HomeMy WebLinkAboutPS 16-16; RAMEN FACTORY; Sign Permits/Programs (PS)~
' c-Cityof
Carlsbad
REVIEW FOR
SIGN PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www_carlsbadca_gov
PLANNING AP.P.LICA TIO.J:J #~~flj-----'I ~-~_,_/.,_{, __
REC'D BY ' ~ye
DATE v/ I Ip It Ip
SIGN FEE 10'2 -
SIGN PROGRAM FEE ________ _
RECEIPT NO. __________ _
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and
sign elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The a lication must be submitted
Name of Project: __ .1::::.A~M:....:...:€:...,v,:__ __ +-..:.....:c=..._.!.:..!e<:.:;::_,1--___________ _
Address of Project: ----'-=---'-'='------,,-!--=-=:.....::....:__ __ =-.;;__--::::...._-~-#'-'----'-l.:...I_,_/ __
Assessor Parcel Number: ---"---'--..l....--'-=-:=-----'c....:.-=-==-------------
Related Planning Case Number(S): ___________________ _
TYPE OF DEVELOPMENT:
(a) Residential (d) Hotel/Motel (g)
(~ Commercial (e) Service Station (h}
(c) Office/Industrial (f) Prof. Care (i)
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA
Theater
Gov'tlChurch/School
Public Park
U) Produce Stand
(k) Nursery
(I) P-U/OS Zone
Yeslil}' No~
Specific Plan Number ____ _
VILLAGE REVIEW AREA (/fves. please complete information on page 3) YesB Yes
Nogl
No~ SOUTH CARLSBAD COASTAL REVIEW AREA
Yes!E Nol(
Yes~ NoO
SIGN ORDINANCE:
COASTAL ZONE:
P-11 Page 1 of4 Rev. 10113
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument , , ,. ,
Wall ~
Suspended/Projecting
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes • No • Date ______ _
PROPOSED PERMANENT SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Pole**
Monument••
Wall ,., I Pr I 11-~ II, x-qt( -'Y.':__ f)y''
' Suspended/Projecting
Directional
Canopy
Freestanding••
(Project Identity)
Digital Display
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Construction** -----
For Sale** -Banner --......
Interim
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-
of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be
required for such proposed signs.
P-11 Page 2 of4 Rev. 10/13
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I I '
P/L • Sight Distance Requirement
• I
Show building/s i I
I I : I
• I I ,_ -l Show setbacks from all curbs ---: ' I I
' : I Show all property lines I i P/L I
: l I •
curb line . I
----------~---
Sia}tt Visibility
I
Street Name(s) (i) I
I North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA µ /Ar
Total Building S~UAff Footage: ---=-------sq. ft.
Total Building ~rontage: % linear ft.
Total Signage Allowance: \ /}_ sq. ft.
Existing Signage (sq. ft.): sq. ft.
Remaining Sign Allowance at Present: sq. ft_
Proposed Signage (sq. ft.): I\ . B4 sq. ft.
Remaining Sign Allowance After Proposed Sign: •II sq. ft.
VILLAGE REVIEW AREA NI A
Total Signable Area: sq. ft.
Total Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: _________ inches
P-11 Page 3 of4 Rev. 10/13
PROPERTY OWNER APPLICANT
NAME (PRINT OR TYPE) NAME (PRINT OR TYPEl
_JA.ck1i C4tc/ (;DAL A1VGtC L
MAILING ADDRESS MAILING ADDRESS
Joo (i BAkzlL sJ · s ,./. I ocJ 1--.so /Uf {,t/A 1/
CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE
co;.~ Nts.t:::. ,cA-~6 8-l.'I< -:,.q 3 -:;~7-s~v {); [Gu . c',,'1 . <f:J-rsc.r
I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE
AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE
IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT
MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE.
5££ A--liAdr {) -,;) -/( /~//4~ ;;J-d -IC
SIGNATURE DATE SIGNATURE (./ DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: ❖ In right-of-way ❖ In visibility triangle at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved rout,;-M"" +n n,,,,. Fntrv
APPROVED: Planner:-· Gi ~~1? i/~lt¢> Date, /
P-11 Page 4 of 4 Rev. 10/13
2'-
Ra men Factory -----__ -~-~ -·
Scope Of Job / Wa 11 S ·g 7040 Aven ida Encinas #111 Carlsbad, CA 92011 £:GNPE_.{!.!VUfNO.PS! ,r;,/t RAMEN FAC 0 I n Owner Name: Nabe 619) 818-6599 , : l RY
Legal description: Par2, Map#15187 i--~:':>rm~ ii rh,:rEN.ANT
............................. , .. ~Pt-J, 21.4:43~., ~·.(){) '. .. s1!E "'·RE.A, .2:6 ! .G'<>''. ~er"'.. . . .',. :: ~ ''::. ~:-:-.. :-. ~ ... ·" .. ~~ ~.L?ET -· S I G NAG E
7
SCALE: 10/16" = 1 '-0"
c)O~
9'-1 "
3 ---~----------------------· Sign Area
Bounding Box
J ,-
··11···· .. ... . ·······-···
, .. = .. lCrDBl!t···t~················~~:n~ii~~ ~~:
7'
WEST ELEVATION
STORE FRONTAGE: 20'-0"
• Sign Area Bounding Box:
9'-1" X 2'-1 "
· • Minus Non Sign Area:
1) 38-0919 Square Inch
2) 38.0919 Square Inch
3) 244.003 Square Inch
4) 134.409 Square Inch
5) 30.4700 Square Inch
6) 48. 7 422 Square Inch
7) 197.393 Square Inch
8) 38.0919 Square Inch
9) 232.223 Square Inch
10) 38.0919 Square Inch
Total
* Sign Area Bounding Box:
* Minus Non Sign Area:
Total
19.11 sq.ft.
0.2645 sq .ft.
0.2645 sq.ft.
1.6944 sq.ft.
0.9333 sq.ft.
0. 2115 sq .ft.
0.3384 sq.ft.
1.3707 sq.ft.
0.2645 sq.ft.
1.6126 sq .ft.
0.2645 sq.ft.
7. 218 9 sq. ft.
19.11 sq.ft.
7 .2189 sq.ft.
11.8911 sq.ft.
SIGN AREA: 11.8911 SQ.FT
SCALE: 3/32" = 1 '-0"
* [~,==
INTERSTAE 5 r
~
e
,~ ., __
-
STANDARD FACE & BACK-LIT CHANNEL LETTERS
"RAMEN FACTORY & LOGO": TO BE 3" DEEP .040 ALUMINUM CHANNEL RETURN BLACK FEACTORY PAINTED
USE STANDARD ALUMINUM CONSTRUCTION WITH
3/16" FLEX ACRYLIC FACE VINYL OVER LA VS
-ARLON 253 TRAN. RED & 5590 DUAL FILEM DAY & NIGHT
.72 W WHITE SYLVANIA WHITE LED'S WITH 60 WATT POWER SUPPLY
1-1 /2" SPACER FROM WALL MOUNT
METAL SCREWS TO BE USE MOUNT/UUUV RATED
16GA. CABLE WITH UL SLEEVING
STANDARD FACE & BACK-LIT CHANNEL LETTERS
ALUMINUM CHANNEL
FECTORY BLACK RETURN---~
SCREWS
#12x2.5"W/PI.ASTICANCHOR -;=J~ ~
GROUND WIRE ---
FABRICATED ALUMINUM
~-----RACEWAY
1/2" FLEXIBLE METAL
'I 'f:'. CONDUIT
1 W • -., I DISCONNECT SWITCH
::::::D:~K:UL~1=:1 11 ~1r ~ 1
~JUNCTION BOX
* ~ TO ELECTRICAL J-BOX
WHITE REX WITH --
VINYL OVERLAYS
3/4" JEWELITETRIM CAP ~1 EDGES WITH RETAINING SCREWS-I
I 3'DP. J
RETURNSl 1•1fl' SPACER
1. I.J..,\N RAlED / 16GA. CABlE WITH UL SI.EE'v1NG FROM LIDS, THU WAU.
CQN\ECT1IIG l£TTER TO I..ET1ffi
2 U.lf'OMcR SU'l'IYMO.MBl INSOE EXISTING l,ETAI.SU'PQRT Pl'CfWAY
3. J..l'ICl10N BOXWITH U.';!JNIP SEIMCE OISCCllffcCT MOLffiED BEHIND
WAU./INO SU'l'LED BY OJSTOMER.
4. WlN RAlED 16GA. CABIEWITH U.SIEEVf,(, FROM J..l'ICl10N BOX THRJ
WAU. TO LB)'$ INS()E LETTERS-
5. PAIMARI' El..ECTRICAI.NSOE U. CONOUTTO.u-cnoN BOX. PRIMARY
TO BE-Fl'IE FEET Of SIGN /IND SU'l'LED BY 0JST0M,R. ®
6. AU. lllt.1ENSIONS N NCI-ES U'USS cm£RWISE NOTES IJL
LISTED
Ramen Factory
Scope of Job / Wall Sign RAMEN
FACTORY
7040 Avenida Encinas #111
Carlsbad, CA 92011
1111 t\ . slfNs· 4706 Ruffner St. #A
--• San Dieg-0 CA 92111
~ :l 6101488
II
Owner Name: Nabe 619) 818-6599 / G oo 8744477
~ ?P. hr -r(f1C0
··-· FACTOBrJl-l"(l'J
STANDARD CHANNEL LETTER //v/rl,
, 6,, ,. "RAMEN FACTORY & LOGO":TO 5" EEP .040 ALUMINUM CHANNEL RETURN -It-, sr-"'6'1<.,.1 ]~ck,
l -os l US DARO ALUMINUM CONSTRUCTION WITH fpf~
3/16" FLEX ACRYLIC FACE VINYL OVERLAYS f
II , .72 W WHITE SYLVANIA WHITE LED'S WITH 60 WATT POWER SUPPLY
fl '5~le..., EbYal::I lO lHE WA! b MQYPH
I METAL SCREWS TO BE USE MOUNT / UL/UV RATED
16GA. CABLE WITH UL SLEEVING
ARLON TRANCELUCENT 253 CARDINAL RED
17'-6"
11 '-3"
7'
Approved as Noted
j)A-rd4 <//J~itff
et75.f/' 9i<AD£
~~ln7kjL_2
~0-w -S-~~
ALUMINUM CHANNEL
FECTORY BLACK RETURN
SCREWS
#12 x 2.5' W/ PLASTIC ANCHOR
GROUND WIRE
3116' CLEAR LfXAN BACKS
-I
'
ARLON 5590 DUAL COLOR FILM(DAY BLACK & NIGHT WHITE)
SECTION
SIGN TO BE UL APPROVED AND BEAR UL LABEL
PLEX FACED CHANNEL LETTERS WITH LED ILUMINATION
IIOTE:
1111 -11 IITBIOED TO IE IIIITAllED lll ACCOIIIAIIC£ wmt l1IE REGUIIE.-rl
Of MT1Cl.f • Of 1Hl IIA1lGIIAI. EUCTllCAI. l:OIIE AIIIIOR CIIIIER N'l'UCAll£
lOCM COIIES.11111 IIICI.IJIIES l'IIOPBI ---Of l1IE 111111.
STANDARD FACELIT CH ANNEL LETTERS
EXISTING WALL FABRICATED ALUMINUM
RACEWAY
1/2' FLEXIBLE METAL
CONDUIT
DISCONNECT SWITCH
,:'.::Iz'0, ~-_ JUNCTION BOX
[lf'~--+ • TO ELECTRICAL J-BOX D Not Approved, Returned for Corrections
LOWVOLTAGELED MODULES r· --+-j 1,
1 ULJ\N RATED/ 183A CABlE WITH UL SlEEvlNG FroM LED'S, ll-lRU W/lli
CONNECTING LETTER TO LETTER
Construction ~
Property Mgr. JAo.i<iii:
Leasing Agent f>A«,t 7n.A,'P
Henry Avila A)'J"/Wll&V
DONAHUE SCHRIBER
WHITE FLEX WITI-i
VINYL OVERLAYS
3/4" JEWEUTE TRIM CAP
EDGES WITI-i RETAINING SCREWS
I s• DP. l
RETURNSl
2. u.L FOWER SUPPLY MOUNTED INSIDE EXISTING METAL SUPPORT RPCEWAY
3 JJNCTION BOX WITH UL 20AMP SERvlCE DISCONNECT MOUNTED BEHIND
W/lli AND SUPPLIED Bl' CUSTOMER.
4 ULJ lN RATED 183A CABlE WITH UL SLEEVING FROM JJNCllON BOX ll-lRU
W/lli TO LED'S INSIDE LETTERS.
5 PRIMARY El£CTRICAL INSIDE UL CONDUIT TO JJNCTION BOX PRIMARY
TO BE 'Mll-llN FIVE FEET OF SIGN AND SUPPLIED Bl' CUSTOMER.
6 /lli DIMENSIONS IN INCHES UNLESS Oll-lERWISE NOTES ® LISTED