Loading...
HomeMy WebLinkAboutPS 90-16; Carlsbad Pacifica Office Building; Sign Permits/Programs (PS)City of Carlsbad 2075 Las Palmas Drive Carlsbad, CA 92009 (619) 438-1161 SIGN REC'D BY DATE 2RAo SIGN FEE $2!!.0d - t 9nm. RECEIPT NO. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS. Average processing Time: 2 weeks NAME OF PROJECT: Carlsbad Pacifica Office Building ADDRESS OF PROJECT: 5050 Avenida Encinas First Hotel Investment Corporation NAME AND PHONE NUMBER OF APPLICANT: C/o Westinghouse Credit Corporation 10 Main Street, Suite 1080 PLANNING CASE NUMBER: SZ%-/6 ::vine, CA 927 14 Attn: Candace Thorso SIGN TYPE: (a) Commercial (b) Industri a1 (c) Residential 7 14/833-2312 (e) Real Estate (e) Freeway (f) Marquee Community identity (h) Service Stn. Prices ( I) Campaign Yes X NO SPECIFIC PLAN NUMBER VILLAGE REDEVELOPMENT AREA Yes No - **REQUIRES VR APPROVAL SIGN ORDINANCE: Yes No - x COASTAL ZONE: Yes No /COASTAL PERMIT Yes No - EXISTING SIGNS: TvPe Number - Size (a) Pole (b) Monument (c) Wall PERMITS ISSUED FOR EXIST BUILDING FRONTAGE: (Bui EXISTING SIGNS (SQ. FT.) REMAINING SIGN ALLOWANCE PROPOSED SIGN: REMAINING SIGN ALLOWANCE ING SIGNS: lding street (AT PRESENT (AFTER THIS Yes - frontage) ') : SIGN) : 707-m&GWs aw Date ft. sq. ft. sq. ft. sq. ft. sq. ft. PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Specific Plan criteria, if applicable. 4. Location: In right-of-way In visibility triangle at corner On roof visibility issues. 5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for APPROVED: P1 anner : Date: CITY OF CARLSBAD 1200 ELM AVENUE CARLSBAD, CALIFORNIA 92008 438-5621 ACCOUNT NO. DESCRIPTION AMOUNT I I ~~ I TOTAL . . . .. . . . .. . . . . . . . . . . . BUILDING SIGN CRITERIA 5050 Avenida Encinas Carlsbad, California This criteria establishes the uniform policy regarding signage for all tenants of the above referenced building. These requirements, specifications and notes have been established for the purpose of maintaining the overall appearance of the project. All signs shall conform to the followin provisions of this sign criteria and shall be subject to written approval from the Land k ord and the City of Carlsbad. Signs which are installed without Landlord and City approval shall be subject to removal at the expense of the Tenant. All building signs require a sign permit from the City of Carlsbad. A. GENERAL REQUIREMENTS 1. A drawing of the size and location of approved signage is shown attached. The cost of the sign and installation shall be paid for by the Tenant. 2. Landlord and City of Carlsbad shall approve all sign design and placements prior to installation of the sign. 3. Tenant shall be responsible for fulfilling all of the requirements, specifications and general notes in this criteria. B. GENERAL SPECIFICATIONS 1. 2. 3. 4. 5. 6. 7. 8. Letter style shall be "Friz Quadrata," bold (chart-pax Style #236) upper and lower case. Letter height shall be a maximum of 42 inches. Total maximum sign area for the building shall be 264 square feet. No individual sign shall exceed 100 square feet. Letters shall be interior illuminated, individual channel letters with white plexiglass faces. Channel letter returns and trim cap to match #313 duranotic, dark bronze. Logos are to be aligned to the bottom edge level of any letters in the sign. Logos to be constructed with the same colors and materials used for the letters. No rotating or audible signs are allowed. Upon removal of any sign, damage to the building will be repaired at the Tenant's cost. Except as provided herein, no advertising placards, banners, pennants, names, insignia, trademarks, or other descriptive signs shall be affixed to or maintained upon any glass panes, landscape area, streets, or parking areas. Building monument signage, if any, shall conform to City and State Sign Codes and shall not exceed 20 square feet on one side of a double-faced sign. . C. GENERAL NOTES: 1. Prior to installation of any signage, the sign contractor shall carefully and thoroughly examine the building to field verify all conditions, demensions and other factors affecting the installation of the sign. Discrepancies and/or conditions, which are found to be different from those found in the building construction drawings, shall be reported to the owner’s field representative and architect prior to commencement of installation. 2. The Landlord relies on the fact that the sign contractor is a licensed specialist in his trade and shall therefore use diligence to protect the building from damage. Furthermore, contractor shall notify the architect in writing regarding work to be performed according to drawings or specifications for the signage which in the contractor’s opinion cannot be fully aranteed or constructed as designed according to Tenant’s and Land Y ord’s specifications. 3. In the case that installation detail in not clearly shown for any part of the work, materials and procedures shall be equivalent to professional standards for high uality work. The architect shall be notified immediately in writing o 9 any alternate non-standard or untested methods proposed. 4. All construction, fabrication and installation shall conform to the most recent City of Carlsbad Building Codes and any federal, state, county, or other code regulations or ordinances of governmental agencies with jurisdiction over signage at this location. 5. The sign contractor shall be responsible for com lying with all State of California Occupational Safety and Health Act i equlrements and Regulations in performing its work on this project. 6. The signage contractor shall comply with all State of California Safety Codes. 7. The Tenant shall obtain all required permits for the signage work and shall pay for the same. 8. Sign contractor shall be responsible for scheduling with the Landlord’s field representative for access to the building. 9. All work shall be performed when weather conditions permit satisfactory results and protect the building from water damage. 10. Contractor to field verify all dIrnensions at signage locations prior to commencement of installation. ENT CORPORATION DATE: 3/7,/’?0 2* , : t c RUILDX~G SIGN KICATIONS "" """ "