Loading...
HomeMy WebLinkAboutPS 14-157; AT&T; Sign Permits/Programs (PS)'I Ccicyof Carlsbad REVIEW FOR SIGN PERMIT p·.11 PLANNING AP Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov REC'D BY --!~~~~=:::::....,.,,.,-:-1.~-lh-=r"-- DATE SIGN F-E-E---::~~~·v=----r---r' ........... -r------- SIGN PROGRAM F~ ----'-...;;;+------------ RECEIPT NO. __,,_fa/l__f A"'--'A-_______ _ All plans submitted for sign permits/sign programs shall cons'ist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE~ The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: AT&T Authorized Re~ailer Address of Project:'Z<,,,?.S'via Campanile Suite 128 Assessor Parcel Number: ---------...----------------,----- Re I ate d Planning Case Number(S): ----------,------------ TYPE OF DEVELOPMENT: ~ Residential (d) H9tel/Motel (g) Theater 0) Produce Stand ~j ommercial (e) Service Station (h) Gov't/Church/School (k) Nursery c Office/Industrial (f} Prof. Care (i) Public Park (I) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes f?:l: No 0 Specific Plan Number f?.r 13-VE:, VILI • .AGE REVIEW AREA (If yes. please complete information on page 3) SOUTH CARLSBAD COASTAL REVIEW AREA SIGN ORDINANCE: Yesg]_ No D COASTALZONE: Yes-0 No~- P-11 Page 1 of4 YesB Yes No;. No ' Rev. 10/13 '! - EXISTING SIGNS: .TYPE NUMBER SIGN HEIGHT Pole Monument Wall Suspended/Projecting Directional Canopy ·Freestanding (Project Identity) PERMITS. ISSUED FOR EXISTING SIGNS: Yes O No 0 PROPOSED PERMANENT SIGNS: Date 11./13/14 MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** Wall 1 1 19sqft 19sqft 24" 24" Suspended/Projecting . Directional ·Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** -----For Sale** ~ ~ .. Banner ~ ----~ ----Interim --------· . ' **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional inform,tion must supplement this application· showing how ·ttJe proposed signage will not encroach into the public right· of-way or present a traffic .hazard. Page 3 of 4 illustrates an· example for what would be required for $UCh proposed signs. · P-11 Page 2 of'4 Rev. 10/13 SITE, PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the c_ounter. Additional time will be required for on,.site inspection. I I ]' I P/L • Sight Distance Requirement • I . Show building/s : I ·• • • I . . I , . I : Show setbacks from all curbs , _____ i --- ' . . I . I ' : I • I Show all property lines I : P/L ! . : I } • I • . curb line -. : • • : ----------.. -~- • • Sight Visibility I Street N arne(s) Ci) I I North 21.41.080 Sign design standards Relationship to, Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: _1_0_85 _______ sq. ft. Total Building Street Frontage: 1-9 linear ft. Total Signage Allowance: 19 sq. ft. Existing Signage (sq. ft.): 0 sq. ft. Remaining Sign Allowance at Present: 0 sq. ft. Proposed Signage (sq. ft.}: 19 sq. ft. Remaining Sign Allowance After Proposed Sign: 0 sq. ft. VILLAGE REVIEW AREA ' ' Total Signable Area: sq. ft. ~~~~~~.,......~- Tot a I Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of4 Rev. 10/13 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE} NAME (PRINT OR TYPE) Property Development Centers All Star Signs Inc MAILING ADDRESS ,. MAILING ADDRESS _C-!!tl q'7fr-11)-~9 5918 Stoneridge. Mall Rd 1924 W Mission Rd~r;f-e > . / CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Pleasanton, CA 94588-3229 Escondido, CA 92029 I CERTIFY THAT I AM THE; LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TOTH BEST OF MY KNOWLEDGE. ~~c Ni~fL !elt4-I~~ 11/13/14 - SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •:• In right-of-way •:• In visibility triangle at corner 5. Pole and monument signs to be checked by transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: [ ) , ~ . Date: f2-[J.-!cf P-11 Page4 of4 Rev. 10/13 .. •. nProperty Development . . Centers TENANT SIGN APPROVAL LETIER VIA ELECTRONIC MAIL November 12, 2014 Audra Hoffmann prioritysign 837 Riverfront Drive Sheboygan,Y\1153081 ~lIE<CEll~-:-~:~ i:;: !.:d Re: TENANT SIGN APPROVAL: AT~T FACILITY 2724: Carlsb9d -CA DEC 1 5 2014 CITY OF C.£,,~LSBAD PLAf\Ji\J/i\f,~, D/V/SVJi\J. AT&T proposed signage submittal was APPROVED. Please provide us.a final copy upon receipt of City permit approvals. 1,. A minimum of six inches must be kept from any wall edge transition (i.e. brick to stucco, brick to edge of storefront, etc ... ) and demising walls. 2. All signage must be fully weatherproof and shall be constructed of premium0 quality, weather resistant materials. All illuminated signs shall be fabricated and installed in compliance with all applicable building and electrical codes and shall bear an Underwriter's Laboratory (UL) label. No exposed raceways, crossovers or conduits will be permitted. All cabinets, conductors, transformers or other equipment related to lighting controls must be concealed from public view or accessibility unless they are an integral part of the design. All permits for signs and installation will be obtained by the Tenant, with a copy sent to the Landlord's Tenant Coordinator prior to installation. 3. The Tenant signs must meet all local sign code requirements and are the sole responsibility of the Tenant. 4. Installers must provide proof of licensing and insurance. Trucks must be substantial with outriggers. Installers must protect asphalt with plywood. Methods of installation must be acceptable to on-site tenant coordination. No truck parking on sidewalks or curbs is allowed. 5. Tenant's sign contractor is responsible for pulling all permits, including electrical, making sure all permits are finaled. Renata Flecchia Tyler Design Man~~er Property D1;Jvelopment Centers cc: TENANT FILE-, AT&T; PDC LEASING-STEPHEN LEWIS; PDA MANAGEMENT; SAFEWAY. REAL ESTATE LAW at&t Authorized Retailer EIUILOING 'T E;LEVATIOl't 1116"•1'-Q" f l AlPPROVED BY SIGN PEf'~Vf'iT NO. F.§ ( 't-I S-7 .DATE City/State: Carlsbad; CA BmLDThlG ..__ _____ ............... ___ _ Address: 2625 Via Campanile Suite 128 Creation Date: 07/22/2014 Revised: 10/10/2014, 11/04/2014, 11/17/2014 f i t l v I, -~-~=· ·=C=4=1=1=6=7======================================-~~~··~~~~,~ pnorrty~gn Reverse Channel Illuminated Letterset Black Faces AT&T copy and logo is halo illuminated reverse channel letters "Authorized Retailer" to be non-illuminated plate letters, stud mounted flush to fascia. Stroke of the non-illuminated letter is .65" "AT&T" Letter Section Detail (typ.) .063 aluminum~ letter return \ .125" aluminum face 120V power supply supply.wire--+-,~ 718"plast1cbushing -· ·.,.....,... · 3/8"flexible ' .· . ·-.. , ... 11:f' ' conduit I f source .080 Aluminum Tomocklight from face Globe Section Detail (typ.) White LED module----1--.-11 i~-r-Primary electrical .177"clearacrylic----+-+i 1 back · , -UL Listed disconnect, .177" clear acrylic 0 _ 1 single pole wtth rubber 1 .a ·~ h j boot l 1/4' dia. weep hole y,-1 f \ jfl ij wrth h:ht cover · _J \__ Secure mechanical O ·;au • .;;;;1 per site conditions 1/4' dia. weep hole~ 1 mounbng spacer fastener as required ']' - with hghtcover Reverse channel globe with digital print !" mounbng spacer 1. 3M #3635-30 White ,· UM #3630-8071.Light Blue 3. 3M #3630-8015 Dark Blue ® pnontys1qn .) Revisions: A 4. r,;nt,d •• ~ Satin Finish :k U Back Return Symbol .l77"thick Painted AT&T Clear GE Lexan Bnished Alum. Letters .177"thick Aluminum Pamled Clear GElexan Biack Sabn Finish uthorized .25" Alum Paint~d AT&T Retailer Plate Letters Black Hydro.Jet Cut Satin Interiors to be painted with Spray-Lat Star Bright Whtte Ligh_t ~nhancement paint. File'. Location: ArtDept\CorelCorors\AT&T B i-E j 1--D at& Dat~: 07·22•14 City/State Carlsbad, CA _o_es_ig_ne_r:_T_LD __ P_M_: _T_K Addre~s: 7825 Via-Campanile Suite 128 Site Nome r Scale: 3/8" = 1' ~I I Proposed Sign tocation