Loading...
HomeMy WebLinkAboutPS 09-49; Board and Brew; Sign Permits/Programs (PS)City ofCarlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING REC'D DATE PLICATION #_J^P3JI43_ SIGN FEE '^^i^-^ SIGN PROGRAM FEE. RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: j^at-tJ % (^s^W ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER: RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (b) Commercial (c) Office/Industrial (d) Hotel/Motel (e) Service Station (f) Prof Care (g) Theater (h) Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesCg-'^No • VILLAGE REDEVELOPMENT AREA YesQ No • SIGN ORDINANCE: Specific Plan Number Requires VR Approval COASTAL ZONE: YesD No • YesD No • ***** Form 10 Revised 3/08 Page 1 of 4 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wail Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes • PROPOSED PERMANENT SIGNS: No • Date TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** Monument** Wall 'A Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Formic Revised 3/08 Page 2 of4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building/s P/L Show all property lines P/L ^ Sight Distance Requirement a Show setbacks from all curbs curb line Sight Visibility Street Name(s) 0 North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. Formic Revised 3/C8 Page 3 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN 2o. ft. sq. ft. sq. ft. sq. ft. 1 sq. ft. sq. f^. PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT, \ OR TYPE) , MAILING ADDRESS MAILING ADDRESS ^a2<)^ ^.i lp. U # ^r^' lAfi CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. / / — H/?.*/<r SIGNATURE DATE SIG^ATIJRE^ DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •> In right-of-way • In visibility triangle at comer 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved route copy to Data Entry / /^^ Date: 4(>M APPROVED: Planner: ********* Formic Revised 3/08 ******** Page 4 of 4 City of Carlsbad Faraday Center Faraday Cashiering 001 0912001-3 04/30/2009 32 Thu, Apr 30, 2009 04:03 PH Receipt Ref Nbr: R0912001 PERMITS PERMITS [fan Ret Nbr; 091200103 003/ 0039 Trans/Rcpt#: R0074581 SET #; PS090049 Amount: 1 @ $56.00 Item Subtotal; $56.00 Item Total: $56.00 PERMITS - PERMITS Iran Ref Nbr; 091200103 0037 0040 Trans/Rcpt#; R0074582 SET #; PS090050 Amount: 1 i$ $56.00 Item Subtotal: $56.00 Item Total: $56.00 PERMITS - PERMITS Tran Ref Nbr; 091200103 0037 0041 Trans/Rcpt#: R0074583 SET #: CB090?i9 Amount: 1 (I $134.33 Item Subtotal; $134.33 Item Total: $134.33 PERMITS - PERMITS Tran Ref Nbr; 091200103 0037 0042 Trans/Rcpt#: R0074584 SET #; CB090720 Amount; 1 $134.33 Item Subtotal: $134.33 Item Total: $134,33 4 ITEM(S) TOTAL: $380.66 Check (Chk# 3601) $380.66 Total Received: $380.66 Have a nice day! .p****:t,********CUST0MER COPY******++**+=t-* City of Carlsbad 163 5 Faraday Avenue Carlsbad CA 92008 illllllll Applicant: ALIANO JOEY Description PS090049 2 6 75 GATEWAY RD CBAD Amount 56 . 00 Receipt Number: R0074581 Transaction Date: 04/30/2009 Transaction ID: R0074581 Pay Type Method Description Amount Payment Check 56.00 Transaction Amount: 56.00 city of Carlsbad 163 5 Faraday Avenue Carlsbad CA 92008 Applicant: ALIANO JOEY Description PS090050 26 53 GATEWAY RD CBAD Amount 56 . 00 Receipt Number: R0074582 Transaction Date: 04/30/2009 Transaction ID: R0074582 Pay Type Method Description Amount Payment Check 5 6.00 Transaction Amount: 56.00 iiOK ILLUMI\ATED irtp; SPtCIAL r¥ SANDWICH NEW SINGIE FACED INTERNALLY ILLUMINATED PLEX FACED CHANNEL LETTER DISPLAY WITH THROUGH FACE AND HALO ILLUMINATION (MAKE TWO) US^STANDARU ALUMHUM COII.STRIICTUJW WITH KlAHHtWS bAIIN AGRi'LIt K1YURETH.AME rilJISH fACFS USE ••/73:3 WMITi: alX WTH AFTOFO L'lUIIAI.LY -RWItO VINYL OVFKLAV ILUIMINATE WITiH 30 mo UL 6ii WHITE HEC'N THROUGH FACE AND HALO PAIHI Rt1UR:iS ANO 3.'4 IRIM CAP Kl MATCH PMS * 1780 U SECONDARY COPY L060 IWmil F fACES aw #7328 WHITt PlEX WITH A^PLItO IIIOnALlY PRINTcO VINY. i)VfRlA^ ILLUMIMATE WITH 30 ma CL 65 WHITE NEON THROUGH FACE AMC rIAI.O PAIMT RETURNS ANO 3,"|- TRIM CAP TO MATCH PMS # 1785 U TOTAL 10 SQ. FT PER ELEVATION £j«x-ev>i HAMC iik-r*r> FED iPiP ' 11 PLEX FACED CHANNEL LETTERS THROUGH FACE AMD HALO ILLUMINATION BONDING t CnOUUDING REO'O PER ARTICU COD OF UL SAM NEOII TO HAVE AT LEAST 1;C CIEARABCE FROM ALUMINUM 20'-0- LEASED STOflEFWHT ] CENTER OVER STOREFRONT VERIFY VERTICAL PLACEMENT OPTION #1 joi mmmuiOM MUD I MEW XBTSUTIWnrMM) SUITE #in CAIIl«UB,M«108 PBfli'jisa^fao.NifLEmoN -. sciiE;jy4::Hi>o:' MUSTEHM KiteeoKi KtKMII TUOEinM nm» M WMUU1 MTE n-iz-zoN VOUUf VERIFY tUtllT APrRDVAL Page 2 of 4 MIS MLH* MINK, sn ISS s«iiwu,e< uni.ica ©2 ^ m^^^'^W W*'**^" »?«!*.-«^ 0Xfm^m%. -i&V-**. EROf OSEPAEAftiLiSAIiaN _ S£AU.:W=TJ!!': OPTION A- • PERSPECTIVE B>?*rf:V«r~ 1 I 2 VVIDF FIAT BAR ACCENl WITH POWDER COATED BLACK FINISH 1.4 S I' WIDE MOUNTING I'LATE WITH POWDER COATED BLACK FINISH 1 1 2 HORIZOMTAI SUPPUR> WITII POWDER COATED BUCK FINISH f^TAlHLEdS SI EEL ^ I AIRCRAFT CABLE UIMENSIOHiV- COPY • Q -0 FR. F;M. GRADf MfiM-ll IIIMIMATED BLADE SIGN SCALE: 3/4" = 1-0" USTFLAT CUT OUT IV SINTRA WITH 1/4" SINTRA AND APPLIED DIGITALLY PRINTED VINYL GRAPHICS JM WEMtlunOII MUUUI«MEW sinn«iia CARUnM,CR»2108 lAUtmten uaetoPH OEUSNER TUCKHYK (UTCK NO uuuti MTE 0M2-2tn VOIIACE VERIFY CLIENT tPPROVAL Page 4 of 4 m: •H-SU-14M m: IH-Stl-14S3 MltMUOA AVEMIE. SR ISB s«iiiiui),c« nin-isM •H-t.-'!Tv 1 i Z BRESSI RANCH VILLAGE CENTER EL FUERTE AND GATEWAY STREET CARLSBAD. CALIFORNIA CHILDS MASCAISl WARNER ^rch)t*ctt r 1'-6' 0'-8 1/4" 2'-0' 0'-6' 8'-10" 7'-0" SPf-CIALTY 3ANDW/CHE3 NON ILLUMINATED (TYP) JOB INFORMATION BOARD & BREW 2675 GATEWAY ROAD SUITE #103 CARLSBAD, CA 92108 SALESPERSON REID COOPER DESIGNER TRACIE HYDE SKETCH NO B0ARD&G1 NEW SINGLE FACED INTERNALLY ILLUMINATED PLEX FACED CHANNEL LETTER DISPLAY WITH THROUGH FACE AND HALO ILLUMINATION (MAKE TWO) SCALE: 1"=1'-0" USE STANDARD ALUMINUM CONSTRUCTION WITH MATTHEWS SATIN ACRYLIC POLYURETHANE FINISH, FACES USE #7328 WHITE PLEX WITH APPLIED DIGITALLY PRINTED VINYL OVERLAY ILLUMINATE WITH 30 ma CL 65 WHITE NEON THROUGH FACE AND HALO, PAINT RETURNS DARK BRONZE AND 3/4" TRIM CAP TO MATCH PMS # 1785 U. SECONDARY COPY LOGO MODULE: FACES USE #7328 WHITE PLEX WITH APPLIED DIGITALLY PRINTED VINYL OVERLAY ILLUMINATE WITH 30 ma CL 65 WHITE NEON THROUGH FACE AND HALO, PAINT RETURNS DARK BRONZE AND 3/4" TRIM CAP TO MATCH PMS # 1785 U TOTAL: 10 SQ. FT PER ELEVATKJN T/M PMS #3275 T/M PMS #1785 ALUMINUM CHANNEL TRIM CAP PLEXFACES WHITE LEXAN BACKS NEONTUBE WEEPHOLES - FACIA - 4'RETURNS 1-3/6-PEG OFFWALL NSTALL WITH 3 1/8" X 3-1/2" SCREWS NTOPLASTICANCHORS 1/8X2" LAGS I NTO EXPANSION SHIELDS ALUMINUM RACEWAY GT0-15WIRE TRANSFORMER DISCONNECTSWITCH ELECTROBITS 3/4'CONDUITTHRUWALL SECTION SIGN TO BE UL APPROVED AND BEAR UL LABEL PLEX FACED CHANNEL LETTERS THROUGH FACE AND HALO ILLUMINATION BONDING & GROUNDING REQ'D PER ARTICLE 600 OF UL SAM NEON TO HAVE AT LEAST 1/4" CLEARANCE FROM ALUMINUM 1 / APRIL 17, 2009 • REVISED RETURN COLOR DATE 01-12-2009 VOLTAGE 120v VERIFIED PRIMARY ELECTRICAL TO SIGN LOCATIONS IS TO BE PROVIDED BY OTHERS 20 AMP DEDICATED CIRCUiT(S) WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATIONS COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF ULTRASIGNS IT CANNOT BE REPRODUCED, COPIED OR EXHIBITED IN WHOLE OR PART WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM ULTRASIGNS THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REOUIREMENTS OF ARTICLE 600 OF THE NATIONAL ElEGTTOGAL CQOE AND/OR OTHER APPUCABLE LOCAL CODES THS (tiaUDES PROPER GROUHOmG AND BONBWG OF THE 3GN REVISION DATES 04-17-2009 04-22-2009 DAG CLIENT APPROVAL Page 1 of 5 TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SAH DIEGO, CA 92123-1520 BOTTOM OF SIGN EXPANSION JOINT 2G"-0" LEASED STOREFRONT "•1 CENTER OVER DOORS o PROPOSED FRONT ELEVATION SCALE: 1/4"=1'-0" JOB INFORMATION BOARD & BREW 2675 GATEWAY ROAD SUITE #103 CARLSBAD, CA 92108 SALESPERSON REID COOPER DESIGNER TRACIE HYDE SKETCH NO B0ARD&01 DATE 01-12-2009 VOLTAGE 120v VERIFIED PRIMARY ELECTRICAL TO SIGN LOCATIONS IS TO BE PROVIDED BY OTHERS 20 AMP DEDICATED CIRCUIT(S) WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FDR ALL INSTALLATIONS. COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY COLOR CALL-OUTS ARE K)R A MATCH AS CLOSE AS POSSIBLE. THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF ULTRASIGNS. IT CANNOT BE REPRODUCED COPIED OR EXHIBITED IN WHOLE OR PART WITHOUT FIRST OBTAINING WRinEN CONSENT FROM ULTRASIGNS THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES THS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN REVISION DATES 04-17-2009 ^ 04-22-2009 DAG <r, CLIENT APPROVAL Page 2 of 5 TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SANDIEGO, CA 92123-1520 02 CENTER OVER GLAZING PROPOSED REAR ELEVATION SCALE: 1/4"=1'-D" JOB INFORMATION BOARD & BREW 2675 GATEWAY ROAD SUITE #103 CARLSBAD, CA 92108 SALESPERSON REID COOPER DESIGNER TRACIE HYDE SKETCH NO B0ARD&01 DATE 01-12-2009 VOLTAGE 120v VERIFIED PRIMARY ELECTRICAL TO SIGN LOCATIONS IS TO BE PROVIDED BY OTHERS 20 AMP DEDICATED CIRCUIT(S) WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FDR P.L INSTALLATIONS COLORS REPRESENTED IN THIS DRAVIflNG ARE FOR PRESENTATION PURPOSES ONLY THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF ULTRASIGNS IT CANNOT BE REPRODUCED COPIED OR EXHIBITED IN WHOLE OR PART WITHOUT RRST OBTAINING WRITTEN CONSENT FROM ULTRASIGNS. THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. REVISION DATES 04-17-2009 04-22-2009 DAG Cn CLIENT APPROVAL Page 3 of 5 TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SANDIEGO, CA 92123-1520 r-9" BRACKET TO BE PROVIDED BY LANDLORD DIMENSIONAL COPY 2'-11 " NON-ILLUMINATED BLADE SIGN SCALE: 3/4 " = 1-0 " USE FLAT CUT OUT 3/4" SINTRA WITH 1/4" SINTRA AND APPLIED DIGITALLY PRINTED VINYL GRAPHICS T/M PMS #3275 T/M PMS #1785 JOB INFORMATION BOARD & BREW 2675 GATEWAY ROAD SUITE #103 CARLSBAD, CA 92108 SALESPERSON REID COOPER DESIGNER TRACIE HYDE SKETCH NO B0ARD&01 DATE 01-12-2009 VOLTAGE 120v VERIFIED PRIMARY ELECTRICAL TD SIGN LOCATIONS IS TO BE PROVIDED BY OTHERS 20 AMP DEDICATED CIRCUIT(S) WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR ALL INSTALLATIONS. COLORS REPRESENTED IN THIS DRAWING ARE FDR PRESENTATION PURPOSES ONLY THEY MAY NOT MATCH YOUR HNISHED PRODUCT PERFECTLY COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE THIS ORIGINAL DESIGN IS THE SOLE PROPERPl' OF ULTRASIGNS. IT CANNOT BE REPRODUCED, COPIED DR EXHIBITED IN WHOLE OR PART WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM ULTRASIGNS THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTCLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN REVISION DATES 04-17-2009 ^ 04-22-2009 DAG ^ w (iro CLIENT APPROVAL Page 4 of 5 TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SAN DIEGO, CA 92123-1520