Loading...
HomeMy WebLinkAboutPS 2018-0012; OLD NAVY OUTLET KIDS AND BABY; Sign Permits/Programs (PS)Ccicyof Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov 0~1J Z..-, l 1S ... 00 Z,. '1 PLANNING APPLICATION# f 5 '2-D \ Y -O O 11- REC'D BY \>t~ .S..~ DATE "L-f.c..,, f..t t SIGN FEE J ~ S" SIGN PROGRAM FEE _______ _ RECEIPT NO. __________ _ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed slgn(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: Old Navy Outlet Kids & Baby Address of Project: 5600 Paseo Del Norte #112A, Carlsbad, CA 92008 Assessor Parcel Number: 211-022-22-02 ----------------------Related Planning Case Number(S): __________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) Theater (b) Commercial (e) Service Station (h) Gov't/Church/School 0) Produce Stand (k) Nursery (c) Office/Industrial (f) Prof. Care (i) Public Park (I} P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes□ NoD Specific Plan Number ____ _ VILLAGE REVIEW AREA (ff yes, please complete information on page 3) YesB SOUTH CARLSBAD COASTAL REVIEW AREA Yes SIGN ORDINANCE: Yes □ No□ COASTALZONE: Yes □ No □ P-11 Page 1 of 4 Noa No Rev. 10/13 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date _____ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Pole** Monument** Wall 1 55.56 SF 18.75" Suspended/Projecting 1 3SF 12" Directional Canopy Freestanding** (Project Identity} Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction- For Sale** Banner Interim -Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility Issues. Additional information must supplement this application showing how the proposed slgnage will not encroach Into the public right- of-way or present a traffic hazard. Page 3 of 4 Illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 10/13 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I I P/L / Sipt ;· Reqainlment ~ baildina/s I I I ; I '.---l ~ setbacks from all curbs --- I I I I I I ~ all pnperty lines I P/L : I :/ I curb line i ----------~--- Sipt Vllibility I StreetN-(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: -------~ sq. ft. Total Building Street Frontage: 38 linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): 55.5 sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: sq. ft. -------- Tot a I Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 10/13 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE} NAME (PRINT OR TYPE} Simon Premium Outlets Stan ldeker MAILING ADDRESS MAILING ADDRESS PO Box 6210 8535 Arjons Drive CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Indianapolis IN 46206 760-804-9044 San Diego CA 92126 858.549.1655 I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. See Attached Feb.14,2018 ~ .J£_i~ February 14, 2018 SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at comer 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data '=Kry APPROVED: Planner: c:::: ?{ ( '7 Date: ?Ju/ti P-11 Page4 of4 Rev. 10/13 Date: To: Company: Email: Tenant: CC: <><> CARLSBAD PREMIUM OUTLETS. A S IMON CENT ER SIGN APPROVAL February 7, 2018 Ray Fung Gap ray fung@gap.com Old Navy Kids & Baby, Suite #112A rhoyer@waltonsignage.com Carlsbad Premium Outlets From: Judy Walton Senior Tenant Sign Manager Premium Outlets jwalton@simon.com <X> SIMON PREMIUM OUTLETS THIS NOTICE, TOGETHER WITH THE ATTACHED, MARKED-UP SIGN DRAWINGS, CONFIRMS LANDLORD'S WRITTEN APPROVAL (AS NOTED) OF THE SIGN DRAWINGS AND ELEVATION FOR THE STOREFRONT & BLADE SIGN FOR "OLD NAVY OUTLET KIDS & BABY", SUITE #112A, AT CARLSBAD PREMIUM OUTLETS. Tenant is authorized to proceed with installation of its signs in accordance with the drawings, and as otherwise noted by Landlord. Tenant or its contractor must field verify mounting height and special mounting conditions with onsite management team of all signage included in this approval. Tenant's sign contractor must make an appointment with Landlord's onsite management team (760) 804-9044 at least 48 hours before arriving to install the signs to confirm the actual location of all signs on the building. The contractor will be required to sign all necessary forms and provide required Certificate of Insurance and a copy of Tenant's sign permit at this meeting. Be prepared with plastic or tarps and painter's tape to protect and cover all surfaces from dust and debris. NO duct tape or blowers allowed. All signs shall be installed prior to Tenant opening at a place or places designated by landlord. Tenant is responsible for their sign installer to provide watertight installations from both the inside and exterior side of the wall penetrations and proper cleanup of all surfaces upon completion. Tenant's installer must provide labeled photos of proper sealing from inside and outside of sign install, making sure sleeves are shown where needed at eifs facades, to LL at time of install. Tenant shall also be responsible for any and all costs associated with illuminating their sign(s). Keep in mind, work needed may include an electrician if circuit is not near location. Signs MUST be lit for opening. Finally, Tenant and its contractor are hereby notified that any work, which involves cutting into or penetrating the existing roof structure and/or roofing material must be performed by Landlord's Roofing Contractor at Tenant's Expense. Tenant shall be liable for all damage resulting from unauthorized roof penetrations and their consequent effect on the integrity of the roof and the warranties offered by the installer and manufacturer. Therefore, if it is determined that roof penetration is likely required, Landlord must be notified in advance so that scheduling of its roof contractor may be available. If penetrations/raceway not sealed properly by LL's roofer, then Landlord will correct on Tenant's behalf, and Tenant will reimburse Landlord for the cost incurred. Note: Landlord's approval herein means Tenant has met Landlord's sign requirements; it does not mean that Tenant has complied with, and Tenant continues to bear full responsibility for compliance with, any regulatory, code and permit requirements related to Tenant's signage. 5620 Paseo del Norte #100. Carlsbad. CA 92008 • (760) 804-9044 .; .t Addtess: Project Title: Scope of Work: Owner's Information: Legal Description: 5600 Paseo Del Norte Suite 112A Old Navy Outlet Kids & Baby (1) Illuminated Wall Sign 55.5 SF Simon Premium Outlets PO Box 6210 Indianapolis, IN 46206 Assessor's Parcel#: 211-022-22-02 Lot 2 Map 013357 (1) Non-Illuminated Blade Sign 3 SF ------------.-~-~--~,-, r----;,o;c, :--,-u·----=~ ·-~ · .. -. . \ \ I. ____ @tL _______ @)U _________ @) _~_@lJ ________ (yLi, _______ (s ::::::::::::-------..~ ;:;------------±~a_r~.sbfH'=~~".'~-~~.;:rt~~!~~':t ______ @_o~--------@------------- \ @ \_ ;;7' Wall Sign 0l( ~ .@ ~--~ @ ~-~ SHOPS SHOPS .@ @ ' ' ' ' ' ' ' 11 ! '·1..-·-----------··-··-··-··-··--~ Project Data Total GLA = TOTAL PARKING SPACES: SPACE/1000 SF OF GLA: Modified: November 14, 2017 268,696 1519 5.27 •-·-.., __ Site Plan 0 65 130 ·-----------·-· ------·-. --------------------------. ·, ' -. ~k-__ -__ -__ ~-~~~-~-~~~~~~~~~~@.~~~-·:::::::~~:~::::::~~::::::::~u @Li LANO~~E @~\---- 1cullbn emn @fl @ft:il 0f) i i o1 ~ e ;?:S (T8YP) % SHOPS ' :n@ iu@ 'e:!J_u"_ 0 -(\~//---\\~,,.---........-: -i) ~© ------ _,,,,,-~-<~'J _ (,o -d@ ~--~' ~ _/v@~ '• ~--x-, ,-~. -, .-~ , _/ .. ,, . -, , __ / _,/ @ , / '14' \!_::,, (,/ - ----@ '(/ ,,--- / 14 (7'_: ---~ / @ --/ ~ ----@ -- v @ @ " @ ------:::>· ----- 1 • ! --,--::------ ' ' ---Q[t\....,~9 --r.;;.. ----'})':!,~ ~10 OE. \)z_t>l ~ -00 2--:}-- 0 --:::>·: :-:-----© @ -· .--~@ o@ _.,::-- PERMIT NO. PS 2P l CzS -06 11.... DATE , .. ,;: .. -.. ~----.. --.. ------_ ___. PLANNING I '~ I~ u/,r h CD Q BUILDING Carlsbad Premium Outlets 5620 Paseo del Norte Carlsbad, CA 92008 <X> SIMON~ CORP# 7847 PREMIUM OUTLETS I w WALTON FRONT ELEVATION I I I Scale : 3/16" = 1'-0" PROPOSED FRONT ELEVATION • DAY Scale: Not to Scale 10101 Reunion Place Suite 500 San Antonio, TX 78216 P 210. 886. 0644 waltonsignage.com © io11 WAlTON All RIGHlS RESERVED Client OLD NAVY 4376 Address: 5600 PASEO DEL NORTE City/State: CARLSBAD. CA 92008 Sales: HOUSE Designer:_QQ_ Date: 01.15.18 PM J3!:L II II ' II I II II CL r--------16'-8" _____ __j I I ·'OLD NAVV KIDS@BABY .._,.■!2 ('I") ---------L ' II II T~ ~ II I ~ '\ '\ ' II ' If '\~~, ' '\ ~ '\ II II '\ / ' ' "Verify sign install height/location with Center Manager onsite. ~ ~ ' PROPOSED FRONT ELEVATION -DUSK Scale: Not to Scale Approved As Noted -Upon receipt of permit from city/county fabrication may be undertaken. Signs must conform lo all Landlord comments on these drawings. • Installation of sign lo be coordinated with Center Management not to disrupt business. Must provide Center Management with copy of permtt & insurance prior to installation & verify proper sign placement prior to install. • Center Management must sign off on sign installation when complete. <X> SIMON ,.JltEMIUM OUTLaT& By WaltonJ at 5:30:16 PM, 2fl/2018 .----SURVEY NOTE: ~ FIELD SURVEY REQUIRED PRIOR TO MANUFACTURE R . . ~------------~ Th' . . . . II . Approvals: This is a_n original drawing created by Walton. II ev1s1on: . Signs will be manufactured with 120 or 277 Volts A/C. Is sign Is intended to be Insta ed In . . is submitted for your personal use, however, 1t R1) 1/23/18 Change layout of blade sign· JD All Primary electrical service to the sign.and final accordance with the requirements of Sales. Date. shall at all times remain the_property of Walton. R2) 1/26/18 Resize blade sign • RH connection thereof. is the responsibility of the buyer. Article 600 of the National Electrical • . II may be used in connection with the proJect R3) 2/1/18 Specify edge lit construction for bolh ROPT cabinets_ RH All work Is to be done In accordance with the purchase Code and/or other applicable local P. M.. Date. being planned for you by Walton, bul nol R4) 2/5/18 Insert LL revisions and change sign layout. JD agreement attached he_reto. In case of vanance codes. This includes proper . . . otherwise. You are not authorized_ to show ____________________ between the specifications of the purchase agreement grounding and bonding of the sign. Design . Date. lhese drawings to anyone outside your ____________________ and this drawing, the drawing shall prevail. organization, nor is it to be reproduced, used, I P'/\GE SIZE· 11" 17" I Client· Date· copied or exhibited in any fashion. H:\Old Navyl_aLOCATIONSI_US SITES\CA\CA Carlsbad 4376\EXTERIOR 161493\0ESIGNS J-'I , X ' · 161493 Sheet: 3 of 7 - b "<t w WALTON ~--------------------------------16'-8"--------------------------------~ f------------------115 ½"-------------------i 1------------81 ½"---------~ r 29½"~ ~121/,"J 34' KIDS9BABYJ ~ r-- l n CUSTOM FABRICATED "OLD NAVY" HALO-LIT BLUE CHANNEL LETTERS with HALO-LIT BLUE R.O.P.T. CABINET AND "&" AMPERSAND CIRCLE Iii Scale: 3/4" = 1'-0" .llf:pll!,cd J>d Ntr-.cc --\:C:n 'I:~~ af '-Cnnl: ttcm :2:,,c?..1111 l.Lc' c.:J>r m;i,-be .nOC1a<en Sans ml.HI :on•:r-n IC ~I Wt!OkfG a:,,-,enlr. en t."f:'.;:, ar.,•rg~ SIGN AREA 55.56 SQ.FT 10101 Reunion Place Suite 500 San Antonio, TX 78216 P 210. 886. 0644 waltonsignage.com @ 2017 WALTON All RIGHTS RESERVED QUANTITY ONE1TI Client OLD NAVY 4376 Address 5600 PASEO DEL NORTE City/State CARLSBAD. CA 92008 Sales HOUSE Designer _QQ__ Date 01 .15.18 PM _filL ln:.mlol.:n :it ~qn ,o be oa~ncn:d ad, Ccl'I-.:< f.Qn:,;cmo·t ncr. ID '1 r.~u:t tu1l,c~1. t,1.,.1 pn,,i.J,, C•11i.. "'"""I,#",.. I .u, "+)'LIP• 111 l 111:au,~11_.. pr1:r 10 lnllalll'lo~ & ,-cnry pro:ioi< ,1;1r p\1t1emert s:r or t:, lrr.101. Cerr!t< 'hn•~rne-t rnu~ tiT elf on• 9n ntl11l•110n • ..,.,.n o:ni:u,1 <X> SIMON ••cw•· •M o tT\.rT• By WaltonJ at 5:30:09 PM, 217/2018 . . R . . ~------------~ Th' . . . ded be . lied . Approvals This is an original drawing created by Walton. It ev1s1on. Signs will be manufactured with 120 or 2n VoltsA/C. Is sign Is mten to msta m is submitted for your per.ional use, however, It R1) 1/23118 Change layootof blade sign -JD All Primary electrical service 10 the sign.and final accordance with the requirements of Sales: Date: shall at an times ramain the_propertyofWalton. R2) 1/26118 Resize blade sign. RH connecti?n thereof, is the responsibili1X of the buyer. Article 600 of the National Electrical , • It may be used m connection wi1h the project R3) 2/1/18 Specify edge Ill conslrudion for both ROPT cabinets. RH All work Is to be done m accordance wIlh the purchase Code and/or other applicable local P. M.. Date. being planned for you by Walton, but nol R4) 2/5/18 Insert LL revisions and change sign layout_ JD agreement attach~d he_reto. In case of variance eodes. This includes proper , otherw,se. You are not authon2ed_ to show ___________________ between the ~pec1ficat1on~ oflhe purchase agreement grounding and bonding of the sign. Design: Date: these drawmgs lo anyone outside your ___________________ and this drawing, the drawing shall prevail. o,ganization, nor is it to be reproduced, used, I P'"GE SIZE· 11" 17" I Client· Date· copiedorexhibitedinanyfashion. H:\Old Navy\__aLOCATIONS\..US SITESICAICACarlsbad 4376\EXTERIOR 161493\DESIGNS I"\ , X · ' · 161493 Sheet: 4 of 7 w WALTON 111 1/2" ALUM. SPACERS P.T.M. BUILDING ------~ 1/4" BOLTS AND TOGGLES TO BUILDING PAIGE WALLBUSTER ------~ ELECTRICAL BOX AT INSIDE FACE __ _, .--,_-:_-_-_-_I ,,, I _, 1" 3" #6 COUNTERSUNK SCREW .063 ALUM. RETURN PAINTED SATIN WHITE WHITE GE TETRA MINI MAX L.E.D. 3/8" CLEAR POLYCARBONATE with 70% WHITE DIFFUSER .125 ALUM. LETTER FACE P.T.M. 2955c BLUE J)J:pni.cd /le. Ntr.ce -~en rc:.o-=t of ~fTT1t. !\"cm :l:,,·c~nt, t~ c.:llr m.a,-be .ndll'1i><en :.cin~ mLHI ~cm•~ IC 311..!ndlefO Q;"ll""lef11~ en i:,e,.,., am•T'l~ ln~I ol.:n :ii ~Qn ,o be ai:1c-:2 nll\:d '""' Ccnv li.ln~cmo-l nir: lo d ::..·u:t tusl'le~s. 1.,,.,.1111u,l.lo. c .. nw 1-1111110,1111-I •II• "-H' LI P• nl I: hr.u,ao...i pr1:Y 10 lnllillll'>O!I & ,11:nry pro:.:r ~Isl!' p,z::rmert ~ror t:, UY.IOI. C"""' '.'an•~•ne-c ,nusl ,ir cll"e,, e9n ntlAl•lo:n·..,.•n 12:m:1111 ¢¢ SIMON •~Ml,, ... C, tT\."· DISCONNECT , -, ' -1, I ... ----.I 1,-J : ~=1.--.__":_-:.--:_-:_/1~ I By WaltonJ at 5:30:06 PM, 217/2018 10101 Reunion Place Suite 500 San Antonio, TX 78216 P 210. 886. 0644 waltonsignage.com (0 2017 WALTON ALL RIGHTS RESERVED I POWER SUPPLIES C·~,l~--, J h 1/4" WEEP HOLES THRU ACRYLIC AT BASE NOIES:. 1. ALL SEAMS PLACED AT TOP FOR MINIMUM VISIBILITY 2. INSTALLATION TO CONFORM WITH SECTION 600 OF NEC. 3. LETTERS FABRICATED TO UL STANDARDS. 4. LETTERS TO BE CONSTRUCTED TO PREVENT LIGHT LEAKS. 5. WEEP HOLES ARE FOR EXTERIOR LOCATIONS ONLY MOUNTING ~ INSTALLER IS REQUIRED TO VERIFY ACTUAL FIELD CONDITIONS & PROVIDE NECESSARY MOUNTING HARDWARE & METHOD OF ATTACHMENT TO ENSURE SAFE INSTALLATION. INSTALLATION TO MEET N.E.C., UL & LOCAL CODES OLD NAVY KIDS BABY El EGJBICAL tID1E: IT IS THE CUSTOMERS RESPONSIBILITY TO PROVIDE 120 VOLT PRIMARY ELECTRICAL SERVICE WITH DEDICATED CIRCUIT(S). INCLUDING GROUND WIRING DIRECTLY FROM PANEL BOX WITHIN SIX (6) FEET OF SIGNAGE. INSTALLATION TO MEET N.E.C., UL & LOCAL CODES -SECTION -HALQ-LIT CHANNEL LETTERS N.T.S. SECTION DETAIL IS TO BE VERIFY Client OLD NAVY 4376 Address 5600 PASEO DEL NORTE City/State CARLSBAD, CA 92008 Sales HOUSE Desrgner• _QQ_ Date 01.15.18 PM ....fil!_ . R . . ~------------~ Th' . . . I ded I b . II d. Approvals: This is an original drawing created by Walton. It ev1s1on Signs will be manufactured with 120 or 277 Volts A/C. Is Sign Is rn en o e rnsta e rn is submitted for your personal use, however, It R1) 1/23118 Change layoot of blade sign -JD All Primary electrical service to the sign.and final accordance with the requirements of Sales: Date: shall at all times remain the property of Walton. R2) 1/26118 Resize blade sgn • RH connection thereof, is the responsibility of the buyer. Article 600 of the National Electrical It ~ay be used in connection with the project R3) 211/18 Specify edge llt construction for both ROPT cabinets. RH All work is to be done in accordance with the purchase Code and/or other applicable local P. M.: Date: berng planned for you by Walton, but not R4) 215/18 Insert LL revisions and change sign layout -JO agreement attached he_reto. In case of vanance codes. This includes proper • othe1W1se. You are not aulhonzed to show belween the specIficat1ons of the purchase agreement grounding and bonding of the sign Design: Date: these drawings to anyone outside your ====================================== and this drawing, the drawing shall prevail. · Of'QBnization, nor is 1t to be reproduced, used, I P'"GE SIZE· 11 • 17" I Client-Date· copied or exhibited in any fashion. H:\Old Navy\_aLOCATIONSI_US SITES\CA\CA Carlsbad 4376\EXTERIOR 161493\0ESIGNS /"\ • X · · ·· 151493 Sheet: 5 of 7 w WALTON 1112• ALUM. SPACERS P.T.M. BUILDING------~ 1/4" BOLTS AND TOGGLES TO BUILDING PAIGE WALLBUSTER------~ 1" 3" ~----#6 COUNTERSUNK SCREW ~----RETURN P.T.M. 2955c BLUE .125 ALUM. PAN BROKE FACE/RETURN P.T.M. PMS 2955c BLUE (SATIN FINISH) 1------.118 WHITE POLYCARBONATE BACKER ---------<+--+-----WHITE GE TETRA MINI MAX L.E.D. .ll~pni.cd ~ N~ --~" nmi~t 111 :;cnnt. ttcm :t:,,cQ.nt1 t~ t,Ul:r fflllf be .11dC"1-"en Gcin~ ffllHI :.on':r,i IC .,, l.mdlef'O a:~•~ en t.-d111•r11~ ln::mloli::n :rt :a.in,:, be OD::l-:1 ncn:d •lh Ccn:cr IGn~cmo·t nir. lo d r.·u:t tusJ,:r.s. I.la.I pn,,IJ.. C•uM """"'2""-1 •llo "+>' c.l P• 111 l 11 .. u·a1> .. prl:r 10 lnU.al~on & •'Cl1fy prorr ,1i1r 1h1ccmcrt s:ror 1:, lr~IDI. Cernor ''"""~rnt-tmu\l tiT effort •on n~ehilc:n ·..r"n <>:rn:>"1 <X> SIMON •cw, ,jM o,,Tl,CT• ELECTRICAL BOX AT INSIDE FACE ---.-. .-:.:::, 11,1 I ,.. ""I i-------3/4" CLEAR ACRYLIC with 1st SURFACE APPLIED OPAQUE WHITE VINYL FOR EDGE LIT EFFECT By WaltonJ at 5:30:03 PM, 217/2018 10101 Reunion Place Suite 500 San Antonio, TX 78216 P 210. 886. 0644 waltonsignage.com (l:) 2017 WALTON ALL RIGHTS RESERVED \ I 1..,I : :)~~\~,-:,, with 1 /8" trimmed border DISCONNECT I POWER SUPPLIES (: '"~l --, J ,:::::;i-------+1--+------3/8" CLEAR POLYCARBONATE with 70% WHITE DIFFUSER STUDS WHITE GE TETRA MINI MAX L.E.D. ALONG EDGE 1/4" WEEP HOLES THRU ACRYLIC AT BASE .MCIES: 1. ALL SEAMS PLACED AT TOP FOR MINIMUM VISIBILITY 2. INSTALLATION TO CONFORM WITH SECTION 600 OF NEC. 3. LETTERS FABRICATED TO UL STANDARDS. 4. LETTERS TO BE CONSTRUCTED TO PREVENT LIGHT LEAKS. 5. WEEP HOLES ARE FOR EXTERIOR LOCATIONS ONLY MOUNTING Nore INSTALLER IS REQUIRED TO VERIFY ACTUAL FIELD CONDITIONS & PROVIDE NECESSARY MOUNTING HARDWARE & METHOD OF ATTACHMENT TO ENSURE SAFE INSTALLATION. INSTALLATION TO MEET N.E.C., UL & LOCAL CODES OUTLET • ELECTRICAL~ IT IS THE CUSTOMERS RESPONSIBILITY TO PROVIDE 120 VOLT PRIMARY ELECTRICAL SERVICE WITH DEDICATED CIRCUIT(S). INCLUDING GROUND WIRING DIRECTLY FROM PANEL BOX WITHIN SIX (6) FEET OF SIGNAGE. INSTALLATION TO MEET N.E.C., UL & LOCAL CODES m SECTION -HALO-LIT ROUTED BLUE CABINET with PUSH JHROUGH "OUTLET" LETTERS AND "&" AMPERSAND N.T.S. Client OLD NAVY 4376 Address. 5600 PASEO DEL NORTE City/State CARLSBAD, CA 92008 Sales HOUSE Designer __QQ__ Date 01.15.18 PM ....fil!_ R . . -------------~ Th' . . . . 1 . Approvals This is an original drawing created byWaltoo.I1 evIsIon Signs will be manufaciured with 120 or 277 Volts A/C. Is sgn IS mtended to be Instal ed m is submitted for your personal use. however,~ Rt) 1/23118 Change layout of blade sign -JD All Primary eleclrical service to the sign.and final acconJance with the requirements of Sales: Date: shall at all times remain the property of Walton. R2) 1/26/18 Resize blade sign -RH connection thereof, is the responsibility of the buyer. Article 600 of the National Electrical It~ be used in connection with the project R3) 2/1/18 Specify edge lit construction for both ROPT cabinets· RH All work is to be done in accordance with the purchase Code and/or other applicable local P.M.: Date: being planned for you by Walton, but not R4) 2/5118 Insert LL revisions and change sign layout-JD agreement attached hereto. In case of vanance codes. This includes proper . otherwise. You are not authorized to show __________________ between the ~pecificatioos of the purchase agreement grounding and bonding of the sign. Design: Date: these drawings to anyone outside your __________________ and this drawing, the drawing shall prevail. organization, ra is it to tie reproduced, used, I P'AGE SIZE· 11" 17" I Client· Date· copiedorexhibitedinanyfashion. H:\Old NavylaLOCATIONS\..US SITES\CA\CACarisbad 4376\EXTERIOR 161493\DESIGNS • X ' ' :::1)161493 Sheet: 6 of 7 .. w WALTON 10101 Reunion Place Suite 500 San Antonio, TX 78216 P 210. 886. 0644 waltonsignage.com (i:) 2017 WALTON AU RIGHTS RESERVED ~ CD Client OLD NAVY 4376 OLD NAVY KIDS$BAB'li OUTLET f---------31 ½"-------~ t-----------36"---------i r:1 NON ILLUMINATED DOUBLE-FACE BLADE SIGN 1:1 Scale: 1 ½" = 1'-0" SCOPE OF WORK: • MANUFACTURE AND INSTALL ONE (1) NEW BLADE SIGN SIGN AREA _Q_UANTITY 3SQ.FT ONE ill ,,.---USE LOCKING STYLE CARABINER HARDWARE TO HANG SIGN 3/16" WHITE POLYCARBONATE FACE with ½" CLEAR ACRYLIC PAINTED TO MATCH PMS 2955c BLUE (SATIN) WITH PAINTED GRAPHICS TO MATCH PMS 2955c BLUE (SATIN) letters must be cut out and dimensional (not vinyl or painted) . .._.. . s::: ... -..... N N O ..- _:JJ I 2• I Verify aud u s<: preferred hangiug method at center. Pf!pni.cd A'. Na-..."1! -.,\:en n:~~I of ~nnt. trcm :,;,,"to .. m, t.c, c;.m:r ma,· be .11dD1:i<en s11n~ ffllllll :on•·;r, IC ;,t ~llleni a:,.,....,,enl~ en u,e,~ an,•rgr, ln:mlallcn :11 llQn 10 be 01lll':lnll\:d alll Cemcr r.t,m;ccmD·t nir. lo d ~ -u:it tu11-.:~1;, t,1..,1111u,Uw C•1o\o; w .. ,,..,_.,,,.,. I .u, '-4-)' c.f P• n l i l11,u11u,...i pr\:." lo ln1t;lir,011 & ,>cnly pro:i..'1' llt:f, p\la:mcrt i:ror 1:, 111:101. Cen,!!t 'hn&~rne!(mu~ ei;r cll'cn •rJn nt11t•1cn•..,•n n:m:-"1 <X> SIMON •--cw• ,M (hJT\,r"T• By WaltonJ at 5:29:52 PM, 2/712018 .080 ALUM. RETURN P.T.M. PMS 2955c BLUE (SATIN FINISH) R . ~-------------Th' . . . t ded be. l1ed . Approvals This isMoriginal drawing created byWalta1. !t ev1sIon Signs will be manufactured with 120 or 277 Volts A/C. IS Sign IS In ?'1 to msta on • • is submitted for your personal use, however,~ Rl) 1/23118 Change layout of blade sign• JD All Primary electrical service to the sign.and final accordance with the requirements of Sales. Date. Address 5600 PASEO DEL NORTE City/State CARLSBAD. CA 92008 shall at all times remain the_ property of Walton. R2) 1/26118 Resize blade sign • RH connecti?n thereof, is the responsibilil'>'. of the buyer. Article 600 of the National Electrical • • It may be used on connection with the project R3) 2/1/18 Specify edge lit construction for both ROPT cabinets-RH All work 1s to be done on accordance with the purchase Code and/or other applicable local P.M.. Date. being planned for you by Walton, but not R4) 2/5118 Insert LL revisions and change sign layout-JD agreement attached hereto. In case of vanance codes. This includes proper . otherwise. You are not authorized. to show '-==-~-----~~~-""'-'--"=----between the _specification~ of the purchm;e agreement grounding and bonding of the sign. Design: Date: Sales HOUSE Designer _QQ_ Date 01.15.18 PM _filL these drawings to anyone outside your ------------------and this drawing, the drawong shall prevail. organ1zalion,noris~tobereproduced,use<1. '---------------' 1 P'AGE SIZE· 11" 17" I Client· Date· copiedorexhibitedinanyfashion. H:\Old Na"Y'l.aLOCATIONS\..US SITES\CAICACarlsbad 4376\EXTERIOR 161493\DESIGNS , X · · C,D 161493 Sheet: 7 of 7