Loading...
HomeMy WebLinkAboutPS 90-75; Choice Autos; Sign Permits/Programs (PS)City of Carlsbad 2075 Las Palmas Drive Carl sbad, CA 92009 (619) 438-1161 SIGN po -3 f REC‘D BY DATE %/7/9P SIGN FEE $25.00 PC*-& SIGN PROGRAM FEE $150.00 SIGN PERMITS RECEIPT NO. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS. Average processing Time: 2 weeks &.,a ice A && s PLANNING CASE NUMBER: 70- -)c Todd, ke, b4.7- SIGN TYPE: (a) Commercial (b) Industrial (c) Residential (e) Real Estate (e) Freeway (f) Marquee (9) Community identity (h) Service Stn. Prices (I) Campaign SIGN PROGRAM AND/OR GTy SPECIFIC PLAN CRITERIA: Yes X NO SPECIFIC PLAN NUMBER VILLAGE REDEVELOPMENT AREA Yes No X **REQUIRES VR APPROVAL SIGN ORDINANCE: Yes No Y COASTAL ZONE: Yes No x. /COASTAL PERMIT Yes EXISTING SIGNS: Tvoe Number - Size No - (a) Pole (b) Monument (c) Wall ds PERMITS ISSUED FOR EXISTING SIGNS: Yes No X Date TOTAL BUILDING STREET FRONTAGE 16 ft. TOTAL SIGNAGE ALLOWANCE 5.T sq. ft. EXISTING SIGNAGE (SQ. FT.) as sq. ft. REMAINING SIGN ALLOWANCE AT PRESENT 5.T sq. ft. PROPOSED SIGNAGE (SQ. FT.) 5.3 sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ,a sq. ft. fANNER CHECK LIST: Field check by planner. Within maximum length, area. Style consistent with Specific Plan criteria, if applicable. PYt 4. Location: In right-of-way In visibility triangle at corner On roof visibility issues. b/A 5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for APPROVED: P1 anner: Date: + - lo- j% -. specializing in Real €state & Development industries NCD SIGNS P.O. Box 4274 220 LViscon;in Ave Oceanside, CA 92054 Skip McKee 220 Wisconsin Ave Sales Representative Oceanside, CA 92054 CHOICE AUTOS 8- \ w V A, PC m C D 1576 S.F. 1476 SF. 0 8 16 '! BUILDING c FLOOR PLAN 5 Fxhfhit C I i Building C.D,E,F.C,H,L Typical Front Entrance Letters shall not exceed a vertical height of 8" Two reus of letters are permitted but shall - not exceed a vertical height of 14" Letters shall be centered on lover horizontal band as shovn above .q , One Store front Total 8' Linear feet centered betveen colurm 6 edge of val'h Tm Store front Total 16' Linear 'feet centered above coiupn 3-D Letters are fabricated from -50 plexiglass 6, painted to ratch duranatic 1313 Letters must conform to specifications on pg.3 section FM;. 5. Signs shall be centered vertically on the bu1ldLr.g <33::3 39 indicated on exhiblt A. The maximum vertlcal J~rzer!3~2,n 2:- ::? "net sign area" shall not exceed 16". 6, The maximum vertical dimension for individual letters shall Se 14". 7. Letters shall be centered horizontally on the lower band becheer the vertical column linea. Minimum clearance between the 3:jr and the column linea shall be 36" or a total of 26 1:nea: fed;. As per oxhibi t A . E,) Construction Requirements Building 8 1. All letters shall be installed utilfzlng alwolnum IC-24, So visible clips or fasteners shall be permitted. 2. All penetrations of the building structure required for si&n installation shall be neatly sealed in a uatertighc condLtiQn, free Of li6ht leqka, 8 3. No labels will be permitted on the exposed surface of the 1:s:: except those required by local ordinance which shall Se a?,"::sz in an inconspicuous location. 5* Tenant shall be fully responsible for the operations of tezan:'s sign contracotrs, F,) General Sign Specifications For Buildings C, D, E, F, C, y, I 1. Each tenant shall have one requlred I.D. sign located as per ;~S,.;?,S exhibit C. 2. Tenant aign ahall consist of' Individual non-illuminated 3-3 :e::clrs affixed directly to building fascia (exhibit C) . 3, Letters 8re Fabricated from .50" plexiglass sttached i3 3u::G:r.,- Fascia with clear silicone adhesive, 4, All letters shall have painted finish to match durar.od:c 1,313, Paint shall be lacryl manufactured by Spraylat U20-55 3r eqsa:. 5, The 'kopytVr letter style and logos shall be submltted to tP,e owner for written approval prior to fabrication, 4 7. Tenants ghall display only their established trade name or basic production name or combination thereof, adhesives in the event of removal of letters. Building fascia shall be returned to original condition. 8. Tenant is responsible for repair of all surfaces damaged by 0,) Design Criteria for Buildings C,D,E,F,G,H,I 1, 2. 3. 4, 5. * 6. 7. All signs shall be subject to the approval of the Owner, Wording of signs shall not include the product sold except as part of tenants trade name or insignia. The maximum vertical dimension for individual letters shall be 8It, Two row$ of letters are permitted provided their overall height does not exceed 14" (exhibit C). Signs shall be centered on lower band of building fascia above entrance only as per exhibit C. Signs shall be centered horizontally on the lower band between the vertical column support and edge of building wall with a minimurn , clearance of 12" OF a total of 8 linear feet per exhibit C. When two spaces are used, lettering shall be c'entered above vertical column support on lower band only with a minimum clearance of 24" on each side for a total of 16' linear feet, Ha) Prohibited Signs 1. 2, 3. Signs Constituting a Traffic Hazard: No person shall install or maintain or cause to be installed or maintained any sign which simulates or imitates in size, color, lettering or design any traffic sign or signal, or which We3 US8 of the words ltSTOPtt, ttLOOKtt, ItDANGERt1, or"any other words I PhrlSe9 symbols, or characters in such a manner to interfere with, mislead or confuse traffic. Inunoral or Unlawful advert is in^: It shall be unlawful for any person to exhibit , post or display or cause to be exhibited, posted or displayed upon any sign, anythin5 of an obscene, indecent, or immoral nature or unlawful activity, Signs or Doors , Windows or Fire Escapes: No window signs will be permitted except as noted herein. No si83 * shall be installed, relocated, or maintained so as to prevent free! ingress to or egress from any door, Exhibit 8 - Letter Specifications Illuminated Signs 1. 2. 3. 4, 5. 6. Illuminated signs shall consist of individual reverse chamel fabricated Plexiglas8 letters with low voltage tlhalotl illumination as manufactwed by RB SIGNS/GRAFICS, Letters shall be fabricated of 1/8" thick acrylic plastic, Thermal-formed or vacuum-formed letters shall not be allowed. The use of trimcap is also prohibited, Illumination shall be achieved by use of 12 volt low voltage aircraft instrumentation lamps mounted, wired,'and scaled in llparalleltt on a flexible U.L. rated ribbon. Lamps shall have a ttmllltary spec" life rating of not less than 60,000 hours, Transformers shall be class 2 U,L, rated 12 volt transformers. Lamp spacing shall not exceed 1 1/2" on center and shall be layed out and positioned accordingly to achieve a uniform an2 balanced halo of light around the perimeter of each letter, Intensity of illumination shall be equal thmughout the entire sign and shall be equal to the other signs within the center. Lamps shall be completely hidden from view, even when viewed from extreme oblique angles. All letters shall have an edge or return depth of 1 1/8" and Shall be pegged off the wall 3/0 of an inch, Non-Illuminated Signs 1, Non-illuminated signs shall consist of individual reverse channel fabricated plexiglass letters as manufactured by RB SIGNWGRAFICS. 2. Letter shall be fabricated 1/89 thick acrylic plastic, Thermal- formed and vacuum-formed letters shall not be allowed. The use of trimcap is prohibited. 3. All letters shall have an edge or return depth of 1 1/8" and ahall be pageed off the wall 3/8 of an inch,