HomeMy WebLinkAboutPS 15-30; MICHAEL KORS; Sign Permits/Programs (PS)( City of
Carlsbad
REVIEW FOR
SIGN PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
PLANNINGA?=1c~:ps I lf>-30
REC'D BY \...:_..._ _ __._~~Q~~'-=__..,._,__ ______ _
SIGNFEE f$C'...ci DATE ;3-~-Li
SIGN PROGRAM F ________ _
RECEIPT NO. ___________ _
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and
sign elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4 . Distance to the property line(s) for all proposed freestanding sign(s).
5 . Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
Name of Project: _M_ic_ha_el_K_or_s ______________________ _
Address of Project: _56_2_0 _Pa_seo_D_el_N_ort_e ___________________ _
Assessor Parcel Number: _21_1_-0_22_-22_-00 ____________________ _
Related Planning Case Number(S): ___________________ _
TYPE OF DEVELOPMENT:
(a) Residential (d) Hotel/Motel (g) Theater
(b) Commercial (e) Service Station (h) Gov't/Church/School
0) Produce Stand
(k) Nursery
(c) Office/Industrial (f) Prof. Care (i ) Public Park (I) P-U/OS Zone
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesD NoD
Specific Plan Number ____ _
VILLAGE REVIEW AREA (If yes, please complete information on page 3) YesB
SOUTH CARLSBAD COASTAL REVIEW AREA Yes
SIGN ORDINANCE: Yes D NoD
COASTALZONE: YesD NoD
P-11 Page 1 of 4
NoD
NoD
Rev. 10/13
,·
EXISTING SIGNS:
. TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument '
Wall
Suspended/Projecting
Directional'
Canopy ,
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes O No 0
PROPOSED PERMANENT SIGNS:
Date 3/3/15
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER SIGN SIGN SIGN
ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT
Pole-
Monument**
Wall 1 44 .. 5 2'
Suspended/Projecting 1 6 2'
Dlrectlonal
Canopy
Freestanding-
{Project Identity)
Dlgltal Display
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM I PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN · SIGN AREA SIGN SIGN
ALLOWED AREA . HEIGHT HEIGHT
Construction**
For Sale** ,\
Banner
Interim :
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility Issues. Additional information must supplement
this application showing how the proposed slgnage wlll not encroach Into the public right-
of-way or present a traffic tlazard. Page 3 of 4 Illustrates an example .for what would be
· required for such proposed signs.
P-11 Page2 of 4 Rev. 10/13
SITE PLAN REQUIREMENT' FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which wlll not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I I I
PIL I Sjpt; ~
SbUlr bmldiq/s
I I
I
~---l I
Shaw setbacb froa al carbs ---
I I I ' I I I . Sha,r all. prop mt)' lines I
PIL ' I
:/ I
~Hne i
----------~---
SJpt Vhibflity I
Street N11J1111(s) (i) I
I Nortla
21.41.080 Sign design standards
RelatJonshlp to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA ·
Total Bulldlng Square Footage: ________ sq. ft.
Total Building Street Frontage: _!:1-(o linear ft.
Total Signage Allowance: =r3., (p sq. ft.
Existing Signage (sq. ft.}: J2J: sq. ft.
Remaining Sign Allowance at Present: ~ sq. ft.
Proposed Signage (sq. ft.}: ~4:_,S sq. ft.
Remaining Sign Allowance After Proposed Sign: ~ L sq. ft.
VILLAGE REVIEW AREA
, Total Signable Area: ________ sq. ft.
' Total Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3 of4 Rev. 10/13
PROPERTY OWNER APPLICANT
NAME (PRINT OR TYPE) NAME (PRINT OR TYPE)
Simon Premium Outlets Kristina Bernal/Matthews Signs Inc
MAILING ADDRESS MAILING ADDRESS
5620 Paseo Del Norte #100 550 W. 6th Ave
CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE
Carlsbad CA 92008 (760)804-9044 Escondido, CA 92025 8'Sd
I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE
AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE
IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT
MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE.
S,Pf M-\-ar X\f'C) 3/3/15 \~OJ P.A ,A _J___ 3/3/15
SIGNATURE DATE ,NATURE s1a DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: •!• In right-of-way •!• In visibility triang le at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner:~ , SJ?~ Date: 3-3 -/ :;;'
P-11 Page 4 of 4 Rev. 10/13
Date: January 14, 2015
To: Patti Shore
Company: Assured Signs
<X>
CARLSBAD
PREMIUM OUTLETS.
A SIMON CEN TER
SIGN APPROVAL
From: Judy Walton
Senior Tenant Sign Manager
Premium Outlets
Email: pattishore@bellsouth.net iwalton@simon.com
Tenant:
Suite#
CC:
Michael Kors
B115
Carlsbad Premium Outlets
<X>
SIMON
PREM IUM OUTI.ET S
ATTACHED IS THE LANDLORD'S APPROVAL AS NOTED OF THE SIGN DRAWINGS AND
ELEVATION FOR THE STOREFRONT & BLADE SIGNS FOR "MICHAEL KORS", SUITE #B115,
AT CARLSBAD PREMIUM OUTLETS. Contractor/Tenant must verify that blade sign
bracket is existing and field verify mounting height with onsite Center management of
all signage included in this approval.
SIGN INSTALLER MUST MAKE APPOINTMENT WITH ONSITE CENTER MANAGER 48 HOURS
BEFORE ARRIVING TO INST ALL SIGN TO CONFIRM THE ACTUAL LOCATION OF ALL SIGNS
ON BUILDING PRIOR TO INSTALLATION.
ALL PENETRATIONS MUST BE SEALED FROM BOTH THE OUTSIDE WALL AND INSIDE WALL
TO PREVENT WATER INTRUSION .
SIGN CONTRACTOR IS REQUIRED BY LANDLORD TO REVIEW ONSITE CONDITIONS AND
OBTAIN PERMIT PRIOR TO FABRICATION OF TENANT'S SIGN. PLEASE CONTACT ONSITE
CENTER MANAGEMENT FOR ALL PERMIT AND COi INFORMATION.
SIGN CONTRACTOR IS REQUIRED TO PROVIDE ONSITE CENTER MANAGEMENT WITH
REQUIRED COi AND COPY OF THE SIGN PERMIT PRIOR TO INSTALLATION OF SIGN.
Landlord's approval concludes that Tenant has met all Landlord's sign requirements, however, Tenant bears
full responsibility, financial and otherwise, for adhering to any regulatory, code and permit requirement s as
they relate to Tenant 's signage.
5620 Paseo del Norte #JOO, Carlsbad, CA 92008 • (760) 804-9044
-
MICHAEL KORS
Carlsbad Premium Outlets
5260 Paseo del Norte
Space B115
Carlsbad,CA 92008
Approved As Noted -Upon receipt of pennlt rrom city/county
fabncabon may be undertaken. Signs must confonn to all Landlord
comments on these drawmgs.
• Installation of sign to be coordinated with Center Management not
to disrupt buslness,
• Must pl'OVlde Center Management with copy of penni & insurance
poor to lnst.labon & verify prq,er sign placement prior to instil.
• Center Management must s,gn off on sign installation when complete
<X>
S IMON
talltEMtUM OUTL..&Ta
By WaltonJ at 11:55:23 AM, 1/14/2015
MICHAEL ~ORS
SPACE Bl 15
,1
H ~ .....
As s ured S l &n s L LC __ ,___Q. ...
Wlt ..... f\Ma •11 ••• as,,
APPROVED
SBO 01.05.15
--~ ____ __,
LED !I_LUfdl!JATEO REI/ERSE CHAf\/NEL !_ETTERS .. WINDOW VINYL
i-22'~ ttr
sw-1-
A11ered Sia•• LLC
£MICHAEL KORS I~ MICHAEL K0RS
01AHHELl.£TTERS:
24" TM.&. X a t1Z" THla( LB) IU.UMNATED R£Vl!RIE QtANM1!L LETTERS fWNTE0 PMS ll.ACfC 4C CHOCOLATE IROWN. TOTAL. PROPOSED SQFT.• 4U
UUMtNAlEDwmt WHrM LED'S.
011111111111,......~ ........ ~ ~-r STANDOFFS PAIN'IE> TO MATCH FASCIA.
QTY. t SET
===--
MICHAEL KO
---==-
===-
..,_ ____ . ___ .....,
s~~;m~~~I!: t·i~'W!~
~VIIM.10-APPUED2ND SURFACE.
0TY.28ETII
,om PA0f'08ED 80FT. PER 8£T• .9
J
: I I :.. 1, l ~·· ' I r. • :.. L --ooo ~------..... -
Approved As Noted -Upon receipt of permk from city/county
fabrication may be undertallen. Signs musl conform to all Landlord
comments on these drawings.
Installation of sign to be coordinated with Center Management not
to disrupt business
Must provide Center Management with copy of permit & insurance
prior to lnstallabon & verify proper sign placement prior to Install.
Center Management must sign off on sign Installation when complete
<X>
SIMON
~ltCMtU"4 O UTl,..CT.
By WaltonJ at 11:55:08 AM, 1/14/2015
LED ILLUMINATED REVERSE CHANNEL LETTERS b TYPICAL CROSS SECTION
3112" 2" •
NT8
SPECIFICATIONS :
A REVERSE CHANNEL LETTERS FACES & RETURNS PAINTED PMS BLACK 4C CHOCOLATE BROWN
(INTERIOR PAINTED WHITE FOR REFLECTIVITY.
B. MOUNT LETTERS TO EXISTING WALL WITH 114" X 6" TOGGLE BOLTS & 2· SPACERS
PAINTED TO MATCH
C GROUND WIRE AS PER UL879 SECTION 4.18 Cl.ASS 2 LEO COMPONENTS.
D. BRIGHT WHITE LE.0. MODULES FOR ILLUMINATION
E. 3118" CLEAR LEXAN BACKS
F EXISTING E.F.1.S OVER METAL FRAME WALL (TYPICAL)
G. UL-1/2"' DIAMETER SEALTITE THROUGH WAU TO POWER SUPPLY/ JUNCTION BOX
H. COMPACT 60(MA) LOW VOLT.o.GE POWER SUPPLY IN WEATHER PROTECTIVE BOX
AS NEEDED.
I. JUNCTION BOX PER N E.C. 600-21 WITH 20 AMP. DISCONNECT SWITCH
PER N.E.C. 380-14" PER CIRCUIT PER 000-8 BY OTHERS.
J. CUSTOMER PROVIDED PRIMARY ELECTRICAL TO BE WITHIN SIX FEET OF SIGN
FOR PROPER HOOK UP.
K UL TOGGLE STYLE DISCONNECT SWITCH WITH RUBBER BOOT MOUNTED TO
(1)LETTER.
TOGGLE BOLT/BUTTERFLY ANCHOR
WITH SPACER
aECTRlCAL NOTES (LE.D.):
AU ELECTRICAL COMPONENTS WlU BE UL LISTED ANO APPROVED
AS PER 2008 NEC 600 ••• 600.3 & DESIGNED TO UL #48 PER F.S. 553-19.
AU SIGNS ARE TO BE GROUNDED ANO BONDED PER NEC 600.7 ANO 250.
MICHAEL KO RS
.. --
-
-
AU WIRING INSIDE LETTERS WILL BE 12V-CLASS 2 18GA I LOW VOLTAGE WIRING.
AU PRIMARY WIRING WILL BE #12 TWHN HIGH TENSION 1'J3 PER NEC 600.12(C).
THESE PLANS COMPLY WITH F8C 4505-21. ..----------'-'------'-
JUNCTION BOX INSTALi.ED BY CUSTOMER'S ELECTRICAL CONTRAC1
TO WITHIN 6' OF SIGN LOCATION PER NEC 2008.
~,,,. ...... _....,..,..._.,~,,_~ ~,.,.,.-~.,..,.._.co,ito,ffi ... ~
CCll'l'IJIWIIOII .... ....,.. •.......... o1..,..1o .. ~a1M--.c-...,......_._ ------------------------------------------------------1 . ====='-'=°' . c...:~-·--..., ............ _,,_ <X>
SIM ON ----·~· ---
By WaltonJ at 11:54:44 AM, 1/14/2015
••
Verify and use preferred banging method at center.
-1~-
.,.,., I --
-
ApprtNed M Noted-Upon r9C8lpt of~ from ~county
fabrication may 1111 undertabn. ·Signs must contonn to an Landlord c:anmenta on tliese drav.-klga.
-
• lnstallatlon of sign tQ be COOldmded w!lh Center Mallllg8ITl8llt not
to dlaupt tiullnasa.
• Must provide Cenler'Management with copy of pennR & 11W11111lCe
prior to lnstaBlltlan & vartry proper sign placemert prior to lnstal.
• Center Management must slgii off on sign lnltalailon when complete. <><>
SIMON
P'RCMIUM OUTLrrll
By WaltonJ at 11:54:25 AM, 1/14/2015
81.ADE818N
24" TM.I. X 38" ~ X 2" THICK ALUMINUM ~ DOUBLE 8IDeD lllAOK SION.
-100t----,
r-
' I
I
L_
--10------1,-....
MINTED WHl'Ta Wl1lf COPY, LOGO CHARM MD l!IORD8R 1¥.1m!D PMS Bl.Aa( 4C CKOCOlATE BROWN.
QTY.1
i,I. !
a a i I
PROP081!DIQ PT.•e
A11•••il II&•• LLC
MICHAEL IC0RS
c.lllledl'lllla!IIOIIIIIII
......... Nalllt
lpamlt111
Cldlllld,CA am -
--DOD ..... ___._._,. .....
L"':'. a,-:-:i.•
• I ~i
MICHAEL KORS
[;-SJIGN Pm~-vm 1\o. PB I ~==s-s.Y--:) -'·]
!J --------~---~ '
; bi. :COVRuBY I DATE i I
F'_•,IJ)m·J£~~--~ . 3 0t.Cl.1 ~-
?ro?osed: ~,') NtW ~er 0\-,\\\)rn,ratevi
~ve.rse c"'™'ne1 \e-\te r~
~~ CS) ~~~f\ \J&\f\9
e,"'' ~i\~ t>m~~.
Carlsbad Premium Outlets
&?N: 2.\ \-011.-22-DO
5(o1.0 Paseo del Norte
Space 8115
Carlsbad, CA 92008
Assured Signs LLC
696Wl'mmCI.SW llwo8-:ll,Fl30882
772.988.2900
LED ILLUMINATED REVERSE CHANNEL LETTERS I WINDOW VINYL
22'-3 112·
31/2" !. • 1 I
TMICHAEL KORS I
CHANNEL LETTERS:
24• TALL X 3 112• THICK LEO ILLUMINATED REVERSE CHANNEL LETTERS PAINTED PMS BLACK 4C CHOCOLATE BROWN. TOTAL PROPOSED SQFT.: 44.5
ILLUMINATED WITH WHITE LEO'S.
2' STANDOFFS PAINTED TO MATCH FASCIA.
QTY.1 SET
l\lD'-0 '1 -----
I 39'
3 1/2" 1i,.~! . '.~ i<el(L .(,:_ ~I
SPECJELCATIONS:
WHITE WINDOW VINYL TO BE APPLIED 2ND SURFACE.
QTY.2SETS
TOTAL PROPOSED SQFT. PER SET: .9
. -m··-, ~-tl·---_..,.__ .
' ' '
'
,_,
~1
Assu r ed Stans LLC
MICHAEL KORS
...... _,; t) .. !'
C8l1sbed Premium outlets
5260 Pueo del Norte
SpeeeB115
Car1abad.CA 92008
__ Rep.JPM:Polll
o.to; IZ-1"-1•
CLIENT APPROVAL -._,DOD
l'UAleflEIIIIWNC>QQ'l""°"lO-...:i
AOOL. INFO _._ .. ,_
REY. DATE
LED ILLUMINATED REVERSE CHANNEL LETTERS
TYPICAL CROSS SECTION
A.
~ (31/2;;,, f 9 ·· ) \......J 8 .
AJ C.
D.
E. Bl F.
J. l:=::::tt: I • I I I £1
G.
H.
I.
J.
K.
NTS
SPECIFICATIONS :
REVERSE CHANNEL LETTERS FACES & RETURNS PAINTED PMS BLACK 4C CHOCOLATE BROWN.
ONTERIOR PAINTED WHITE FOR REFLECTIVITY.
MOUNT LETTERS TO EXISTING WALL WITH 1/4" X 6" TOGGLE BOLTS & 2" SPACERS
PAINTED TO MATCH.
GROUND WIRE AS PER UL879 SECTION 4.18 CLASS 2 LED COMPONENTS.
BRIGHT WHITE L.E.D. MODULES FOR ILLUMINATION
3/16" CLEAR LEXAN BACKS
EXISTING E.F.I.S. OVER METAL FRAME WALL (TYPICAL)
UL-1/2" DIAMETER SEALTITE THROUGH WALL TO POWER SUPPLY/ JUNCTION BOX.
COMPACT 60{MA) LOW VOLTAGE POWER SUPPLY IN WEATHER PROTECTIVE BOX
AS NEEDED.
JUNCTION BOX PER N.E.C. 600-21 WITH 20 AMP. DISCONNECT SWITCH
PER N.E.C. 360-14A PER CIRCUIT PER 600-8 BY OTHERS.
CUSTOMER PROVIDED PRIMARY ELECTRICAL TO BE WITHIN SIX FEET OF SIGN
FOR PROPER HOOK UP.
UL TOGGLE STYLE DISCONNECT SWITCH WITH RUBBER BOOT MOUNTED TO
(1) LETTER.
TOGGLE BOLT/BUTTERFLY ANCHOR
WITH SPACER
ELECTRICAL NOTES (L.E.D.):
LED MODULE DETAIL: N.T.S.
ALL ELECTRICAL COMPONENTS WILL BE UL LISTED AND APPROVED
AS PER 2008 NEC 600.4, 600.3 & DESIGNED TO UL #48 PER F.S. 553-19.
ALL SIGNS ARE TO BE GROUNDED AND BONDED PER NEC 600.7 AND 250.
ALL WIRING INSIDE LETTERS WILL BE 12V -CLASS 2 18GA / LOW VOLTAGE WIRING.
ALL PRIMARY WIRING WILL BE #12 TWHN HIGH TENSION AS PER NEC 600.12(C).
THESE PLANS COMPLY WITH FBC 4505-21.
JUNCTION BOX INSTALLED BY CUSTOMER'S ELECTRICAL CONTRACTOR
TO WITHIN 6' OF SIGN LOCATION PER NEC 2008.
A•1ured S ign• LLC
MICHAEL KORS
:l::Fl ~:I-·'
ca.111.bed Premkxn OuUeta
5260 Paseodel None
$pece8115
C.~11.bed,CA 92008
Dito: 12-14-14
CL I ENT APPROVAL
Nlmo:
Doto: DOD
l'UARMWWNCiDIJlflNOIIITO____,
ADO L . INF 0
REVISION
REV. DATE
l'·l'W
,...,.
BLADE SIGN
~~----+--'*'N)MACll'ff'IO\UOUI.NQ.OIO \IWffM~ttOUGMIIOUIIC8
-,~--2· ~,
fl" I --r---t-m!iHillt"~~.,ICAOI"°" lOtfP.-.n!O.,._ '1"1Nll7.fJ'WX1"0MNi4 oorJ,l.000N0"*8IOW:1~~,~ IOw.JCN"""' < •DOUllltlOl'O .... , Mllllllf*'nro:c
ur·fHCll.....-... .... "°°°-~•tOl:Ul
24• TALL X 36" WIDE X 2• THICK ALUMINUM NON-ILLUMINATED DOUBLE SIDED BLADE SIGN.
EXISIJOG $10fflll0NI
TOREMil" ----+-~
;
g
~Ii 1i\ a
I
PAINTED WHITE WITH COPY, LOGO CHARM ANO BORDER PAINTED PMS BLACK 4C CHOCOLATE BROWN.
QTY.1
!'.139F_>OSEO S9 _ FT. = 6
~ j
§l §l
!?lh I ~ I~ I a a I I
• Assured Signs LLC
MICHAEL KORS
Carlsbad Premium Outlets
5260 Paseo del Norte
Space 8115
Carlsbad.CA 92003
~_,_Sq,
0..lgnor.08
SMs R11>.IPM: Paul
Dote: 12"1'-14
-
o ... , o ,o ,o
Pl.EASE REVIEW NfO °'TE PN0R TO SICiHtfQ
REV. DATE