grode B with a minimum yield strength of 46000 psi for tube. Plate and angle shall meet ASTM A36. 5. Structural bolts shall be A325 zinc coated unless otherwise noted. 6. Anchor bolts shall be cut from A36 round stock. Exposed surfaces sholl be galvanized or coated to prevent corrosion. 7. All voids between column base plate ond foundation surface sholl be completely filled with high strength, non-shrink grout. 8. Welds shall be made with E70xx electrodes by persons qualified in occordonce with AWS stondords within the post two years. 9. Steel reinforcing bars shall conform to ASTM 615 grade 60 with deformations in accordance with ASTM A-305. Welding of reinforcing bars is prohibited. 10. This design is intended for use at the address shown below and should not be used at other locations unless deemed suitable by a competent Professional Engineer. tr LJ > o 16"x16"x1" STEEL BASE PLATE 1^1 1/4" DIA. HOLE TYP. TS 6x2x1/4 2" DIA. HOLE ELEC. BASE PLATE DETAIL PARTICULAR CARE SHALL BE TAKEN TO PROVIDE SUFFICIENT PREHEAT OF THE THICKER ELEMENT FOR THE SOUNDNESS OF THE WELD. OTHERWISE. USE 5/15" MIN. WELD. 1" DIA. X 18 ANCHOR BOLT TS 6x2x1/4 LONG (4 REQ'D) 16"x16"xr' STEEL BASE PLATE HIGH STRENGTH. NON-SHRINK GROUT ANCHOR BOLT PROJECTION DETAIL MONUMENT MODEL M86 NOTE: Al iJni9ni ond ploni ndicolid on Ihis droKinq at Ihi idi ptopvly ol LMK EnqWittring, L.L.C, crtolid sp(ciricdl)p lor Ihi noltd piojicl. UH ot th«H dtjigns 0* ploni lor any purpoit oltwr Ihon Ihi inttndid oppltcotion ihdl b« ptotiibiltd vithoul tht >rilltn constnl ol LINK CnginMrin^, L L.C. Diicloturt ol ony ol Iht inlormolion tncloHd wilhin, ailhoul CDnitnl ol 0«ncr. it 0 viololion ol inlrticluQl protufty ond iMI not bl toltrolid. INSTALLATION ADDRESS: TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD. CA 9201 1 CLIENT: PATTISON SIGN GROUP iii ELLCSMCRC ROAO TORONTO. ONTARIO, CAN MIR 4C6 LINK Engineering, L.L.C. 9051 Executive Pork Dr.. Ste. 200 • Knoxville. TN 3792J Ptione: (865) 539-4001 • Fox; (865) 539-0851 Online: www.linkengr.com SHT. OF BY: JBL DATE: 03/10/09 Projflct Number: 09-0206 Drowing Nunnb.r: B132586 LONG (4 REQ'D) 6x3x1/4 I—2'-6" DIA.—1 ELECTRICAL CONDUIT (5) #4 BARS ON A 21" PATTERN WITH (4) §5 STIRRUPS @ 6" O.C. FOR TOP 18". THEN 14" O.C. THEREAFTER. 3" MIN. COVER, DO NOT WELD REBAR. tr LLJ > o \1 N z Q: 3 0.82 CU. YDS. CONC. REQ'D. OF 3 STIRRUP HOOK TYP. SECTION A-A OPTIONAL CAISSON FOUNDATION PROJECT* 09-0206 OWNER: TOYOTA CARLSBAD March 10, 2009 6020 AVENIDA ENCINAS DRAWING* Bl32586 CARLSBAD, CA 92011 WIND LOAD 16.267 PSF 1 WIND SPEED 86.000 MPH CLIENT: PATTISON SIGN GROUP # SUPPORTS 1.000 CBC 2007 555 ELLESMERE RD BIGINEER IK TORONTO, ONT. CAN M1R4B6 SHAPE CENTROID TOTAL PTEM HEIGHT WIDTH FACTOR HBGHT AREA FORCE MOMENT ======== ======== ======= ======== ======== ======== ======= ======== SIGN 5.333 8000 1.000 2.933 42.667 0.694 2.036 SIGN 0667 8.333 1.000 0.367 5.556 0.784 2.532 OAH 6.000 COLUMN STRESSES (CODES P=nPE,0=OTHER;T=TUBE) OBLIQUE Sxx COLUMN COLUMN Ixx Sxx ACTUAL ALLOWABLE ITEM MOMENT REQ'D DEPTH WALL COLUMN COLUMN STRESS STRESS ======== ======== ======== ======== ======= ======== ======== ======== ======== ======== ======== ======= ======== ======== SIGN 2.632 1.036 C6X8.2 0.188 13.1 4.38 4.994 23.760 BOLTCALCUUTIONS BOLT BOLTS/ TENSION/ BOLT ALLOW. ALLOWABLE ITEM I«1MENT SPACING PLATE BOLT DIAM. STRESS TENSDN ======= ======= ======= ======= ======= ======== ======= ======= ======= ======= ======= ======== BASE PL. 2.632 12.000 4.000 1.266 1.000 19.100 16.001 PLATE CALCULA TONS fTEM TENSION/ MOMENT MOMENT PLATE PUTE PLATE MINIMUM BOLT ARM PLATE WIDTH DEPTH THCK. THICK. BASE PL. 1.266 3.000 7.696 16.000 16.000 1.000 0.326 A NCHOR BOLT PROJECTDN A NGHOR MBEDMENT ANCHOR BOLT MIN.'' LENGTH 6.000 2.518 9.000 USE 18" BOLTS VERTICAL SLAB MOMENT 2 532 FT-KIP FORCE 0.784 KIP REFERENCE UBC 1806 & TABLE 18-l-A ASSUME SOIL CUVSS #4 SW,SP,SM,SC,GM&GC LATERAL BEARING PRESSURE- PSF/FTOF DEPTH 100.0 PSF/FT SI 266.7 SLAB DEPTH (d) 4.000 FT. SLAB WIDTH (b) 3.000 FT. SLAB THICKNESS 2.500 R. AVERAGE HEIGHT (h) 3.227 FT. A = 2.34'FORCE/(Srb) 1.763 CALCULATED DEPTH 3.523 FT. MINIMUM THCKNESS WITHOUT RfflAR 6.022 IN. SQRT(M*12*6*1.7*.75/(.178-12-WIDTH)) ACTUAL THICKNESS 30.000 IN. CONCRETE 1.111 CU. YD CAISSON MOMENT 2.532 FT-KIP FORCE 0.784 KIP REFERENCE UBC 1806 & TABLE 18-l-A ASSUME SOIL CLASS #4 SW,SP,SM,SC,GM&GC LATERAL BEARING PRESSURE - PSF/FT OF DEPTH 100.0 PSF/FT SI 300.0 DEPTH 4.500 FT. DIAMETER 2.500 FT. 3.227 FT. 2.447 FT. CALCULJ^ TED DEPTH 4.403 MINIMUM THICKNESS WfTHOUT RQNFORCB/IENT 15.064 FT. 1 IN. ACTUAL DIAMETER 30.000 IN. CONCRETE 0.818 CU. YD MONUMENT MODEL M86 NOTE: Al ((nigni ond ploni indkolad on Ihii drowing ort tht MII proptfly o( LINK Enqinitfing. L.L.C, Ctoltd tptciricdir lof Ihi nolad piojtcl. U« ol Ihtsi dasiqni or plons lor ony purpott olh<r thon lh| inlindid opplicolion shdl bt prohibiltd •ithoul Iht «rillin conitnl ol L>NK Enginftring, L.L.C. Diicloiurt ol ony ol tht inlormolion mckntd vilhir^, without COnitnl ol ownir, is o viololion ol jnUBtctuol pfoptrly ond thdl nol bt Idtrottd. 43520 INSTALLATION ADDRESS: TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD, CA 92011 CUENT: PATTISON SIGN GROUP 555 ELLESMCRC ROAD TORONTO, ONTARIO, CAN MIR ACS LINK Engineering, L.L.C. 9051 Executive Pork Dr.. Sle. 200 • Knoxville. TN 37923 Phone; (865) 539-4001 • Fox; (865) 539-0851 Online: www.linkengr.com OF BY: JBL DATE: 03/10/09 Project Number: 09-0206 Drawing Number: B132586 (8) 1/2" DIA. HOLE FOR 3/8" DIA. THREADED ROD W/ NUTS. FLAT, & LOCK WASHERS ^1 1/4" NOTES: 1. Design is based on 85 mph 3 second gust design wind speed per CBC 2007. Exposure C. 2. No additional wind catching surfoces are added to the building structure, the customer's building engineer is to determine the adequacy of the supporting structure. 3. Logo design by others. 4. All fasteners shall be zinc coated to prevent corrosion. 5. All wall penetrations shall be seoled to prevent water intrusion. 6. This design is intended to be installed at the address shown below and should not be used at other locations unless deemed suitable by a competent Professional Engineer. THE SCOPE OF THIS ENGINEER IS LIMITED TO THE AHACHMENT TO THE WALL. ALL OTHER ASPECTS OF THIS PROJECT ARE EXPLICITLY EXCLUDED. ELEVATION & MOUNTING LOCATIONS SECTION THROUGH CENTER 5/8" DENSGLASS ACM PANEL FORMED PLASTIC SIGN (8) 3/8" DIA. THREADED ROD W/ NUT, FLAT, &L LOCK WASHERS METAL STUD 16" O.C. DO NOT USE GRAPHICS SHOWN ON THIS DRAWING FOR PRODUCTION REFER TO PRODUCTION ELECTRONIC FILES 2"x2"x1 /8" STEEL PLATE WASHER 1/2" DIA. PIPE SPACER MOUNTING DETAIL HISTC All Oe»igns ond plans ndcoted oo dro-MQ we Ihe «ote praparlr ol LWK EnQinMr'nQ. LLC. creeled ipcclficoty *or Ihe noied pro^l. Use ol IhCM designs or plont for onjr purpose Other thon the irttMMM spplicalion shofi be proMbitcd •rithoul Ihc M-llten ceraml ol LMK £T>9r«er'n^ L.LC tl<>cla«Me ol any e.1 the inlormtrtior. endowd *i|hir\. wilhoul conMnt of oxter, it o violatiOA of aileHtctuol property ond shoM nol be loleroled. INSTALLATION ADDRESS: TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD. OA 9201 1 CUENT: PATTISON SIGN GROUP 555 eUXSHERE ROAD TORONTO. ONTARIO. CAN U1R 4E8 LINK Engineering, L.L.C. 9051 Executive Pork Dr.. Ste. 200 • Knoxville. TN 37923 Phone: (865) 539-4001 • Fox: (865) 539-0851 Online; www.linkengr.corr^ SHT. BY: JBL DATE: 03/10/09 Project Numben 09-0206 Drowing Mumben B132580 NOTES: FASTENER LOCATION (10 REQ'D) CMU WALL ELEVATION FASTENER LOCATION, TYP. 1. Design is based on 85 mph 3 second gust design wind speed per CBC 2007. Exposure C. 2. No additional wind catching surfaces are added to the building structure, the customer's building engineer is to determine the adequacy of the supporting structure. 3. Letters design by others. Electrical design by others. 4. All fasteners shall be zinc coated to prevent corrosion. 5. All wall penetrations shall be sealed to prevent water intrusion. 6. This design is intended to be installed at the address shown below and should not be used at other locations unless deemed suitable by a competent Professional Engineer. THE SCOPE OF THIS ENGINEER IS LIMITED TO THE ATTACHMENT TO THE WALL. ALL OTHER ASPECTS OF THIS PROJECT ARE EXPLICITLY EXCLUDED. 5/8" DENSGLASS TYPICAL SECTION 3/8" DIA. BOLT W/ NUT, FLAT, & LOCK WASHERS METAL STUD @ 16" O.C. 2"x2"xl/8" STEEL PLATE WASHER 1/2" DIA. PIPE SPACER D.E.F.S 5/8" DENSGLASS METAL STUD 16" O.C. MOUNTING DETAIIL @ LETTERS CMU WALL 3/8" DIA. ALL THREAD W/ NUT, FLAT, & LOCK WASHERS D.E.F.S. 1/2" DIA. PIPE SPACER MOUNTING DETAIIL @ LOGO 2"x2"xl/8" STEEL PLATE WASHER NOTE; AH desi9ns ond plans indicoted on Itiis drovinq ort Ihe sotc properly of LINK CnfmeerinQ, LLC, creoled *pec>ricoSy lor Ihe noted projKi. UM ol these dcvgrvt or pions lor ony purpose other Ihon the inlended opplicotion shaH bc prohibited wilKoul I'M Mitten consent of LINK Engineering LL.C. Disclosure o( ony of the Information enclosed within, irithout consent ol o>ncr, is a wioialian ot Intellectual properly and ihoH nol be tolerated. INSTALLATION ADDRESS: TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD, CA 9201 1 PATTISON SIGN GROUP SSS ELLESMERE ROAD TORONTO. ONTARIO. CAN MIR 4EB LINK Engineering, L.L.C, 9051 Executive Pork Dr.. Ste. 200 • Knoxville. TN 37923 Phone; (865) 539-4001 • Fox; (865) 539-0851 Online: www.linkengr.com SHT. BY: JBL DATE: 03/10/09 Project hJumbar: 09-0206 Drowing Number: B132577 FASTENER LOCATION- (TYP.) 10'-8 1/2" 3 FASTENERS (LETTER "A" & "L" ONLY) LU MINIMUM OF 4 FASTENERS PER LETTER (EXCEPT WHERE NOTED) 5/8" DENSGLASS 2"x2"xl/8" STEEL PLATE WASHER METAL STUD @ 16" O.C. THE SCOPE OF THIS ENGINEER IS LIMITED TO THE ATTACHMENT TO THE WALL. ALL OTHER ASPECTS OF THIS PROJECT ARE EXPLICITLY EXCLUDED. 1/2" DIA. PIPE SPACER NOTES: Design is based on 85 mph 3 second gust design wind speed per CBC 2007. Exposure C. No additional wind catching surfaces are added to the building structure, the customer's building engineer is to determine the adequacy of the supporting structure. Letters design by others. Electrical design by others. All fasteners sholl be zinc coated to prevent corrosion. All wall penetrations shall be sealed to prevent water intrusion. This design is intended to be installed at the address shown below and should not be used at other locations unless deemed suitable by a competent Professional Engineer. D.E.F.S 3/8" DIA. BOLT W/ NUT, FLAT, & LOCK WASHERS TYP SECTION THRU LETTER NOTE: All designs ond plons indicoted on this drowiriQ ore Ihe sole property of LMK Engineering. LLC, created specificoly ter Ihe noted project. Use of IhtM designs or plans for any ptM-pose other thon the intended opplicotion tfiol bc prohibited vilhout the arilten consent of LINK Engineering, LL.C. Oiscloswrc ol ony of Ihe infermotien enclosed vithin, Bithoul consent of owrwr, is o viololion ol inteWtcluol property ond shot not bc toitroied. INSTALLATION ADDRESS: TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD, CA 9201 1 PATTISON SIGN GROUP 555 EIXESMERE ROAD TORONTO. ONTARIO. CAN MIR 4E8 LINK Engineering, L.L.C. 9051 Executive Pork Dr.. Ste. 200 • Knoxville. TN 37923 Phone; (865) 539-4001 • Fox; (865) 539-0851 Online; www.linkengr.com JBL 03/10/09 Project Number: 09-0206 Drawing Number: Bl32576 \ • 1 MINIMUM OF 3 FASTENERS PER LETTER (EXCEPT WHERE NOTED) 5/8" DENSGLASS ACM PANEL 2"x2"x1/8" STEEL PLATE WASHER METAL STUD ® 16" O.C. 1/2" DIA. PIPE SPACER THE SCOPE OF THIS ENGINEER IS LIMITED TO THE ATTACHMENT TO THE WALL. ALL OTHER ASPECTS OF THIS PROJECT ARE EXPLICITLY EXCLUDED. NOTES: 1. Design is based on 85 mph 3 second gust design wind speed per CBC 2007. Exposure C. 2. No additional wind catching surfaces ore added to the building structure, the customer's building engineer is to determine the odequacy of the supporting structure. 3. Letters design by others. Electrical design by others. 4. All fasteners shall be zinc coated to prevent corrosion. 5. All wall penetrations shall be sealed to prevent water intrusion. 6. This design is intended to be installed at the address shown below and should not be used at other locations unless deemed suitable by a competent Professional Engineer. 3/8" DIA. BOLT W/ NUT, FLAT, & LOCK WASHERS TYP SECTION THRU LETTER N&lt; Ml Pe«gns an« ptons in^oVcd or, \tm d>oi^ ere the solt property el LMK Engineering. LLC. creeled ipec>fico>r lor the noted projecl. Use ol these dcsigrts er plans fer any purpose other than |he ktlended epplieation shaH be prohibiled wilhout the written consent of LtPM Engineering. LLC Disclosure ol eny of Ihe inlormolion enclosed within, irithout consent of owner, is e viololion of kitetlecluol property ond sho* not be tolereled. INSTALLATION ADDRESS: TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD, CA 92011 CUENT: PATTISON SIGN GROUP 555 ELLESMERE ROAD TORONTO. ONTARIO. CAN MIR 4EB LINK Engineering, L.L.C. 9051 Executive Pork Dr.. Ste. 200 • Knoxville. TN 37923 Phone; (865) 539-4001 • Fox; (865) 539-0S51 Online; www.Iinkengr.com SHT. BY: JBL 03/10/09 Project Number: 09-0206 Drawing Numben B132579 FASTENER LOCATION- (TYP.) 14'-5 1/4" 2 FASTENERS (LETTER "1" ONLY) MINIMUM OF 3 FASTENERS PER LETTER (EXCEPT WHERE NOTED) 5/8" DENSGLASS ACM PANEL 2"x2"x1/8" STEEL PLATE WASHER METAL STUD ® 16" O.C. 1/2" DIA. PIPE SPACER THE SCOPE OF THIS ENGINEER IS LIMITED TO THE ATTACHMENT TO THE WALL. ALL OTHER ASPECTS OF THIS PROJECT ARE EXPLICITLY EXCLUDED. NOTES: 1. Design is based on 85 mph 3 second gust design wind speed per CBC 2007. Exposure C. 2. No additional wind catching surfaces are added to the building structure, the customer's building engineer is to determine the odequacy of the supporting structure. 3. Letters design by others. Electrical design by others. 4. All fasteners shall be zinc coated to prevent corrosion. 5. All wall penetrations shall be sealed to prevent water intrusion. 5. This design is intended to be installed at the address shown below and should not be used at other locations unless deemed suitable by a competent Professional Engineer. 3/8" DIA. BOLT W/ NUT, FLAT. & LOCK WASHERS TYP SECTION THRU LETTER NOTL: All designs ond plons indicoted on Ihis drowing ore the sole properly of UMK Engifteering. LL.C, creeled ipeciricoty for Ihe noted project Use ol these designs er pMtnt ior ony purpose other than Ihe intended opplicolion shoU be prohibited wthoul the written censent of LINK Engineer^ LL.C Disclosure ol eny of Ihe inlormolion ertdosed wilhir\, without consent ol owner, i* o viololion ol inldtectuol property ond shoB nol be Ideroled. INSTALLATION ADDRESS: TOYOTA CARLSBAD 6020 AVENIDA ENCINAS CARLSBAD, CA 92011 CUENT: PATTISON SIGN GROUP 555 ELUSMERE ROAD TORONTO. ONTARIO, CAM WlR 4EB LINK Engineering, L.L.C. 9051 Executive Pork Dr.. Ste. 200 • Knoxville. TN 37923 Phone; (865) 539-4001 • Fox; (665) 539-0851 Online: www.Hnkengr.com BY: JBL DATE: 03/10/09 Project Numben 09-0206 Drowing Numben Bl32578 555 Ellesmere Ftoad Toronto, Ontario, Canada MIR 4E8 Tel (416) 759-1111 Fax C416) 759-4965 Toll Free 1-800-268-6536 www.pattisonsign.com A Division of Jim Pattison Industries Ltd. 21-JAN-09 Date NOTTO SCALE Scale A. Jackson /A. Hollyoak Sales Rep 09 0100 Design No. C. Calder Designer Revision Note Job No. All rights reserved. No part of tliis drawing may be reproduced in any form without written permission fram Pattison Sign Group. It is agreed that the client is entirely responsible to install the concrete base as per Pattison Sign Group technical drawings or the equivalent. Where an existing base is used, the client agrees to check if the concrete base can support the sign as supplied by Pattison Sign Group. Pattison Sign Group will not accept uny liability. Voltage: Diaovolt • SptcOf'tdB^rtnL 2i ••*(. i fz, m t \J K A r< 3 b 11? N A C,33 fc EAST ELEVATION ^ EQ ^ 14'-5 1/4-^ EQ ^ ^ EQ ^ 14'-S1/4-^ EQ ^ SL72 TDN-2i 12'-71/16" 10"-81/2" I 1 I 1 I 4'-0" GARLSBAD ill'.^' WEST ELEVATION 5i' 15 4'-6 1/2" I—I 1