Loading...
HomeMy WebLinkAboutPS 10-21; Carlsbad Research Center; Sign Permits/Programs (PS)^ CITY OF CARLSBAD REVIEW FOR SIGN PERMIT P-11 Development Services Planning Department 1635 Faraday Avenue (760) 602-4610 Nwww.carlsbadca.gov PLANNING APPL REC'D BY , _ DATE 4 SIGN FEE SIGN PROGRAM FEE RECEIPT NO. KION# RECEIVED m G1 m CITY Of CARLSBAD PLANNING DEPT - - All plans submitteci for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to tho property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for ail proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materiais the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4.00 p.m. Average processing time: 2 weeks NAME OF PROJECT: Carlsbad Research Center Entry Monument Sign No. 3 ADDRESS OF PROJECT: East side of College Boulevard adjacent to 1817 Aston Avenue ASSESSOR PARCEL NUMBER: 212-120-11-00 RELATED PLANNING CASE NUMBER{S):, TYPE OF DEVELOPMENT: (a) Residential (d) (b) Commercial (e) (Jg) Office/Industrial (f) SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Hotel/Motel (g) Service Station (h) Prof. Care (i) Theater Gov't/Church Public Park (j) Produce Stand (k) Nursey (1) P-U/OS Zone YesI VILLAGE REDEVELOPMENT AREA YesQ NoQ Specific Plan Number 180 (E) NoH Requires VR Approval p-11 Page1 of 4 Revised 04/09 SIGN ORDINANCE: YesB HoU COASTAL ZONE: YesD NoH EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: YesD NoD PROPOSED PERMANENT SIGNS: Date TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) 1 1 50 SF 36 SF 5 Ft. 3 Ft. PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. p-11 Page 2 of 4 Revised 04/09 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Sign not at an intersection Sliowbuilding/s Show afl property lines 1 ^ Sight Distance H.eqiiirement ' c I o Show setbacks from all curbs L I c curb line Sight "Visibility Street 'Name(s) Of- 0 Worth 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. 50 None EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE N/A TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN P-11 Page 3 of 4 50 36 14 _sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. Revised 04/09 PROPERTY OWNER APPUCANT NAME {PRINT OR TYPE) Jetl and Jones LLO NAME (PR^NTORTYPE) Seth Schulbers- Planning Systems MAILING ADDRESS [3640 Sagunto St suite 301 MAILING ADDRESS 1530 Faraday Avenue CITY AND STATE ZIP TELEPHONE Santa Ynez, CA 93460 805-693-1314 CITY AND STATE ZIP TELEPHONE Carlsfaad, Califomia 92008 760-931 -0780 X 108 1 CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATIOM IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE, \ CERTIFY THAT 1 AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. .TA^" .7^AC,£ ^/^I7 rsteNATURfe/ DATE SieNATLiRE jy^ DATE j PLANNER CHECK UST: 1. 2. 3. 6. 6. Ffeld check by planner. Within mexlmum length, area. Style consiatent with Sign Program and/or Specific Pian criteria, if applicable. Location; (n right-of-way <* In visibility Wangle at corner Pole and monumsnt signs to be checked by Traffic Engineering, for visibiiity issues. When approved route cppyj^ Data^^^^^^^ APPROVED: Planner:. Date RECEIVED APR G1 CITY OF CARLSBAD PLTP^mUQ DEPT Pi»g64rJf4 Revised 04/C9 City of Carlsbad Faraday Center Faraday Cashiering 001 1009101-2 04/01/2010 96 Thu, Apr 01, 2010 03:22 PM Receipt Ref Nbr: R1009101-2/0035 PERMITS - PERMITS Tran Ref Nbr: 100910102 0035 0042 Trans/Rcpt#: R0078811 SET #: PS100021 Amount; 1 i $56,00 Item Subtotal; $56.00 Item Total: $56.00 1 ITEM(S) TOTAL; $56.00 Check (Chk# 001600) $56.00 Total Received: $56.00 Have a nice day! **************CUSTGMER COPY************* city of Carlsbad 1635 Faraday Avenue Carlsbad CA 92 008 Applicant: SETH SCHULBERG Description PS100021 Amount 56 . 00 Receipt Number: R0078811 Transaction Date: 04/01/2010 Transaction ID: R0078811 Pay Type Method Description Amount Payment Check 56.00 Transaction Amount: 56.00 J 30'-Q" Common i I j I* Area Maintenance ' ^ ^ ii FIBER ROLL (typ. sym.) Mow Curb (Typ. Sym.) CUT MATERIAL - Dark Shaded Areas (typ. sym.) ).B. for mow curb layout MONUMENT SIGN LOCATION (P.O.B.) From curb return at intersection, proceed north 233 ft., [and stpke ( I sign corner 10'-2" fronn'face pf curb Sign fin. gd. @ 18" above sidevvilk on level pad area approx. 18" wide Dot pattern sfiows work zone (typ. sym.) FILL MATERIAL Ligther Shaded Areas (typ. sym.) 31LT FENCE typ. sym.) R.O.W. . 3;5'-0" Cpmmqn I Arfea Mairitenarlce r March 12, 2010 NORTH 2) 3) 4) 5) 6) Sign Project Installation Notes: 1) Surveyor shall coordinate with utility to precisely stake utility easement on both sides of road. Landscape contractor shall install silt fencing around entire downhill perimeter of work zone, and install fiber rolls along entire sidewalk edge of work zone. Sign contractor shall demo and grub out all remaining plants in the work area. Landscape contractor shall demo all irrigation in the work zone except for equipment to remain undisturbed (as per Faraday West Landscape Improvements, Planning Systems, 3-12-10). Sign contractor shall install vinyl sign outside ofthe R.O.W. and as per the plans. Point of beginning shall be 233 ft. from BOC at College and Palomar Point. Once Architect has provided approval to proceed. Surveyor (under separate contract) shall stake sign corners and the mow curb locations. Sign shall be located outside of R.O.W. Sign Pad - Contractor shall cut and fill to create a level sign pad that extends from 12" to 18" around sign perimeter. A bench that slopes at approximately 5% shall also be created that trends along the R.O.W. from north to south along the length of the graded area. Compact to 90%. Graded area is approx. 2000 s.f. in size. West Side Planting Bed - Contractor shall cut and fill to create a sloping planting bed with a 3:1 slope at the rear edge ofthe common maintenance area. Compact to 90%. Graded area is approx. 1900 s.f. in size. Surveyor shall spot check aii grading and assist Sign contractor in creating a slope grade does not exceed 2:1, that turf grading does not exceed 3:1. Sign contractor shall excavate and compact soil beneath footing per industry standards. Sign contractor shall install permanent monument sign per Carlsbad Research Center Monument Sign, by Stuart White Design, dated 04-25-05, except as amended by this plan. Landscape contractor shall install new irrigation, and completely replant and re-mulch all areas disturbed by project as per the Faraday West Landscape Improv^ Systems, 3-12-10. 8) 9) 10) 11) 12) Plan Notes: 1) Topographical base information per City of Carlsbad electronic file dated 2003 deemed approximate but not field confirmed. 2) All easements and structures shall be located prior to beginning work. 3) See Carlsbad Research Center Monument Signs 04/25/05, page 6 for Elevation view. Grading Notes: 1) Grading sh 2) No cut or fiill exceed 3-1/2 ft. vertical'dept deepest point from the existing ground surface. 3) The new toe of slope is no closer than one foot to the edge of the CRC common maintenance area. 4) The amount of soil material moved to create a pad to install the sign does not exceed one hundred cubic yards. 5) On the west side of the road, less than 30 cy. of soil movement is proposed for landscape embellishment purposes only. This work is not essenfial to the success ofthe landscape installation. Figure 3 of 3 College South Sign Improvement Plan Carlsbad Research Center Carlsbad, California CARLSBAD RESEARCH CENTER MONUMENT SIGNS 04/25/ 05 0 E 51 111) H21 West Levm Street San Diego. California 92103 f3J=SiaS«.I837 w.%v.stuaitwhited»r3n.cain ' G£:ri&ra{ Requirements Tha Contractor shall be responsible for tlie quality of all materials and u'Orkmanship required for the execution of this contract including the nnaterials and workmanship of any firms or individuals who acc as his subcontractors. Contractor shall ba responsible for providing Stuan White Design, further referred to as Designei; with as-bullt drawings and specifications if fabrication methods are different from v^hat appears in these drawings.The Contractor shall verify and be responsible for all dimensions and conditions shown by these dravi,'ings.Shop di-avilngs for any details not appearing in these plans must be submitted to the Designer for approval before proceeding with febricatlon.The Designer shall be notified of any discrepancies in the drawings, in field dimensions or conditions and/or changes required in construction details. Location of Signs Tl'.e locations shown on the plan drawings are generally accurate, but may be open 'o some Interpretation. If any questions arise regarding sign locatior\,the fabricator Is to arrange a ineeting with the Designer at the site for final location of sign elements. Scafjs Provide all labor and materials necessary Co fabricacei paint and install all signs shovi/n on the Designer's drawings and/or Graphics Schedule attached. Permits Contractor shall obtain and pay for all permits required for execution ofthe work. This Includes building and structural permits necessary to buitd monument and self standing signs. Labeling Loca tion on the sign of all required labeling {i.a, city sign permit) shall be approved by Designer prior to application to any Item. Project logo Copy shown on the drawings shall be used as a general layout guide to determine proportional she of logo, and location to be pinned to aluminum sign cabinet Logo to be provided In a digital forma r by designer for fabrication use. No substitutions will be accepted. Concrete Footing Si Forms Contractor to provide structural engineering for all support and footings as required. Footing to accept aluminum cabinet flush to footing edge. Footing to be 'iibove level soil line. Footing and forms must be built to accept granite tile with 1 fiastic, and not to exceed specified dimensions of sign as described in drawings. Any engineering details which affect appearance must be approved by Designer. 'i/Vatsr Jet Cut-Out Aluminum Letters Computer cut system to be used, aluminum faces and returns to be free of any . blemishes, obtaining a smooth finish. Granite Tile 12"x 12" "Elba Brown*granite tile to be used as specified by designer.Granite shinned to masonry form with exterior grade mastic and grout.Cornertjolnts on top and returns (Not Faces) of uprights.Only cut tiles to be placed on bottom of form to extend to soil line at 4"height mark. Ail concrete sur^ces (except under aluminum cabinet) to be skinned with full I2"x 12" tiles. All Joints.between cabinet, aluminum shelf, and tiles will be filled with commercial gracie silicone. Shop Drawings Details of exposed edges, joints between materials snd details which effect the appearance shall be provided to Designer for approval before fabrication. Indicate the gauge or dimension ofall components on the shop drawings. Sign Requirements - JVlaterials As a general requirement, the Contractor shall submit samples of all materials to be used prior to fabrication, induding actual colors and finishes specified Adhesives All adhesives shall be used in accordance with recommendations made by the manufacturer of the material specified to be laminated or adhered. No adhesives that will fad^ discolor or delaminate as a result of proximity to sunlight or heat therefrom shall be used and shall not change the color of or deteriorate the materials to which they are to be appl!ed.The adhesives shall be of a non-staining, non-yellowing quality and ali visible Joints shall be free from air bubbles and other defects. Sign Fabrication and installation General: All work under this contract shall be performed by skilled craftsmen under the supervision of trained foremea experienced in the trade or craft required to accomplish the work and produce a product of high quality.The Contraaor shall guarantee all materials and workmanship for one year after the date of acceptance ofthe work by the Designer and the Owners. Graphics and/or sign colors shall be as shown on the drawings. Sign finish for exterior signs shall be Mathews Paint, satin finish, submit sample. Sign finish shall be smooth, free of scratches, gouges, air bubbles, bulging, foreign matter and other imperfections. All exposed corners and edges shall be finished flush and smooth. If silicone adhesive is used for Installation of sign items shall be General Electric Contraaor's Silicone Sealant SCS 100 (dear), or equal.Studs on the back of sign panels to be blind stud welded with no warping or defacement of any kind appearing on the face of panel or using a threaded rod into threaded hole on back side of aluminum. Any alternate method of attachment must be approved by the Designer prior to fabrication. Seams and joints: Welded joints shall be ground, filled and finished flush and smooth wjth adjacent work. Such seams and spot-welded joints shall not be visible on exterior of signs after final finish has been applied. No gaps, light leaks, waves or oil canning will be permitted in tha work. Unless noted otherwise,all exposed joints between sign components shall be butted flush, or at 90°. Fasteners for Aluminum; Most fasteners are called out on the documents. Any substitutions or alterations must be submitted and approved by the designer. Connection of Sign fo Footing: Inner support pipe or rod reinfordng member shall be painted with rustoleum (or equal) rust resistant paint and sec directly into concrete. Cleaning and Protection: At completion of installation, clean all surfaces in accordance with finish manufacturer's instruction. Protect units from damage until acceptance by the Owner.Repair or replace damaged units as directed by the Designer. Apply final coatof liquid automotive wax if required.This should be repeated yearly as a maintenance item (by the Ownersj.The Contractor shall provide to the client written instructions and schedule for the proper maintenance ofall items, in a bound manual form, including guarantee, warranties and complete maintenance instructions, four copies required. Contractor shall provide "As-Built Drawings' to the Owner at the completion of Installation. ; Painting and Finishing General: All paint and finish materials induding primers, shall ba the finest quality obtainable. Surface Preparation: Preparation and primers shall be as recommended by the manufaaurer ofthe finish materials. All metal surfaces, including areas within signs shall be properly primed and painted fill paint materials shall be applied according to the manufacturer's recommendations. Paint Colors and Finish SampIesiSubmii 6"x 8"color and finish samples in duplicate to the Designer for approval prior to painting. Paint finishes shall be satin finish except as noted otherwise on the drawings. Except as spedfied above, paint for wood or metal supports and other surfaces shall be as manufactured by Matthews Paint Company, and as recommended for che specific surface by the manufacturer.Method of application used shall be as required to achieve a final coat'which is uniform in color, finish, texture, and coverage. All ideas, designs, arrangements, and plans indicated or represented by ait drawings in this set are owned by and are property of Stuart White Design, and were created and developed for use on and in connection with the specific project. None of such ideas, designs, arrangements or plans shall be used ar disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Stuart White Design. Written dimensions on these drawings sball have precedence over scaled coiiditions on the Job and Stuan White Deslgt) must be notified of any variations ofthe dimensions and conditions shown by these drawings.Shop details must be submitted to Stuan White Design for approval prior to fabrication. NOTE: These drawings are intended to convey design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator to Insure quality fit and finish for all components KII Wast Lewis Streiii 619542.1815 Job Hatne: -SlgnHUe: Sign Quantity: Seals: Approved: Qtals Owincfiinjss Page: Ss.T Diego. CalilorniiS ficdlSJ'13.ia37 Carlsbad Beseech Center Monument Sign Guidelines 4 (M/25/05 N/A Inilials: _ - ... .. . 52103 • mw.stuamvhitedeslgnrom Daie: _ 1 Daie: _ ARLSBAD RESEARCH CENTER PROJECTIogo Project logo to be provided in digital format by designer, no other solutions will be accepted K21 WeslLsi-.is Sirest dl9j.)2.iai5 Job Mame: .SlfliiTiUe: SIsaQuanaty: Date: Scats: Ap^rave'il: [3x13 OwUiOwmgu Page: S;,n Ditgo. Calibrnia Fas £19.542.183/ Carisbad Research Center Project Monument Sign Logo 4 04/25 / 05 N/A Inilials:. ... .... 921Q3 w.'wjtuamvhkedesigMom ^Slx4n Y'liilc Dciijii JIW4 Line. . ~—-~ . 12'-fl- -1 vr IPli 12- SIDEVIBM •COHCRnEfOQTlliaTOBE ciiemmm OY FAEAiHroR 3--0- V « .friers--" 12" B" 11'-6- PLAUVIEW \rx\2- -aeA BROtJir GiuNrrE TILE SKIIIIIEO TO LIASONRY ranu fASBlOnED SLUM. MBINET PAWTED MArHEVllS IT. CHAUPAlfiN' (MP 21105 H 6021) THICK VIKim JET CtrT.OUTALUM. LETTiRS PAINrED MATHEWS DK BRQtIZE (MP 4l3t3) 1- THICK ALUUIHUU SHELF PAINTED UATHEK'S aHUSHED ALUU. (UP 41-342) — s:*-V,'' aB/ATION ir CONCRETE rOOTIhIG TQ BE EHSINEEAED BV FABaiCATDfl EXISTIUS LEVa GRADE 3 y. 77 7: 3 I! )3 •I / L TILE TO GRADE EXISTING LEVEL GRADE IIII WeslLeivis Suan 619JJ2.1S1S Jab Mama: SlgaHUe: Sign Quaniity: Data: Scate: ApptDUed: (3 As IS (3WiuiCla.ige] Page: Sar. QtegaCAlIIatnia Fjcsiaj-iz.iaj? Carlsbad Hesearch Center Mocument Sign 4 IM/25/D5 1/2'= V-0-Inilials: . . . . . 3 92103 v.-.v.-/.siupmvIiiteda5ignxoni Data: _ .. -3 I \ \ \ / \ 4iS^kmmm3\- Z ® ALUM. CABINCT SECriQN SIQE VIEW SCALE; 3/16-= r fABRlCATEO ALUMIMUU CABINET . PAINTED MATHEWS IT. CHAMPAIGN" (tiP 21105 fl 6021) 1 l/2"Ta WATERJET CUT-OUT AI.Ua LEHERS PAIHTEO MATHEWS DK BBONZE {MP 41313] Pll^llEO & ADHERED WITH SlUCOME RUSH TO ALUM. CABINET 3.-8- STAINLESS STEEl THREADED STUD TAPPED INTO AUUlt LEITER 1- THICK X 12- DEEP X1 r- r LENGTH ALUMINUM SHELF, WITH INSIDE SQUAHE TUBE FBAMEWORK FOR SUPPORT PAIOTEDIMTHEWS BRUSHED ALUM. (MP 41-342) ELEVATION SCALE: 1/2" = r-0' 71/2" 12' 10--3-MAX LOGO WIDTH ?1/2' ® • CONCRETE FOOTING TD BE ENGINEERED BY FABRICATOB rTHICK)(12-DEEPX1V-6- ALUMINUM SllEtf PAINTED MATHEWS BRUSHED ALUM. • TILE TO GRADE 1 •12! Waa Lewis Sueai 6I9.S41IBIS Jotl Hame: SlgnTlUe: Sign Quaniity: Oats: Scale: AptltQUed: QASIS nwiUiClanges Page: Szri Jliega. CaliTornta Far619342.I337 Carlsbad Research Center Monur/ieni Sign 4 - Grades and Soil Unes 04/25/05 Noted Initials: _. 4 92103 VAvwiiuatwIiiiedesignioni Logo Placement Vary BetVijeen Signs Dale: 4 '.Vliili; Oaign Dale: 4 I.. SITEPLAH SC/iLE:r=20'-0- 15'-D- ELEVATIOW SCALE: 3/a" = V-0- ki ":-••/1 I 10- SETBACK ••:••:•:••-- jiiK -:• -:• P^-73f37r'^3P-''PP • ' "- . CONCRETE FOOTING TO BE ENGINEERED BYFABRICATOH ' FINISHED GRADE EXISTING SOIL UME TIU TD GRADE Jotl Name: Sign Tille: Date: Scale: Approved; QASU •wwctai^u Page 1421 V-toi Leras Sirc-a 6!9J42.iai5 Sign Tille: Approved; QASU •wwctai^u SiinOiisgaOililoi/iis fax;619i41ia3? Carlsbad Research Center MOt^lUMENTSIGM 04 / 25 / 05 WOTED InlLals: 6 92103 wvAv.t[uam-/littedsrslgniX«n AT FAHADAY AVE. & EL CAMINO REAL Data: 6 <(> Smart Wnilt Uin-i^n 3031 Data: