Loading...
HomeMy WebLinkAboutPS 2018-0064; ARCO AM-PM #42347; Sign Permits/Programs (PS).. ' "' Ccityof Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov Dli-" t .. c)l ct-o I l \ PLANNING APPLICATION# PS 1--a>\t---()O~'( REC'D BY \,~~, S~\'").>t-L SIGN FEE V ~ '$ '?.!' DATE <, I S~I ¥ SIGN PROGRAM F~ ----------RECEIPT NO. ___________ _ NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: __ 4-/Yl"--'-=cJ_~...,,oo<.......,;.~~_,Y_?.-'"""3"'-4~J-+-____________ _ Address of Project: --~<-+/ ..... O.___T,""""~ .............. =~=~"'-=--t\J-e-"'-' _________ _ Assessor Parcel Number: _______________________ _ Related Planning Case Number(S): ____________________ _ TYPE OF DEVELOPMENT: Residential Commercial Office/Industrial (d) Hotel/Motel t""'ieb Service Station '-{ff" Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA U) Produce Stand (k) Nursery (I) P-U/OS Zone Yes □ No □ Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes, please complete information on page 3) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes □ SIGN ORDINANCE: Yes □ No □ COASTAL ZONE: Yes □No □ P-11 Page 1 of 4 No □ No □ Rev. 02/28/18 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I I PfL • Sight Distance Requirement I I Show building Is : I . . I : I : ; I , _____ i Show setbacks from all curbs ---. . ' ' ! I I I Show all property lines I ! PfL : . I . : . I . . curb line . . : . . . ----------~--- • • Sight Visibility I Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: __ 3=---0""""'-... 0<C...>-Q....,c_ __ sq. ft. Total Building Street Frontage: 80' linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): \ \ ~ sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): \ o 7 sq. ft. Remaining Sign Allowance After Proposed Sign: tJ sq. ft. VILLAGE REVIEW AREA Total Signable Area: '2-':\ sq. ft. Total Signable Area Length: ---Z'!-:~!,._, ,-~-t-(~"~--sq. ft. Total Signable Area Height: ?, sq. ft. Total Projection from Wall Face: '' inches P-11 Page 3 of 4 Rev. 02128/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument L--z-.s r ... ' Wall "'2..-3~ 41 . Suspended/Projecting Directional Canopy -z, I~ -<:" , r,,.,/u ~ :2--L.\ "Zo''; ? l/ II -I I Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes □ No □ Date -------- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** Wall \ ·2-4 1'-3" Suspended/Projecting Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 02/28/18 PROPERTY OWNER APPLICANT NAME PRINT OR TYPE NAME PRINT OR TYPE \ Gt>t::>tt" ~\t:>~~ -\)Or\c.:) 'f sv,.) MAILING ADDRESS MAILING ADDRESS l/582- CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KN WLEDGE. PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF M NOWLEDGE. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. P-11 Page 4 of 4 Rev. 02/28/18 . l •,, • \ \ \ \ .\ ,. <I I ~ ~I .., ~ 7" \) 0 0 ► I co °"' C UJ ~ 6 a:: 0. Cl) Q. Q. c( ci z t: ~ a:: LI.I Q. z C) ii:; NORTH ~ ~ ---~ ~ C) C> z z z 0 z ~ ~ :::, Q. co ~ -~,11 Donco & Sons, Inc. Signs • Lighting • Electrical 4582 E. Eisenhower Cir., Anaheim, CA 92807 Ph: {714) 779-0099 Fx: (714) 779-0198 CA St Lie. #435616 C10-C45-C61 CUSTOMER: TESORO CORPORATION 19100 RIDGEWOOD PARKWAY SAN ANTONIO, TX 78259 (210) 626-7390 SITE PLAN PROJECT ADDRESS: ARCO STATION #42347 810 TAMARACK AVE. CARLSBAD, CA 92008 DATE: 5-14-18 REVISION I DATE 1 6-05-1 8 2 3 4 SCALE:NTS SHEET NUMBER _1_ OF _L DRAWN:A.S. ALL RIGHTS RESERVED All designs & prints are the exclusive property of "Donco & Sons, Inc." And may not be copied, distributed, modified, reused, reposited, reproduced or otherwise used without express written permission. Any un-authorized use or duplication will result in a 20% charge per occurrence per the value of the display. 31 " SIGN CABINET 10" ----------583/4"---------- 14--------------645/8" ------------- 11.892$.Q_.FT. 88 ¼11 -------------------i BACKING WIDTH 1" BACKER •s•--, 1" BACKER "A" -1 1 76 7/8" L -----------sis1GN CABINET FRONT ELEVATION 24 SQ.FT. 39" BACKING HEIGHT 3" DEEP PAINTED WHllt SED 1/rEMBOS' AMPM DECORATIO ~ I I ,.. - WEATHERPROOF Tl DISCONNECT S1 ~ . nee COMPONENTS AND SHALL MEET ® Underwriters (£fy ELECTRICAL TO USE U.L. LISTED Laboratories Inc. f ALL N.E.C. STANDARDS ALL ELECTRICAL SIGNS ARE TO COMPLY WITH U.L. 48 AND ARTICLE 600 OF THE N.E.C. STANDARDS, INCLUDING THE PROPER GROUNDING AND BONDING OF ALL SIGNS. FORMI BACKGI 2" s· ~ '-.._ "tQ, PIN MOUNTED ·- ~ SIDE VIEW APPROVAL SIGNATURE By signing, you are validating the dimensions and graphic provided to SignResource and/or you ore handling your own inllallation. .,~~f;!':f;~s?,~1;~~ 6135 District Blvd • Maywood. CA 90270 800.423.4263 • Fax 323.560.7143 Website. www.signresource.com REVISION HISTORY: m I DAit I IIOUESTID n C 10/06/17 MJ. --REVISED TO 39" HEIGHT iiiimoif J.V. m I OATE I ttOUE.Sn.Dn I tl'DlTtDl1 D 10/12/17 M.J. J.V. --REVISED DIMENSIONS m I DAit I IIOUESTIDn I IWOOl!J n E 10/26/17 M.J. J.V. --REVISED AS PER FILEi_PROVIOEO PARTS LIST: ITEM DECORATION DIGITAL PRINT GRADIANT BAO:GROUND LOGO [WHITE TRANSLUCENT/ OPAOUE -PM 2597 C BACXER -PM 166 C BACKER -■ PM 021( -PM 032( -■ PM PURPLE -PM 072( MATERIAL UST [ALUMINUM PLASTIC LED IUUMINATION 71l FIRST & SECOND SURFACE DECORATION TllS SIU IS IIITEIIDEII TO IE INSTAWD ■ ACCOIIIIAICE WITH nE IIEQUIIIDIEIITS Of MTICI.EIOIIOflllE IIA110IIAI.BS:TIIICCOIIE Mll'OII OTIIEII APPUCA1U LOCAL CODl:S. TllS ■cl.lllU --ANO -OfnE- GENERAL NOTES 1.10\UAIKE ( UNlfSS NOTED) •GMKS +/·1/8" • FACISUE + 1/16"-Y, •CABIN£! +/-1/8" • VINYLOVERlAP + 1/8" +/1/16" • All COPY lfVH UNlfSS NOTED OTHERWISE 2. VIEWING DISTANCE 2S' TO SO' UNlfSS NOTED OlllfRWISE 3. PMS COlOR CAIIOUT INDICATES USE Of SPRAYIAT MIX SYSTEM 4. NO DEVIATION Oi MATUIAL SUBSTITUTlON WITHOUT ECN. S. ALI ELECTRICAL SIGNS TD (()l,IPLY WITH UL 48 ~ AMPM SIGN W/ EMBOSSED LOGO DUAL LIT CABINET HALO WITH 2 COLOR BACKING JOLJAGE, CIIQJl1, CIJtltllft DIIIGN LOAD, 120 VAC ONE 5 W.P 30PSI DIAWNn, OIIOI.Dn, MMAGAT AMPM/ ARCO UlCA!lllll, VARIOUS DAit, VARIOUS 9/01/16 DIAWINGIPAIT I REY. SHEET # AMPM0308SIGN E l OF l llril..__ ..... _.._ • ....., ................ ...,., • ......... _ .................... ~,.---~....-.~-.,,._ COLOR LEGEND [EI] BENJAMIN MOORE. oc-69, -....nr OPUL£NCE" (EJ ORANGE, TO W.TCII PMS 166 MATERIAL LEGEND EXISTING BUILDIN~ (E) AM-PM SIGN -35 SQ.FT. PROPOSED NEW BUILDING SIGN I .ICIH I ALUMINUM COMPOSITE MATERIAi. ORANGE i ACll-2 ! ALUMINUM COMPOSITE MATERIAi. SIL~ i ACll-3 ! ALUMJNUM COMPOSITE MATERIAi. BRAZILIAN WALNUT SIMUlATED WOOO GIWN 1 • 80'-Q" I P-1 I I ,CM-I P-1 -,- t C> ' lO _l_ P-1 ,~· Donco & Sons, Inc. Signs • Lighting • Electrical 4582 E. Eisenhower Cir., Anaheim, CA 92807 Ph: (714) 779-0099 Fx: (714) 779-0198 CA St. Uc. #435616 C10-C45-C61 CUSTOMER: ~ TESORO CORPORATION 19100 RIDGEWOOD PARKWAY SAN ANTONIO, TX 78259 (210) 626-7390 SIGN PLAN PROJECT ADDRESS: ARCO STATION #42347 810 TAMARACK AVENUE CARLSBARD, CA 92008 DATE: 5-15-18 REVISION I DATE 2 3 4 SCALE:NTS SHEET NUMBER _g_ OF _1_ DRAWN:A.S. ALL RIGHTS RESERVED All designs & prints are the exclusive property of "Donco & Sons, Inc." And may not be copied, distributed, modified, reused, reposited, reproduced or otherwise used without express written permission. Any un-authorized use or duplication will result in a 20% charge per occurrence per the value of the display. .. SIGN PROPOSAL MONUMENT PRICE SIGNS 2 25 50 ADDRESSING TRAFFIC 24" CANOPY BUTTON SIGNS 3 4 12 ON CANOPY FASCIA CANOPY CHANNEL LETTERS 2 6 12 ON CANOPY FASCIA CAR WASH LETTERS 1 9 9 ABOVE CAR WASH EXIT (N) BUILDING WALL SIGN 1 24 24 NEW SIGN ABOVE STORE ENTRANCE PROPOSED TOTAL SIGN AREA = 107 SQ.FT. * THE FOLLOWING APPLIES TO ALL ELECTRICAL SIGNS: U.L. LABELS, EXTERNAL DISCONNECT SWITCHES, CONNECT TO EXISTING ELECTRICAL CIRCUIT DONGO & SONS, INC. 4582 E. EISENHOWER CIR ANAHEIM, CA 92807 714-254-0099 ST. LIC. 435616 C10 C45 C61 AM-PM MOJO IMAGE DATE: 6/1/2018 TESORO CORPORATION 19100 RIDGEWOOD PARKWAY SAN ANTONIO, TX 78259 JOHN BARBER 714-254-0099 ARCO STATION #42347 810 TAMARAKAVENUE CARLSBAD,CA