HomeMy WebLinkAboutPS 97-81; Carl's Jr.; Sign Permits/Programs (PS)City of Carlsbad
2075 Las Palmas Drive
Carlsbad, CA 92009
(619) 438-1 161
PLANNING DEPARTMENT
REVIEW FOR SIGN PERMITS
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to
the property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding signs.
5. Provide an elevation for all proposed signs which specifies the following:
A.
B.
C. Proposed sign copy.
Dimensions and area for all existing and proposed signs.
Materials the sign(s) will be constructed of.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
Average processing Time: 2 weeks
(,ar/'s Jr. 1 NAME OF PROJECT:
ADDRESS OF PROJECT: 9as Pdma r A 1 rpo rt U.
ASSESSOR PARCEL NUMBER: ](-05O-U6 - UO
RELATED PLANNING CASE NUMBER(S): sb P 9b-os
SIGN TYPE: ( ) Commercial (b) Industrial (c) Residential
d) Real Estate (e) Freeway (f) Marquee
(g) Community identity (h) Service Stn. Prices (i) Campaign Q
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA Yes - No - SPECIFIC PLAN NUMBER
VILLAGE REDEVELOPMENT AREA Yes - No - **REQUIRES VR APPROVAL
SIGN ORDINANCE: Yes - No -
COASTAL ZONE: Yes - No /COASTAL PERMIT Yes - No -
FRMOOOlO 2/96 Page 1 of 2
c Number - Size (in square feet) EXISTING SIGNS:
(a) Pole
(b) Monument i 3a3
(c) wall -
TOTAL BUILDING STREET FRONTAGE Yo ft. TOTAL SIGNAGE ALLOWANCE 60 sq. ft.
EXISTING SIGNAGE (SQ. FT.) CB sq. ft.
REMAINING SIGN ALLOWANCE AT PRESENT 60 sq. ft. PROPOSED SIGNAGE (SQ. FT.) bo sq. ft. - sq. ft.
PERMITS ISSUED FOR EXISTING SIGNS: Yes AdLC Date
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
OWNER
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION
IS TRUE AND CORRECT To THE BEST OF
MY KNOWLEDGE
SIGNATURE DATE
APPLICANT
NAME (PRINT OR TYPE)
Terry b; JqQYd
I CERTIFY THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE
INFORMATION IS TRUE AND CORRECT TO THE BEST OF
DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3.
4. Location: In right-of-way
Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
In visibility triangle at comer
On roof
5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner: Date: /q ,/.?
FRMOOOlO 8/92 Page 2 of 2
SPACING TABLE
VOLTAGE A 0 C BE WITHIN SIGHT OF SIGN (SIGN INCLUDES TRANSFORMER ENCLOSURE) 1001T05000 1/2lNCH 1/2lNCH NONE - REF: NEC 11 0-3 (E). 600-2.600-4
38' MlNlMUU LISTED CONDUIT 10001 TO 15000 1 INCH 1 INCH . 7500v+
34 INCH 3'4 INCH (14 INCH IF --
LISTED SIGN SECTION
D
3'4 INCH
1 1/8 INCH
1 1R INCH
(CONSISTS OF INSULATING BOOTS. INSUWTING SLEEVES, PLASTIC FACE. TUBE STANDS
--
REVOhlE @PO
SCALE. WNE
c
UL48-TlD IRE' ,
LOCATION UNLESS MARKED SUITABLE FOR OUTDOOR
FOR INDOOR ONLY.
ANDCHANNEL'LETTER)
\ TUBE STAND
NEON TUBE -
\r PLASTIC FACE
ELECTROCE INSULATING/
, EOOT. GTO INSULATING SLEEVE PROVIDED
LETTER HEIGHT VARIES
WITH SIGN
CONDUIT LOCKNUT
SPACINGS MAINTAINED
PER TABLE
t
L BONDING JUMPERS (ais AWG cu MINI WITH LISTED CONNECTION DEVICE OR FITTING REOUIRED IF (1) ALL FLEXIBLE METAL CONDUIT IN INSTALLATION USED AS A
GROUND RETURN PATH EXCEEDS 6 FT. (REF NEC 350-5 EXC. 2). OR (2) CHANNEL LETTER IS NON METALLIC. REF. NEC 250-43(9). 250-1 13. AND 600-5 INSTALLATION OF SIGNS LISTED PER UL48 NOTE: INSTALLATION REQUlREhlENTS ONLY. LISTING
WALL VARIES IN THICKNESS AND
i MATERIAL
LISTING MARKS:
1. LISTING MARK SIGN SECTION LABEL SHALL BE ON EACH LETTER AND TRANSFORMER ENCLOSURE.
@LISTED V
la nmei rcl&lcd
THE FIRST BLANK SPACE IDENTIFIES THE NUMBER OF EACH SIGN SECTION. THE SECOND BUIK SPACE INDICATES THE TOTAL NUMBER OF SIGN SECTIONS.
iesonp~abas~oyi~
ELECTRIC SIGN SECTION
No. xx-123456 0~0,
REQUIREMENTS CONTAINED IN UL48
ILLUMINATED CHANNEL LEUER
INSULATING BOOT AND SLEEVE
DRAWN er: ISSUE OA1E NEON INSTALLATION MANUAL
16" (O.A.H.) Copy I H I- 4'-3 i 1/4"
d 0
3 c - c
k
SIGN PERMIT NO. PS 97. 1
D/F INTERNALLY ILLUMINATED MONUMENT SIGN SMS-4
CABINETS:
FABRICATED ALUMINUM/SHEET METAL, 16" DEEE
FINISHED DARK BRONZE (RETAINERS 1 1/2 "WIDE)
FACES:
WHITE LEXAN WITH FIRST SURFACE VINYL GRAPHICS
AND PLANT-ON FORMED STAR W/RED
VINYL FEATURES (230-73)
I
SIGN FACE-RED VINYL BACKGROUND (230-73) W/ WHITE BORDER.
"CARL3 JR."-COW PRECUT ON RED VINYL BACKGROUND (SHOW THKU
WHITE FACE) WITH MATE BLACK VINYL OVERLAY OUTLINE.
BASE:
3'H X 4%' X 12"D-SHEET METAL CONSTRUCTION-
HABRA SILVER GREY X 16
ED "SILVER SLIPPER" TO MATCH BUILDING
INTERNAL, H.O. FLUORESCENT LAMPS
MUST BE A KEY SWITCH THAT 14 NOT ACCESSIBLE 1 1/2" RETAINER
-1 1/0" WHITE TO THE PUBLIC.
WE51 ELEVATION
1.) FA6 & INSTALL INTERNALLY ILLUMINATED
36' CARL'S JR. FLAT STAR. FACE OUT OF
YELLOW #2037 PLEX. W/RED VINYL FEATURES (3630-73)
TRIMCAP: RED 3/4"
RETURNS: .OW ALUMINUM (WITH.063 BACKS),
5" DEEC FINISHED DARK BRONZE(EXAC1 COLOR MATCH
TO BE PROVIDED BY CKE)