Loading...
HomeMy WebLinkAboutPS 12-35; Hoehn Buick GMC Cadillac; Sign Permits/Programs (PS)r r------------------------------------------------------------------------, " ~ ,;~!' ..... '<' ~ .. ··~ CITY OF CARLSBAD REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNINGf.PP~ICAljl9!~gs I a--3'5 REC'D BY ~(~ .............. """"--"."""·~~::..>oo<Z~-----­ DATE .5~-'i-· I',). SIGN FEE -'"'-1'--1!5--_,t __________ _ SIGN PROGRAM FEE--------- RECEIPT NO.------------ All P.lans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS· OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE.· The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: 8~J;t tik ~ C Uvl!Lk ADDRESS OF PROJECT: sq34-Pl0eff-7Ji[ /Vo-lk (A,t})bcyd} CA: 9UJOB ASSESSOR PARCEL NUMBER: ~I I -DhO-09-. ··RELATED PLANNING CASE NUMBER(S): ----------,-------- TYPE OF DEVELOPMENT: Residential (d) Commercial (e) ) Office/Industrial (f) SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Hotel/Motel Service Station Prof. Care (g) Theater (h) · Gov't/Church (i) Public Park U> Produce Stand (k) Nursey (I) P-UlOS Zone Yes~ NoD Specific Plan Number ____ _ VILLAGE REDEVELOPMENT AREA Yes0 Noll§l Requires VR Approval P-11 Page 1 of4 Revised 07/10 SIGN ORDINANCE: Yesgj NoD COASTAL ZONE: YesD No~ EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole ;/-7 7 f21 2-1 ~' Monument Wall 1--trill lb' Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes~ NoD Date ------- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT ··~~t* _j_ IZ13:i'J 32/ 2(:]" Monument** Wall 1 1-5 !A· 1 i, I -Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of4 Revised 07/10 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I 1 I PIL • Sight Distance Requirement • I • • I Show building Is • • • • I • • I : : I • • Show setbacks from all curbs ,_ ---l --- I • • I • I I • • I • I Show all property Jines I • • PIL I • . • I • I • I I • • curb line • • • • • • • ------------- Sight Visibility I Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) __ ...::;.I_;;_JAJ _____ sq. ft. ·34:0 sq. ft. !01_ -----'="-----sq. ft. CJ. I l sq. ft. __ ---:....1..::::...5"_3~---sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN __ ....,lfo~S.L.-----sq. ft: P-11 Page 3 of4 Revised 07/~0 PROPERTY OWNER APPLICANT NAME (PRINT r.;;:JJ NAME (PRINT OR TYPE) 0~ . ' {~ ~1 MAILING ADDRESS MAILING ADDRESS J ~55b Fa1'Yri--/ fl-· CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE -Wt~ 05/r~ . eft-'/J9J/ if If ~J:.7J~J53~ I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION IS OF THE LEGAL OWNER AND THAT ALL THE TRUE AND CORRECT TO THE BEST OF MY ABOVE INFORMATION IC' ..,) TRUE AND KNOWLEDGE. CORRECT TO THE BEST OF MY KNOWLEDGE. s~f~J/8 .5"}q /Jn... SIGNATURE DATE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •!• In right-of-way •!• In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: CJrA~.{) , ~~ Date:5-ol ( -J')_ P-11 Page 4 of4 Revised 07/10 City of Carlsbad Faraday Center Faraday Cashiet·ing 001 1213001-1 05/09/2012 32 Wed, May 09, 2012 01:15PM Receipt Ref Nbr: R1213001-1/0020 PERMITS -PERMITS Tran Ref Nbr: 121300101 0020 0020 Tt·ans/Rcpt#: R0089536 SET #: PS120035 Amount: Item Subtotal : Item Tota'l: 1 @I $57.00 $57.00 $57.00 ITEM(S) TOTAL: $57.00 Check (Chk# 050493) $57.00 Total Received: $57.00 Have a nice day! **************CUSTOt~ER COPY************* City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 11111111111111 ~11111111111 IIIII 11111111111111111111 1111111111111 Applicant: ATTEBERRY STEVE Description Amount PS120035 57.00 5334 PASEO DEL NORTE CBAD Receipt Number: R0089536 Transaction ID: R0089536 Transaction Date: 05/09/2012 Pay Type Method Description Amount Payment Check 57.00 Transaction Amount: 57.00 ACKNOWLEDGMENT State of California County of San Diego Title ofDocument Coo.se(};(;. .$ flgreetneJCt D . .r;. lA.nJ. Ow~ On Jan u.a,;!J 3 1, ,;;_ 6 / ;;;;._ . before me, Dianne Linda Walker, Notary Public, personally appeared Sarah Rorick-Orlando, who proved to me on the basis of satisfactory evidence to be the person whose name is subscribed to the within instrument and acknowledged to me that she executed the same in her authorized capacity, and that by her signature on the instrument the person, or the entity upon behalf of which the person acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WI1NESS my hand and official seal. Signature of Notary • DIANNE LINDA WALKER Commission # 1795456 j Notary Public • California 1 J san Diego County ~ ••••• ·*~-Ot~f\2 .~ CONSENT AND AGREEMENT OF lAND OWNER. (lfDealcnldp docs DOt own tile lalld) LeueNo:32623~ Daller ld: '1996 DiYIJ))r No: Buicit/116120 Pap2of9 The unc:lemigned. who is the owner of the land described in the attached Dealership Identification lLease Ap:cment between GM-DI LBASING CORPORATION, as Lessor, and HOEHN BUICK GMC CADR.LAC, as Lessee, hereby consents to the installatiOD, maintenance, operation and removal of the sign(s) to be iDstalled pursuant to saicl Lease. The undenigned tbrther acknowledges tbat the afcnsaid sign( a) are the property of GM·DI LEASING CORPORATION and agrees that, in the event of termination or expiration of said Lease or any extalsion or renewal thereof; GM-DI LEASING CORPORATION may at any time thereafter enter upon and remove from the premises all of the sip(s) iDBtalled pursuant to said I.Atase. It is 1brther acknowledged by the UDclersigned that Le&sor's only obligations upon any such removal of sign(s) shall be those described in the attachecll Lease and GeDera1 Provisions. .I- by ___ _ Notary Public, ________ _ sv ~:!Jt01~ ~c · ' ~~) ·~~~~~ v NAME: So..y~h 'l<ov1 vk.-Q r-/o,n.d.a (Pieue Priator'IP) ADDRESS: __lQJS C.hes±o u.t Aye, . ~+e. fa.clolaa-4. • c.4.. q;tp;;:t? Project· Get1eral Motors (b ROSS BRYAN ASSOCIATES, INC. Model P-137-26-90 CONSULTNG ENGINEERS By KTF NASHVILLE, TN. I~ b .I U) b1 =--~ r .......-D U) I I ' ' I I ' ' r I I IV ' I ' g I I ' ' u p ~ -I ' ~ I e I ' ' I I ~ <=~ !::::, <='===>. l J Sheet No. 1 of Job No. 12 4630 Date 5/2/12 EXPIRES JUN 3 0 2012 6 c Ol D ....., ill ill .c UJ L ill > 0 u lJJ c 0 ....... ....., m :::::1 u m ~============================================================================~u Project Model By General Motors Retrofit P-137-26-90 KTF ..__ CONSULTING ENGINEERS Job No. f1 ROSS BRYAN ASSOCIATES, INC. Sheet No. .::J NASHVILLE, TN Date CODES: 2010 California Building Code 2009 International Building Code-Wind Loads per provisions of ASCE 7-05 AISC Steel Construction Manual, 13th Edition ACI 318-08, Building Code Requirements for Structural Concrete SIGN DIMENSIONS: Upper Sign Upper Sign Lower Sign Lower Sign Length, B Depth, s Length, b1 Depth, s1 11.27 ft. 11.27 ft. 0 ft. 0 ft. 2 12 463,0 5/1/1:2 Overall Column Column Column Unbraced Column Height, h Height, c Spacing, e Cover, g Length, Lb 26.5 ft. 14.73 ft. 4.33 ft. 0.875 ft. 12.84~ ft. MAIN COLUMN SECTION PROPERTIES: Section: W10X49 F -y -36 ksi E= 29000 ksi COMPACT FLANGES of A= 14.4 • 2 ln. T= 7.5 in. r = y 2.54 in. Cover Plates: Not Applicable d= 10 t = w 0.34 bf = 10 tf = 0.56 DEAD LOADS: Sign Weight= Column Weight= WIND LOADS: in. in. in. in. 12 49 I = X s = X r = X z = X 272 54.6 4.35 60.4 psf lb/ft qh = o 00256 * k * k * k * v2 * 1 · z zt d k = z 0.96 kzt = 1.0 kd = 0.85 V= 90 I= 0.87 qh = 14.67 lb/ft2 P = qh * G * ct G = 0.85 B/s = 1.00 s/h = 0.43 Ct = 1.77 . 4 ln. rts = . 3 ln. h = 0 in. J= . 3 ln. c = w 2.84 9.44 1.39 2070 Concrete= Soil= in. in. . 4 ln. . 6 ln. b= t= sx(eff) = Zx(eff) = 150 pcf 90 pcf Velocity Pressure, ASCE 7-05, Section 6.5.10 0.00 in. 0.00 in. 54.60 . 3 In 60.40 • 3 In Velocity Pressure Exposure Coefficient, ASCE 7-05, Table 6-3 Topographic Factor, ASCE 7-05, Section 6.5.7.2 Wind Directionality Factor, ASCE 7-05, Table 6-4 Basic Wind Speed, mph, ASCE 7-05, Figure 6-1 Importance Factor, ASCE 7-05, Table 6-1 Design Wind Loads, ASCE 7-05, Section 6.5.14 Gust Effect Factor, ASCE 7-05, Section 6.5.8 Length of Sign/Depth of Sign Depth of Sign/Overall Height Force Coefficient, ASCE 7-05, Figure 6-20 6 p = 22.06 lb/ft2 CASE A: resultant acts normal to sign face through the geometric center CASE B: resultant acts normal to sign face at a distance from the geometric center toward the windward edge equal to 0.2*Sign Length CASE C: not applicable Projec.t General Motors Retrofit ('"b ROSS BRYAN ASSOCIATES, INC. Sheet No. 3 of Model P-137-26-90 CONSULTING ENGINEERS Job No. 12 4Ei30 By KTF NASHVILLE, TN Date 5/1/12 CHECK COLUMN: W10X49 F = y 36 ksi COMPACT FLANGES LRFD Load Combinations: 1.20 + 1.6W ASCE 7-05, Section 2.3 Resistance Factor for Flexure: <Db= 0.9 AISC Specification F1 Service Wind Loads: Moment Arms: Upper Sign, Pw= 2.80 kips 20.87 ft. Lower Sign, Pw = 0.00 kips 14.73 ft. Columns, p = w 0.57 kips 7.37 ft. Total Service Moment at Base: M= 62.65 k-ft Column Design is Controlled by Wind Load CASE B: 100% of sign load is transferred to column due to offset. Factored Moment at base of one column: Mu = 96.89 k-ft Yielding: Mn = Mp = Fy * Zx M = n 181.20 k-ft Lateral-Torsional Buckling: Lb = 154.08 in. L = p 126.88 in. Lr = 502.03 in. Lp < Lb::;; Lr Mn = Cb*[Mp-(Mp-0.7*Fy*Sx)*((Lb-Lp)/(Lr-Lp))]::;; Mp <Db *Mn = 163.08 k-ft <Db * Mn = 163.08 k-ft > > Mu = 85.37 k-ft Mu = 96.89 k-ft AISC Specification F2-1 Unbraced Column Length AISC Specification F2-5 AISC Specification F2-6 AISC Specification F2-2 At the Bottom Brace Point At the Base Plate 6 (j ROSS BRYAN ASSOCIATES, INC. Sheet No. il_ CONSULTING ENGINEERS Job No. EJ NASHVILLE, TN Date Projec~ . General Motors Retrofit Model P-137-26-90 By KTF 4 12 46:10 S/1/1.2 of CHECK WELD OF COLUMN TO BASE PLATE: Resistance Factor for Welds: <D= 0.75 Fillet weld size = S/16 Sweld = 41.65 • 3 In Wind Load and Moment: M = u 96.89 k-ft Transverse Load In Weld = (MufSweld)*(effective throat)= Longitudinal Load In Weld= Pu/(2* Lweld) = Total Load In Weld = Transverse + (1+0.5*sin1.5<0) Longitudinal = (1+0.5*sin1.5<D) AISC Specification J2 Pwu = 4.94 kips 6.17 kips/in 0.33 kips/in 4.44 kips/in AISC Specification J2-5 Weld Design Strength, <I>Rn = 0.7S*(0.6*Fexx)*(Effective Throat) AISC Specification J2 O.K., <DRn = 6.96 kips/in > 4.44 kips/in CHECK BASE PLATE AND ANCHOR BOLTS: LRFD Load Combinations: 1.2D + 1.6W Resistance Factors: <Db= 0.9 <De= 0.65 <Danchor = 0.75 Base Plate Size: Length, N = 18 in. Anchor Rods: No. of Bolts = 6 Size of Bolts = 1 1/4 in. ASTM Designation = AS72 Gr. SO Tensile Stress, Fu = 65 ksi Wind Load Moment: Mu = 96.89 k-ft ASCE 7-05, Section 2.3 AISC Specification F1 ACI 318-08 ACI318-08 Width, B = 17 in. Anchor Spacing, B-dir. = Anchor Spacing, N-dir. = Edge Distance = Embedment= Dead Load at Base: F = y 6 14 2 36 1.78 36 in. in. in. in. kips Equivalent Eccentricity e = MufP du = 652.97 in. AISC Steel Design Guide 1 (3.3.6) Critical Eccentricity: ecrit = (N/2)-(Puf(2*qmax)) ksi AISC Steel Design Guide 1 (3.3.7) ACI318-08 ksi qmax = fp(max)*B = ecrit = 8.98 46.96 kips/in in. < e = 652.97 in. AISC Steel Deisgn Guide 1 (3.3.4) DESIGN PLATE FOR LARGE MOMENT Bearing length: Y= 1.65 in. AISC Steel Design Guide 1 (3.4.4) Plate Thickness: tp(req) = 13/16 in. Total Tension in Anchors, T u = 75.66 kips AISC Steel Design Guide 1 (3.4.2) Tu per anchor= 25.22 kips <Danchor*Rn= <D*0.75*Fu *Ats = 44.87 kips > 25.22 kips Concrete Breakout: <D*Ncbg = 107.65 kips > Tu = 75.66 kips USE 18 in. x 17 in. x 13/16 in. plate with 6-11/4 in. diameter AS72 Gr. SO bolts. 6 Pr.oject General Motors Retrofit fl. ROSS BRYAN ASSOCIATES, INC. Sheet No. 5 of 6 . Model P-137-26-90 CONSULTING ENGINEERS Job No. 12 4630 By KTF NASHVILLE, TN Date 5/1/12 CHE~K FOU~DATIONS: LRFD Load Combinations: 1.2D + 1.6W ASCE 7-05, Section 2.3 Resistance Factors: <Dplain = 0.6 ACI318-08 <D = v 0.75 ACI318-08 <Db= 0.9 ACI318-08 f' = c 2500 psi Pedestal Width = 7.54 ft Pa = 100 psf/ft Pedestal Length = 3.375 ft qa = 1500 psf Overburden = 0.25 ft Total Service Wind Load: p = w 3.37 kips Total Service Moment at Base: M= 62.65 k-ft Rectangular Spread Foundation: Length= 10 ft. Width= 8.33 ft. Depth= 3.2S ft. Dead Load, P d = 45.45 kips Overturning Moment, M0 = 76.13 k-ft Resistive Moment, Mr = 227.25 k-ft MJM0 = 2.98 > 1.5 O.K. Eccentricity, e = M/P d = 1.38 ft. kern, k = 1.67 ft. e<k Bearing Pressure, qmax = 996.89 psf < qa = 1500 psf O.K. Moment in Footing Mu = 115.96 k-ft Use 7 No. 7 Bars Top and Bottom-Length. Use 9 No. 7 Bars Top and bottom-Width. Moment Capacity, <DMn = 662.35 k-ft > M = u 115.96 k-ft O.K. Check Shear, Vu = 0.55 kips/ft Shear Capacity, <D*Vu = 32.01 kips/ft > Vu = 0.55 kips/ft O.K. Block Foundation: Length= 7.25 ft. Width= 7.25 ft. Depth= 7.25 ft. Dead Load, P d = 61.31 kips Overturning Moment, M0 = 89.62 k-ft Resistive Moment, Mr = 230.40 k-ft MJM0 = 2.57 > 1.5 O.K. Eccentricity, e = M/P d = 1.02 ft. kern, k = 1.21 ft. e<k Bearing Pressure, qmax = 1500.00 psf < qa = 1500 psf O.K. Moment in Footing Mu = 80.81 k-ft No Reinforcing Required -Use Minimum Steel Use 6 No. 7 Bars Top and Bottom-Each Way. Moment Capacity, <DMn = 1347.19 k-ft > M = u 80.81 k-ft O.K. *Shear is checked at a distance of d from the face of the pedestal; however, d is beyond the edge of the block footing, so the shear check is not applicable. Project General Motors Retrofit f"b ROSS BRYAN ASSOCIATES, INC. ~ . ~ ~ Model P-137-26-90 CONSULTING ENGINEERS By i<TF NASHVILLE, TN CHECK FOUNDATIQNS: LRFD Load Combinations: 1.2D + 1.6W Resistance Factors: c:t>= c:t>= c:t>= f' = c 2500 psi p = a 100 psf/ft qa = 1500 psf Total Wind Load: Total Service Moment at base: Vertical Slab Foundation: Length= 2.5 M(top of slab)= Height to P w• h = Required Depth, d = Moment in Footing, Mu = Use 7 No. Use 7 No. Moment Capacity, Cl>Mn = Circular Caisson Foundation: No. of Caissons= M(top of caisson) = Height to P w, h = Required Depth, d = 2 Moment in Footing, Mu = Use 9 No. 0.6 0.75 0.9 Pedestal Width = 7.54 Pedestal Length= 3.375 Overburden = 0.25 Pw = 3.37 kips M= 62.65 k-ft ft. Width = 8.33 ft. 65.18 k-ft 19.34 ft. 6.26 ft. 104.29 k-ft 6 Veritcal Bars on Each Face 6 Horizontal Bars on Each Face 364.44 k-ft > M = u Diameter= 3 ft. 65.18 k-ft 19.34 ft. 10.67 ft. 104.29 k-ft 7 Vertical Bars Use No. 3 Ties at 14 inches o.c max. Sheet No. 6 of Job No. 12 4630 Date 5/1/12 ASCE 7-05, Section 2.3 ACI318-08 ACI318-08 ACI318-08 ft ft ft Depth= 9.5 ft. IBC 2009, Section 1805.7.2.1 104.29 k-ft O.K. Depth= 11 ft. IBC 2009, Section 1805.7.2.1 Moment Capacity, Cl>Mn = 316.29 k-ft > Mu = 104.29 k-ft 6 m ~ tn ::! z Ci) aJ c: r c z Ci) 0 z tn ..... m tn g r m ., :::0 0 ., 0 tn m c z m =e ., -< r 0 z tn Ci) z 0 ::r:< mm N -::::0 0'-G>)> I ::r:r 0 r =--=~- _. ·-----. .... ....... --· SITE PLAN ' • f 'Ill .. ., c.n w w ~ ~ tn m 0 c m r- z 0 :::tJ .... m 0 )> :::tJ r-tn m )> c 0 )> -..() N 0 0 co 01 w 0 \--- ~--· ! r·:--·:- ~----~--~~----~-- =-=~-...... ·--............ ....... --· SITE PLAN \ ' \ \ \ \ \ ' \ \ ' \ ' \ \ \ \ \ \ \ \ ' \ \ \ \ \ \ \ \ ' \ \ ' .. .) , "'"r"'hlooolr-o-,-...... -· ot'll • 111 ' Buick GMC Cadillac Sign Family !:! ~ Availle SlMdard 4~T l ,....-----15'.() 112" -----, P245 ~PATTISON ~ SIGNGROUP A Division of Jim P•tti•on 'ndvllri., Ltd. I ~ ~ L Availle S1andard Heigb 36',31~ ,.---11'-3 1/4'------., .-J!L!~LY-1'·21/2' -,......, ~.-.1 I . · · · I· 1'·91/'2' -/a~-e.e; 2'·1112' l:ltllAI:IIi.Jli11ll D § Ne.\4) Q~o~ed 555 Ellesmere Road Tel (416) 759·1111 Fax(416)759-4965 Toronto, Ontario, Canada M1 R 4E8 Avlille Sllndwd ~ www.pattisonsign.com Toll Free 1·800.268·6536 SIGN P245 P137 P92 564 P38 ·536 516 MOLDED GRAPHICS 8' .. 1/4" r-~ 8' .. 1/4' r-~ ~~EZLEL£ ! ~ IL I 21.()' P92 ® e~~h~ The artistic works depicted herein are copyright and are the exclusive property of Pattison Sign Group and as such cannot be reproduced In whole or in part without prior written consent. NOTE: 3 & 4 LINE USE CADILLAC SCRIPT #2 BUICK GMC:: - 1 '-7 1/2" 2'-4 1/4" 1 '-2 1 /2" 1 '-9 1/2" 11 1 /4" 1 '-4 1/2" 11 1/4" 1 '-4 1/2" 8" 1 '-0" 8" 1'-0" 4 7/8" 7 1/4" RED INDICATES FLAT GRAPHICS ~ 2 '-1 0 1 /4" 2'-1 1/2" 1 '-7 3/4" 1'-7 3/4" 1'-2 1/4" 1 '-2 1/4" I 8 3/4" ·I I ALL FLAT GRAPHICS e· 16'~9/16'1 P38 ® 1'.()' 1'·21/4' 21'~· I ,. S36 rf -47/8' ::f . L 17'.()' S16 Pattison Sign Group signs illuminated by Fluorescent, Neon and/or HID Lamps contain Mercury (HG). Dispose of these lamps according to Local, State, Provincial or Federal Laws. Vantage II: Date: 2-NOV-Q9 Design II: 09-1469 Scale: 1/8"=1'-Q" Sales: A. Hollyoak Designer: J. Foster I Rev.#: R4 Date: 11-MAY-10 D Vector Artwork Required D High Resolution Image Required D Final Colours Required [I) Conceptual artwork only f Electrical Requirements O nov D 347V 0 0ther __ _ o-volt~gl'! ... ~s tob~ ;;;~&.~ pr'iorto customer l'lpprol'!ll. Customer Approval Date