Loading...
HomeMy WebLinkAboutPS 13-69; BLO DRY BAR; Sign Permits/Programs (PS)t: City of Carlsbad . , J.635 :Faraday Avenue Carlsbacl, CA 92008 · (760) 602-4610 PLANNING APPLICATION # ?~ l"?,'...(c,1 REC'D BYCnrt.!:a ~ . DATE 8 .-:..f3-j..3 . SIGNFEEe-, . . . SIGN PROGRAM FEE .· ~~~~~~~~~~ RECEIPT NO.----------------- REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum .of a site plan and sign elevations containing the following information: 1. · North arrow and scale. 2. Location of existing buildings c;>r structures, parking areas,, and vehicufar acc~ss points to the .property. 3. Location ofall existing and proposed signs for the property. 4. Pistance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the follpw.ing: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FO;RM, ;\ND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 · weeks NAME OF PROJECT, Gtn pr~ e, ar . . · . , ADDRESS OF PROJECT,1;us-q EJa.tUv q._0 rM · #to q ASSESSORi>ARCEL NUMBER: 2:() ~( q [ _..,, lfJ -0 0 . . . RELATED PLANNING CASE NUMBER(S): ----------------'----'---'---- TYPE OF DEVELOPMENT: (a) Residential (b) Commercial ( c) Office/Industrial (d) IIotel/Motel (e) (f) (g) (h) Service Station Prof. Care Theater Govt/Church · (i) Public Park (j) Produce Stand :(k) Nursery (1) P~U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes~ No D ~pecific Plan Number O {p -2: L{,q VILLAGE REDEVELOPMENT AREA Yes0 SJGN ORDINANCE: COAST AL ZONE: • • • • • • • • • Form 10 Revised 3/08 YesD YesD • • • • • • • • • • N~J&., Requires VR Approval No D N r-1, . ~~ •••••••••••• • • • • • Page 1 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERJA TOT AL BUil.,DING STREET FRONT AGE TOTAL SJGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSE!) SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN -.-, -- 11' fl ·It PROPERTY OWNER APPLICANT ft. sq. ft. sq. ft. sq. ft. sq. ft. sq. ft. NAME (PRINT OR TYPE) 'l.1 I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. PLANNER CHECK LIST: L Field check by planner. 2. Within maximwn length, area. I CERTIFY THAT I AM THE REPRESENTATIVE OFT E LEGAL OWNER AND.THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. 3'. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •!• . In right-of-way •:• In visibility triangle at corner 5. Pole and monwnent signs to be checked by Traffic Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ~ ~,uc;/-~ Date: i-Co-15 • • • • • • • • • l • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form IO Revised 3/08 Page 4 of 4 f . ... ·• EXISTING SIGNS: TYPE NUMBER SIGN AREA SJGNHEIGHT Pole Monument Wall Suspended .. Directional Canopy Yes D No D Date -------- PROPOSED PERMANENT SIGNS: TYPE MAxlMUM NUMBER MAXIMUM PROP<)SED MAXIMUM PROPOSED NUMBER PROPOSED SIGN SIGN SIGN SIGN ALLOWED AREA AREA HEIGHT HEIGHT Pole** Monument** Wall ( (J? 1{;~. -;;..l{ ti Suspended Directional .. Canopy · Freestanding** (Project I Identity) PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM . NUMBER· PROPOSED SIGN SIGN SIGN ALLOWED . AREA AREA HE For Sale** Banner *·*Prior to approval; all P. osed pole,· monument, and freestanding signs be reviewed for potential sight distanc d visibility issues. Additional information must supplement t lication showing how the-posed. s·ignage will not encroach into the public right-of-way ·or present a of 4 illustrates an example for what would be required for such proposed signs. . .. . . •· . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fonn 10 Revised 3/08 Page 2 of 4 0 MAIN ID WALL SIGN 3'-3 1/2" 11 1/2" 1 -~------- l 6.60 SQUARE FEET PLANNING ~ BUILDffiGL------------___.!!..-----__,~~ NEW REVERSE PAN HALO LETTER AND FCO · AG_LINE ·" ~~SC--A-te~~~" MANUFACTURE AND INSTALL (1) NEW WALL SIGN BLO -REVERSE PAN HALO LETTERS BACKS: 3/16" CLEAR LEXAN RETURNS: .063" ALUMINUM -PAINTED PANTONE PROCESS MAGENTA FACES: .080" ALUM -PAINTED PANTONE PROCESS MAGENTA ILLUMINATION: WHITE LEDS AND LED TRANSFORMERS ON 120V 20A DEDICATED CIRCUIT TAGLINE & TRADEMARK -1/2" ACRYLIC FCO'S -PAINTED PANTONE PROCESS MAGENTA PANTONE PROCESS MAGENTA HALO LETTER -TYPICAL SECTION .063" ALUMINUM RETURN 3/16"CLEAR LEXAN BACK --!1---11 .080 ALUMINUM FACE LED MODULES . LISTED BUSHING 11) PER LETIER 2"SPACER 1/4" DRAIN HOLES BOTIOM OF LETIERS ~· USTED TO 120V20A I DEDICATEDCIRCUIT DISCONNECT SWITCH AT PRIMARY N.T.S. PRIMARY ELECTRICAL (Nl;C 600-5) SEE ELEC. NOTES LED POWER SUPPLY FASTENERS AS REQUIRED PER LOCAL JURISDICTION (#10 X 3 SHEET METAL SCREWS WITH MIN. 1/2" EMBEDEMENT) 4 PER LETTER ALL PENETRATIONS SHALL BE WATERPROOFED APPROX.18ALOAO(l.EO) (1) 120V20ACIRCUrTREQUIREO ®='~tYAY ~ I'NCORP'ORAT'ED 1605 Ord Way • Oceanside, CA 92056 Ph; (760) 631-1936 Fax (760) 631-4987 www.ford-signs.com C-45·Lic. # 717137 SALESMAN: COLIN FORD PROJECT MANAGER: S.F. DRAWINGS BY: MIKE LEON CLIENT APPROVAL: LANDLORD APPROVAL: REV .No. DATE: CLIENT NAME: Bio· Blow Dry Bar JOB ADDRESS: 2659 Gateway Rd. # 104 Carlsbad, CA 92009 DATE: 8/5/2013 SCALE: NOTED SHEET NO# JOB NUMBER: BY; 1 of 3 13-210 PERMIT COPYRIGHT2010 FORD SIGNS INC. ALL DESIGNS PRESENTED ARE THE SOLE PROPERTY OF FORD SIGNS INC., AND MAY NOT BE REPRODUCED IN PART OF WHOLE WITHOUT WRITTEN PERMISSION FROM FORD SIGNS INC. ELECTRIC/IL TO USE U.L LISTED ~m~ COMPONENTS J\ND SHALL MEET I\LL N.e.c. STI\NOI\ROS ' LISTED FORD SIGNS INC. IS A STATE OF CALIFORNIA TITLE 24 COMPLIANT MAIN ID WALL SIGN PROPOSED CONDITIONS -SCALE: 1/4" = 1'-0" 18'-0" LEASED FRONTAGE -------------------- E.Q. 3'-3 1/2" E.Q. ---------·---<!--------+------- . . ..... ,, . ' . ' . " ~ I N C O R P O R A T E D 1605 Ord Way• Oceanside, CA 92056 Ph. (760) 631-1936 Fax (760) 631-4987 www.ford-signs.com C-45 Lie.# 717137 SALESMAN: COLIN FORD PROJECT MANAGER: S.F. DRAWINGS BY: MIKE LEON CLIENT APPROVAL: LANDLORD APPROVAL: REV .No. DATE: CLIENT NAME: Bio · Blow Dry Bar JOB ADDRESS: 2659 Gateway Rd. # 104 Carlsbad, CA 92009 DATE: 8/5/2013 SCALE: NOTED SHEET NO# JOB NUMBER: BY: 2 of 3 13-210 PERMIT COPYRIGHT 2010 roRD SIGNS INC. ALL DESIGNS PRESENTED ARE THE SOLE PROPERTY OF FORD SIGNS INC AND MAY NOT BE REPRODUCED IN PART OF WHOLE WITHOUT WRITTEN PERMISSION FROM FORD SIGNS INC ELECffiJCAL TO USE U.L. LISTED ~~~ COMPONENTS AND SHALL MEET ALL N.E.C. STANDARDS LISTED FORD SIGNS INC. IS A STAlE OF CALIFORNIA TITLE 24 COMPLIANT SITE MAP DETAIL ~ I N C O R P O R A T E D 1605 Ord Way• Oceanside, CA 92056 Ph. (760) 631-1936 Fax (76_0) 631-4987 www.ford-signs.com C-45 Lie.# 717137 SALESMAN: COLIN FORD PROJECT MANAGER: S.F. DRAWINGS BY: MIKE LEON CLIENT APPROVAL· LANDLORD APPROVAL: REV .No. DATE: CLIENT NAME Bio -Blow Dry Bar JOB ADDRESS: 2659 Gateway Rd. # 104 Carlsbad, CA 92009 DATE: 8/5/2013 SCALE: NOTED BY: SHEET NO# 3 of 3 JOB NUMBER: 13-210 PERMIT COPYRIGHT 2010 rDRD SIGNS INC. ALL DESIGNS PRESENTED ARE THE SOLE PROPERTY OF FORD SIGNS INC .. AND MAY NOT BE REPRODUCED IN PART OF WHOLE WITHOUT WRITTEN PFRMISSION FROM rORD SIGNS INC ELECTRICAL TO USE U.L. LISTED ~~~ COMPONENTS AND SHALL MEET _ ALL N.E.C. STANDARDS LISTED FORD SIGNS INC. IS A STAlE Of CALIFORNIA TITLE 2~ COMPLIANT