Loading...
HomeMy WebLinkAboutPS 10-131; Flooring America; Sign Permits/Programs (PS)m REVIEW FOR SIGN Development Services m PERMIT Planning Division CITY OF P-11 1635 Faraday Avenue CARLSBAD P-11 (760) 602-4610 www.carlsbadca.gov PLANNINGAPPLICATJON # IO-I3I RECD BYOk^A Aoy^^ > DATE /l-IO-(d) SIGN FEE ff.Sto SIGN PROGRAM FEE RECEIPT NO. All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPUCANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: lp\oC>V"lVV(^(^Vv\^gj^UL^ ADDRESS OF PROJECT: '~2-^\^ (^Sj^-W^g^ A ASSESSOR PARCEL NUMBER: ^\^^U^>> \^ RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) Theater (j) Produce Stand ^•{t>)~~N.Commercial (e) Service Station (h) Gov't/Church (k) Nursey C (c)>«ffice/lndustnal (f) Prof. Care (i) Public Park (I) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesD NoD Specific Plan Number VILLAGE REDEVELOPMENT AREA YesD NoD Requires VR Approval p-11 Page 1 of 4 Revised 07/10 SIGN ORDINANCE: YesD NoD COASTAL ZONE: YesD NoD EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: YesD NoQ PROPOSED PERMANENT SIGNS: Date TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** Monument** Wall \ Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner **Prlor to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach Into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. p-11 Page 2 of 4 Revised 07/10 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign pemnit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building/s P/L Show all property lines P/L , Sight Distance Requirement I Show setbacks from all curbs curb line Sight Visibility Street Name(s) 0 North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN. p-11 Page 3 of 4 _sq. ft. . sq. ft. . sq. ft. . sq. ft. sq. ft. sq. ft. Revised 07/10 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) *^^vJoV '^^i^^ V\ V v\0{JX^ NAME (PRINT OR TYPEJ MAILING ADDRESS MAILING ADDRESS CITY AND STATE ZIP ^ TELEPHONE CITY AND STATE ZIP TELEPHONE 1 CERTIFY THAT 1 AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. 1 CERTIFY THAT 1 AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THEBEST OF- MY KNOWLEDGE. SIGNATURE DATE SIGRATURE ^ DATE PLANNER CHECK LIST 1. 2. 3. 4. 5. 6. Field check by planner. Within maximum length, area. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. Location: • In right-of-way • In visibility triangle at corner Pole and monument signs to be checked by Transportation Engineering, for visibility issues. When approved route copy to Data Entry : &l4id AeiUrv^ Date: n-in-/^ APPROVED: Planner: p-11 Page 4 of 4 Revised 07/10 City of Carlsbad Faraday Center Faraday Cashiering 001 1031401-1 11/10/2010 32 Wed, Nov 10, 2010 01:11 PM Receipt Ref Nbr: R1031401--1/0005 PERMITS - PERMITS Tran Ref Nbr; 103140101 0005 0005 Trans/Rcpt#; R0081871 SET #: PS100131 Amount: 1 @ $56.00 Item Subtotal: $56.00 Item Total: $56.00 1 ITEM(S) TOTAL: $56.00 Credit Card (Auth# 175409) $56.00 Total Received: $56.00 Have a nice day! **************C[JST0MER COPY************* City of Carlsbad 163 5 Faraday Avenue Carlsbad CA 92 008 Applicant: SWOISH TIM Description PS100131 2 718 GATEWAY RD CBAD Amount 56 . 00 Receipt Number: R0081871 Transaction Date: 11/10/2010 Transaction ID: R0081871 Pay Type Method Description Amount Payment Check 5 6.00 Transaction Amount: 56.00 REVISE&RESUBMIT • PRODUCTION MGR APPROVAL • 24" '0-13 MIRAAAAR K Sigh ^orks APPROVED • PRODUCTION APPROVAL 90 40KenamarDr.Suite403»SanDlego,CA92121 rvAfTTP (1)858.566.301 0>.(f)858.566.3080 • • ... www.miramarsignworKs.com FlooringAmerica 40.33 SQUARE FEET PER SIGN nirUetfpnr** Hf^cinn. inr by picketfence design, inc~h |^ ^^2" 17 1/2" 3 1/4" MANUFACTURE & INSTALL: ONE (A) SET OF HALO LIT REVERSE PAN CHANNEL LETTERS & SECONDARY COPY "FLOORINGAMERICA": FACES: ALUMINUM FABRICATION RETURNS: 3" DEEP ALUMINUM FINISH: DURANODIC BRONZE PER CRITERIA ILLUMINATION: WHITE LEDs AS REQUIRED ALUMINUM RETURN & LETTER BACKS: U.L. APPROVED CLEAR LEXAN FACE LETTERS SHALL BE PEGGED OFF FASCIA 1 1/2" STAND-OFFS SHALL BE PAINTED TO MATCH FASCIA COLOR -050 ALUMINUM CLIPS REMOTE POWER SUPPLIES SCALE: 3/8" = r-O" .1 1/2" "by picketfence design, inc.": 1/4" THICK FLAT CUT OUT ALUMINUM, PAINTED DURANODIC BRONZE LETTERS SHALL BE STUD MOUNTED TO FASCIA - FLUSH MOUNT LED ILLUMINATION CLEAR LEXAN BACK SPACER POWER SUPPLY PRIMARY ELECTRICAL (RESPONSIBILITY OF OTHERS) U.L. APPROVEO INSTALLATION DETAIL: HALO-LIT REVERSE PAN CHANNEL LETTER WITH LED ILLUMINATION SHEET 1 0(4 FlooringAmerica SanDiego,CA CLIENT Flooring America CONTACT Dan Taylor DRAWING TITLE Sign Type : Reverse Pan Channel Letters REVISION RS: 9.3.10 FlooringAmerica SanDiego,CA DATE 6.14.10 JOB# Pre-Salo SALES PERSON O. Oodoy DESIGNER T.Thomsen This design concept Is submlttsd only for your approvsl or rsvlsw snd is sxclusivs propsrty of M Irs mar Sign Works & Graphics. This concept may not be copied, rep rod ucsd, exhibited or utilizsd for any purpose, in part or in whole by any Individual inside or out without written consent of Miramar Sign Works & Graphics. Our renderings are good-faith attempts to illustrate an accurate repressntatlon of the final product, Miramar Sign Works & Graphics cannot be held responsible for differences between renderings and the finished product caused by monitors, printers or environmental lighting. REVISE&RESUBMIT • PR OD U CTI O N M G R AP P R OVAL MIRAMAR V\ Sigh morks APPROVED • PRODUCTION APPROVAL 9040KenamarDr.Suite403» SanDiego.CA92121 (1)858.566.301 0->(f)858.566.3080 www.miramarsignworks.com EQ 24" EQ EQ 20'-2" EQ Ul—1 TlooringAmerica BUILDING "H" WEST ELEVATION SCALE: 1/16" = r-O" Approved by the SpectrumFlex OA Board as proposed. Paul Danninger As managing agent for the SpectrumFlex OA. 09.22.2010 SHEET 2 0(4 FlooringAmerica SanDiego,CA CLIENT Flooring America CONTACT Dan Taylor DRAWING TITLE Sign lype : Reverse Pan Channel Letters REVISION RS: 9.3.10 FlooringAmerica SanDiego,CA DATE 6.14.10 JOB# Pre-Sale SALES PERSON 0. Qodoy DESIGNER T.Thomsen This design concept is submitted oniy for your approval or review and is sxclusivs propsrty ofMlrsmarSIgn Works & Graphics. This concept msy not bs copied, reproduced, sxh ibited or utilized for any purpose. In part or In whole by any Individuai inslds or out without written conssnt of Miramar Sign Works & Graphics. Our rsndsrings srs good-faith attsmptsto lliustrats an accurate representation ofthe finai product, Miramar Sign Works & Graphics cannot be held responsible for differences between renderings and the finished product caused by monitors, printers or snvironmental lighting. • REVISE&RESUBMIT • PRODUCTION MGR APPROVAL MIRAAAAR Sig/h]^orks • APPROVED • PRODUCTION APPROVAL 9040KenamarDr.Sulle403»SanDlego,CA92l21 (1)858.566.301 0.(f)858.5663080 www.miramarsignworks.com NORTH S Geologicsl Surv SHEET 1 0(4 FlooringAmerica SanDiego, CA CLIENT Flooring America CONTACT Dan Taylor DRAWING TITLE Sign Type : Reverse Pan Channel Letters REVISION FlooringAmerica SanDiego, CA DATE JOB# SALES PERSON DESIGNER R5: 9.3.10 FlooringAmerica SanDiego, CA 6.14.10 Pre-Sale O. Oodoy T.Thomsen This design concept Is submitted only for your approval or review and Is exclusive property of Miramar Sign Works & Graphics. This concept may not be copied, reproduced, exhibited or utilized for any purpose, in pert or In whole by any Individual inside or out without written consent of Miramar Sign Works & Graphics. Our renderings are good-faith attsmptsto lliustrats an accurate repressntatlon of the final product, Miramar Sign Works & Graphics cannot be held responsible for differences between renderings snd the finished product caused by monitors, printers or environmental lighting.