Loading...
HomeMy WebLinkAboutPS 12-53; SKLZ; Sign Permits/Programs (PS)CARLSBAD REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING AW,LICAJ.IPN # PS J J -53 REC'D BY :E£rtt. (TM&J,· DATE -~:e_~Dlc SIGN FEE (i 5'] SIGN PROGRAM FEE_-________ _ RECEIPT NO.------------ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: S1£.L--::c ~Q.L.c.o~ ADDRESS OF PROJECT: ~ CZ)l (~a.Ao fY:1 ;::+-./dfJL'>€ ASSESSOR PARCEL NUMBER: ~ I;).. - / '2c' -~6 ··-o(} RELATED PLANNING CASE NUMBER(S): ----------------- TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel ~ommercial (e) Service Station (c) Office/Industrial (f) Prof. Care (g) Theater (h) Gov't/Church (i) Public Park U) Produce Stand (k) Nursery (I) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes!%~ NoD Specific Plan Number SP I Jc) VILLAGE REVIEW AREA SOUTH CARLSBAD COASTAL REVIEW AREA P-11 Page 1 of 4 YesD YesD N~ No~ Revised 05/12 SIGN ORDINANCE: Y~ NoD COASTAL ZONE: Yes0 ~ EXISTING SIGNS· "' ~p -o2_A ~ • TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument , ' Wall 2--'2. S <; • c;. ( d'l;1\ JAAi\~ )) ~\~Col\ Suspended / Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes0 N~ Date _______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** - Wall 3 '{__ l~.s.F.(e-A-. -s<o q Z.tf" , Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into 1the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Revised 05/12 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. P!L Shm•ir building Is Sight Distance Requirement : I • • • • • • • • ~ 4 • • • ' ____ J __ ~hmv setbacks from all curbs Shm'or all property lines curb line P!L • • • • • • • • I • • • ' . ' . • • • • • • • • --/~ ... - ~ Sight Visibility 21.41.080 Sign design standards Street N ame(s) I I (i) North Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) "2.."'1..t Oe>o ~sr-. sq. ft. sq. ft. t-J.Afh/'tp~~·Y= sq. ft. -----------sq. ft. -------·---sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN __________ sq. ft. P-11 Page 3 of 4 Revised 05/12 • From:582 9023188 08/23/2008 08:32 tt902 P.002/002 05/20/2013 03:02 FAX ~0002/0002 PROPERTY OWNER APPLICANT MAILING ADDRESS ~o.~ '"2-'3o~~ '. NAME (PRINT OR TYPE) ~ S\:C..t-"0 MAILING ADDRESS 'CD$( ~ ;.J~ I CERTIFY THAT JAM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. lnJ11JrL ~ SIGNATU PlANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria; if applicable. 4. Location: •!• In right-of-way •!• In visibility triangle at comer 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route~ Data Entry • : /.. APPROVED: Planner: ~ ·····~/u"L'D-Date: 6(@-'~/'Joi'L P-11 Page4of4 Revised 05/12 0 > Carlsbad Research Center 20 June 2012 Ms. Cindy Jacob BIODECLLC P.O. Box 230931 Encinitas, California 92023 Re: Lot 50-SKLZ Sign Review Dear Ms. Jacob: Architectural Review Committee The Architectural Review Committee (ARC) of the Carlsbad Research Center (CRC) has reviewed. the sign plans submitted by Clear sign and Design, Inc. on behalf of SKLZ, located at 2081 Faraday Avenue on Lot 50 in the CRC. The proposed plans, for two wall signs and address identification, are fully consistent with the CRC Design Guidelines and are therefore considered APPROVED. You may proceed with sign installation after you remove tile existing walls signs on the building and af1ter you receive a City of Carlsbad Sign Permit. Once you have the city permit, please provide a copy to: Ms. Andrea Ferris Meissner Jacquet 5330 Carroll Canyon Road, Suite 200 San Diego, Califomia 92121 Do not hesita~e to contact me if you have any questions or t·equire additional information. Sincerely, -/~-/~"~ Seth Schulberg ARC Staff cc: ARC, A. Ferris and N. Foussianes 1530 Faraday Avenue Suite 100 G Carlsbad, CA 92008 & (760) 931-0780 e (760) 931-5744 Fax CARLSBAD RESEARCH CENTER-ARCHITECTURAL REVIEW COMMITTEE Sign Evaluation Matrix for: SKLZ (20 June 2012) I Applicant Address: 2081 Faraday Avenue Building Area: 158,778 ff I Lot No: 50 Sign Criteria CRC Design Guidelines Proposed Dimensions Number per lot Building area < 35,000 ft"' = 1 wall or 1 monument Building area > 60,000 ft2 = 3 wall or 1 monument 2Wall Number per elevation Monument Sign: 1 per lot. Wall Sign: Building area <35,000 tf = 1 Building area > 60,000 ft2 = 2 1 Sign dimensions Not specified 2ft.X9ft. Area 50.0 ft" maximum (monument or wall) 18 n~ Sign Height Monument sign: > 3 feet, sign must observe building setback of 30 ft. ::; 3 feet, at least 20 feet from curb Wall Sign: Below eave line Below eaves Sign Depth Monument signs must be at least 8 inches in depth N/A No standard for wall signs Size of lettering/logo Monument Sign: 18 inches maximum Monument Sign: Address lettering :::; ?inches (Helvetica) Wall Sign: 24 inches maximum if building area is > 35,000 te if 18 in. multiple signs are proposed. Area of Lettering & logo Logo Area= N/A Text Area= Total Area of logo and logotype = Percent coverage of Logo/logotype area may not exceed 1/3 of total sign area. N/A lettering and logo No standard for wall signs Lighting May be internally or externally lit None Location Monument sign: Near the primary access point to the lot. Wall sign: May not be mounted on any architectural projection, On concrete parapet, equipment enclosure or on glass portions of build in~! facade elevations The CRC Design Guidelines allow one wall or monument sign for buildings with an area of under 35,000 square feet. 1. The sign as proposed is fully consistent with the Design Guidelines of the CRC -~ Mission Equitites SKLZ HQ -West Side -Address Sign Re-Locaction -11149 EXISTING SIGN CONDITIONS PROPOSED CHANGES • SKLZ. G) WEST SIDE ADDRESS SIGN RE-LOCATION SIGN PERMIT NO. PS I d.-~3 APPROVED BY DATE SPECIFICATIONS FOR INS"tA.L..LATION: EXISTING ADDRESS NUMBERS TO BE REMOVEE PLANNING I L&/1/U.p...r~ 1 ~uet 'e' 1 BUD.J>ING RE INS"tA.L..L. NUMBERS TO NEW LOCATION SECURED WITH CONSTl<UCTlON G~E ADHESIVE SILICONE. ~~ ------------~-~-------- -__j I Lioll:745954 Clolilt...,.&Number -Jabl.aC8tiaii Scale:314"=1'on11"x17"Paper I n:.:=:.::,.":,==--: MISSION EQUmES 58~ Newtt:>n Dr #130 .,...,_ .....,,..,., .... .__.,....,......., -5-22-1.2 Initial Design-Tl.. _.,._,_"' C0644e Carlsbad, Ca 9.2008 ---.-....,&o.;gn.~no -- :::J AppnMod :::JAppnMod--o.ign Number = ~ :-] ~---, :::>~ Salee~ ~ ~,-----4---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------, ~ .i. "' ... WEST SIDE -Non-Illumina-ted Aluminum Pan Face Wall S ign SPECIFICATIONS FOR FABRICATION AND INS"'CALLATION: Non-illuminated pan face wall sign Quantity: one (1) Overall height of sign: 2 -0' Overall lengti-1 of sign: 9 -0' To't'c:ll: square feet: 18' Construction: .090 .Aluminum Face and ReTums 3 " in depTh Paint: "SLLZ' White ~ "l..OGO" PMS 7405 lns-tclled wiTh welded sTuds and spacers To tncnd-off wall 1". STuds secured wiTh Construction Grade )lo.dhesive S ilicone. 81 ©~&[N SIGN ~ 8r DESIGN, INC. 170 NAVA.JO S TREET SAN MARCOS. CA 92078 (C) 780.738.8'1'1'1 (fJ 780.738.8'1 2 '1 ~ 0Xll9 a.ar Sign. Deligr\.lne. Uc41:74S954 llw~nfltwoor'IOIP&llit,._.. .. .__,._,."~"""&Oooign. .... It'd m.tnat t;,.,..,.... b¥ "'¥ mDDd withcii.&IN.,.,.._,pilfTI'IIIIIanot .... ..... &,_. .... Appn>ood Appn>ood-- ~ o.c.. c::llnt N.me' & NUmbii' MISSION EQUITIES C0644.9 o.ignNumbw 1114.9 D~ -SKLZ Mission Equitites SKLZ HQ -West Side -Non-Illuminated Pan Aluminum Channel Letters -11149 9' Jab Luuotloiii 5823 Newtc>n Dr #130 Carlsbad, Ca .92008 "-'-'nee ~"""" l..A Project Ma~ SW Scal8: 314""1' on 11" x 17" Paper .,...,_....... 5-22-12 IniTial De•lgn -TL ~ SKlZ " BLACK PTM PMS 7405 ~~ •• r Spoc. tWAU.~ 2. D90 ALl.J"''NJM fi'oCe ,N-.0 RETURNS .3. waDED RIVET NUT~! 4. \01' XM' XJ.. 1r-~ S'T\JD, 1"'.~ 3P5RG~ 5. CONSTRUCT1C)N G~ 5LJCONE ....oHESNE SEOJRE5 sn.o. NEED TO HAVE WALL ME.ASURMENT CONFIRMED BEFORE FABRICATION .... • N ,. NORTH SIDE Non-Illumina-ted Aluminum Pan Face Wall S ign SPECIFICATIONS FOR FABRICATION AND INS~L.ATION: Non-illuminated pan face wall sign Quan1i1y. one (1) Overall heighT of sign: 2' -o· Overall lengl't1 of sign: 9 ' -o· TO'tc:ll: square feet: '18' Construction: .090 .Aluminum Face and Retums 3 ' in depth Paint: 'SL..LZ' Vv'hrte ~ 'L..OGO' PMS 7405 InsTalled witt! welded studs and spacers 1'a sTand-off wall 1'. Studs secured with Construction Grade .A.dhesive S ilicone. ©!lm&[f{ SIGN & DESIGN, INC. 170 NAVA.JO STREET SAN MARCOS , CA 92078 (t;J 780.738.8"'1"1"'1 (fJ 780.738.8"'12"1 COP"'mGMJ o 2009 a.or SIQn • DrNgn, m. Licll:745954 l'NI ~ ww:l ban:.ptll it,..._.. ... .. _ _, .. a-..,.,&,_....,_ rd ~nat be~ t,..,rT*hod .c:houl:thewrtt..l~of ao..."""&"""""m 0 App<owed ~ .. Noted Sigr-... Dote-------- Client Name & Number MISSION EQUmES C06449 o-ign Numb.- t114.9 03 -SKLZ Mission Equitites SKLZ HQ -North Side -Non-Illuminated Pan Aluminum Channel Letters -11149 9' 'JOb Luc:ootliin SB23 Newt-on Dr **130 Carlsbad, Ca 9::2008 "--""" ~ _D_S ___ , Project Ma""ll""'_ ~ Sc8J8:314'=1' on 11' x 17" Paper Ddo/RevtuOn 5-::2::2-1::2 Initial Design -TL ~ • SKlZ .• BLACK PTM ~~ • •• r Spoce • t~~E 2 090' AI..UMINUM MACE AND R:~S 3. WELDED RIVET NUT ~E 4-114' X M' AI.L. '1i-tREAD SnJO, MlNI"1UM 3PERG~ 5. CCNSTRl.ICT'ON G~ SILJCONE ADHESIVE SEClJRES S'TUO. NEED 10 I-lAVE WALL MEASURMENI CONFIRMED BEFORE FABRICAIION