Loading...
HomeMy WebLinkAboutPS 15-90; RITE AID; Sign Permits/Programs (PS)' ._: , Cci~of Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING APP~C~ pc;5 ! '5-9-0 REC'D BY Chns ~on DATE 9 -t Q--t<S SIGN FEE _1£_EQ: ______________ _ SIGN PROGRAM FEE ________ _ RECEIPT NO. ___________ _ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations ~ntainlng the following information: 1 . Nortf:1 arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the prope,rty line(s) for all proposed freestanding slgn(s). 5. Provide an elevatloa for all proposed slgn(s) which specifies the following: A. Dimensions and area for all existing and proposed slgn(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST ·SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. lfrGT,,," mus s ,hw,me..-t .m. Average processing time: 2 weeks . \'~ Name of Project .....:.i' tv~_-...J-L....J.!....4-~....;_L,Z..=..;::=--__,,.-------------- Address of Project • n.~ ~ Assessor Parcel Number. ______________________ _ Related Planning Case Number(S): __________________ _ TYPE OF DEVELOPMENT: Residential (d) Hotel/Motel (g) Theater . Commercial (e) Service Station (h) Gov't/Church/School 0) Produce Stand (k) Nursery Office/Industrial (f) Prof. Care (I) Public Park (I) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesD NoO Specific Plan Number· ____ _ VILLAGE REVIEW AREA (If yes, please complete Information on page 3J Yes D SOlJTH CARLSBAD COASTAL REVIEW AREA Yes 0 NoD· NoO SIGN ORDINANCE: Yes O No 0 COASTAL ZONE: YesD NoD P-11 Page 1 of 4 Rev. 10/13 . EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument / ,. Wall I 50 '-4 -,, 6t) LI suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** Wall \ l 35.53 3o '' Sus pended/Projecting Directional Canopy Freestanding- (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Cor1struction** For Sale** Banner lntertm **Prior to approval, all proposed pole, monument, and freestanding signs must be revt8W'ed for potentlaJ sight distance and vlaiblllty Issues. Addltlonal Information must supplement this appllcatlon showing how the proposed slgraage will not encroach Into the publlc Hght- of-\\#ay or present a traffic hazard. Page 3 of 4 illustrates an example for what would be r&ql..llred for such proposed signs. P·11 Page2 of4 Rev. 10'13 ;.,,.. . SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the Information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential Issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be requlred'for on-site Inspection. I I I I P/L ;-:: .. ---Slunr lnaildlngf 1 ' I ',---l Shaw 1etbadcs from all ctds i / I Shaw all property lines I PfL : / I :/ I cmb line i ----------~--- SiptVlsihilitJ' I Stn,et Name(•) (i) I I Nertla 21.41.080 Sign design standards Relatlonshlp to Streets: Signs shall be designed and located so as not to interfere with the unobstructed. clear view of the publlc right-of-way and nearby traffic regulatory signs of any pedestrian, bicycllst or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that It Impairs the sight distance requirements at any public or private street Intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Bullding Square Footage: __________ sq. ft. Total Building Street Frontage: Lto ~ linear ft. Total Slgnage Allowance: sq. ft. Existing Signage (sq. ft.): <o(Q. 5] sq. tt{q .S(o st f\\~ Remaining Sign Allowance at Present: sq. ft. ()~) Proposed Signage (sq. ft.): sq. ft. Remalning Sign Allowance After Proposed Sign: sq. ft. VIL LAGE REVIEW AREA Total Slgnable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: Inches P-11 Page 3 of 4 Rev. 10/13 . ..-. ( . ( UC CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE PLANNER CHECK LIST: 1. Field check by planner. ' 2. Within maximum length, area. APPLICANT NAME PRINT OR TYPE MAILING ADORE CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO TH BEST OF MY KNOWLEDGE. DATE 3. Style consistent with Sign Program and/or Specific Plan criteria, If applicable. 4. Location: +:. In right-of-way •> In visibility triangle at comer 5. Pole and monument signs to be checked by Transportation Engineering, for visibility lssu es. 6. When approved route copy to Data Entry APPROVED: Planner:~~ Date~C/,-/0-lS P-11 Page4 of 4 Rev. 10/13 Jeremy Shirey From: Sent: To: Subject: Attachments: Good afternoon Jeremy, Preston Robins [probins@prinvestments.com) Thursday, September 03, 2015 3:02 PM Jeremy Shirey RE: Rite Aid #5622 Carlsbad exterior signage Rite Aid New Sign Approval Sep 2015.pdf Per your request, please find attached the signed requested documents. Preston Robins Director Robins Carlsbad, LLC NEW EMAIL ADDRESS probins@prinvestments.com P. Robins PR lnvestmenls 16745 Bajio Rd . Encino, CA 91436 (8 18) 990-0206 (818) 990-0705 (Fax) probins@prinvestments.com This e-mail may contain privileged and confidential Information and is intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient or the employee or the agent responsible to deliver it to the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is prohibited. If you have received this e-mail In error, please notify us by responding to this e-mail and destroy the related message. From: Jeremy Shirey [mailto:jshirey@signartinc.com] Sent: Wednesday, September 02, 2015 12:04 PM To: Preston Robins Subject: Rite Aid #5622 Carlsbad exterior signage Preston, Attached is Rite Aid's exterior signage proposal for your review. If approved, please stamp and/or sign each page so we can begin the permitting process through the city. Please feel free to contact me with any questions or concerns; we are on Eastern time. Appreciate your time, Jeremy Shirey Project Manager SignArt, Inc. 269-216-5958 direct line Si t ·h~ii:ll R·ITE Al D .E!l•J J . Store #05622 7100 Avenida Encinas, Carlsbad, CA, 92011 PROPOSAL ~ l:~!NJ.-,r, "/P;!b,,,._ '~b ~i,,a.. ~,, A!~8~ ~~~ SignArt Inc., 5757 E. Cork Street, Kalamazoo, Ml 49048 269.381 .3012 signartinc.com Si t SITE PLAN Site Plan Scale, NTS EB Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 , '-----L Lead #1085 n,,.;..,....,..~.--..~laryour-inmnnodlon~pion,,ed lor)Ollbys;,,M. 111,-.,1,e~ c:apiedo,11,chl,il•l'ln~o/Sf""'-C 201S CA,n562h BJ .. 'il"JL 9-2-15 Approved for~ ~ LY4/ yJ~ /,~ <..._ By:{. ~ ::..>-2 Date: 'J • 7-t >- / Si t ELEVATION Sign #2 Slgn#l Sign #3 Existing Elevation Scale: NTS P~ed Elevation Scale: NTS Nole: Sign #1 to be mounled centered on previous 'ttile A.-1 sign location. Rite Aid #05622 -7100 Avenida Encinas, avtfl>a4, lead #1085 BJ ~JI., 9-2-15 Approved fo(: y -, , ., ,. , nr...., -«_ !J "'-. ......._ C 2015 CA,r.a.562:u-Date:9-.J-I .) Si »\rt ELEVATION Existing Elevation Scale:NTS Pro~ Elevation Scale: NTS Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 / / Lead #1085 lhl> Is an oog;n. unpubliohed c1,aw1,._ wbmhled ro, )'Ollf use in a>MDClion~ ~1,.. pl>nnold for )OU by Sl(pwt. It• noi IO be reproduced. mpied o, exhibllad ~-pennlMion ol 54rM-C 201 S CA,raS622a BJ .ffilL 9-2-15 Approved for: t>,,._. C.,,iC-(lf;~ LL<:........ By:, ~ Date:q'-J -, r 7 Si t I 14'-4¼" I s· 9¼" H 7'-6" I I 6'-1" I I AID Sign #1 -Illuminated Channel letters Scale: ¼• = 1 •-0• 'lfTE AID' l.dkn -Flat dear polycarbonate fac.ed, U.L. labeled, aluminum channel letters with 1• blue trim cap and s• deep relums painted CripCard semi-gloss to match #2870 blue. Faces to have dual blue color fifm applied to first surface, and diffuser applied to second surface. Insides of letters to be painted with AKZO bright white reflective finish. Letters are illuminated using white LEDs powered by low voltage power supplies. RITE AID Night View Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 Olis Is an orig!NI unpubli,hed drawins, wbmilud for)OIW use In BJ ..'iJ!.IL 9-2-15 Approved for: cv v 1 07 , LR._,,,....,, '7P II .... '- SIGN #1 Lead #1085 0 201S CA,ra562~ Datf'~9' -j -' ,- Si t 10'-3" _________ ..J rr= 1 '-6° 1 '-0" ~ Sign #2 -Replacement Face For Existing Bullet Scale :¼ • • 11-0• .080 Aluminum face painted to malCh #2870 blue, precision routed and backed wilh flat white polycarbonate. Note: American Sign Company 10'-3" r,= 1°-6"9¼" L= GNC LIVE WELL Sign #3 -Replacement Face For Existing Bullet Scale:¼• = 1°-0• .080 Aluminum face ~nted to match #2870 blue, precision routed and baclced with flat white polycarbonate. Note: American Sign ComjWly Rite Aid #05622 -7100 Avenida Encinas, .. plinned for )OU Ii,-~ 1111 not ID be~ CIDpied Of BJ .ftJls 9-2-15 Approved for: fo t!z ,~s W &-.S 44"'i). LLL Sl(~NS #2 & #J Lead #1085 ~ C 201S CA,n5622a.,-- Oate: ~ -J-: / "> Si t SIGN#~ 4'-6¼"'----------' I .r. 2'·1½" J_ ~ Sign #4 -Replacement Face for Exi5!ingSingle-Faced Illuminated Monument Sign Scale:¼• = 1•-0• Existing 'RITE AID' face to be a.it out and replaced with new precisjon routed .100 aluminum face painted semi-gloss to match PMS Mp06997 Perfino Bianco. Face to be backed with flat white polycarbonate OYerlaid with #2870 blue pressure sensitive vinyl. Face to be mounted to monument with countersunk screws painted to match. Ni~tView Rite Aid #05622 -7100 Avenida Encinas~ BJ .. 'it!"JL 9-2-15 Approved for: r -., 'C/ -T A L> ~ « IJ , --i..;,__ C 201S Date: Scale: NTS Lead #108S CA,ra5622a 7--.l-J ') ... Si l'\rt Illuminated Channel letter Detail Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 9201, CHANNEL LETTER DETAIL (D .040 Numinum ~ sldes painted QipC,ard semi-gloss to match #2870 blue. @ 1' trim cap with #8 x ¼" hex head screws as needed. 0 Flat white polycarbonate faces. 0 G.E. Tetra MAX LED system. © Low voltage wiring from power supply. © Pre-dn1lecrlow voltage electrical hole with¼' plastic grommet. (v W Weep holes at low points of letters with lntemal light baffle, @ .050 Aluminum letter back. Letter sides and backs stitched together and continuously slliconed. ® Bulldkig facade; exact construction to be verified. @ Vertical stuQ by others. @ 20 An:ip toggle dJsconnect (actual location to be on end of raceway, shown on top for drawing purposes only). @ 41 x 6" x 18" JIC box. @ Low voltage (12 volts) G.E. #GEPS12-60 LED power suppRes (120 volt circuit required). @ Secondary wiring low voltage connection to LED's with #054007-06128 ScotchJok connectors. @) Ground wire permanently fixed to power supply box. @ ½" Sealtite tonnector. @ UL listed Beiden #94091PR18 AWGwlre. @ ¼" Sealtlte conduit. @) #12 THHN electrical primaiy wiring. White -Neutral Black-Feed Green -Ground @ Letter.; mounted to facade with ¼' stainless steel threaded rod, washers and nuts as needed. Exact fastener to vary with different facade/bullding construction. Note: All penetrations to be sealed with 3M #1000 NS Fite Barrier, water tight, non-slump sillcone sealant to meet NEC #300.21, A.STM #E814, UL #1479 & UL #2079 standards. Building dimensions and construction of facade to be verified by slgn Installer prior to installation of signs. Scale: 2"' = 1 '-0" Lead#1085 • 1hh II an original w,pul,liih,od inwlng. IUbmlam IDr yoUI'-in COOlledl<,,, will,-~ planned lo< YQII by SlgnM. It Is ootlD be~ cupied c,r > C201 S CA,ra5622a ·.-- BJ ~ 9-2-15 Approved for: J )/le$ '31 c£ l-S' '*'.~,) ~ · _ Date: <;? -} -["') / :.. I Si t rlillII RITE AID l~J Store #05622 7100 Avenida Encinas, Carlsbad, CA, 92011 PROPOSAL ••••I • C •. ,;_.. "'· l~:::9~ ~----, C}u-1.s_Se~ 9' -( 0-t i SignArt Inc., 5757 E. Cork Street, Kalamazoo, Ml 49048 269.381.3012 signartinc.com Si t SITE PLAN Site Plan Scale: NTS EB Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 lead #1085 fhi, 6 an original unfl'Jbll>hed dro1Wi~ >Ubmrttl'd In, your u;e In tonnedlon ..;,h • project bring planned (o, )W by S.pv,n II i> no< to boo reproduaod, oop;..t., .,.hit,,1«1 In •n) r,,>hion wl1hou1 wrim,n p<'rmiioloo nl SigM,t C201 S CA,ra5622a BJ ~J!itL 9-2-15 Approved for: _______________ _ By: _____ _ __ Date: Si t ELEVATION f~Ot~ ~}n11 ,~~Of\~ I CPO I cot.a..! f yo v)i· J-<L I-=:;flt.tx i '5 ~I ~/f •aa-,.1rrn-4µ;t4;J;t4n Existing_ Elevation Scale: NTS Proe_osed Elevation Scale: NTS Note: Sign #1 to be mounted centered on previous 'Rite Aid' sign location. Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 Lead #1085 lho IS ;)f'I Of1R1n.llunput.1ft),h('d d,.lwtng. whmtUed fo.-),>ut US(' In (onnc.'Qion wlih.t IJ'Hl1t"t1 bt.•1ngpl.mo1•d k>f .,._'° b)· 5,1giAt1, 11,s nc,a loben-pmdu«d. t-cJt}l(-d c• c,,,h~rl-d tl'I •nv l.nhlur1 w,:1hoo1 ":nu,•n pcnmNln ol S.SJlA,rl ©2015 Date: CA,ra5622a BJ .!ir;Us 9-2-1 5 Approved for: By: Si t ELEVATION Existing_ Elevation Scale: NTS Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 lead #1085 This Is on origlnol unpublishfd d<ilWlng. wbml11,d (o, )'O<K use In coon<abi wilh • P"'i«t bolog pl,lrttd (o, )'OU by Sii,,An II I, nol 10 bo , __ , o,p;.d ot .,.h,blu,'(f in •ny fashion ,-,lhc>ol writ.,,, ponnl,..,., ol ~ C2015 CA,ra5622a BJ ..'ifills 9-2-15 Approved for: ______________ _ By: _______ _ Date: ____ _ Si t SIGN #1 5• H I 14'-4~~.-I .~7'-6'__,__ 6'-1"----1· ~ I 2'-6' _L AID Scale: ¼" = 1 '-0" Si[n #1 -Illuminated Channel Letters 'RITE AID' letters -Flat dear polyc.arbonate faced, U.L. labeled, aluminum channel letters with 1' blue trim cap and 5' deep returns painted GripGard semi-gloss 10 match #2870 blue. Faces to have dual blue color film applied to first surface, and diffuser applied to second surface. Insides of letters lo be painted with AKZO bright white reflective finish. Letters are illuminated using white LEDs powered by low vohage power supplies. 35. 83 ¢ RITE AID Night View Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 lead #1085 lhi> 6 an Ofit:in.11 unpubll!dw.-d dr-.w.·,r1g. submiued ror )'OUt use in c:onneoion wilh a pro;e,c:1 bt-ing pl.lnncd IOJ you by S1W"',rt. II fl OOl 10 b(, fepl'Oduced. C1>f"ed or ahibited in .my t.nhioo w.lhou1 wriutn pt.-rmiWOfl of Sign,\rt. ©2015 CA,ra5622a BJ .'ir."i~ 9-2-15 Approved for: _____________ _ By: _______ _ Date: ____ _ Si t 10'-3" ------------1 +·r e:M,1~t-1n Sign #2 -Replacement Face For Existing Bullet Scale :>/a" = 1 '-0" .080 Aluminum face painted to match #2870 blue, precision routed and backed with Oat white polycarbonate. Note: American Sign Company , 5. '31¢ 10'·3' ~ 1'-6' 9¼" ~ GNC LIVE WELL Sign #3 -Replacement Face For Existing Bullet Scale:3/s" = 1'-0" .080 Aluminum face painted to match #2870 blue, precision routed and backed with Oat white polycarbonate. Note: American Sign Company Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 SIGNS #2 & #3 Lead #1085 Th"-' ll JO 0t-sinal unpubl~ dtJWlnt;, ,ubtruttN:t (or your Oji' 1-n c:onn«'lk>n ...... ~ • p,()j«t be,ng pl.uw,rd fo, yc,u by SignArt II it, not Lob(-,~,,odut«f topi,td or l"'hlbtl.rd I.fl .tny f.ast-M \\<1thoot wnt«-n pt-nnt~n of StgMf'L @2015 Date: CA,ra5622a BJ ,!;r.;ll, 9-2-15 Approved for: _______________ _ By: --.. Si t 1-------------4'·61/,"-------------< I .r. Ti RITE AID PHARMACY Sign #4 -Replacement Face for Existing Single-Faced Illuminated Monument Sign Scale:¼"= 1'-0" Existing 'RITE AID' face 10 be cul out and replaced with new precision routed .100 aluminum face painted semi-gloss to match PMS Mp06997 Perlino Bianco. Face to be backed with flat white polycarbonate overlaid with #2870 blue pressure sensitive vinyl. Face to be mounted to monument with countersunk screws painted to match. q' s<o ~ Nig_ht View Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 SIGN #4 Scale: NTS lead #108S Th,s ~ -,n ongm.11 unpublishtd drav.·,ng. submdted f0t yoor use in ronn«tk>n w..1h • p,oieca bc·ing pl.tMed to, )'OIJ by Sigv\tt 11 I) noc 10 bt ,epnxfuc:rd. copied o, t!Xhibil(-d in M'ry (.ashH)n w,thoul wnm.-n ~S6k>n of StgnAr1. ©201S CA,raS622a BJ .,r.-.-its 9-2-15 Approved for: _____ _ By: _____ _ Date: ____ _ Si t Illuminated Channel letter Detail Rite Aid #05622 -7100 Avenida Encinas, Carlsbad, CA, 92011 CHANNEL LETTER DETAIL G) .040 Aluminum letter sides painted GripCard semi-gloss to match #2670 blue. 0 1" trim cap with #8 x ½" hex head screws as needed. 0 Flat white polycarbonate faces. 0 G.E. Tetra MAX LED system. © Low voltage wiring from power supply. © Pre-drilled low voltage electrical hole with 1/a" plastic grommet. 0 V.-Weep holes al low points of letters with internal light baffle. © .050 Aluminum letter back. Letter sides and backs stitched together and continuously siliconed. ® Building facade; exact construction to be verified. @ Vertical stud by others. @ 20 Amp toggle disconnect (actual location to be on end of raceway, shown on top for drawing purposes only). @ 4• x 8" x 18' JIC box. @ Low voltage (12 volts) G.E. #GEPSl 2-60 LED power supplies (120 volt circuit required). @ Secondary wiring low voltage connection to LED's with #054007-06128 Scotchlok connectors. @ Ground wire permanently fixed to power supply box. @ ½" Sealtite connector. @ UL listed Belden #9409 1 PRl 8 AWG wire. @ ¼' Sealtite conduit. @ #12 THHN electrical primary wiring. White -Neutral Black -Feed Green -Ground @ Leners mounted to facade with ¼' stainless steel threaded rod, washers and nuts as needed. Exact fastener lo vary with different facade/building construction. Note: All penetrations to be sealed with 3M # 1000 NS Fire Barrier, water tight, non-slump silicone sealant to meet NEC #300.21, ASTM #E814, UL #1479 & UL #2079 standards. Building dimensions and construction of facade to be verified by sign installer prior to installation of signs. Scale: 2" = 1 '-0" Lead #1085 Tho i,..., orig,MI unpubh,htd dr>w,ng. ...bmn~ ro, your..., In """"""kin "lth • pn,j<a belnt; pl•nnod ro, you by Sipw, 11 h noe 10 be rop,odU<t'Cl, copied°' .,.hlb,ted in n.ny /..Non ,.;lhouc wri1ton pe,mi!1ilon ol Slgr\M. IC2015 CA,ra5622a BJ .. mu. 9-2-15 Approved for: _______________ _ By: __ _ Date: ____ _ . . __.,-