Loading...
HomeMy WebLinkAboutPS 2017-0070; PEARLMAN CLINIC; Sign Permits/Programs (PS){"city of Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.car1sbadca.gov V&J-i-«>11-01-tq PLANNING APPL~ATION # PS ion-e>o?t) REC'D BY ---1.~~t'(..c.....,...~~-------- DATE :t-1;-h SIGN FEE iii fi'.3 - SIGN PROGRAM FEE _______ _ RECEIPT NO. ___________ _ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: 'fbµN:l\,,I c.L1 LIi L Address of Project: jc,\05 C\'\\,t,e, \2,:f'P:{.e!-9,;,f< :lfZII • CJ\£:lSC,'A)'.l C:..\I', cp,o:f'l Assessor Parcel Number: ______________________ _ Related Planning Case Number(S): ___________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) (b) Commercial (e) Service Station (h) (c) Office/Industrial (f) Prof. Care (i) SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Theater Gov't/Church/School Public Park U) Produce Stand (k) Nursery (I) P-U/OS Zone Yes □ NoD Specific Plan Number ____ _ VILLAGE REVIEW AREA (If ves. please complete information on page 3) SOUTH CARLSBAD COASTAL REVIEW AREA YesB Yes Noa No SIGN ORDINANCE: Yes □ No □ COASTALZONE: Yes □ No □ P-11 Page1of4 Rev. 10/13 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** -' Wall -'\ ~·2.fo~~➔-~ ~,q:1, --• 2, I ll ~ Suspended/Projecting Directional Canopy Freestanding•• (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale .. Banner Interim ••Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility Issues. Additional information must supplement this appllcatlon showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev.10/13 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I ' PIL 1 Si.pt ~e Requirament Shaw buildin1/s I I I I I I j Show sedJac:ks from all curbs '-:---l --- I I ' I I Show all property lines ' PIL I : ! I curb line i -------------- • • S;ptVmbwty Street Nam.e(s) (i) I ' North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: _________ sq. ft. Total Building Street Frontage: 1J,,' linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 10/13 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE\ NAME (PRINT OR TYPE\ _:,LL /rrfJ~ N'l\l\){;e --1::,-; ¾ 1eile= MAILING ADDRESS MAILING ADDRESS C.i L. ~ I ."" l?o OJv\10\.J ,\ts ~~tu'llq,'{ P11~t1'(',sorr11(b, 2, '-f Gf'6 '?c,Lt, '\)Q.-l '-lB w ::fl (a CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE ~L. 'flf'1-~11t tl ~111 i OOd'\. ( '9-711 )i-u.- -0301 SIN 'OlW:fO CJI q '2.,t'2, 'l,, ~ 1cy '{2-"'I -'{'2:P<-::, I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. SW rtr-rw \bn /2L :::i 11 lr::i , si&::iATUVE ~ SIGNATURE DATE DATE F PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy too/a Entry APPROVED: Planner: l:2'F:::: Date: '1(13/(1 P-11 Page 4 of 4 Rev. 10/13 (©))JLL Via Email perlmanronald@gmail.com June 19, 2017 Mr. Ron Perlman Monro Capital Inc. 3900 5th Ave. Ste. 260 San Diego, CA 92130 Re: Forum Carlsbad, Carlsbad, CA Perlman Clinic, Space # 211 Dear Ron Perlman, Tenant Coordination/Retail Jones Lang LaSalle Americas, Inc. 1125 Sanctuary Parkway, Suite 170, Alpharetta, Georgia 30009 tel +678 226 5301 fax 678 226 5037 Enclosed you will find one copy of the reviewed signage shop drawing and the tenant review form. Any deficient items are noted. The sign is approved as noted. If you have any questions, please do not hesitate to contact me at (678) 226-5301 or e-mail Ann.Nance@am.jll.com. Kind Regards, f2tm1[Mcl Ann Nance, LEED AP Vice President, Tenant Coordination/Retail Jones Lang LaSalle Americas, Inc. Enclosure cc: Rodrigo Sada, Forum Carlsbad Justina McClellan, JLL Art Papaceno, JLL VA ELECTRIC GENERAL ELECTRICAL SERVICES & ILLUMINATED SIGNS Project Submittal Perlman Clinic Front Illuminated Signage PERLMAN CLINIC, INC. 1905 Calle Barcelona #211 , Carlsbad CA 92009 Client Mitchell Perlman Monro Capital, Vice President 3900 5th Ave, Suite 260 San Diego, CA 92103 ©: (858) 692 0098 (0): (619) 255 5860 (F): (619) 546 9562 CONTRACTOR LICENSE# 705159 TEL: (619) 274 -1326 (619) 870 -9280 Pe:>/~t1-DJ'-f1 SIGN PERMIT NO. PS 2-<:> 11 :.. ·'D0 7 o · Legal Description APN# Pl.ANNING BUILDING MAP 4/PARCEL 255-012-04 Contractor: Vidal Angel (Owner) APPROVED BY , ellZ Mobile: ( 619) 27 4-1326, ( 619) 870-9280 vaelectric85@yahoo.com INDEX Page 1 -Site Map/Vicinity Map Page 2 -Elevation for proposed signage Page 3 -Channel Letters Specs Page 4 -Assembling and Mounting Details Page 5 -Electrical Details Page 6 -Sign Visual EMAIL: vaelectric85@yahoo.com Address: DATE ' , fr~ /J_,, - June 22th, 2017 750 My Way San Diego, CA 92154 SITE MAP FOR PERLMAN CLINIC, INC. 1905 Calle Barcelona #211 , Carlsbad CA 92009 jen View Rd .-.. ~ ::: ,.> ,.;., ::t r--~ (!) i'5 i5 (l) -, ~ Q. ci C) ~~ <:;' " Q. Q.. 0 ~G') "' ... -II) 3::, "' 0.. ::l, ff) g,: i3 ~~ -ff> .. ::, ... ff> (/) Pei MatA uapJe~ -< 0 .& ft> 0 "'a (II ... .. o m ~~ o~ .. ~ g, !i':o -i5. II) =r "" CD ~ '° 0 UI ~ • m • ;; • 0 :, • .... Jalle 8 o :::o <:Jr,-. ~ a, ff> '-et, gl: ~ O,t-. i ~ ~ Q ::, o'~ 20 38 03 "' ft> ;-a 0" -g_ e. o> ~ ii" 0 Cl) :i Og 0.. al ... a, II) &_ia ~3 ~ 0 Q> 5 0 s. u Q) '-3' ~r ~ g-s e UJ. co .J~ ZC> -c» -4> ct C: :::) ~~g. q ff> 0.. -Cl) ft> G ,•--------------.... 0 "C "'m ~o Ill 0 a, !a ... ft> .. --"' -a. II) e 0 QO~ ~=r II> II> (I) 0 r-0 II> ::: 0) l'I> ..... ff> a, ff> Cl) ::, () ~ (l) a; ~ (") <t) 0 ::I CJ • • -&' -------·------, (") -----·· --·-·------ t • ' ' ::c 0. ~ ~ff> ioo ' I 0 ::, <• Q) Q. 3 QI I i:, 0. , S" Cl> ,~ 10 ~ ,, 0 C 0 In (/) en ~ --!? Qo 1J z "' leati ou,we:) 13 ED VICINITY MAP VA ELECTRIC GENERAL ELECTRICAL SERVICES & ILLUMINATED SIGNS CONTRACTOR LICENSE# 705159 Project Submittal: Perlman Clinic Front Illuminated Signage Client: Mitchell Perlman Cil '•r::_•, (1) OJ ~ () ~ g O> I . \ () : cu ~.... -:::: •, ro •, d:: SUBMITTAL DATE 06/22/17 PRESENTED BY Vidal Angel 1 ltOlli 2ND FLOOR ~ ,,i::::.::· ·:~<:) \:--.. ../:/ ....... ,., ....... .. ........... &co.,Na.,.,..d ~·:.l r==L.:d I 0 Kl" 100' 20f1 Not for Scale STREET LEVEL SITE PLAN REVISION DATE :;) '-- :2 ... ; '-- :3"'; '-- ,'4"; '-- PROPOSED SIGNAGE LOCATION COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY. THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY. COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE. THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF SIGN PRODUCTION. IT CANNOT BE REPRODUCED, COPIED OR EXHIBITED IN WHOLE OR PART, WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM SIGN PRODUCTION. APPROVAL DATE PROJECT DUE DATE --- I ~ Page 1 of 6 ELEVATION FOR PROPOSED SIGNAGE t VA ELECTRIC GENERAL ELECTRICAL SERVICES & ILLUMINATED SIGNS CONTRACTOR LICENSE# 705159 46 ft Project Submittal: Perlman Clinic Front Illuminated Signage Client: Mitchell Perlman SUBMITTAL DATE 06/22/17 PRESENTED BY Vidal Angel REVISION DATE tl) '-- :2'; '-- :3'; '-- :4'; '-- @ Total Sq/Ft Area= 25.93 Sq/Ft COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY. THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY. COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE. THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF SIGN PRODUCTION. IT CANNOT BE REPRODUCED, COPIED OR EXHIBITED IN WHOLE OR PART, WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM SIGN PRODUCTION. APPROVAL DATE PROJECT DUE DATE Page 2 of 6 FRONT ILLUMINATED CHANNEL LETTERS _J _J <( ~ 1·2· in r-- T""" Limited Top Area Scale: 1" = 15" NOTE S: Limited Down Area FRONT ILLUMINATED AND BACK LIT LETTERS {PERLMAN) 2" depth letters fabricated with 1 /2" clear acrylic face, laminated with translucent vinyl color PMS 346 C. With return of .040" aluminum painted color PMS 346 C on the outside; inside paint color white. 1 / 4" clear acrylic back prevents birds an other animals from nesting inside the sign. Back/Front Illuminated w/ low voltage white LED's. This sign is intended to be installed in accordance with the requirements of article 600 of the National Electrical code and/or other applicable local codes. This includes proper grounding and bonding of sign. SPECS: Letters and symbols: Front Illuminated and Back-Lit. VA ELECTRIC GENERAL ELECTRICAL SERVICES & ILLUMINATED SIGNS CONTRACTOR LICENSE # 705159 Project Submittal: Perlman Clinic Front Illuminated Signage Client: Mitchell Perlman The top points of letter "i" cannot be illuminated because there is no enough space to p lace an LED module. -------+---14.82' - 1" PVC thick NO ILLUMINATED. Painted color PMS 425C flush to wall primary ana uraent car .1m1ted Area FRONT ILLUMINATED AND BACK LIT LETTERS {CLINIC) 2" depth letters fabricated with 1 /2" clear acrylic face, laminated with translucent vinyl color PMS 425 C. With return of .040" aluminum pointed color PMS 425 C on the outside; inside point color white. 1 /4" clear acrylic bock prevents birds on other animals from nesting inside the sign. Bock/Front Illuminated w/ low voltage white LED's. BACK/FRONT ILLUMINATED SYMBOLS{++) 2" depth letters fabricated with 1 /2" clear acrylic face, laminated with translucent vinyl color PMS 580 C and PMS 346 C. With return of .040" aluminum pointed color PMS 580 C and PMS 346 C o n the outside, inside paint color white. l / 4" clear acrylic back prevents birds an other animals fromnesting inside the sign. Back/Front Illuminated w/ low voltage white LED's. Total Sq/Ft Area= 25.93 Sq/Ft SUBMITTAL DATE 06/22/17 PRESENTED BY Vidal Angel REVISION DATE ,-1\ \ .. _, t2 '; '-- /3'; '-- t4'; '-- COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY. THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY. COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE. THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF SIGN PRODUCTION. IT CANNOT BE REPRODUCED. COPIED OR EXHIBITED IN WHOLE OR PART. WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM SIGN PRODUCTION. APPROVAL DATE PROJECT DUE DATE Page 3 of 6 , FRONT ILLUMINATED CHANNEL LETTERS . 040" thick aluminum channel letter, w ith 2" deep return, painted color Pantone 346 C. ~...--------Inside paint, color white. ~ \ LEDs. LETTER ASSEMBLING scale: 2 ½" = 12" ~ VA ELECTRIC GENERAL ELECTRICAL SERVICES & ILLUMINATED SIGNS CONTRACTOR LICENSE# 705159 1 /2" thick clear acrylic face laminated with translucent vinyl color PMS 346 C. Project Submittal: Perlman Clinic Front Illuminated Signage Client: Mitchell Perlman 1 /2" 1 /4" 1 /4" 1 /4" routed tab. .040" thick alum. return ~---1 /8" thick angles, size 1 ½" x 1 ½" Countersunk screws to mount angles and acrylic backers. ,.. . -" . ,, ,4.,::::,-------=+---l" stainless steel spacer ______ ...___ Mounted to wall with SS bolts and anchor for drywall. 1 /8" thick angles, ~---size 1 ½" x 1 ½" s 0 c.o 1 /8" thick "U" channel, size 3" x 3 ½". Painted same color as wall. .::Jrovide color. Countersunk screws Low voltage ---+-+-'----... white LED modules L Countersunk screws to mount angles and "U" channel to wa ll. to mount a crylic faces and backers Note: 1. Penetrations to the Bu ilding should be sealed in a watertight manner 2. Illuminated letters should be "UL" rate labels should not be visible to he public. SUBMITTAL DATE 06/22/17 PRESENTED BY Vidal Angel REVISION DATE /l'; '-- {2'; '-- {i '; '-- /4'; '-- _J _J <( ~ >-a:::: 0 ......... __ SIDE VIEW scale: 2" = 12" COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY. THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY. COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE. THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF SIGN PRODUCTION. IT CANNOT BE REPRODUCED. COPIED OR EXHIBITED IN WHOLE OR PART, WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM SIGN PRODUCTION. Mounted to wall with SS bolts and anchor for dryw all. APPROVAL DATE PROJECT DUE DATE Page 4 of 6 !- FRONT ILLUMINATED CHANNEL LETTERS i--------------------------1 -r;i -----OUTSIDE VIEW ----- ~ = \ ~ = • I -:sITl u ---------------------------------------------, I I I I I I I I ----------------------------------------------------------------------------------------------I A I LED Modules: Elevation (j) scale: 1 ¼" = 12" @ LED Module = 0.48w each In= 12v Total LEDs = 77 modules Total Watts = 36.96 watts Power Supply In= 110-220V, Out= 12V. 1 power supply of 60W. @ G) G]) (j) (j) SIDE VIEW ..------1 /8" thic~ an~l~,s, 1 /8" thick "U" channel, size 1 ½ x 1 ½ size 3 .. x 3 ½". Painted _J _J <( ~ >-Cl::'. 0 I--+----3" -------+< -I " l 1lil I 1 1 s ~ --jj ! II ~ II J L Countersunk screws to mount angles and "U" channel to wa ll. same color as wall. Please provide color Section scale: ¾" = 12" Section ......_ __ Stainless Steel bolts and scale: 6" = 12" anchor for drywall. VA ELECTRIC Project Submittal: Perlman Clinic Front Illuminated Signage SUBMITTAL DATE 06/22/17 PRESENTED BY Vidal Angel GENERAL ELECTRICAL SERVICES & ILLUMINATED SIGNS CONTRACTOR LICENSE# 705159 Client: Mitchell Perlman ® G)@ REVISION DATE :;; ._,_ :2'; ._,_ .. '3'; ._,_ :~i'; ._,_ (j) @ ® INSIDE VIEW Internal Cable UF-B W/G wire for outdoor use 600-Volt maxi m um for w et or d ry locations up to 90°C or 194°F Copper conductor UV a nd sunlight-resistant COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY. THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY. COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE. THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF SIGN PRODUCTION. IT CANNOT BE REPRODUCED, COPIED OR EXHIBITED IN WHOLE OR PART, WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM SIGN PRODUCTION. ® Note: Power ·supply I I I I ... -----.. , ,, ... ----~_,-.-~ I • ~~ ... l,. ' '.1A~S --II ' .. __ "'. __ ~ l ....i,, ...... 1. Penetrations to the Building should be sealed in a watertight manner APPROVAL DATE PROJECT DUE DATE Page 5 of 6 SIGN VISUAL ' Day VA ELECTRIC GENERAL ELECTRICAL SERVICES & ILLUMINATED SIGNS CONTRACTOR LICENSE# 705159 Project Submittal: Perlman Clinic Front Illuminated Signage Client: Mitchell Perlman SUBMITTAL DATE 06/22/17 PRESENTED BY Vidal Angel Night REVISION DATE :1; '--:2; '-- :3) '-- :4; '-- Note: 1. Sign to be on timer and must be on during property hours COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTATION PURPOSES ONLY. THEY MAY NOT MATCH YOUR FINISHED PRODUCT PERFECTLY. COLOR CALL-OUTS ARE FOR A MATCH AS CLOSE AS POSSIBLE. THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF SIGN PRODUCTION. IT CANNOT BE REPRODUCED. COPIED OR EXHIBITED IN WHOLE OR PART. WITHOUT FIRST OBTAINING WRITTEN CONSENT FROM SIGN PRODUCTION. APPROVAL DATE PROJECT DUE DATE Page 6 of 6