HomeMy WebLinkAboutPS 14-87; SportClips; Sign Permits/Programs (PS),1_·...-.... ,~.'1:.---------------------------------------------------------------~ Vr ,.: ~
«t#>> ~ CITY OF
CARLSBAD
REVIEW FOR SIGN
PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadc.:a.gov
PLANNING~ION# PS /4--83:
REC'D.f3Y~ ~
DATE ri-a1~=c..( . . _ SIGN FEE _Jf£'2Q . = SIGN PROGRAM FEE ________ _
RECEIPT NO.-----------
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and
sign elevations containing the following information: .
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sigh(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of illumination.
D. Proposed sign copy.
APPLICANT . MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM,. AND THE APPLICATION FEE.
The application must ~ submitted rufyf to 4:00 p.m. Average processing time: 2 weeks
Name of Project:. 5/orf'r-'7 ~u/ ~ . . .
Address of Project: _ I I a O A: J O .2... . fi<J -e.v I 1. _ f.rv~~ j.
Assessor Parcel Number:-----------------------,--
Related Pl~nning Case Number(S): _______________ _;... ___ _..;..._
TYPE OF DEVELOPMENT:
(a) Residential (d) Hotel/Motel (g) Theater
(b) Commercial (e) Service Station (h) Gov't/Church/School
0) Produce Stand
(k) Nursery
( c) Office/Industrial (f) Prof. Care (i) Public Park (I) P-U/OS Zone
SIGN PRO.GRAM AND/OR SPECIFJC PLAN CRITERIA Yes.D NoO
Specific Plan Number ___ _
VILLAGE REVIEW AREA (/fyes, please complete information on page 3) Yes D No D
SOUTH .CARLSBAD COASTAL REVIEW AREA . Yes O No 0
SIGN ORDINANCE: Yes O No 0
COASTAL ZONE: Yeso· 'NoD
P-11 Page 1 of4 Rev. 10/13
V
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument
Wall I ,1.~r~. $£A-z 3>'
Suspended/Projecting
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ------
PROPOSED PERMANENT SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER SIGN SIGN SIGN
ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT
Pole**
Monument**
Wall J t /o.-6~,
..
Suspended/Projecting
Directional
Canopy
Freestanding**
(Project Identity}
qigital Display
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER SIGN SIGN SIGN
ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT
Cpnstruction**
For Sale**
Banner --
Interim
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight dl!Ctance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-
of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be
required for such proposed signs.
P-11 Page 2-of4 Rev. 10/13
r
l
SITE: PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed '
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection. -
I I l I
P/L 1 Sipt Dist81\ce Requirement
Shaw buildin&/s I I
I
I
~---1' I
Shaw setbacks from all curbs
I I I I I I I Shaw all property lines I
P/L : I
:/ I
curb line i
----------.-.-- -
• •
Sipt Visibility I Street Name(s) (i) I
I North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed· and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any·
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or construct~d so that it impairs the sight
· distance requirements at any public or private street intersection or driveway.
· EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
Total Building Square Footage: sq. ft.
~~~~~~~~
Total Building Street Frontage: linear ft.
Total Signage Allowance: sq. ft.
Existing Signage (sq. ft.): sq. ft.
Remaining Sign Allowance at Present: sq. ft.
Proposed Signage (sq. ft.): sq. ft.
Remaining Sign Allowance After Proposed Sign: sq. ft.
VILLAGE REVIEW AREA
Total Signable Area: sq: ft. ~~~~~---~~
Total Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3 of4 Rev. 10/13
PROPERTY OWNER
.NAME PRINT OR TYPE
MAILING ADDRESS
Cir( STATE ZIP TELEPHONE
I CERTIFY THAT I AM THE LEGAL OWNER
AND THAT ALL THE ABOVE INFORMATION
IS TRUE AND CORRECT TO THE BEST OF
MY KNOWLEDGE. .
SIGNATURE DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
APPLICANT
NAME PRINT OR TYPE
MAILING ADDRESS
CITY STATE ZIP TELEPHONE
tt U'ff"/ C,4-f>(};,,o , ~vi · ~::s
I CERTIFY THAT I AM THE REPRESENTATIVE
OF THE LEGAL OWNER AND THAT ALL THE
ABOVE INFORMATION IS TRUE AND CORRECT
TO THE BEST OE Y OWLEDGE.
SIGNATURE DATE
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: •!• In right-of-way •!• In visibility triangle at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When· approved route copy to Data Entry
APPROVED: , Planner:------------------Date: --------
P-11 Page4of4 Rev. 10/13
-------------------------------------
August4,2014
CCAR CLIPS, LLC
1944 Diamond Street, Suite 1
San Diego, California 92109
DONAHUE SCHRIBER
RE: Sign Response for SportC/ips
Poinsettia Village II
Carlsbad, California
The sign submittal received at our office for the above-referenced project has been
reviewed · and approved as noted. Please use the comments noted on the
drawings and the guidelines listed below to make any necessary adjustment to
your documents and the installation of your sign.
1. All signs shall be reviewed for conformance. with the sign criteria and overall
de.sign quality and is not a plan check for dimensional errors, code
violations or any other restrictions to the property. Approval or disapproval
of .sign submittals based on aesthetics of design shall remain the sole right
of the Landlord/Manager ..
2. Prior to the installation and manufacture of any sign, the Tenant shall
provide Landlord. with a copy of the sign permit from the governmental
agency having jurisdiction. ·
3. Each tenant shall be responsible to repair any damage to _any surface
9aused by the signage or its' installation.
4. Landlord reserves the right to periodically hire an independent electrical
engineer, at Tenant's sole expense, to inspect the installation of all Tenants'
signs. Tenants shall be required to have any discrepancies and/or code
violations corrected at Tenant's expense. Any code violations, requests for
sign removals, or discrepancies not corrected within fifteen (15) days of
notice, may be corrected by the Landlord.at Tenant's expense.
5. Upon vacancy, Tenant shall. remove .sign and restore· fascia to original
condition at Tenant's sole cost and expense within fifteen (15) days of
expiration of term .or earlier termination of Tenant's lease.
200 E. Baker Street
Suite 100
Costa Mesa, CA 92626
(714} 545-1400
FAX: (714) 545~4222
donahueschriber.com
Lie. 01875932
Augu~t 4, 2014
SportClips
Poinsettia Village II
· Page 2
6. Exposed junction boxes, transformers, lamps, tubing, conduit, or raceways
of any type are NOT PERMITTED. .
7. Sign manufacturer's names, stamps, or de.cats may not be visible from the
. street or normal viewing angles·. .
8. Tenant's sign contractor: shall install and connect sign display and primary
wiring at sign location approved by Landlord. Signs are to be connected to
the J-box provided by the Landlord, which is connected to the Landlord's
house panel, and shall be wired to Landlord's control at Landlord's timer for
uniform control of hours of illumination unless otherwise directed by
Landlord.
9. Prior to sign installation, we require the following:
a. A copy of your sign contractor's insurance certificate naming Donahue
Schriber Realty Group, LP.; Donahue Schriber Realty Group, Inc.;
Donahue Schriber Asset Management Corporation and all related
affiliates, as additional insured (with additional insured endorsement
page attached).
b. A copy of the permit .and the contractor's license.
c. At least 48 hour notice of date of install and requesting access to
electrical room, if required.
Should any other contractor provide installations or other work on the site,
please call me to coordinate insurance requirements.
In the event that the above information contradicts the lease signage criteria, the
lease signage criteria are to supersede. Should you have any questions, please
call me at 858.793.5757, Ext. 12. ·
Sincerely,
DONAHUE SCHRIBER
~r-ti~N
Don Armstrong
Director, Construction
cc: Jackie Check, DSRG
File
The original drawings,
designs, ideas and
arrangements contained
herein are copy written
and shall remain the
property of San Diego
Electric Sign, Inc.
No part therefore may
be copied or reproduced
~nd used in connection
with any other work or
project other than the
specific project for which
they have been prepared,
without consent from
San Diego Electric Sign,
Inc.
If upon submittal to a
proposed client these
drawings are not
released with the afore
mentioned consent.
these drawings shall be
promptly returned to
San Diego Electric Sign.
Inc., and furthermore,
signs shall not be
produced in the likeness
of these designs.
SAN DIEGO ELECTRIC SIGN, INC., USES
GREEN TECHNOLOGY LED WITH UPTO
S·YEAR MATERIALS WARRANTY, ASK
YOUR SALES PERSON FOR DETAILS.
@
~~iego E.!fl.cf t:ic .s'i9.n,*
INSTALLATION I DESIGN I FABRICATION 1111 CA LIC #750379
1920 CORDELL CT #103, EL CAJON CA 92020 PH 619.258.1775 FAX 619.258.1805
THESE PRINTS AND THE DESIGNS HEREIN ARE THE PROPERlY OF SAN DIEGO ELECTRIC SIGN, INC., AND THE SIGNS OR DESIGNS HEREIN MAY NOT BE REPLICATED, DUPLICATED DR COPIED IN ANY MANNER, AND MAY NOT BE USED FOR THE PURPOSE OF OBTAINING COMPETITOR
BIDS. UPON OBTAINING A FULLY EXECUTED DISPLAY PURCHASE AGREEMENT AND DEPOSIT, SAN DIEGO ELECTRIC SIGN, INC., MAY ELECT AT THEIR DISCRETION TO TRANSFER THE DESIGNS HEREIN TO THE CLIENT.
-~
~
INTERSTAY.E.5
SICiN TYPE SQ. FT.
FRONTLITCHANNEL 11.58 LETTERS
Property Address : 7180 Avenlda Enclnas Carlsbad, CA
Parcel ID: 214-430-19-00
Old parcel ID : 214-430-01-00
Map Number: PM15187
PHOTO OVERLAYS AND RENDERINGS ARE FOR PLACEMENT REFERENCE ONLY AND MAY NOT BE TO SCALE. PLEASE REFER TO THE PRODUCTION PAGE WITH MEASUREMENT
CALL OUTS FOR THE SPECIFIC SIZE/SCALE OF YOUR SIGN. NIGHTTIME VIEW SHOWN MAY NOT REFLECT REAL LIFE LIGHTING CONDITIONS.
THESE PRINTS AND THE DESIGNS HEREIN ARE THE PROPERTY OF SAN DIEGO ELECTRIC SIGN, INC., AND THE SIGNS OR DESIGNS HEREIN MAY NOT BE REPLICATED, DUPLICATED OR COPIED IN ANY MANNER, AND MAY NOT BE USED FOR THE PURPOSE OF OBTAINING COMPETITOR
BIDS. UPON OBTAINING A FULLY EXECUTED DISPLAY PURCHASE AGREEMENT AND DEPOSIT, SAN DIEGO ELECTRIC SIGN, INC., MAY ELECT AT THEIR DISCRETION TO TRANSFER THE DESIGNS HEREIN TO THE CLIENT.
N
0
~a~iego
!!le.cf tic .s'i9!!::.
INSTALLATION• DESICiN· FABRICATION /Ill CAucmom
Client: SPORT CLIPS
Job: FAC!: LIT CHANNEL LETIERS
Address: 7180AVENIDAENCINAS H102
CARLSBAD CA 92011
Salesperson: WARD LANNOM
Date: 6/17 /14
Drawing#:A
Revisions:
Rl: Change uClips~ to white;
Made Permit Prints.
R2: Revised Logo box to aluminum face with
push thru copy.
R3: Change tagline to FCO acrylic (non-illum.)
ARTTIME DATE REVISION NUMBER
1.50 6)17/14 PRELIMINARY PRINTS
1.00 7/22/14 PERMIT PRl!'ITS-R1
o,so 7/29/14 PERMITS PRINTS-R2
o:!!o 7/30/14 PERMIT PRINTS•R3
5 1'?.t!~i~PS
Provldlng electrical to the sign locatlon ls the
responslbility of others. San Dlego Electrlc Slgn, Inc.
Does NOT provlde electrlcal to the slgn locatlon.
CUSTOMER APPROVAL OF·DESIGNS:
Client Signature Date
Landlord Signature Date
PAGE 2 OF 6
EQ
EQ
. nsae J0 1 / ll/'io,( . t. . o \0 t..:,! um n 'T-t>
·oluYV\Y\
EQ ·. 9'-3~
Ir.II SIMULATED DAYTIME PHOTO OVERLAY
Iii SCALE: 1/4" = 1'-0"
FACE LIT CHANNEL LEITERS
"SPORT" LETTERS TO HAVE RED ACRYLIC FACES WITH RED LED ILLUMINATION
"CLIPS" LETTERS TO HAVE WHITE ACRYLIC FACES WITH WHITE LED ILLUMINATION
LETTERS HAVE BLACK TRIM CAP AND BLACK ALUMINUM RETURNS
SIMULATED NICiHTTIME PHOTO OVERLAY
SCALE: 1/4" = 1'-0"
"HAIRCUTS" TAGLINE: 1/2" FLAT CUT OUT NON-ILLUMINATED ACRYLIC PAINTED BLACK &
PEGGED OFF WALL 1/2"
PHOTO OVERLAYS AND RENDERINGS ARE FOR PLACEMENT REFERENCE ONLY AND MAY NOT BE TO SCALE. PLEASE REFER TO THE PRODUCTION PAGE WITH MEASUREMENT
CALL OUTS FOR THE SPECIFIC SIZE/SCALE OF YOUR SIGN. NIGHTTIME VIEW SHOWN MAY NOT REFLECT REAL LIFE LIGHTING CONDITIONS.
THESE PRINTS AND THE DESIGNS HEREIN ARE THE PROPERTY OF SAN DIEGO ELECTRIC SIGN, INC, AND THE SIGNS OR DESIGNS HEREIN MAY NOT BE REPLICATED, DUPLICATED OR COPIED IN ANY MANNER, AND MAY NOT BE USED FOR THE PURPOSE OF OBTAINING COMPETITOR
BIDS. UPON OBTAINING A FULLY EXECUTED DISPLAY PURCHASE AGREEMENT AND DEPOSIT, SAN DIEGO ELECTRIC SIGN, INC., MAY ELECT AT THEIR DISCRETION TO TRANSFER THE DESIGNS HEREIN TO THE CLIENT.
'
0 . ~/ti ego
l!.lecfcic .s'i~
INSTALLATION• DESIGN• FABRICATION W CAUC"7S0379
Client: SPORT CLIPS
Job: FACE LIT CHANNEL LETTERS
Address: 7180 AVENIDA ENCINAS H102
CARLSBAD CA 92011
Salesperson: WARD LANNOM
Date: 6/17 /14
Drawing#:A
Revlsions:
Rl: Change "Clips~ to white;
Made Permit Prints.
R2: Revlsed Logo box to aluminum face with
push thru copy.
R3: Change tag line to FCO acrylic (non-illum.)
ART TIME DATE REVISION NUMBER
1.50 6/17/14 PRELIMINARY PRINTS
1.00 7/22/14 .PERMIT PRl!'ITS-R1
o.so 7/29/14 PERMIT~ PRINTS-R2
0.50 7/30/14 PERMIT PRINTS-R3
5 1CJit!~i~PS
Providing electrical to the sign location ls the
responslbillty of others. San Diego Electric Sign, Inc.
Does NOT provide electrlcal to the slgn locatlon.
CUSTOMER APPROVAL OF DESIGNS:
Cllent Signature Date
Landlord Signature Date
PAGE 3 OF 6
D·
HAIRCUTS
G) "sPoRr: FRONT LIT CHANNEL LEITERs
FACE: .118" RED ACRYLIC
TRIMCAP: 3/4" BLACK
RETURNS: .040" ALUMINUM,
5" DEEP, BLACK FINISH
BACKS: .050" ALUMINUM
ILLUMINATION: RED LEDs
3
@"CLIPS: FRONT LIT CHANNEL LETTERS
FACE: .118''WHITE ACRYLIC
TRIMCAP: 3/4" "BLACK"
RETURNS: .040" ALUMINUM, 5" DEEP
BLACK FINISH
BACKS: .050" ALUMINUM
ILLUMINATION: WHITE LEDs
@ "HAIRCUTS": NON-ILLUMINATED TAGLINE
1/2" THICK ACRYLIC, PAINTED BLACK
PEG OFF WALL 1/2"
PHOTO OVERLAYS AND RENDERINGS ARE FOR PLACEMENT REFERENCE ONLY AND MAY NOT BE TO SCALE. PLEASE REFER TO THE PRODUCTION PAGE WITH MEASUREMENT
CALL OUTS FOR THE SPECIFIC SIZE/SCALE OF YOUR SIGN. NIGHTIIME VIEW SHOWN MAY NOT REFLECT REAL LIFE LIGHTING CONDITIONS.
THESE PRINTS AND THE DESIGNS HEREIN ARE THE PROPERTY DF SAN DIEGO ELECTRIC SIGN, INC., AND THE SIGNS OR DESIGNS HEREIN MAY NOT BE REPLICATED, DUPLICATED OR COPIED IN ANY MANNER, ANO MAY NOT BE USED FOR THE PURPOSE OF OBTAINING COMPETITOR
BIDS. UPON OBTAINING A FULLY EXECUTED DISPLAY PURCHASE AGREEMENT AND DEPOSIT, SAN DIEGO ELECTRIC SIGN, INC., MAY ELECT AT THEIR DISCRETION TO TRANSFER THE DESIGNS HEREIN TO THE CLIENT.
. " . ~an Diego Ele.cfcic .s'i.1!!::.
INSTALLATION• DESIGN• FABRICATION !J!JI CAUC1750379
Client: SPORT CLiPS
Job: FACE LIT CHANNEL !.;ETTERS
Address: 7180 AVENIDAENCINAS H102
CARLSBAD CA 92011
Salesperson: WARD LANNOM
Date: 6/17 /14
Drawing#: A
Revisions:
Rl: Change "Clips~ to white;
Made Permit Prints.
R2: Revised logo box to aluminum face with
push thru copy.
R3: Change tagline to FCO acrylic (non-illum.)
ART TIME DATE R,EVISION NUMBER
1.50 6/17/14 PRELIMINARY PRINTS
1.00 7/22/14. PERMITPRI.NTS-Ri
0.50 7/29/14 PERMITS PRINTS-R2
0.50 7/31)/14 PERMIT PRINTS-Rl
s,l?.t!~i~PS
Providing electrical to the sign location ls the
responsibillty of others. San Diego Electric Sign, Inc.
Does NOT provide electrlcal to the sign location.
CUSTOMER APPROVAL OF DESIGNS:
Client Signature Date
Landlord Signature Date
PAGE 4 OF 6
9' -3" O.A. LENGTH
D
11" 15"
I H A I R C u-TSt~-----==Is 1/4' 8 3/4'
EQ 5' -3" EQ
SQUARE FOOTA.GE CALCULATIONS
SIGN LABEL ALLOWABLE PROPOSED ALLOWABLE PROPOSED PROPOSED
(PRINTS) HEIGHT HEIGHT LENGTH LENGTH SQ.FOOTAGE
"SPORT CLIPS" N/A 15" N/A 9.25 LF t1r LETTERS
"HAIRCUTS" N/A 8.75~' N/A 5.25 LF 9.08 TAGLINE
TOTAL SQUARE FEET -/0~ f,-J
.6 SQUARE FEET OF S/GNAGE ALLOWED
PER LINEAL FOOT OF FRONTAGE./
TITLE 24
THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE
REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND I OR
OTHER APPLICABLE LOCAL CODES THIS INCLUDES PROPER GROUNDING AND
BONDING OF THE SIGN.
ALL WALL PENETRATIONS TO BE SEALED WITH UL LISTED SILICONE SEALANT.
FABRICATED WITH ALL U.L APPROVED COMPONENTS
PHOTO OVERLAYS AND RENDERINGS ARE FOR PLACEMENT REFERENCE ONLY AND MAY NOT BE TO SCALE. PLEASE REFER TO THE PRODUCTION PAGE WITH MEASUREMENT
CALL OUTS FOR THE SPECIFIC SIZE/SCALE OF YOUR SIGN. NIGHTIIME VIEW SHOWN MAY NOT REFLECT REAL LIFE LIGHTING CONDITIONS.
THESE PRINTS AND THE DESIGNS HEREIN ARE THE PROPERTY OF SAN DIEGO ELECTRIC SIGN, INC., AND THE SIGNS OR DESIGNS HEREIN MAY NOT BE REPLICATED, DUPLICATED OR COPIED IN ANY MANNER, AND MAY NOT BE USED FOR THE PURPOSE OF OBTAINING COMPETITOR
BIDS. UPON OBTAINING A FULLY EXECUTED DISPLAY PURCHASE AGREEMENT AND DEPOSIT, SAN DIEGO ELECTRIC SIGN, INC., MAY ELECT AT THEIR DISCRETION TO TRANSFER THE DESIGNS HEREIN TO THE CLIENT.
A /!/i San ~ego~,
f2.C tC ljl1."'
INSTALL.A: N·DESICiN·FABRICATION·
CA UC #750379
Client: SPORT CLIPS
Job: FACE LIT CHANNEL LETTERS
Address: 7180 AVENIDA ENCINAS H102
CARLSBAD CA 92011
Salesperson: WARD LANNOM
Date: 6/17/14
Dr'awing#:A
Revisions:
Rl: Change "Clips" to white;
Made Permit Prints.
R2: Revised logo box to aluminum face with
push thru copy.
R3: Change tagline to FCO acrylic (non-illum.)
ART:TIME DATE REVISION NUMBER
1.50 6/17/14 PRELIMINARY PRINTS
1.00 7/22/14 PERMIT PRINTS-RI
0.50 7/29/14 PERMITS.PRINTS-RZ
0.50 7/30/14 .PERMIT PRINTS-R3
Sl~t!~l~PS
Provldlng electrical to the slgn locatlon ls the
responslblllty of others. San Dlego Electric Slgn, Inc.
Does NOT provlde electrlcal to the slgn locatlon.
CUSTOMER APPROVAL OF DESIGNS:
Cllent Slgnature Date
Landlord Signature Date
PAGE 5 OF 6
'•
~ "', ~:, '", t: ~·;ii~:!-;:~',·', :i '""<. /"; ~-""-~"'
FRONT LIT. CflANN'EL LETTERS
5"
.040" ALUMINUM ---I--,
RETURNS
TRIM CAP____/
.177" ACRYLIC FACE--,,
.050" ALUMINUM
LETTER BACK __ --f!-,,-..-.--•
1/4"WEEP HOLES--~-
WALL: ---,------
MATERIAL: TBD
DEPTH: TBD
~--#10 x 3" LAGS INTO
EXPANSION SHIELDS
AS R~QUIRED.
MIN 3 PER LETTER
,---__ METAL ENCLOSURE
(RACEWAY)
U/L APPROVED
-ic----, ,.----DISCONNECT SWITCH
REMOTE CLASS 2
---POWER SUPPLY
INPUT:
AC 100-240 V 50/ 60Hz
OUTPUT: 12V
-----CONNECTION
TO POWER SUPPLY
@usTED
TITLE 24
THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE
REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND I OR
OTHER APPLICABLE LOCAL CODES THIS INCLUDES PROPER GROUNDING AND
BONDING OF THE SIGN.
ALL WALL PENETRATIONS TO BE SEALED WITH UL LISTED SILICONE SEALANT.
FABRICATED WITH ALL U.L APPROVED COMPONENTS
1/'t' ACRYLIC
,.......,.+--_THREADED . . '. . ~ :
. " • , ~ .j ..
: I .' ' ~ ' • '
STUDS INTO
BACK OF LITTERS .
MOUNTED
INTO WALL
WITH SILICONE
WALL
DEPTH:TBD
MATERIAL: TBD
ALL WALL PENETRATIONS TO BE SEALED WITH
SILICONE SEALANT.
PHOTO OVERLAYS AND RENDERINGS ARE FOR PLACEMENT REFERENCE ONLY AND MAY NOT BE TO SCALE. PLEASE REFER TO THE PRODUCTION PAGE WITH MEASUREMENT
CALL OUTS FOR THE SPECIFIC SIZE/SCALE OF YOUR SIGN. NIGHTIIME VIEW SHOWN MAY NOT REFLECT REAL LIFE LIGHTING CONDITIONS.
THESE PRINTS AND THE DESIGNS HEREIN ARE THE PROPERTY OF SAN DIEGO ELECTRIC SIGN, INC., AND THE SIGNS OR DESIGNS HEREIN MAY NOT BE REPLICATED, OUPLICATEO OR COPIEO IN ANY MANNER, AND MAY NOT BE USED FOR THE PURPOSE OF OBTAINING COMPETITOR
BIDS. UPON OBTAINING A FULLY EXECUTED DISPLAY PURCHASE AGREEMENT AND DEPOSIT, SAN DIEGO ELECTRIC SIGN. INC., MAY ELECT AT THEIR DISCRETION TO TRANSFER THE DESIGNS HEREIN TO THE CLIENT,
0
ia~iego l!!fl.cfcic .s'i1f!;
INSTALLATION· DESIGN· FABRICATION t::J CALIC"750379
Client: SPORT CLIPS
Job: FACE LIT CHANNEL LETTERS
Address: 7180 AVENIDA ENCINAS H102
CARLSBAD CA 92011
Salesperson: WARD LANNOM
Date: 6/17 /14
Drawing#: A
Revisions:
Rl: Change uClips~ to white;
Made Permit Prints.
R2: Revised logo box to aluminum face with
push thru copy.
R3: Change tag line to FCO acrylic (non-illum.)
ART TIME DATE REVISION NUMBER
1.50 6/17/14 PRELIMINARY PRINTS
1.00 7/22/1~ PERMIT PRINTS-R1
0,50 7/29/14 PERMITS PRINTS·R2
0,50 , 7/30/14 PERMIT PRINTS·R3
5 1C?it!~l~P&
Provlding electrlcal to the sign location ls the
responsiblllty of others. San Diego Electric Sign, Inc.
Does NOT provide electrlcal to the sign location.
CUSTOMER APPROVAL OF DESIGNS:
Cllent Signature Date
Landlord Signature Date