HomeMy WebLinkAboutPS 14-19; ALLSTATE; Sign Permits/Programs (PS). , .,..,
_ ...
-~ «~~ ¥ CITY OF
CARLSBAD
REVIEW FOR SIGN
PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
PLANNING APJ:;'UCATION # ·P514-/q
REC'DBY ~-~ DATE --i-,--~IE--,--,-,t4 ________ _
SIGN FEE $(eO _,
SIGN PROGRAM FEE _______ _
RECEIPT NO. ___________ _
All plans submitted for sign permits/sign programs shali consist of a minimum of a site plan and
sign elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing anq proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
Name of Project: _........,!....1....~.-==:~~~:!o,,_--=----,,------'-..,...,.---=------
Address of Project: ----=;.._.J, .......... _,__---'-4::.,...a.=--.:......,~.:..L.~~~~---...:;;::;::,...-----
Assessor Parcel Number: -----------------------Relateq Planning Case Number(S): ___________________ _
TYPE OF DEVELOPMENT:
(a) Residential
(b) Commercial
( c) Office/Industrial
(d) Hotel/Motel
( e) Service Station
(f) Prof. Care
(g) Theater
(h) Gov't/Church
(i) Pl,iblic Park
0) Produce Stand
(k) Nursery
(I) P-U/0S Zone
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesW NoD
Specific Plan Number ____ _
VILLAGE REVIEW AREA (If yes. please complete information on page 3) Yes D
SOUTH CARLSBAD COASTAL REVIEW AREA Yes 0
SIGN ORDINANCE: Yes O No 0
COASTAL ZONE: Yes O No 0
P-11 Page 1 of4
No~
NoB-
Rev. 06/12
.?
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument
Wall ;).. ';.)3~ ~ If<'' /Zl/u
Suspended
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes~ No 0
PROPOSED PERMANENT SIGNS:
Date 9 ..... ______ _
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER SIGN SIGN SIGN
ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT
Pole**
Monument** (£ e I g,, (_~~
Wall 2. ~ il-01\ ~'3,d-(t ~ l'i" I :!Jt,
Suspended '
I
Directional
Canopy
Freestanding**
(Project Identity)
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-
of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be
required for such proposed signs.
P-11 Page 2 of4 Rev. 06/12
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I 1 I
P/L • Sight Distance Requirement
• I
Show buildin1/s I I
I I
It I
: I
~---{-Show setbacks from all curbs ---
I I I I
I I I Show all property Jines I
P/L : I I
' ~ ·: I
curb line • I I • ----------~---
• •
Sipt Visibility I Street Name(s} (i) I
I North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or c~mstructed so that it impairs the sight
distance requirements ;3t any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
Total Building Square Footage: ---~----sq. ft.
Total Building Street Frontage: d---l linear ft.
Total Signage Allowance: ~ ~\ ·'? sq. ft.
Existing Signage (sq. ft.): J2f(a.rri,xe4~sq. ft.
Remaining Sign Allowance at Present: ?Jl , ? sq. ft.
Proposed Signage (sq. ft.): :).. 3,-:}_ sq. ft.
Remaining Sign Allowance After Proposed Sign: t-9',, ;g'. 6 (~ sq. ft.
VILLAGE REVIEW AREA
Total Signable Area: ________ sq. ft.
Total Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3of4 Rev. 06/12
PROPERTY OWNER
· NAME PRINT OR TYPE
MAILING ADDRESS
I CERTIFY THAT I AM THE LEGAL OWNER
AND THAT ALL THE ABOVE INFORMATION
IS TRUE AND CORRECT TO THE BEST OF
MY KNOWLEDGE.
SIGNATURE DATE
PLANNER CHECK UST:
1. Field check by planner.
2. Within maximum length, area.
APPLICANT
NAME PRINT OR TYPE
MAILING ADDRESS
I CERTIFY THAT I AM THE REPRESENTATIVE
OF THE LEGAL OWNER AND THAT ALL THE
ABOVE INFORMATION IS TRUE AND CORRECT
TO THE BEST OF M KNOWLEDGE.
SIGNATURE
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4.
5.
6.
Location: •!• In right-of-way •!• In visipility triangle at corner
Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
When approved route copy to Data Entry
APPROVED: Planner: 61'<-__________ ___,;. ________ _ Date:___.:f-/'-----+~/i_t _,_f_
P-11 Page 4 of4 Rev. 06/12
. .,
' <.'
~-
~
00 n,;
,j
:~
F-<l t~
I 1-~ f.q
::i
)
k;J
f,\1
7 ,,,..
~ t1j
~ -~ ~
\ ~
t
/!I ~ i
f~ ~
~ ~ ~ ~
'--' """'-'-'l '• . ' :,
' .1
-
i ~ g
~
l ~.-.... ~ . ..,...~. r;_r.~~ .. ,·:.:. -:.,_~~
E01 P01 ALST.WS1 .AO_ 16 Rmv&Repl
E02 P02 ALST.CUST.SIGN Rmv&Repl
c,c~, ---,,-,,;··,;· -~ -------·. ' '
1 H~1'·i,t·: J1 ~tt'
C'_.c•~'., .. 7' , __ ;;:, l!i._,,_.:: ,'<.cs.:., ~: • ,/.}f1~~:ff P:. ,~-_ .• _ .. -~;v'~~~l•~,_.::
,.d~~·N,,,~,L~,. . ... J1't, _____ ,.~ --~-w Allstate
~ PHILADELPHIASIGN
Fi a i ,.,i i-; i rJ .r; r -t F w,1 n e f n · <. rt R .t :·, n i; T n . F F
707 West Spring Garden Street
Palmyra, NJ 08065-1798
LOCATION: CA582 -CA
Hazelrigg Insurance Agency, Inc.
6994 El Camno RI .
Carlsbad, CA
THIS IS AN ORIGINAL
UNPUBLISHED DRAWING
CREATED BY PHILADELPHIA
SIGN IT IS ·suBMITTED FOR
YOUR PERSONAL USE IN
CONJUNCTION WITH A PROJECT
BEING PLANNED FOR YOU BY
PHILADELPHIA SIGN IT IS NOT TO
BE-SHOWN TO ANYONE OUTSIDE
YOUR ORGANIZATION NOR IS IT
(
~. --r·
E01 ALST.WS1.A0_16 2'h x 8' 1-3/16"w tnurrfiriated "Allstate Only" Linear Wall Sign (16 SF) Existing
~~~rI}0?:::.:;r~r~~r~TT:I0;r;, llh':.;;.:~-;~5~,.~~>~1;-;:.j,,,:;;;.,~f.t!!''¾;..?,Ji:!s.."".~~2~;.f:::-;,\
' ' -~~
',: ...... -; ·;-,' ,,,':..,.-r:J ;,,_~;~;~·,:_._71,,r:·,-;;r-;.---:,_
},',
__ ... ,
"' -'!:So~~· .;,J-
(:\
H liif'
PHILADELPHIASIGN CLIENT: ALLSTAT C DATE: REVISION: E -A 10/17/2012 09.18.13 DRM Revised N01 & E06
8 R I N G t .. ~ G T ; F \'VO ",l l ~ ' :; g R A h D S Y f> . r" f
707 West Spring Garden Street
Palmyra, NJ 08065-1798
LOCATION: CA582 SHEET: 12.31.13 DRM Revised E02
Hazelrigg Insurance Agency, Inc P01
6994 El Camno RI DWG BY·
Carlsbad, CA RPV
THIS IS AN ORIGINAL
UNPUBLISHED DRAWING
CREATED BY PHILADELPHIA
SIGN IT IS SUBMITTED FOR
YOUR PERSONAL USE IN
CONJUNCTION WITH A PROJECT
BEING PLANNED FOR YOU· BY
PHILADELPHIA SIGN IT IS NOT TO
BE SHOWN TO ANYONE OUTSIDE
YOUR ORGANIZATION NOR IS IT
,)
•
ENGINEERING
SHOP
VINYL/ LAYOUT
ROUTING / KNIFE
=
9 N
3 5/8" 1'-6 II
r-Shut Off Switch
/ &Photo Cell
~ ('I')
co _, .....
7
Thermoformed Cyro SG .177 -1
Thick White #W7328 Formed
w/1st Su~ce (Laminated) 3M
Sultan Blue 3630-157 Backed
w/White Block but #3635-20B.
l,.ogo & Allstate To Be Dropped
Out To Illuminate White. Trap
Face With #8 x 3/4" Long
Push Studs & Nuts
Electrical Load
{1.12)Amps@ 120 Volts
Electrical Reg'mts
(1) 20 Amp/120 Volt Circuits
STANDARD WALL SIGN NOTES:
1. Sufficient Primary Circuit In Vicinity Of Sign
By Others.
2. Final Primary Hook-up By Sign Installer,
Where Allowed By Local Codes.
3. Sign Shall Be U.L. Listed.
4.-Mounting Hardware By Sign Installer.
1'-6 II
Note: This sign is intended to be installed in .accord_ance with the requirements of
Article 600 of the National Electrical Code and/or other applicable local codes.
This includes p_roper grounding and bonding. of the sign.
8'-1 3/16" (Overall Sign Width)
7'-8 5/8" (Blue Background)
1'-6 II
ELEVATION VIEW
E01 -ALST.WS1.AO 16
16 Sq Ft Wall Sign
SCALE: 1" = 1 ''-0"
Pl:01\MrtS
llMlal
1'-6" 1'-6"
.090" Thick Routed & Pan Formed
Aluminum Face Painted
MP789535V-VER1 .0 Silver
(Satin Finish)
3 5/811
Extruded Case #36898 ----------
Painted MP789535V-VER1 .0
Silver {Satin Finish)
1-1/2" Open Aluminum Hinge-----
V-Notched & Welded To Face &
Screwed To Casing w/#10-1/2"
Pan Head Screws
.090" Thk Routed & Pan Formed >ii
Aluminum Face Painted
MP789535V-VER1 .0 Silver
(Satin Finish)
Attach To Building With 1/2" Dia
Lag Bolts. (12) Places
{Staggered Drill Pattern)
3/8" Diameter Hex Head Bolt---~
(6) Places
2-1/2" X 2-1/2" X 3/16" Thick ___ _.,..
Continuous Aluminum Angle
With Trap Nut To Secure Bolt
½" Diameter Flexible Conduit. __ __/
Power Out Side Of Raceway.
Existing Electric To Be Utilized.
(2) 96" T12/DL/HO Lamps
w/Butt-on Sockets
.040 White Precoat Alum Back
Pop Riveted Tel Sign Casing
Thermoformed Cyro SG .1.77
Thick White #W7328 Formed
w/1st Surface (Laminated) 3M
Sultan Blue 3630-157 Backed
w/White Block but #3635-20B.
Logo & Allstate To Be Dropped
Out To Illuminate White. Trap
Face With #10 x 3/4" Long
Threaded Studs w/Nylon-lnsert
Hex Locknut & Nylon Washer
Photocell---------
16 Amp Shut-off Switch ---~
Located At End Of Raceway
120V Electronic Ballast ----
ESB216-12@ 1.12Amps Each
1/4" Drain Hole (Max 48" O.C.) ------~
6-3/8"
51/2"
., ... -;-... ,
,' /"'~ ... , \ ,-c,-;·, \ ,.!,, I
' .... ..!.. ... '
j<,.{al_
I '-. . '-..,. " . /"--
-· • 1-... 1---,---------, SECTION
SCALE: 3" = 1'-0"
• e---lJllck
""" ESB216-12 Ballast -ump
'-'mp
...f----------..J
NOTE: CapAny Red/Blue Wire Leads Not Used
Wiring Diagram
If Substitute Ballast is to be Used, Please Referto Ballast Manufacture Label for Correct Wiring
~
PHILADELPHIASIGN
BRINGING THE WORLD'S BRANDS TO LIFE
707 West Spring Garden Street
Palmyra, New Jersey 08065
Phone: 856.829.1460
Fax: 856.829.8549
www.phlladelphiaslgn.com
CUSTOMER:
ALLSTATE
JOB NUMBER:
CA582
SIGN TYPE:
ASLT.WS1.A0_16
LOCATION:
6994 El Camino Real
Carlsbad, CA
DATE:
02/05/2014
DRAWN BY:
JTR
REVISION:
Number: Date: By:
SHEET: ENG DEPT
1 OF 1
DWGNUMBER:
B53623
ENGINEER SEAL:
MAX DESIGN WIND SPEED 90 MPH
EXPOSUREC
THIS IS AN ORIGINAL IINPUBLISIED DRAWING
CREATED BY PSCO. IT IS SUBMITTI:D FOR YOUR
PERSONAL USE IN CONJUNCTION WITH A PROJECT
BEING PUNNED FOR YOU BY PSCO. IT IS NOT TO
BE SHOWN TO ANYONE OUTSIDE YOUR
ORGANIZATION NOR IS IT TO BE USED, COPIED,
REPRODUCED, OR EXHIBITED IN ANY FASHION.
•
·-) E02 ALST.CUST.SIGN Custom Sign -18-1/4"h x 204"w R/W 18"h Logo Existing
PHILADELPHIASIGN
&RINGlN~""; T-i~ WOl!D'5 !!.RAr-,ns TO. FF
707 West Spring Garden Street
Palmyra, NJ 08065-i 798
~.: .~ Existing Sign
·.' _:~ \·
'.' ... ',r '<'' :·
.\ ·{
. ?
·,,
f
.,:_.__,.::_...., ........... _~_c:-:-~ ·--~' ....,......_ .......... ---··......,..._~, .. -·~-..i:~-... .-.-' . . . i
-... --~~,....._,;~..,.._ lo•~·· •!,oJ .......t,,jl
CLIENT: ST C DATE: REVISION: ALL ATE -A 10/17/2012 09:18.13 DRM Revised N01 & E06
LOCATION: CA~82 SHEET: 12.31.13 DAM Revised E02
Hazelrigg Insurance Agency, Inc P02
6994 El Camno RI · DWG BY·
Carlsbad, CA RPV
THIS IS AN ORIGINAL
UNPUBLISHED DRAWING
CREATED BY PHILADELPHIA
SIGN IT IS SUBMITTED FOR
YOUR PERSONAL USE IN
CONJUNClJON WITH A PROJECT
BEING PLANNED FOR YOU BY
PHILADELPHIA SIGN IT IS NOT TO
BE SHOWN TO ANYONE OUTSIDE
YOUR ORGANIZATION NOR IS IT
.,
y ENGINEERING
SHOP SQUARE FOOTAGE: 25.85
,')\~N ~ ·1 tZsf: VINYL/ LAYOUT
ROUTING / KNIFE
~ ..... ::= ~o~ -.-ca ...-.c c::
~-~Cl ...-:c .5 ......... ·en ·x w
½" Diameter
Flexible Conduit.
Shut-off Switch and Photocell
1-1:
C) ~,l
:;... 0 C)
1.3 ,-
1'-10 13/16"
17'-0" (Raceway Leng_th)
8'-0 1/8"
5'-10 1/16"
Sta
1/8" Thick Bent Aluminum Custom Raceway
18-1/4" High x 204" Wide x 7" Deep.
Raceway To Be Painted To Match Dunn
Edwards Paint Color West Bluff Yellow
(Satin Finish)
Logo Face To Be 1/8" Thick #7328
White Acrylic With Arton Translucent
Sultan Blue Vinyl #157 Applied
ELEVATION VIEW
E02 -ALST.CL.B 15
Letter Faces To Be 1/8" Thick #2447 White
Acrylic w/ 1st Surface (DAY/NIGHT) Perforated
Opaque Vinyl (Blue #3944) To Match Arion
Translucent Sultan Blue Vinyl #157 1st Surface
NOTE: Sign To Be.Marked OSTD
Due To The Size Of The Logo
NOTE: All Dimensions To Be Verified
From Site Survey Before Releasing
For Fabrication
\>EI\M\lS
ONll
Estimated El1ctrical Load
(1.26)Amps@ 120 Volts
Electrical Reg'mts
(1) 20 Amp/120 Volt Circuits
STANDARD LETTER NOTES:
1. Sufficient Primary Circuit In Vicinity Of Sign
By Others.
2. Letter To Letter Wiring & Final Primary Hook-up
By Sign Installer, Where Allowed By Local Codes.
3. Sign Shall Be U.L. Listed.
4. Mounting Hardware By Sign Installer.
5. Full Size Drilling Template Furnished With Sign.
Note: This sign is intended to be installed in' accordance with the requirements of
Article 600 of the National Electrical Code and/or other applicable local codes.
This includes proper grounding and bonding of the sign.
15"h Ilium D/N Blue Letters w/ 18"h Custom Logo
SCALE: 3/4" = 1 '-0"
4"0.A.W. 7"
#8 x 1/2" PH Phillips
Stainless Steel Screws
(As Required All Around)
1" Metallic Silver Jewelite
Trimcap. Attached Using
Methylene Chloride
Followed By IPS Weld-On
40Wrth#8x½" PH
Phillips S.S. Screws
(As Required All Around)
Bitro TriMAX Pure White --
LED's As REQ'.D For
Even Illumination. (.69w ea.)
Logo Face To Be 1/8" Thick #7328
White Acrylic With Arion Translucent
Sultan Blue Vinyl #157 Applied
1st Surface
Letter Faces To Be 1/8" Thick #2447
White Acrylic w/ 1st Surface
(DAY/NIGHT) Perforated Opaque Vinyl
(Blue #3944) To Match Arion
Translucent Sultan Blue Vinyl #1 S7
.050 Pre-Coat White ----
Aluminum Back
Chase Nipple ------
Attach Letters To Raceway With
#10 x 3/4" Hex Head Screws
Stapled Construction
4" x .040 Wht/Silver Alum.
CoilRetum Stapled To .050
Routed Aluminum Back.
1/4" Diameter Drain Holes -----~
With Light Covers
----3/8" Diameter Non-Corrosive
Hardware To Suit Existing
Conditions. (Stagger)
1/8" Thick Bent Aluminum Custom Raceway
18-1/4" High x 204" Wide x 7" Deep.
Raceway To Be Painted To Match Dunn
Edwards Paint Color West Bluff Yellow
(Satin Finish)
1" x 1" x 1/8" Thick Aluminum
Angles All Around Every 48"
To Stabilize Cabinet.
...___ ½" Diameter Flexible Conduit.
Power Out Side Of Raceway.
Existing Electric To Be Utilized.
1111,c 1/8" Thick Aluminum Back Panel.
D)c I 1111 Photocell
lr---t-C I 1111 BITRO -ASU-60-12U 60
Watt LED Power Supply
(.58 Amps Each).
@-,c I l~I 16AmpShut-offSwitch
SECTION VIEW
SCALE: 3" = 1 '-0"
Located At End Of Raceway
#12 x 3/4" Long Tek Screws.
~
PHILADELPHIASIGN
BRINGING THE WORLD'S BR.ANDS TO LIFE
707 West Spring Garden Street
Palmyra, New Jersey 08065
Phone: 856.829.1460
Fax: 856.829.8549
www.philadelphlasign.com
CUSTOMER:
ALLSTATE
JOB NUMBER:
CA582
SIGN TYPE:
Channel letters
LOCATION:
6994 El Camino Real
Carlsbad, CA
DATE:
01/15/2014
DRAWN BY:
JTR
REVISION:
Number: Date: By:
SHEET: ENG DEPT
1 OF 1
DWGNUMBER:
B53074
ENGINEER SEAL:
MAX DESIGN WIND SPEED 90 MPH
EXPOSUREC
THIS IS AN ORIGINAL UNPIIIUSIED DRAWING
CREATED BY PSCO. IT IS SUBM111ED FOR YOUR
PERSONAL USE IN CONJUNCTION WITH A PROJECT
BEING PUNNED FOR YOU BY PSCO. IT IS NOT TO
BE SHOWN TO ANYONE OUTSIDE YOUR
ORGANIZATION NOR IS IT TO BE USED, COPIED,
REf'!l()DIICED, OR EXIIBITED IN AJfY FASHION.