Loading...
HomeMy WebLinkAboutPS 97-81; Carl's Jr.; Sign Permits/Programs (PS)City of Carlsbad 2075 Las Palmas Drive Carlsbad, CA 92009 (619) 438-1 161 PLANNING DEPARTMENT REVIEW FOR SIGN PERMITS All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding signs. 5. Provide an elevation for all proposed signs which specifies the following: A. B. C. Proposed sign copy. Dimensions and area for all existing and proposed signs. Materials the sign(s) will be constructed of. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing Time: 2 weeks (,ar/'s Jr. 1 NAME OF PROJECT: ADDRESS OF PROJECT: 9as Pdma r A 1 rpo rt U. ASSESSOR PARCEL NUMBER: ](-05O-U6 - UO RELATED PLANNING CASE NUMBER(S): sb P 9b-os SIGN TYPE: ( ) Commercial (b) Industrial (c) Residential d) Real Estate (e) Freeway (f) Marquee (g) Community identity (h) Service Stn. Prices (i) Campaign Q SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes - No - SPECIFIC PLAN NUMBER VILLAGE REDEVELOPMENT AREA Yes - No - **REQUIRES VR APPROVAL SIGN ORDINANCE: Yes - No - COASTAL ZONE: Yes - No /COASTAL PERMIT Yes - No - FRMOOOlO 2/96 Page 1 of 2 c Number - Size (in square feet) EXISTING SIGNS: (a) Pole (b) Monument i 3a3 (c) wall - TOTAL BUILDING STREET FRONTAGE Yo ft. TOTAL SIGNAGE ALLOWANCE 60 sq. ft. EXISTING SIGNAGE (SQ. FT.) CB sq. ft. REMAINING SIGN ALLOWANCE AT PRESENT 60 sq. ft. PROPOSED SIGNAGE (SQ. FT.) bo sq. ft. - sq. ft. PERMITS ISSUED FOR EXISTING SIGNS: Yes AdLC Date REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN OWNER I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT To THE BEST OF MY KNOWLEDGE SIGNATURE DATE APPLICANT NAME (PRINT OR TYPE) Terry b; JqQYd I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. 4. Location: In right-of-way Style consistent with Sign Program and/or Specific Plan criteria, if applicable. In visibility triangle at comer On roof 5. Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: Date: /q ,/.? FRMOOOlO 8/92 Page 2 of 2 SPACING TABLE VOLTAGE A 0 C BE WITHIN SIGHT OF SIGN (SIGN INCLUDES TRANSFORMER ENCLOSURE) 1001T05000 1/2lNCH 1/2lNCH NONE - REF: NEC 11 0-3 (E). 600-2.600-4 38' MlNlMUU LISTED CONDUIT 10001 TO 15000 1 INCH 1 INCH . 7500v+ 34 INCH 3'4 INCH (14 INCH IF -- LISTED SIGN SECTION D 3'4 INCH 1 1/8 INCH 1 1R INCH (CONSISTS OF INSULATING BOOTS. INSUWTING SLEEVES, PLASTIC FACE. TUBE STANDS -- REVOhlE @PO SCALE. WNE c UL48-TlD IRE' , LOCATION UNLESS MARKED SUITABLE FOR OUTDOOR FOR INDOOR ONLY. ANDCHANNEL'LETTER) \ TUBE STAND NEON TUBE - \r PLASTIC FACE ELECTROCE INSULATING/ , EOOT. GTO INSULATING SLEEVE PROVIDED LETTER HEIGHT VARIES WITH SIGN CONDUIT LOCKNUT SPACINGS MAINTAINED PER TABLE t L BONDING JUMPERS (ais AWG cu MINI WITH LISTED CONNECTION DEVICE OR FITTING REOUIRED IF (1) ALL FLEXIBLE METAL CONDUIT IN INSTALLATION USED AS A GROUND RETURN PATH EXCEEDS 6 FT. (REF NEC 350-5 EXC. 2). OR (2) CHANNEL LETTER IS NON METALLIC. REF. NEC 250-43(9). 250-1 13. AND 600-5 INSTALLATION OF SIGNS LISTED PER UL48 NOTE: INSTALLATION REQUlREhlENTS ONLY. LISTING WALL VARIES IN THICKNESS AND i MATERIAL LISTING MARKS: 1. LISTING MARK SIGN SECTION LABEL SHALL BE ON EACH LETTER AND TRANSFORMER ENCLOSURE. @LISTED V la nmei rcl&lcd THE FIRST BLANK SPACE IDENTIFIES THE NUMBER OF EACH SIGN SECTION. THE SECOND BUIK SPACE INDICATES THE TOTAL NUMBER OF SIGN SECTIONS. iesonp~abas~oyi~ ELECTRIC SIGN SECTION No. xx-123456 0~0, REQUIREMENTS CONTAINED IN UL48 ILLUMINATED CHANNEL LEUER INSULATING BOOT AND SLEEVE DRAWN er: ISSUE OA1E NEON INSTALLATION MANUAL 16" (O.A.H.) Copy I H I- 4'-3 i 1/4" d 0 3 c - c k SIGN PERMIT NO. PS 97. 1 D/F INTERNALLY ILLUMINATED MONUMENT SIGN SMS-4 CABINETS: FABRICATED ALUMINUM/SHEET METAL, 16" DEEE FINISHED DARK BRONZE (RETAINERS 1 1/2 "WIDE) FACES: WHITE LEXAN WITH FIRST SURFACE VINYL GRAPHICS AND PLANT-ON FORMED STAR W/RED VINYL FEATURES (230-73) I SIGN FACE-RED VINYL BACKGROUND (230-73) W/ WHITE BORDER. "CARL3 JR."-COW PRECUT ON RED VINYL BACKGROUND (SHOW THKU WHITE FACE) WITH MATE BLACK VINYL OVERLAY OUTLINE. BASE: 3'H X 4%' X 12"D-SHEET METAL CONSTRUCTION- HABRA SILVER GREY X 16 ED "SILVER SLIPPER" TO MATCH BUILDING INTERNAL, H.O. FLUORESCENT LAMPS MUST BE A KEY SWITCH THAT 14 NOT ACCESSIBLE 1 1/2" RETAINER -1 1/0" WHITE TO THE PUBLIC. WE51 ELEVATION 1.) FA6 & INSTALL INTERNALLY ILLUMINATED 36' CARL'S JR. FLAT STAR. FACE OUT OF YELLOW #2037 PLEX. W/RED VINYL FEATURES (3630-73) TRIMCAP: RED 3/4" RETURNS: .OW ALUMINUM (WITH.063 BACKS), 5" DEEC FINISHED DARK BRONZE(EXAC1 COLOR MATCH TO BE PROVIDED BY CKE)