Loading...
HomeMy WebLinkAboutPS 16-13; CISCO; Sign Permits/Programs (PS)(city of Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING APPLICATION# fS 16 ·I'.} REC'DBY ~!<--DATE -,,2---...::8:i.;,-_,\-r(p-------- SIGN FEE 6/ti2,- SIGN PROGRAM FEE _______ _ RECEIPT NO. __________ _ All plans submitted for sign pemiits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). 8. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The appllcatlon must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: Cisco Address of Project: ____ 3_1_1_5_M_e_l_ro_s_e_D_r_iv_e _____________ _ Assessor Parcel Number: __ 2_2_1_8_8_0_1_3_00 ________________ _ Related Planning Case Number(S): __________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) (b) Commercial (e) Service Station (h) (c) Office/Industrial (f) Prof. Care (i) SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Theater Gov't/Church/School Public Park (j) Produce Stand (k) Nursery (I) P-U/OS Zone Yes• NoD Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes. please complete information on page 3) SOUTH CARLSBAD COASTAL REVIEW AREA YesB Yes Noa No SIGN ORDINANCE: Yes• No• COASTAL ZONE: Yes• No• P-11 Page 1 of4 Rev. 10/13 -------~---- EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes • No • Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Pole•• Monument•• --. Wall I:;-r -•1tt.tJ. 2 IL)~ 25SF ',/p II t~' .. J r-" "'h1'v Suspended/Projecting Directional Canopy Freestanding•• (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Construction•• For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and vislbillty issues. Additional information must supplement this appllcatlon showing how the proposed slgnage will not encroach Into the publlc right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 10/13 ' SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I ' P/L I Si&ht Di•:•• Requirement Show builctin&I, i ' I I j °':---l Show setbacks from all curbs --- ' I I ' I I Show all property lines ' P/L : I :7 I curb line • I -------------- • • Siaht Vuibility l Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: __ q.._tf_,_o/t_,__.g___,__~~ sq. ft. Total Building Street Frontage: 260 linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: _________ inches P-11 Page 3 014 Rev. 10/13 PROPERTY OWNER APPLICANT NAME !PRINT OR TYP"" NAME (PRINT OR TYPE\ H A Melrose, LLC Stan ldeker MAILING ADDRESS MAILING ADDRESS 11909 San Vincente Boulevard 4036 Kansas Street CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Los Angeles CA 90049 tiego CA 92104 619.990.0185 I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. So-,I .d . A, . i Feb. 05,2016 Afr= .Jbt),_._,__ Feb.OS, 2016 SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ____ ....;&/=-i..:.l'l-_______ _ Date:. __ z---'-/_,;--'-/2'-b- P-11 Page4 of4 Rev. 10/13 ,111111~ CUSHMAN & WAKEFIELD February 1, 2016 Jay Maag Jones Lang LaSalle Cisco Systems, Inc. 7100-7 Kit Creek Road PO Box 14987 Research Triangle Park, NC 27709-4987 Re: 3115 Melrose Drive -Landlord and Association Approval of Cisco Slgnage Dear Jay, 3870 Murphy Canyon Rd., Suite 150 San Diego, CA 92123 cushmanwakefleld.com The Association's Architectural Review Committee and the Landlord have approved your request to change the MalntenanceNet building sign to Cisco. You may now arrange for the fabrication and Installation of the new sign. Please provide us with the date of Installation along with the required insurance certificate for the contractor performing the installation. Insurance requirements are attached. All work shall conform to the Building, Fire and Electrical Codes of the City of Carlsbad. Please obtain all permits required for the execution of this scope of work. Prior to any on-site work, please provide Cushman & Wakefield with a copy of all City of Carlsbad approved stamped drawings and permits for Landlord's flies. You are required to repair any damage to the building caused by the Installation & removal of the MalntenanceNet sign. If you have any questions, please feel free to contact me at (858) 625-5276 or amy.schraeder@cushwake.com. Amy Schraeder Senior Property Manager No warranty or representation, expressed or lmplled, Is made as to the accuracy of the Information contained herein, and same Is submitted subject to errors, omissions, change of price, rental or other conditions, withdrawal without notice, and to any special listing condltlons, Imposed by our principals. Site Plan -• p;CJ ------✓- /// ✓- ✓-;' , I I I I ' I I I , I , ~ Sig) ' ____________________ J Melrose Drive s::GN PEl{MJT NO. PS ~~ APPROVED BY DATE :,:..Ai<:NiNG I 6 \L 1.,..-;~ ,~ .:::~DING I j © Address: 3115 Melrose Drive Carlsbad, CA 92010 Project Title: Cisco Scope of Work: (1) Set Illuminated Channel Letters 25 SF each Owner's Information: H R Melrose, LLC 11909 San Vincente Boulevard Los Angeles, CA 90049 Assessor's Parcel #: 221 880 13 00 t ® Vicinity Map s:: Site-DI I 0 ::i. < El Camino Real 1 <1J 9177 CHESAPEAKE DRIVE SAN DIEGO, CA 92123 (858) 278-6152 CISCO 311 5 SOUTH MELROSE DRIVE CARLSBAD, CA 92010 CISCO 3115 SOUTH MELROSE DRIVE CARLSBAD, CA 92010 PREPARED BY IHOU~ I REVISIONS 01 02 03 04 05 06 07 08 09 10 ' THIS DOCUMENT IS THE EXCLUSIVf 'ROPElrt OF SPA!Nl SIGNS Of SAN DIEGO ANO MAY NOT IE como, lE'1100UCED, MANUFACI\JREO, MAAKITED OR SOLO IN WHOLE OR IN PART WITHOUT THE EX,RESS WltlTTEN CONSENT OF Sf'ltlNT SIGNS Of SAN DIEGO lrct·Hfiffef.i~ CISCO • CARLSBAO JOB NUMBER I EQ EQ EXAMPLE OF EXISTING SIGN ON SITE EQ I ·-., . •• f•• 1:I •-• EQ B PROPOSED EAST ELEVATION SCALE 3/16" = 1 '-0'' THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE ARTICLE 600 AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. PAGE 4 OF 4 ,· 9177 CHESAPEAKE DRIVE SAN DIEGO, CA 92123 (858) 278-6152 CISCO 11 3115 SOUTH MELROSE DRIVE CARLSBAD, CA 92010 11 CISCO 11 311 5 SOUTH MELROSE DRIVE CARLSBAD, CA 92010 l~iH:tl1iH•J:t4 I HOUSE 1;fa+]i.1t•m.j 01 02 03 04 05 06 07 08 09 10 THIS DOCUMfNT IS THE EXCLUSIVE rROl'EIITY Of Sl'ltlNT SIGNS OF SAN DIEGO AND MAY NOT IE COPIED, REPRODUCED. MANUFACTURED. MAIIIC£TED OR SOLD IN WHOU 011 IN l'AIIT WITHOUT THE Ul'IIESS WRITTEN CONSENT Of SPRINT SIGNS Of SAN DIEGO ~M:•~tM,~rM:•~1@1:,,i, CISCO -CARLSBAD 83" L CISCO i t'J'' J_ MAKE ONE (1) p-=--j 1B NEW SINGLE FACED ILLUMINATED WALL FLUSH MOUNT WEATHEIINtOOF ACCESS 00011 ---- DISPLAY SCALE 3/8" = 1 '-0" USE STANDARD ALUMINUM CONSTRUCTION WITH MAP SATIN FINISH, LETTERS USE REVERSE PAN CHANNELS WITH WHITE LED HALO ILLUMINATION, PAINT 3" DEEP RETURNS TO MATCH FACE COLORS, VERIFY EXACT POWER SUPPLY LOCATION(S) PRIOR TO INSTALLATION. SIGN TO BE UL APPROVED AND BEAR UL LABEL. -PANTONE 661 C BLUE ALUMINUM WRAmD IACKGIIOUND WITH ANGLE l'HIMETH AND STIUTS 112• PVC SLEMS ---- .063 ALUMINUM ltET\lltNS ----, WELDED AT SEAMS ----- •11 GROUNDING Wlllf 10 t,\fTAl LfTT£1t 1/4" MOUNTING IOLT ---- 1 1/2" H LOWVOLTAGI! LED LIGHTING ---I •II HFfCO STIIAIN ltEUEF IUSHING CLEAII LEXAN IACKS --I ill .090 ALUMINUM FACE 1/2" MOUNTINC. IOLTS INTO !XMNSION SHIELDS MOUNTING SURFACE ------- SECTION REVERSE ,AN CHANNEL WITH LED IUUMINATION 2• DUI' ALUMINUM RACEWAY wm4 DISCONNECT SWITCH l'OWH SUl'PI.Y J-IOX, POWEii SUl'PI.Y WITH l'ttlMAltY l'OWflt SUl'PI.IED r, OTHEltS SIGN TO IE UL Nl'IIOVED AND HAR UL WEL THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL EUCTRIC CODE ARTICLE 600 AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF SIGN. PAGE 3 OF 4