Loading...
HomeMy WebLinkAboutPS 90-13; San Diego County Data-Tel, Inc.; Sign Permits/Programs (PS)City of Carl sbad 2075 Las Palmas Drive Carlsbad, CA 92009 (619) 438-1161 DATE t-50 SIGN FEE $25.00 SIGN PROGRAM FEE $l50?00 RECEIPT NO. SIGN PERMITS APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS. Average processing Time: 2 weeks ADDRESS OF PROJECT: s74- I<r EL "40 @€PL NAME AND PHONE NUMBER OF APPLICANT: -JCAT~L~S - 471 a PLANNING CASE NUMBER: SIGN TYPE: @ Commercial (b) Industri a1 (c) Residential (e) Real Estate (e) Freeway (f) Marquee (9) Community identity (h) Service Stn. Prices (I) Campaign SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA: Yes /No SPECIFIC PLAN NUMBER 6pf BLf-5 VILLAGE REDEVELOPMENT AREA Yes No **REQUIRES VR APPROVAL SIGN ORDINANCE: Yes No / COASTAL ZONE: Yes NO ~OASTAL PERMIT Yes No - / EXISTING SIGNS: Tvoe Number Si ze (a) Pole (b) Monument (c) Wall 14"X7 ' PERMITS ISSUED FOR EXISTING SIGNS: Yes No - Date BUILDING FRONTAGE: (Building street frontage) 11: ft. EXISTING SIGNS (SQ. FT.): REMAINING SIGN ALLOWANCE (AT PRESENT): PROPOSED SIGN: 9 sq. ft. REMAINING SIGN ALLOWANCE (AFTER THIS SIGN): L sq. ft. / sq. ft. - sq. ft. PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Specific Plan criteria, 1f applicable. B 4. Location: In right-of-way In visibil ity triangle at corner On roof CITY OF CARLSBAD 1200 ELM AVENUE CARLSBAD, CALIFORNIA 92008 438-5621 ACCOUNT NO. DESCRIPTION AMOUNT RECEIPT NO. g!?g 95 TOTAL 1 CARLSBAD GATEWAY CENTER 1 SIGN CRITERIA-BUILDING B "RETAIL" A. ) Introduction These criteria have been established for the purpose of assuring an outstanding center and for the mutual benefit of all tenants. The intent is to provide the guidelines necessary to achieve a visually coordinated, balanced and appealing signage and graphic enviornmefit for Carlsbad Gateway Retail Center. Conformance of these criteria shall be rigorously enforced and any non-conforming signs shall be removed by the tenant or hidher sign contractor at their expense, upon demand by the owner. Exceptions to these standards shall be reviewed by the owner. However, based upon our field experience, deviations will generally result in serious inequities between tenants. Accordingly, the owner will retain full rights of approval of any sign used in the center. B.) General Owner/Tenant Requirements 1. 2. 3. 4. 5. 6. 7. 8. Tenant shall submit or cause to be submitted, to the owner for approval before fabrication, at least four copies of detailed drawings indicating the location, size, layout, materials, lighting method, design, and color of the proposed signs, in- cluding all lettering and/or graphics. All permits for signs and their installation shall be obtained by the tenant or hidher representatives. The tenant shall pay for all signs, their installation (including final connection, transformers and all other labor and materials) and maintenance. The tenant shall provide primary electrical service termination at the center of the allowed signage area as per the accompanying design criteria. It is the responsibility to the tenant's company to verify all conduit and transformer locations and service prior to fabrication. Location of all signs shall be per the accompanying design criteria. One "sign space" shall be allowed for each tenant (except as other- wise approved in writing). The tenant shall verify hidher sign location and size with the owner prior to fabrication. The maximum allocated sign area for the aggregate of all permanent signs shall be noted herein. 2 9. The tenant shall be responsible for the fulfillment of all require- ments of these criterial. I C.) General Sign Specifications For Building B I. 2. 3. 4. 5. 6. 7. a. 9. Each tenant shall have one required identification sign. Signs shall be located as indicated on attached drawing. See exhibit A. Tenant signs shall consist of individual illuminated or non-illu- minated letters affixed directly to the building fascia. See exhibit B attached for details and specifications. Illuminated signs are to be comprised of individual reverse channel fabricated plexiglass letters with low voltage llhaloll illumination as per manufactured by RB Signs. See exhibit B attached for details and specifications. Non-illuminated signs are to be comprised of individual reverse channel fabricated plexiglass letters. All letters shall have painted finish to match Duranodic f313. Paint shall be lacryl manufactured by Spraylat #20-55 or equal. The llcopyll, letter style, and logos shall be submitted to the owner for written approval prior to fabrication. No more than two rows of letters are permitted provided their overall height does not exceed the height of the "net sign area". See exhibit A attached. Tenants shall display only their established trade name or their basic production name or combination thereof. All penetrations of the building structure required for sign installation shall be sealed in a watertight condition and shall be patched to match adjacent finish when removal takes place. D.) Design Criteria1 Building B 1. All sign designs shall be subject to the approval of the owner. 2. Wording of signs shall not include the product sold except as part of tenants trade name or insignia. 3. No more than two rows of letters are permitted provided their over- all height does not exceed the height of the "net sign area". 4. Signs shall be located on the building fascia within the Itnet sign area." See exhibit A attached. 3 5. Signs shall be centered vertically on the building fascia as indicated on exhibit A. The maximum vertical dimension of the "net sign area" shall not exceed 18". 7, Letters shall be centered horizontally on the lower band between the vertical column lines. Minimum clearance between the Sign and the column lines shall be 36" or a total of 26 lineal feet. As per exhibit A. E.) Construction Requirements Building B 1. All letters shall be installed utilizing aluminum 10-24. No visible clips or fasteners shall be permitted. 5. Tenant shall be fully responsible for the operations of tenant's sign contracotrs. General Sign Specifications For Buildings C, D, E, F, G, H, I 1. Each tenant shall have one required I.D. sign located as per drawing exhibit C . 2. Tenant sign shall consist of individual non-illuminated 3-D letters affixed directly to building fascia (exhibit C). 3. Letters are fabricated from .50" plexiglass attached to building fascia with clear silicone adhesive. 4. All letters shall have painted finish to match duranodic #313. Paint shall be lacryl manufactured by Spraylat f20-55 or equal. 5. The ltcopyll, letter style and logos shall be submitted to the owner for written approval prior to fabrication. 6. No more than two rows of letters are permitted provided their overall height does not exceed the height of the %et sign area" as per exhibit C. 4 7. Tenants shall display only their established trade name or basic production name or combination thereof. 8. Tenant is responsible for repair of all surfaces damaged by adhesives in the event of removal of letters. Building fascia shall be returned to original condition. G.) Design Criteria for Buildings C,D,E,F,G,H,I 1. 2. 3. 4. 5.0 6. 7. All signs shall be subject to the approval of the owner. Wording of signs shall not include the product sold except as part of tenants trade name or insignia. The maximum vertical dimension for individual letters shall be 8". Two rows of letters are permitted provided their overall height does not exceed 14" (exhibit C). Signs shall be centered on lower band of building fascia above entrance only as per exhibit C. Signs shall be centered horizontally on the lower band between the vertical column support and edge of building wall with a minimum clearance of 12" or a total of 8 linear feet per exhibit C. When two spaces are used, lettering shall be centered above vertical column support on lower band only with a minimum clearance of 24" on each side for a total of 16' linear feet. H.) Prohibited Signs 1. 2. 3. Sians Constitutina a Traffic Hazard: No person shall install or maintain or cause to be installed or maintained any sign which simulates or imitates in size, color, lettering or design any traffic sign or signal, or which makes use of the words YSTOPff, lfLOOK!' , "DANGERff, ort"any other words, phrases, symbols, or characters in such a manner to interfere with, mislead or confuse traffic. Immoral or Unlawful Advertising: It shall be unlawful for any person to exhibit, post or display or cause to be exhibited, posted or displayed upon any sign, anything of an obscene, indecent, or immoral nature or unlawful activity. Signs or Doors, Windows or Fire Escapes: No window signs will be permitted except as noted herein. No sign shall be installed, relocated, or maintained so as to prevent free ingress to or egress from any door. 5 4. 5. 6. Animated, Audible or Moving Signs: Signs consisting of any moving, swinging, rotating,~ flashing, blinking, scintillating, fluctuating or otherwise animated light are prohibited, except for time and temperature displays. Off-Premise Signs: Any signs, other than a directional sign, installed for the purpose of advertising a project, event, person or subject not related to the premises upon which said sign is located, is prohibited. Vehicle Si=: Signs on or affixed to trucks, automobiles, trailers, or other vehicles which advertise, identify, or provide directions to a use or activity not related to its lawful making of deliveries of sales or merchandis €/ or merchandise or rendering of services from such vehicles, is prohibited. I.) Miscellaneous Notes 1. The provision of this exhibit, except as otherwise expressly provided herein, shall not be applicable to the identification signs of occupancies designated by the landlord as .. "major" or "special" tenants that,may be located in the center, it is understood and agreed that these occupants may have their usual sign on similar buildings operated by them in California, provided however, there shall be no rooftop signs that flash, move or are audible and provided szid sign is architecturally compatible and has been approved by the owner.. 3 6 Exhibit A Building "B" Elevation Store Front Net Sign Area Letters shall not exceed vertical height of 14" Two rows of letters are permitted but shall not exceed a combined height of more than 18" Letters shall not be centered vertically and horizontally on the lower horizontal band only with a total of 26' linear feet. Letters shall conform to specifications in Exhibit B. Exhibit B - Letter Specifications Illuminated Signs 1. 2. 3. 4. 5. 6. Illuminated signs shall consist of individual reverse channel fabricated plexiglass letters with low voltage lfhalolf illumination as manufactured by RB SIGNWGRAFICS. Letters shall be fabricated of 1/8" thick acrylic plastic. Thermal-formed or vacuum-formed letters shall not be allowed. The use of trimcap is also prohibited. Illumination shall be achieved by use of 12 volt low voltage aircraft instrumentation lamps mounted, wired, and scaled in 'Tparallellr on a flexible U.L. rated ribbon. Lamps shall have a l'military spec" life rating of not less than 60,000 hours. Transformers shall be class 2 U.L. rated 12 volt transformers. Lamp spacing shall not exceed 1 1/2" on center and shall be layed out and positioned accordingly to achieve a uniform and balanced halo of light around the perimeter of each letter. Intensity of illumination shall be equal throughout the entire sign and shall be equal to the other signs within the center. Lamps shall be completely hidden from view, even when viewed from extreme oblique angles. All letters shall have an edge or return depth of 1 1/8" and shall be pegged off the wall 3/8 of an inch. Non-Illuminated Signs 1. Non-illuminated signs shall consist of individual reverse channel fabricated plexiglass letters as manufactured by RB SIGNS/GRAFICS. 2. Letter shall be fabricated 1/8" thick acrylic plastic. Thermal- formed and vacuum-formed letters shall not be allowed. The use of trimcap is prohibited. 3. All letters shall have an edge or return depth of 1 1/8?l and shall be pegged off the wall 3/8 of an inch. Exhibit C Building C,D,E,F,G,H,I Typical Front Entrance Letters shall not exceed a vertical height of 8" Two rows of letters are permitted but shall not exceed a vertical height of 14" Letters shall be centered on lower horizontal band as shown above One Store front Total 8' Linear feet centered between column & edge of wall Two Store front Total 16' Linear feet centered above column 3-D Letters are fabricated from .50 plexiglass & painted to match duranatic #313 Letters must conform to specifications on pg.3 section F&G. 8 ,