Loading...
HomeMy WebLinkAboutPS 16-03; ALICANTE APARTMENTS; Sign Permits/Programs (PS)4(cicyof Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov ~~~Tt~~~~~twQ3 SIGNF~E~ ........ .a:a,._ ___________ _ SIGN PROGRAM FEE ________ _ RECEIPT NO. ___________ _ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: 6 L. J_ CA >--1 IE A pQ.fl~ _ Address of Project: 2 3 B: J CA tl I A.I 6 A WA '1 . C lt-R L. > f:> A J) j Assessor Parcel Number: 21 S -Z 4 0 ·-4 L -00 Related Planning Case Number(S): GE -15 -012.~ a) Residential (d) Hotel/Motel (g) Theater TYPi F DEVELOPMENT: . Commercial (e) Service Station (h) Gov't/Church/School 0) Produce Stand (k) Nursery ( c) Office/Industrial (f) Prof. Care (i) Public Park (I) P-U/0S Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesO No~ Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes, please complete information on page m Yes 0 SOUTH CARLSBAD COASTAL REVIEW AREA Yes 0 No!R No,B: SIGN ORDINANCE: YesS No D COASTAL ZONE: Yes • Nol& P-11 Page 1 of4 Rev. 10/13 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument I ~2 -SF 'S'' w I n 11 . Wall Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes• No • Date . ______ _ PROPOSED PERMANENT SIGNS: TYPE MAXIMUM NUMBER NUMBER ALLOWED PROPOSED Pole** Monument,..,, Wall Suspended/Projecting Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER TYPE "'UMBER PROPOSED ALLOWED Construction** For Sale** Banner I Interim MAXIMUM PROPOSED MAXIMUM PROPOSED SIGN SIGN AREA SIGN SIGN AREA HEIGHT HEIGHT ~r · q..s sF MAXIMUM PROPOSED MAXIMUM PROPOSED SIGN SIGN AREA SIGN SIGN AREA HEIGHT HEIGHT . **Prior to approval, all proposed pole, monument, .and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application. showing how the proposed signage will not encroach Into the public right- of-way or present a traffic hazard. . Page 3 of 4 illustrates an example for what would be req·uired for such proposed signs. P-11 Page 2 of4 Rev. 10/13 I • srre PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN AP-PLICATION$ Th.a following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I J I t P/I. 1 Sipt Dis~e Requirement Show buildin1/s I I I I I I ~---I Show sethac:ks f!'Olll, all c:m-bs --- I I I ' t I I Show all property lines I P/I. ' I ' § ·: I curb line • I I . ----------~--- • • Sipt Visillility I S1reet Name(1) Ci) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: ________ sq. ft. Total Building Street Frontage: linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Paga3of4 Rev. 10/13 -----~---~-- PROPERTY OWNER APPLICANT NAME PRINT OR TYPE MAILING ADDRESS MAILING ADDRESS CITY STATE ZIP TELEPHONE CITY STATE ZIP _ TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INF=ORMATION IS TRUE A D CORRECT TO THE BEST OF MY KNO EDGE. DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I-rz.-1 DATE 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right•of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ~; ~ Date:ci -3-/ (a P-11 Page4 of4 Rev. 10/13 -- . -----.·-'·'-~ ··:;_:• .. · · .. ---------- . -· -. ·. " . ------ . -~ · .. ,·,;-'• ------ :• ·• ..• •' ·' -------EXISTING MONUMENT SIGN LOT-29 I I . ---· .. --~---.:~·-._. · .. ·.·:.:-· . .--. ~ r ------::·~ ·. · .... , ..... ~----:-:--~.---- CARI NGA WAY (60') .... -~--~--~~-~-~-~ ·. ... LOT-5 I I I I .. _.. ·-> '• .•.·· ·- D,..1/.: , r .. .:. -.:_ : . . .. ' w: . R/W . .__ :· ... . I I I I -N- c.o t s;t" N LOT-42 . : •... ·_·_ .•,..: ·•, . ;: ---------~--·•"·· .•.. -~--~-·•I"" ------·--... -------..... ------·-• ._'·'§°•·-·~. ~. ---------:·•,,,.-· .. ·· SITE PLAN SCAL[ 1" -40' R/W I I f------7'-6" -------, I ,--_..® :.----+-----71-1 ----------~ 42'----,----------i CENTER LINE ALICANTE RD ALICANTEAPARTMENT ,i-...1 ____ 10. ____ _ I HOMES I I I 2385 CARINGA WAY I , c;::,,,;;.· <o, ' . /4 .. , . BRICK WALL I . ~ I 1---i ,__ 2" CLR #4 @ 18" O.C. -_j 12" ~ SECTION A-A NOT TO SCAL[ ··• f(o---13 " ,.~ ' ,,, ·' ,., "-: ..... · ~-..... -" .. ------' ., ', ,,-. '··'•. - OWNER/ APPLICANT VILLA PACIFIC APARTMENTS, L.P. OBA AL/CANTE 1322 SCOTT STREET, SUITE 204, SAN DIEGO CA 92106 619-221-6825 SITE ADDRESS 2385 CAR/NGA WAY CARLSBAD, CA 92008 EXBTINGLEGALDESCRFTION MAP 6730, LA COSTA VALLEY UNIT N0.5, LOTS 229, 230, 2J1 & 232. ASSESSORS PARCEL NUMBER 215-240-42-00 AVIARA RD t ff!; I:::! -N-~ i' u ;)-,, ~ 01,: i ~ '1 Ir, r ... -,··~· ,, ~ s"' f§i s<t:-"--I? \'0 ~ u (;j (z_\.. SITE LA COSTA AVE VICINITY MAP NOT TO SCAL[ HIGHWAY DESIGN MANUAL CALTRANS (2012 EDITION) Table 201.1 Sight Distance Standards ~(1) Design Spee-, (mph) 10 15 20 y _) 30 35 4-0 .50 55 6s , 75 100 125 150 .200 25.0. 300 1 360 430 5!)() 660 750 840 930 (fi) 200 950 l,!00 t,3()0 L500 l,650 !,800 l 9'\0 ... - 2,JUO 2,300 J,5()(1 2,600 2JOO SIGHT DISTANCE ANALYSIS 1--z wz :?! (9 :::) -z Cf) 0 :?! Date: 26 AUGUST 2015 Scale: AS NOTED Drawn: SB Checked: File No. Job No. PWR-18 Sheet C-1