Loading...
HomeMy WebLinkAboutPS 16-94; ACE TUTORING; Sign Permits/Programs (PS)(city of Carlstiad REVIEW FOR SIGN PERMIT P-11 PLANNING . REC'D B DATE Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov SIGN FEE"::IL!!~-----------SIGN PROGRAM FEE ________ _ RECEIPT NO. __________ _ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: Ac a. I u.+a f, "'$ Address of Project: 1-c, <-t O Av €fl; Jc. [: l'\ cm,}<-, ~, t-<-lo I Ur l)l,-,1 CA-Orzo I( Assessor Parcel Number: 8-1'-1 -l/:i o • I '-1 -OD ~--~~~------------------ Re I ate d Planning Case Number(S): ___________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) /(151\Commercial (e) 'ief Office/Industrial (f) Hotel/Motel Service Station Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park 0) . Produce Stand (k) Nursery (I) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes □ No □ Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes. please complete information on page J) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes □ SIGN ORDINANCE: Yes □ No □ COASTAL ZONE: Yes □ No □ P-11 Page 1 of4 No □ No □ Rev. 10/13 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall I l').<,3 ~"'1..! ').. ,, Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes □ No □ Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** Wall ' /1.o'> ,,.1." Suspended/Projecting Directional Canopy Freestanding*' (Project Identity) Digital Display PROPOSE.D TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 10/13 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I ' PIL • Sight Distance Requirement • I Show building ls I I : I I I I I , ___ --f ShD"W setbacks from all curbs --- l ' I I ' I I Show all property lines ' P/L ! I I . , ·: I c1D'b line i I ----------~--- • I SieJrt Vmlrility StnietName(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: _________ sq. ft. Total Building Street Frontage: '.) D 1 -/ ' /" 1, linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): · sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): 11 •v 3 sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 10/13 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE\ Oo <1c-~1A e.. S c. IA r; be IL · Sc" Oi ,tJvt.. Cletf·1L•t S,c; il 1',,c.. MAILING ADDRESS MAILING ADcl'RESS ').ou C. \>\\.k er '5~ S-t,+< loo I q1. o Cordell Cr St.,tr. luJ CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE U>'.>t'\-~ ~ J-. C/'t-· Q 1bZ.-6 114 -<¼s _.._ <t_,l (c, ,UV\ C ,,4--Cf 1D 20 Gl'i-:)S''6-'1-1r I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. L\ no _ r,, ' : , i~D ~~ 0 q h6 / l,i \ e,..+} /? SIGNATURE DATE SIGNAH RE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved n~e co~y to Data Entry APPROVED: Planner~ 4 .,A.Lt:fC2::'.JI\..., Date: 9-d,O-lk::, P-11 Page 4 of 4 Rev. 10/13 August 30, 2016 Stephen Eggers ACE TUTORING DONAHUE SCHRIBER 1921 W. San Marcos Blvd., Suite 145 San Marcos, CA 92078 RE: Sign Response for Ace Tutoring Poinsettia Village Carlsbad, California The sign submittal received at our office for the above-referenced project has been reviewed and approved. Please use the comments noted on the drawings and the guidelines listed below to make any necessary adjustment to your documents and the installation of your sign. 1 . All signs shall be reviewed for conformance with the sign criteria and overall design quality and is not a plan check for dimensional errors, code violations or any other restrictions to the property. Approval or disapproval of sign submittals based on aesthetics of design shall remain the sole right of the Landlord/Manager. 2. Prior to the installation and manufacture of any sign, the Tenant shall provide Landlord with a copy of the sign permit from the governmental agency having jurisdiction. 3. Each tenant shall be responsible to repair any damage to any surface caused by the signage or its' installation. 4. Landlord reserves the right to periodically hire an independent electrical engineer, at Tenant's sole expense, to inspect the installation of all Tenants' signs. Tenants shall be required to have any discrepancies and/or code violations corrected at Tenant's expense. Any code violations, requests for sign removals, or discrepancies not corrected within fifteen (15) days of notice, may be corrected by the Landlord at Tenant's expense. 5. Upon vacancy, Tenant shall remove sign and restore fascia to original condition at Tenant's sole cost and expense within fifteen (15) days of expiration of term or earlier termination of Tenant's lease. August 30, 2016 Ace Tutoring Poinsettia Village Page 2 6. Exposed junction boxes, transformers, lamps, tubing, conduit, or raceways of any type are NOT PERMITTED. 7. Sign manufacturer's names, stamps, or decals may not be visible from the street or normal viewing angles. 8. Tenant's sign contractor shall install and connect sign display and primary wiring at sign location approved by Landlord. Signs are to be connected to the J-box provided by the Landlord, which is connected to the Landlord's house panel, and shall be wired to Landlord's control at Landlord's timer for uniform control of hours of illumination unless otherwise directed by Landlord. 9. Prior to sign installation, we require the following: a. A copy of your sign contractor's insurance certificate naming Donahue Schriber Realty Group, LP.: Donahue Schriber Realty Group, Inc. and all related affiliates, as additional insured (with additional insured endorsement page attached). b. A copy of the permit and the contractor's license. c. At least 48 hour notice of date of install and requesting access to electrical room, if required. Should any other contractor provide installations or other work on the site, please call me to coordinate insurance requirements. In the event that the above information contradicts the lease signage criteria, the lease signage criteria are to supersede. Should you have any questions, please call me at 858.793.5752. Sincerely, DONAHUE SCHRIBER DoQ~~ Director, Construction cc: Jackie Check, DSRG File 7040 Avenida Encinitas Ste 101 Carlsbad, Ca 92011 The drawings, designs. ideas and arrangements contained herein are and shall remain the property of San Diego Electric Sign, Inc. No part therefore may be copied or reproduced and used in connection with any other work or project other than the specific project for which they have been prepared, without written consent from San Diego Electric Sign. Inc. If upon submittal to a proposed client these drawings are not released with the afore mentioned consent. these drawings shall be promptly returned to San Diego Electric Sign, Inc.. and furthermore. signs shall not be produced in the likeness of these designs. SAN DIEGO ELECTRIC SIGN, INC., USES GREEN TECHNOLOGY LED 1111TH UP TO 5-YEAR MATERIALS 11/ARRANTY. ASK YOUR SALES PERSON FOR DETAILS. PERMIT PRINTS R4 SCOPE OF WORK: MANUFACTURE & INSTALL ONE (1) NEW FRONT LIT/ BACK LIT CHANNEL LETTER STOREFRONT SIGN MOUNTED FLUSH TO WALL ALL WORK TO COMPLY WITH THE 2013 CALIFORNIA BUILDING CODE & THE 2013 CALIFORNIA ELECTRICAL CODE AND ARTICLE 600 OF NATIONAL ELECTRICAL CODE .. z,s,:=:-~ -= = tt:=::~ ==------c• , --,.rt~ ~-,-, ''"0 P"' I'_ a'-/ ..:..i.t...~ c...:.,· ... iL..!I i'II • ..) __ \CJ-_7 _~ "'''" ~[,,;~,,~; .. : ~•.-r,_, ; j L--,___ ----------·- PREPARED BY ~an· Diego El~cf~tC _gijn K INSTALLATION· DESIGN· FABRICATION CA LIC #750379 1920 CORDELL CT #103, EL CAJON CA 92020 PH 619.258.1775 FAX 619.258.1805 / ALL SIGNS SHALL BE UL LISTED. ' N '.Jil:l.nir.t< ' ... _ 'I , . ',!J~I . ;, ~4,-•~ llrpamnrnt or lHuilhing null enfrty Q:rrtificah> or Approuttl FABMICATOM LICENSE "<UM8EM ~800047 'rll/S Ct:lt1Irll:S TIIAT San Die-to Ek-ctrit' St&o Inf. Ar 1920Corde!II ('1 't1ilc 101 f; fe_J(III, (A •HOW LOCATrD IS APPffCVED l!IY THE. D£PARTr<lcNr or BUILDJHC ANn SAFl?'Y UHD£.R TH£ Plf0YlSIOH3 or srcr,on 96.10] or THE: LOS ANG£LtS M UNICIPAL COD£ AS A\Pl-.Cl\l"l\\1(1,"Al'l>',UP,POR~ Llt.llf\\[IVlff\Tf□.I\\~. •n -\pril05.:w1:;, .,..,.:. .a-"-\f"il. OJ "'lln ---~'.'lffoA'"l:·f!ll:~Qft-.<:T:°¥Nla,.....-.au. -""'-?aW'f',;,(t'.,-•~1 ·• ,a-·.1.•-.i:i,..._..,.rc;sn111M1~•.f'«A-•Ol..,_W _:5., -/;o::" .. r-..1~1~aJtr * 7040 AVENIDA ENCINITAS VICINITY MAP ~ u \ 20'-1 112" FRONTAGE ' N \ SITE PLAN ACE TUTORING 7040 AVENIDA ENCINITAS #101 CARLSBAD, CA 92011 APN: 214 -430 -14 -00 LOT: 2 MAP: PM15187 SCOPE OF WORK: MANUFACTURE & INSTALL NEW INTERNALLY ILLUMINATED FRONT LIT / BACK LIT CHANNEL LETTERS MOUNTED FLUSH TO WALL SIGN LABEL DESCRIPTION PROPOSED PROPOSED PROPOSED IUUMINATION (PRINTS) HEIGHT LENGTH/WIDTH SQ.FOOTAGE A WALL SIGN r-2· 1r-1· 12.03 LED • ~an Diego £/ectlcic .s'i~ INSTALLATION· DESIGN· FABRICATION CA uc•1so11t Client: ACE TUTORING Job: NEW STOREFRONT SIGN Address: 7040 AVENIDA ENCINTAS #101 CARLSBAD, CA 92011 Salesperson: CHRISTY BALLARD Date: 08/23/16 Drawing#:A Revisions: Rl : Reduced sign to 17"; added suite measurements R2: Reduced sign to 14" and added back lit R3 : Revised frontage and reduced signage R4: Revised square footage ART TIME I DATE I REVISION NUMBER 1.00 08/01/16 PRELIMINARY PRINTS ----1.00 08/08/16 PRELIMINARY PRINTS Rl 3.00 08/23/16 PERMIT PRINTS Rl 1.00 08/29/16 PERMIT PRINTS R2 .50 09/15/16 PERMIT PRINTS R3 .SO 09/16/16 PERMIT PRINTS R4 A<CIE 1rlUJ1r(O)]fil[J~KG Providing electrical to the sign location is the responsibility of others. San Diego Electric Sign, Inc. Does NOT provide electrical to the sign location. CUSTOMER APPROVAL OF DESIGNS: Client Signature Date Landlord Signature Date PAGE 3 OF 6 El 20'-1112'' FRONTAGE SIMULATED DAYTIME PHOTO OVERLAY SCALE: 114• = r-o· SCOPE OF WORK: MANUFACTURE & INSTALL ONE (1) NEW FRONT LIT / BACK LIT CHANNEL LETTER MOUNTED FLUSH TO WALL El SIMULATED NIGHTTIME PHOTO OVERLAY SCALE: 1;4· = 1'-o• PHOTO OVERLAYS AND RENDERINGS ARE FOR PLACEMENT REFERENCE ONLY AND MAY NOT BE TO SCALE. PLEASE REFER TO THE PRODUCTION PAGE WITH MEASUREMENT CALL OUTS FOR THE SPECIFIC SIZE/SCALE OF YOUR SIGN. NIGHTTIME VIEW SHOWN MAY NOT REFLECT REAL LIFE LIGHTING CONDITIONS. THESE PRINTS ANO THE DESIGNS HEREIN ARE THE PROPERTY OF SAN DIEGO ELEC!lllC SIGN, INC.. ANO THE SIGNS OR DESIGNS HEREIN MAY NOT BE REPLICATED. DUPLICATED OR COPIED IN ANY MANNER, ANO MAY NOT BE USEO FOR THE PURPOSE OF OBTAINING COMPETITOR BIOS. UPON OBTAINING A FULLY EXECUTED OISPlAY PURCHASE AGREEMENT AND DEPOSIT. SAN DIEGO ELEC!lllC SIGN. INC.. MAY ELECT AT THEIR DISCRETION TO TRANSFER THE DESIGNS HEREIN TO THE CLIENT. Ill ~an Diego £/ect,tic .s'i9.n- lNSTALLATION• DESIGN· FABRICATION CA UC •750379 Cllent: ACE TUTORING Job: NEW STOREFRONT SIGN Address: 7040 AVENIDA ENCINTAS #101 CARLSBAD, CA 92011 Salesperson: CHRISTY BALLARD Date: 08/23/16 Drawing#:A Revisions: Rl: Reduced sign to 17"; added suite measurements R2: Reduced sign to 14· and added back lit R3: Revised frontage and reduced signage R4: Revised square footage ARTTIME DATE REVISION NUMBER 1.00 08/01/16 PRELIMINARY PRINTS 1.00 08/08/16 PRELIMINARY PRINTS RI 3.00 08/23/16 PERMIT PRINTS R1 1.00 08/29/16 PERMIT PRINTS R2 .50 09/15/16 PERMIT PRINTS R3 .50 09/16/16 PERMIT PRINTS R4 ACCIE irmCO>JruINKG:r Provldlng electrical to the sign location ls t he responslblllty of others. San Diego Electric Slgn, Inc. Does NOT provide electrical to the sign location. CUSTOMER APPROVAL OF DESIGNS: Client Signature Date Landlord Signature Date PAGE 4 OF 6 ACETUTO ~NG-0 INTERNALLY ILLUMINATED OVERHANG SIGN SCALE: 3/4" • 1'-0" QUANTITY: ONE (1) SQ FT: 12.03 SQ FT NOTE: MANUFACTURING SURVEY NEEDED PRIOR TO PRODUCTION CD FRONT LIT / BACK LIT LETTERS FACES: □ .m ··wHITE. ACRYLIC ■ . 171 • "RED" 2793 ACRYLIC LETTERS MOUNTED TO "WHITE" ACRYLIC FACES TRIMCAP: □ 3/4" "WHITE" RETURNS: ■ .040" ALUMINUM, s· DEEP. PRE-PAINTED "BLACK. LETTER BACKS: .17T "CLEAR" LEXAN ILLUMINATION: □ "WHITE" 7000K PSF MIDDLEWEIGHT LEDs MOUNTING: MOUNTED 15/8" OFF THE WALL Ill ' • INSTALLATION· DESIGN• FABRICATION CA LIC •750379 Client: ACE TUTORING Job: NEW STOREFRONT SIGN Address: 7040 AVENIDA ENCINTAS #101 CARLSBAD, CA 92011 Salesperson: CHRISTY BALLARD Date: 08/23/16 Drawing#:A Revisions: R1: Reduced sign to 17"; added suite measurements R2: Reduced sign to 14" and added back lit R3: Revised frontage and reduced signage R4: Revised square footage ART TIME DATE REVISION NUMBER 1.00 08/01/16 PRELIMINARY PRINTS 1.00 08/0B/16 PRELIMINARY PRINTS R1 3.00 0B/23/16 PERMIT PRINTS R1 1.00 OB/29/16 PERMIT PRINTS R2 .50 09/15/16 PERMIT PRINTS R3 .50 09/16/16 PERMIT PRINTS R4 AClE murJr(Q)JruIN<G Providing electrical to the sign location ls the responslbillty of others. San Diego Electric Sign, Inc. Does NOT provide electrical to the sign location. CUSTOMER APPROVAL OF DESIGNS: Client Signature Date Landlord Signature Date PAGE 5 OF 6 30" 94" 14"IACE TUTO ~NG ·~ INTERNALLY ILLUMINATED OVERHANG SIGN SCALE: 3/4" = 1'-0" QUANTITY : ONE (1) SQ FT: 12.03 SQ FT NOTE: MANUFACTURING SURVEY NEEDED PRIORTO PRODUCTION SIGN SQUARE FOOTAGE CALCULATIONS SIGN LABEL ALLOWABLE PROPOSED ALLOWABLE PROPOSED ALLOWABLE PROPOSED TOTAL (PRINTS) HEIGHT HEIGHT LENGTH LENGTH SQ.FOOTAGE SQ. FOOTAGE SQUARE FOOTAGE A N/A 14" N/A 124" 12.075 12.03 12.03 5· 1 5/8" .040" ALUMINUM _____ ~ RETURNS THREADED STUDS (MIN 3 PER GRAPHIC) ~-+--+-+~..,.,..,1------MOUNTED INTO WALL W / CONSTRUCTION GRADE SILICONE ---INPUT: AC100-240V 50/60Hz .17r ACRYLIC FACE ---1 , ____ U/LAPPROVEO ~ ~ I ~ =fi=. • DISCONNECT SWITCH ~,,.OlfUJJ71/. ~ 1 OUTPUT: 12V LEOs ----lf-----i : ·f J REMOTECLASS 2 POWER SUPPLY .17T "CLEAR" LEXAN II \,II l HI METAL WIREWAY ·' · CONDUIT 1/4" WEEP HOLES ____ __J WALL: i------MATERIAL: PARAPET DEPTH: 10· 1 5/8" ALUMINUM _______ __J TUBE SPACERS TITLE 24 THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND 2013 CALIFORNIA BUILDING & ELECTRICAL CODE, THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. ALL WALL PENETRATIONS TO BE SEALED WITH UL LISTED SILICONE SEALANT. @umo FABRICATED WITH ALL UL APPROVED COMPONENTS II INSTALLATION• DESIGN• FABRICATION CA LIC 9750379 Client: ACE TUTORING Job: NEW STOREFRONT SIGN Address: 7040 AVENIDA ENCINTAS #101 CARLSBAD, CA 92011 Salesperson: CHRISTY BALLARD Date: 08/23/16 Drawing#:A Revisions: Rl : Reduced sign to 17"; added sulte measurements R2: Reduced sign to 14" and added baclc lit R3 : Revised frontage and reduced signage R4: Revlsed square footage ARTTIME DATE REVISION NUMBER 1.00 08/01/16 PRELIMINARY PRINTS 1.00 08/08/16 PRELIMINARY PRINTS R1 3.00 08/23/16 PERMIT PRINTS Rl 1.00 08/29/16 PERMIT PRINTS R2 .50 09/15/16 PERMIT PRINTS R3 .50 09/16/16 PERMIT PRINTS R4 ACCJE 1TTUJ1r(O)OO[NCGi Providing electrical to the sign location is the responslbllity of others. San Diego Electric Sign, Inc. Does NOT provide electrical to the sign location. CUSTOMER APPROVAL OF DESIGNS: Client Signature Date Landlord Signature Date PAGE 6 OF 6