HomeMy WebLinkAboutPS 16-75; BARE & BEAUTY; Sign Permits/Programs (PS)Ccityof
Carlsbad
REVIEW FOR
SIGN PERMIT
P-11
PLANNING A
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
. REC'D BY
DATE
SIGN FFEE~~~~=======
SIGN PROGRAM FEE ________ _
RECEIPT NO. __________ _
All plans submitted for sign permits/sign programs shall consist of a minimum of a Site plan and
sign elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE. .
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
Name of Project: 6o{e_ + \)equry
Address of Project: S<t>-ac, po..se.o Pe..\ Y\() (te_
Assessor Parcel Number: :;;;l. / I -0 cl "Q-0\ a--
Related Planning Case Number(S): ___________________ _
TYPE OF DEVELOPMENT:
(~) Residential ( d) Hotel/Motel (g)
@. Commercial (e) Service Station (h)
(c) Office/Industrial (f) Prof. Care (i)
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA
Theater
Gov't/Church/School
Public Park
G) . Produce Stand
(k) Nursery
(I) P-U/OS Zone
Yes □ No~
Specific Plan Number ____ _
VILLAGE REVIEW AREA (If yes. please complete information on page J) Yes D
SOUTH CARLSBAD COASTAL REVIEW AREA Yes 0 No □ No □
SIGN ORDINANCE:
COASTAL ZONE:
P-11
YesD
Yes □
No □
No □
Page 1 of4 Rev. 10/13
,
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument
Wall I Q(\_ f==u... \ ' , . . I,.,
Suspended/Projecting
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes 0 No 0
PROPOSED PERMANENT SIGNS:
Date 'o/1ajr(p
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Pole**
Monument**
Wall l r.',-,,'' \ 'r,., ,, I' \ . ,. ,,
,_, f , ...
Suspended/Projecting I 1· I,~· "l.u h--I I I ,
Directional
Cii.nopy
Freestandi_ng**
(Project Identity)
Digital Display
PROPOSED TEMPORARY SIGNS:
.
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
Interim
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-
of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be
required for such proposed signs.
P-11 Page 2 of 4 Rev. 10/13
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I I '
P/L : Sight Dist~ce Requirement
Show building ls i I
i I : I
i I
'.---l Show setbacks from all Ctll'bs .. "
' I I
' I I Show all property lines ' P/L i I
' . I ·:
tlD'b line • • ! ----------~---
• •
Sight Visibility I
Street N ame(s) Ci) I
' North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
Total Building Square Footage: _________ sq. ft.
Total Building Street Frontage: @,<,, ' 1 '' linear ft.
Total Signage Allowance: sq. ft.
Existing Signage (sq. ft.): sq. ft.
Remaining Sign Allowance at Present: sq. ft.
Proposed Signage (sq. ft.): q:O, I${ sq. ft.
Remaining Sign Allowance After Proposed Sign: sq. ft.
VILLAGE REVIEW AREA
Total Signable Area: _________ sq. ft.
Total Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3 of 4 Rev. 10/13
,
PROPERTY OWNER APPLICANT
NAME PRINT OR TYPE NAME PRINT OR TYPE
MAILING ADDRESS MAILING ADDRESS
CITY STATE . ZIP TELEPHONE CITY STATE ZIP TELEPHONE
I CERTIFY THAT I AM THE LEGAL OWNER
AND THAT ALL THE ABOVE INFORMATION
IS TRUE AND CORRECT TO THE BEST OF
MY KNOWLEDGE.
SIGNATURE DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
I CERTIFY THAT I AM THE REPRESENTATIVE
OF THE LEGAL OWNER AND THAT ALL THE
ABOVE INFORMATION IS TRUE AND CORRECT
TO THE BEST OF MY KNOWLEDGE.
DATE
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: ❖ In right-of-way In visibility triangle at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner: ~ ,J(}eJ(~ Date8 /10 ft k2 I t
P-11 Page4 of 4 Rev. 10/13
,
Date:
To:
Company:
Email:
Tenant:
CC:
August 1, 2016
<X>
CARLSBAD
PREMIUM OUTLETS"
A SIMON CENTER
SIGN APPROVAL
From: Danielle Jones
Lisa Birschbach Tenant Sign Manager
Priority Sign Premium Outlets
lisab@prioritysign.com dajones@~imon.com
<X>
SIMON
PREMIUM OUTLETS
Bare Minerals, Suite #D121
Carlsbad Premium Outlets
THIS NOTICE, TOGETHER WITH THE ATTACHED, MARKED-UP SIGN DRAWINGS, CONFIRMS LANDLORD'S
WRITTEN APPROVAL (AS NOTED) OF THE SIGN DRAWINGS AND ELEVATION FOR THE REPLACEMENT
STOREFRONT & BLADE SIGN FOR BARE MINERALS, SUITE #D121, AT CARLSBAD PREMIUM OUTLETS.
Tenant is authorized to proceed with installation of its signs in accordance with the drawings, and as otherwise noted by
Landlord. Tenant or its contractor must field verify mounting height and special mounting conditions with onsite
management team of all signage included in this approval. Tenant's sign contractor must make an appointment with
Landlord's onsite management team (760) 804-9044 at least 48 hours before arriving to install the signs to confirm the actual
location of all signs on the building. The contractor will be required to sign all necessary forms and provide required
Certificate of Insurance and a copy of Tenant's sign permit at this meeting. Be prepared with plastic or tarps and painter's
tape to protect and cover all surfaces from dust and debris. NO duct tape or blowers allowed.
All signs shall be installed prior to Tenant opening at a place or places designated by Landlord. Tenant is responsible for their
sign installer to provide watertight installations from both the inside and exterior side of the wall penetrations and proper
cleanup of all surfaces upon completion. For tower signs, Tenant's installer must provide labeled photos of proper sealing
from inside and outside of sign install, making sure sleeves are shown where needed at EIFS facades, to LL at time of install.
Tenant shall also be responsible for any and all costs associated with illuminating their sign(s). Keep in mind, work needed
may include an electrician if circuit is not near location. Signs MUST be lit for opening.
Finally, Tenant and its contractor are hereby notified that any work, which involves cutting into or penetrating the existing
roof structure and/or roofing material must be performed by Landlord's Rooting Contractor at Tenant's Expense. Tenant shall
be liable for all damage resulting from unauthorized roof penetrations and their consequent effect on the integrity of the roof
and the warranties offered by the installer and manufacturer. Therefore, if it is determined that roof penetration is likely
required, Landlord must be notified in advance so that scheduling of its roof contractor may be available.
<><>
CARLSBAD
PREMIUM OUTLETS"
A SIMON CENTER
·Note: Landlord's approval herein means Tenant has met Landlord's sign requirements; It does not mean that Tenant has
complied with, and Tenant continues to bear full responsibility for compliance with, any regulatory, code and permit
requirements related to Tenant's signage.
~ Reverse Channel Illuminated Letterset
13'-13/8"
f bare.+BEAUTV11 ~
1
4'-5 7/16.
1
r 7'-2 5/8" 1
Scale I 3/8" = 1'
SF I 20.18
11 '4 f>r tvC ~tt-10 --
4'-r, La YC" r1--~1L::>J'l-
• 1-1112·
12 1/2"
M ,----stand-offs (paint to match wall}
Aluminum face and returns 09
exterior: gloss black mounting ---di~~'~ varies per site
power
supply
switch
interior: Spraylat Star-Bright White EF
t weep hole w/cover
angle fastener All electnca/ to be UL
Usted and Labeled
SIGN PERMIT NO. PS fCo::7 5 ~
L--A~P~P~R~O~V~E~D.!B~Y---~~~pn1~sign
BUILDING
Installation Guidelines
Remove existing letterset
Patch and repaint all holes
Install new reverse channel illuminated letterset
26'-1"
Existing letterset I 2'-4" x 11'-10 1/2" I 27.7 SF
Dllt: 6/22/2016
APPROVED
Approved As Noted -Upon receipt of permit from city/county
fabrication may be undertaken. Signs must conform to all Landlord
comments on these drawings.
Installation of sign to be coordinated with ~•r Management not
to disrupt business.
Must provide Center Management with copy of perm~ & insurance
prior to installation & verify proper glgn placement prior to install.
• Center Management must sign off on sign Installation when complete.
<X>
SIMON I ~ltEMIUM OUTL£TS L__------=~~===f!::~======___J~
By Danielle Jones at 12:19:12 PM, 8/1/2016
~ Reverse Channel Illuminated Letterset
Scaled Elevation I 1/8" = 1'
n instaU heiaht/location with Center Mana 1ronsite**
l!C -►-
-8: nar~
~ " 1
m•
Rwblons:
@ prior1tys1gn
26'-1 • storefront
--
Ill • ...
'I
---=---~ ti
FIio Loullon:
Altl>op<\COMC ..... \............,
Doi., 6/W20'16
~TD p
APPROVED
Approved As Noted -Upon receipt of permit from city/county
fabrication may be undertaken. Signs must conform to all Landlold
comments on these drawings.
• lns1al:ation of sign to be coordinated Will center Management not
to disrupt business.
• Must provide Center Management witll copy of penn~ & insurance
prior to lnstalation & verify proper elgn placement prior to instaA.
• Center Managemen! must sign off on sign Installation when complete.
<X>
SIMON I ~lltE:MIUM Oun.en I -·-··--·--·-',MIIWYM \f'J ~A<.l I]
By Danielle Jones at 12:19:12 PM, 8/1/2016
...
~ D/F Face Replacement
· 1 0 0 > ~ 0 .....
Scale I 1:8
@ prioritys1gn
R1¥1sions:
Updltedffillterlt
l I
3'-0"
2'-10" VO
2'-6 1/16"
1'-6"
APPROVED
Approved As Noted -Upon reoeipt of permit from city/county
fabrication may be undertaken. Signs must conform to an Landlord
comments on these drawings.
Installation of sign to be coon:linated with Center Management not
to disrupt business.
Must provide Center Management with copy of pennit & insurance
prior to lnstalatlon & verify proper sign placement prior to install.
• Center Management must sign off on sign lnstallatlon when complete.
<X>
SIMON
n
~ .....
en"
N
~JtrMIUM OUTLltTS
'>-Ml IVUfM \ fl L\N I _J ...r.a-.ty
By Danielle Jones at 12:19:12 PM, 8/112016
Installation Guidelines
Remove existing hanging panel
Install new D/F 2" think aluminum frame painted White
Panel inserts to be painted Gloss Black
Letterset to be 1/4" aluminum painted White
Mount using hook and eye bolts
4
Dito: 6/22/2016 I Clty/Stltr. CWbod CA
~ T1l PM: ~ I Address: 5630 -dOt Norto
Drllwlnq.
Slto Nome ! Clflsllld Promlam -I
~ Reverse Channel Illuminated Letterset
13'-13/8"
Installation Gui.deli.nes
Remove existing letterset
Patch and repaint all holes
Install new reverse channel illuminated letterset
[bW.8i + ~ E~,~T'1 I~
Scale I 3/8" = 1'
SF I 20.18
•I f--1112•
12 112·
M
mounting • .al~
stand-offs (paint to match wall)
Aluminum face and returns
exterior: gloss blade
interior: Spraylat Star-Bright White EF varies per site
conduiL....JilW"'\\11-
power
supply
switch
® pnontys1gn
r. I 3/16" thick clear acrylic
fl...+--Sloan Cool White LED's
f weep hole w/cover
angle fastener
Rtw11'ons:
Alt etec/r,cal to be UL
/..Jsterl and Labeler/
Existing letterset I 2'-4" x ll'-10 1/2" I 27.7 SF
.pp -----ti &
!D • -
-tr~ J
~
Center above archway entrance
F1le Loutlon: AnD,jle\CcnlC .... _y o.lo: 6/ZZ/ZOl6 I City/SIMO: C•~sbld CA
OOslqnor. TD PM: JU I AddrHs: S6JO PaMO dol Norto
Drowfnq.
Sit•-1 CW~N , .. m1 ... -1 IMM ■
4 ••
~ Reverse Channel Illuminated Letterset
Scaled Elevation I 1/8" = 1'
Rovtslons:
@ priontys,gn
26' -1 • storefront
flleloutlon: _,,one .... --.v
Dair. 6/W2016 I City/Stilt: Cartsbod CA
Oesq,or. TD PM: JU J Addrtu: 5630 PHH dol None
Dlowlnq.
Sit• HMM I camhd Prami1111 Ovllets I
•
... '
, ...
~ 0/F Face Replacement
3'-0"
2'-10" VO
2'-6 1/16"
1'-6"
Scale I 1:8
RffflioM:
@ pnontys1gn
~--/TD/7.5.16 X
I n J. I
Fie Locotloft:
Al1Dop(\C'""Oion1Nol.bNUly
Installation Guidelines
Remove existing hanging panel
Install new D/F 2" think aluminum frame painted White
Panel inserts to be painted Gloss Black
Letterset to be 1/4" aluminum painted White
Mount using hook and eye bolts
Dltt: 6/l2/2016 I City/Stilt: ~-CA
DHlqMr: TO PN: JU I Addrtn: 5630 PIHO CMI Nortt
Dnwlnq.
Sitt -I Cartsbd Prtmium Olllltb I
C49601