Loading...
HomeMy WebLinkAboutPS 2018-0122; JEUNE ET JOLIE; Sign Permits/Programs (PS)(city of Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov p:€: v' z..o \ 8 -,s, , ~ 4- PLANNING APPLICATION# 7'<; '2.--0 \ $ -o I 1,;t..- REC'D BY <°~ v .,.___ 1..--.. C , V\ -{f DA TE lP / :Z,,$"' / ( S SIGN FEE t 1, ":J • oc:> SIGN PROGRAM FEE ________ _ RECEIPT NO. f t, l-,2'. t3(2 f O ~ O OU ocr~.> NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). 8. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: :TitJt>ef:-1-_)A~' Address of Project: Uff ~ S'1 Assessor Parcel Number: 'k(} ; _,,, ~ ~ ~ 0 Related Planning Case Number(S): ___________________ _ TYPE OF DEVELOPMENT: (_&_ Residential ~ Commercial (c) Office/Industrial (d) (e) (f) Hotel/Motel Service Station Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA 0) Produce Stand (k) Nursery (1) P-U/0S Zone Yes □ No □ Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes, please complete information on page 3) Yesilf" SOUTH CARLSBAD COASTAL REVIEW AREA Yes L] SIGN ORDINANCE: Yes O No O COASTAL ZONE: Yes □No 0 P-11 Page 1 of 4 No □ No □ Rev. 02/28/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall NIA Suspended/Projecting Al l'1 Directional I Canopy • Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ------- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Pole** Monument** Wall I 4,ifi 7'' Suspended/Projecting I ,4..:3;1 1.A'' Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Construction** For Sale** A/ ,, Banner IV I , --. Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 02/28/18 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed · for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I l I P/L : Sight Dist~ce Requirement . . I Show building/s . . . . I . . I : : I , ___ j Show setbacks from all curbs --- ' . . I . I ' . . I . I Show all property lines I . . P/L : . : I . I ,: curb line . ! . . . ----------~--- • • Sight Visibility I Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: ----,,=--=......------sq. ft. Total Building Street Frontage: Sf}0~ 1 ' linear ft. Total Signage Allowance: ~ ~ sq. ft. Existing Signage (sq. ft.): ~ sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): f ~ sq. ft. Remaining Sign Allowance After Proposed Sign: ,., ti sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 PROPERTY OWNER MAILING ADDRESS CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. APPLICANT TELEPHONE I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO T E BEST OF MY. KNOWLEDGE. 10l~/!B DATE 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: In right-of-way In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved rout~ Entry APPROVED: Planner: ~ ~ Date: IO ' 2. ', · / .:') P-11 Page 4 of 4 Rev. 02/28/18 FABRIC 619-840-7721 125 S. Highway 101 Suite 101 Solana Beach, CA 92075 September 21, 2018 Curtis Clave Fabric Investments Inc. 125 S. Highway 101 Suite 101 Solana Beach, CA 92075 To Whom It May Concern, This is written approval for John Resnick of Jeune Et Jolie's sign design, application and installation referencing drawing number 18488. There is a maximum square footage allotment of 29 square feet the sign(s) need to be within. Sincerely yours, Curtis Clave Principal 760-683-4631 JEUNE ET JOLIE 2659 State Street Carlsbad, CA 92008 PERMIT PACKAGE Cover Sheet 1 : Site Plan Sheet 2: Elevations Sheet 3-4: Sign Details Sheet 5: Structural Drawing SCOPE OF WORK Install (1) One Set FCOs 7"h x 7'-8'w (4.5 sq.ft.) Install (1) One Double Sided Blade Sign 2'h x 2'-1'w (4.27 sq.ft.). Value -$4500 ~ f~ J-u.--h ~ s,~~ , s A-ry,~J i"' ,h ~c~ ,~ \lo,\ \i.e. ~ CA. vv-U. S.\S"" a,\,1/'-< ~ v"UJ,,,I' 1Pv$ I ~c;s ~ tv-v_) f.,t /,"'1 1\--..t. ('Af"\c.-l~ L,,i-. ,f A. S<c1M--<-a..r".'.J r~" l..vs I lf'\.e'>~ .J2....V\..~ ,,,_,,,J.J. SI j ~ ,-_k-1-0 Sf I 5 Y-L '}:r"<!-~+-e,-( '"' "'"'-c... 'T"'-N ~ 1 1"'-L f r,, J~ C-'h J S \ ~ "' "-"' \ \ \ be.-v .L. ~ ·, ,r ~ J_ -\.,o ""'-,--.1e. , ._ f,-<M-.\-'b ')\---<_ b .... ' l -t \ ~ ~ l 0-A 'j s ~ t-c-h,...-.c.-.e-t:"" ,--'" V \ I\ A, 'a'-~ 6,u·-Y; 0 MA~ k ~ f'l« n ~ ..... ~ l Or ~~ .s fp. ~ vJ ' 'ii"~ -019 4-- SIGN PERMIT NO. PS u 1 ~,.. ~ i 1-1-- APPROVED BY DATE PLANNING ~~u-<---y to~fl6 BUILDING ' ! SITE PLAN JEUNE ET JOLIE 2659 State Street Carlsbad, CA 92008 PROPERTY OWNER: 2659 State Partners, LLC 375 Via Linda Del Sur Encinitas, CA 92024 LEGAL DESCRIPTION: Lot 8, Map #1722 A.P.N. 203-054-2600 SITE MAP Signs p~:_ SlgnA__,_-,_ -- This sign is intended to be instaled in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. The location of the disconnect switch after instaaation shal comply with Article 600.6(A) (1) of the National Electrical Code. Jeune Et Jolie FCOs & Blade JOB LOCATION /ADDRESS 2659 State Sl Carlsbad, CA 92008 PRESENTED BY Sieve Arelz Drawing Date: 10.01.18 OrawilD By: TINNnla Nlwllu 18488 SHEET: 1 of: 5 18'-3 3/4" ' fl fl fl l , 30'-5" Frontage Sign A (.!) I 30'-l" ELEVATION (EAST) SCALE: 1 /8" = 1' 11'-8 3/4" fl SignB + 15'-6" $ u.: u.: <i. 0 I ' 0 L() I ..... N -fl + 0'-0" l , This sign is intended to be instaled in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. The location of the disconnect switch after installation shal comply with Article 600.6(A) ( 1) of the National Electrical Code. Jeune Et Jolie FCOs & Blade JOB LOCATION/ADDRESS 2659 Stale St. Carlsbad, CA 92008 PRESENTED BV Steve Anlz E-Mal: ...... 111i ... LCOffl Drawing Date: 10.01.18 Drawing By: TINNna Nlwllll 18488 SHEET: 2 of: 5 ~[J EU N E ET SIGN SCALE: 1" = 1' FCOs: 1/2" ACRYLIC PAINTED IIATTHEWS SW23 fe BLACK}, SAT,IN FINISH. IIOUNTING: FlUSH MOUNT ON EXTERIOR WALl, WITH VHB AND SILICONE. PLACEIIENT: ON CENTER ABOVE DOOR, 10-1/2" FROM TOP OF 'BUILDING TO SASEUNE OF TEXT. LOCATION: SEE MAP. SQ.FT.: 4.5 • MATTHEWS SV923 (BLACK) JOLIE SignA It 18'-3 3/4" ~ -----ir E U NE E, irOLIE V' ' ¢ ¢ ¢ ¢ I I I I I ELEVATION (EAST) SCALE: 1/8" = 1' 1/r n FLAT -cuT our _ ____,. ACRYLIC -----t--VHB TAPE LETTER (TYP.) - _...__,.---+-_,,\;,ILICONE ADHESIVE WAL,__! ---•t (TYP.) FLAT CUT OUT ACRYLIC LETTER INSTALLATION DETAIL TI'-8 3/4" ~ ' ¢ ¢ + 0'-0" This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other appkable local codes. This includes proper grounding and bonding of the sign. The location of the disconnect switch after instalation shal comply with Article 600.6(A) (1) of the National Electrical Code. Jeune Et Jolie FCOs & Blade JOB LOCATION /ADDRESS 2659 State SL C111sblcl, CA 92008 PRESENTED BY Sten Arelz E-MII: ............. LCOffl Drawing DIii: 10.01.18 Drawing By: TINNRII Nlwlllll 18488 SHEET: 3 of: 5 / ,/ , 2'-1518" ,. / -~------------ 2'-0" SIGN SCAL:E: 1" = 1' SIDEVIEW SCALE: 1• = 1' BLADE SIGN: FABRICATED METAL, s• RETURN, ROUTED FACES, 1/8" ACRYLIC BACKER (0 WHITE), PAINTED MATTHEWS SW23 ,-BLACK), SATIN FINISH, MOUNTING BRACKET: FABRICATED METAL, 2" SQ. TUBE WELDED TO s· X s· X 3/8" ALUM. PLATE. IIATTHEWS SW23 fe BLACK), SATIN FINISH. MOUNTING: FLUSH MOUNT ON NORTH FACE EXTERIOR WALL, WITH (TBD AFTER SURVEY). PLACEMENT: 1' FROM LEFT EDGE OF BUILDING, 12' A.F.F. 1s• DOWN FROM TOP OF BUILDING, TO TOP OF SIGN. LOCATION: SEE MAP. P:.11.T CO~OI? SCl1EDllLE • MATTHEWS SV923 (BLACK) SignB 18'-3 3/4" ' ~ ELEVATION (NORTH) SCALE: 1/8• = 1' (,;J;... --J'E UN[ E, iJ"O LI£ I I I ELEVATION (EAST) SCALE: 1/8" = 1' ' 11'-113/4" +15'-6" $ +o·-o· This sign is intended to be instaled in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. The location of the disconnect switch after installation shal comply with Article 600.6(A) (1) of the National Electrical Code. Jeune Et Jolie FCOs & Blade JOB LOCATION /ADDRESS 2659 State St. Carlsbad, CA 92008 PRESENTED BY Steve Aretz This design is 1111 uclullwt~ of Stanford Sign 11111 & may not bl rap,oduclcl, •In or In part. wllbout Ill wrlllln cOIIIIIII of Stanford Slln and Awninl- AII ,,,_,,.,.,,,.,,. ,_...,.. .... ,,,,,,,,,_., ..... NOTE: Al ........ 1I111I wNllw ................. Drawing Data: 10.01 .18 Drawing By: 1'11111111 NlwmM 18488 SHEET: 4 of: 5 VI JNGMAN I [NGIN[~RING 2172 FELSPAR ST. UNIT. 8, SAN DIEGO, CA 92109 MICHAEL@YUNGMANENGINEERING.COM PHONE: 1-a58-705-0557 PROJECT: JEUNE ET JOLIE, 2659 STATE ST., CARSBAO, CA PROJECT#: 1592 DATE: 9-18-2018 ENGINEER: MTV CLIENT: STANFORD SIGN & AWNING 2·-t a· RT 2"x2"x¼" ALUM. t 6" WOOD STUDDED It It 'I 'I WAWBLOCKING BY OTHERS @ @ C) ELEVATION ¼ (9) (9) GENERAL, NQJES 1. DESIGN CODE: CBC 2018/IBC 2015 2. DESIGN LOADS: ASCE 7-10 ¾"XrxS" ALUM. PLATE W/ (4) ¾•DIA.LAG SCREWS 3" MIN. THREAD PEN. INTO WOOD STUD OR BLOCKING 3. WINO VELOCITY 110 IFH EXPOSURE D 4. ALUMINUM EXTRUSION 1081-18 ED PLATE DETAIL 5. INSTALL LAG SCREWS PER NOS SPECFICATIONS e. WOOD SCREWS SHALL NOT BE LOADED FROM END GRAIN OF WOOD 7. SCOPE OF Wl0RK IS LNTED TO THE DESIGN OF SIGN 8UPPORTS, MOUNTING PLATES ANO ATTA<HENTS TO BUILDING. SCOPE OF WORK EXCLUDES PERFORMN3 CAPAarY CHECKS OF WALL B.BENTS, BllLOING STRUC1URE, OR OTHER EXISTING STRUC1URAl ELEMENTS, ALL OF WHCH ARE BY OTHERS 8. INSTAU.ER MUST VERIFY EXISTING CONDITIONS ARE ACCURATE WITH YUNGMAN ENGINEERING DRAWINGS BEFORE IN$TALLATION. CONTACT YUNGMAN ENGINEERING IF THESE CONDITIONS ARE NOT MET 11t fo ;c, This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. The location of the disconnect switch after installation shal comply with Article 600.6(A) (1) of the National Electrical Code. Jeune Et Jolie FCOs & Blade JOB lOCATION /ADDRESS 2659 Stale St. Caltsbad, CA 92008 PRESENTED BY Steve Antz E-Mail: ......... LCCIIII This design ii 1111 ~-£': of Stanford Sign lllf . ' may not be rapaclll, In or In part, wllllcM 1111 Wlillln COIIIIIII of Stanton! Sign -Awninl- M ,,,._, .,..,,,_, .. :,. ,..,,_ .... ,,.,,,.,,, . NOTE: 11...,..1,111 I .... ...... 1 .............. Drawing Date: 10.01.18 Drawing By: Tlllms Nlwllllll 18488 SHEET: 5 of: 5