Loading...
HomeMy WebLinkAboutPS 2017-0093; LAIRD R&F PRODUCTS; Sign Permits/Programs (PS)( City of Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov "D SV .:2.0 l, i -0 :2.1 ~ PLANNING APPL,ICATION # PS '2.0 I 7 -0093 REC'DBY~~; ~ DATE IOli( ~ ~:~~ ~~~GRA E ___ --_____ _ RECEIPT NO. ___________ _ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: Laird R&F Products Address of Project: 2091 Rutherford Road Assessor Parcel Number: _.=2:..:1=.2·...:1=.20::.·-=2=-5-0..:..:.0 ________________ _ Related Planning Case Number(S): ___________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) (b) Commercial (e) Service Station (h) (c) Office/Industrial (f) Prof. Care (i) SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Theater Gov't/Church/School Public Park 0) Produce Stand (k) Nursery (I) P-U/OS Zone YesO NoO Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes. please complete information on page 3) YesO YesO NoQI No@ SOUTH CARLSBAD COASTAL REVIEW AREA SIGN ORDINANCE: Yes@ No□ COASTALZONE: Yes □ No@ P-11 Page 1 of4 Rev. 10/13 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended/Projecting ,, Directional Canopy ' . . .. .,._, .. Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ------- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** Wall 1 33SF 36" Suspended/Projecting Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction•• For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and vlslblllty Issues. Additional Information must supplement this application showing how the proposed slgnage will not encroach Into the public right- of-way or present a traffic hazard. Page 3 of 4 Illustrates an example for what would be required for such proposed signs • • P-11 Page 2 ol 4 Rev. 10/13 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I ' P/L / Sia,ht Dist~e Requirement Show building ls t ' " i . ' I I ' Show setbacks from all curbs '---l . -- ' I I ' j I Show all property lines 1 P/L I :/ I curb line i -------------- • • Si,iht Vinmlity Street Name(s) (i) I ' North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: ______ 64_1_1~4-sq. ft. Total Building Street Frontage: _______ 4_o_o_ linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. fl.): sq. ft. Remaining Sign Allowance at Present: -------~ sq. ft. Proposed Signage (sq. ft.): 33 sq. ft. Remaining Sign Allowance After Proposed Sign: ________ sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 ol 4 Rev. 10/13 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE\ NAME /PRINT OR TYPE\ DCT Industrial, Inc. Stan ldeker MAILING ADDRESS MAILING ADDRESS PO Box 173382 4139 Avenida de la Plata CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Denver co 80217 303.597.2400 Carlsbad CA 92056 858.735.4080 I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. /Jr, .. ;1? ~>el/ October 06, 2017 <SL-I J I October 05, 2017 SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at comer 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry ~~""---APPROVED: Planner: ~~~=:~I!...!!~~-==;'-=•~~-----Date: /O {t.J, /17 P-11 Page 4 of 4 Rev. 10/13 I I I I I I I I J I '!.(''-r-@ 1 I J I .-l I £-t I I I I I I I -;~I -I I -t • : --!-..---l -t I 7 I J I -+ I , I J I -I I -=t .. ). .. I :::t I ,..f' □ - PARKING SPACE TABLE 1"lf't OF 51"ACI JOTAI. £'A"" ~tNGIIID 7CM "''" 2091 Rutherford Road JO' o· p-,.... SCALE: \ :::0 C -I :r: fT1 :::0 ..., 0 ;o CJ \ ) 8 ,.. to' I 1" = 30' BUILDING Site Plan Address: 2091 Rutherford Road Carlsbad, CA 92008 Project Title: Laird Scope of Work: (1) Illuminated Wall Sign 33SF Owner's Information: Laird R&F Products 2091 Rutherford Road Carlsbad, CA 92008 Assessor's Parcel#: 212-120-25-00 Legal Description: Par A Lot 51 Map 11811 COASTA L SIGNAGE +W YFINDING MAKE A FIRST IMPRESSION THAT L.ASTS 4139 A'IENIO.I DE LA ,uu OCUNSIDC, CA 92056 tH 760 744.2'27 ALL IDEAS. PLANS DR ARRANGEMENTS INDICATED ON THIS DRAWING ARE COPYRIGHTED AND OWNED BY COASTAL SIGNAGE• - AND SHALL NOT BE REPRODUCED. USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION WITHOUT WRITTEN PERMISSION Of COASTAL SIGNAGE• J DRAWINGS AJ!f FOR ESTHEllC REFEREHCE PURPOSE ONl Y AND THE DIMENSIONS ARE NOT TO BE TAK£HAS FACT SALES: CS DESIGN: SHEILA GRAN T PROJECT MANAGER: AD LAIRD 2091 Rutherford Rd Carlsbad CA This drawing has been reviewed and is ... 0 Approved Without Exception 0 Approved As Noted 0 To Be Revised and Resubmitted By ______ _ Date _____ _ Date: 07/03/2017 6, Rev 1: 7/10/2017 Rev 2: 7/20/2017 Rev 3: 7/20/2017 11.0 JOB NUMBER: 30176 FIELD MEASUREMENT OF MOUNTING AREA REQUIRED -CONFIRM SIZE OF PROPOSED LOGO MAKE A FIRST IMPRESSION THAT LASTS 41J9 AYENIDl 0£ LA PLATA OCUNSIOE, CA 920!.S fll 760 744 2927 All IDEAS, PLANS OR ARRANGEMENTS INDICATED ON THIS DRAWING ARE COPYRIGHTED ANO OWNED BY COASTAL SIGNAGE• 1• ANO SHAll NOi BE REPRODUCED USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION WITHOUT WRITTEN PERMISSION OF COASTAL SIGNAGE• • DRAWINGS ARE FOR ESlliETIC REFERENCE PURPOSE ONLY AND lliE DIMENSIONS ARE NOT 10 BE !AKEN AS FACT SALES: CS DESIGN: SHEIL A GRANT PROJ ECT MANAGER: AD LAIRD 2091 Rutherford Rd Carlsbad CA Sign Type 2 Exterior Wall Logo Photo Placement This drawing has been reviewed and is ... D Approved Without Exception D Approved As Noted D To Be ReVtSed and Resubmilled By ________ _ Date _______ _ Date: 07/03/2017 D Rev 1: 7/10/2017 Rev 2: 7/20/2017 Rev 3: 7/20/2017 4.0 JOB NUMBER: 30176 r 3' L MAIO< PMSfflC HALO-LIT EXTERIOR LOGO ALUMINUM CONSTRUCTION 5" DEEP PAINTED TWO COLORS • FRONT VIEW 33 SF 11' "TM" TO BE .125" THICK ALUMINUM PLATE STUD MOUNTED FLUSH MOUNTING MOUNTED TO EXTERIOR OF BUILDING STAND-OFFS AS REQUIRED F1ELD MEASUREMENT OF MOUNTING AREA REQUIRED -CONFIRM SIZE OF PROPOSED LOGO QUANTITY ONE (1) WALL LOGO REQUIRED SCALE 3/4"=1-0" 5.00" TM SIDE VIEW HALO LIT LOGO SIMULATED NIGHT ILLUMINATED COASTAL SIGNRGE +WAYFINDI G MAKE A FIRST IMPRESSION THAT LASTS 41lt AYENIDA DE U PUU OCEANSIDE, CA '20S6 TEL. 760 744.2927 ALL IDEAS. PLANS DR ARRANGEMENTS INDICATED ON THIS DRAWING ARE COPYRIGHTED AND OWNED BY COASTAL SIGNAGE • • AND SHALL NOT BE REPRODUCED USED BY OR DISCLOSED TO ANY PERSON. FIRM OR CORPORATION WITHOUT WRITTEN PERMISSION OF COASTAL SIGNAGE• • DRAWINGS ARE FOIi ESIHETIC REFERENCE PURPOSE ONLY AND THE DIMENSIONS ARE NOT 10 BE TAKEN AS FACI SALES: CS DESIGN: SHEILA GRANT PROJECT MANAGER: AD LAIRD 2091 Rutherford Rd Carlsbad CA Sign Type 2 Exterior Wall Logo This drawing has been reviewed and is ... D Approved Without Exception D Approved As Noted D To Be Revised and Resubmitted By _______ _ Date ______ _ Date: 07/03/2017 L::,_ Rev 1: 7/10/2017 Rev 2: 7/20/2017 Rev 3: 7/20/2017 3.0 JOB NUMBER: 30176 Appropriate Spacers For Halo Illumination Lead Wire With Connector Plugs Light Emitting Diode Unit (typ.) .040 alum. --- ◄ Direction Of Led Light Beam Fascia ---Clear Lexan Backing 4" x #10 Tex Screws w/Anchors (Min. 4 ea.) ---------Watertight Exterior Raceway Power Supply f----+-------J-box, 120vac Primary Channel Letter Construction Detail (typical) 3', DEEP INTERNALLY ILLUMINATED ALUMINUM LETTERS UL Listed Disconnect switch weatherproof (Ref: NEC 600-2)