Loading...
HomeMy WebLinkAboutRP 10-03; It's A Grind Coffee House; Redevelopment Permits (RP) (2)2744 Carlsbad Blvd., Carlsbad, CA 92008 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project: It's A Grind Address: 2744 Carlsbad Blvd. Carlsbad, CA 92008 VICINITY MAP SCALE: NTS <— SATELLITE MAP - SIGN LOCATIONS Aooount Manager: Mark Frank Designer: Act 'Vci^t^ii 1.50 Scale: AS NOTED Design No.: 10-01 -2393-02 Date: 01.06.10 Reg. No.: Revisions: R1 AD (1.50) 1/11/10 Add section details & Interior window signs. R2 AD (1.00) 1/12/10 Add specifications; Delete blade & Interior signage. FOR JOB CHECK DATE Acet. Mgr. FOR CONSTRUCTION PATE Acet. Mgr. Design Production FOR INSTAU ONLY PATE Acet. Mgr. Page: 01 Of: 06 SCALE: NTS This is an original unpublished drawing created by Superior Electrical Advertising, Inc. It is submitted for your approval, tt Is not to be stiown to anyone outside of your organization, nor Is it to be reproduced, copied or exhibited In any fashion. The changing of colors, sizes, materials or iBuminalion metiiod does not alter the design. Ownership of this design is held by Superior Electrical Advertising. Inc. Authorization to use this design In any fashion must be obtained in wriiing from Superior Electrical Advertising, Inc. ©SEA 2009 Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. (J> STOREFRONT ELEVATION (LEFT SIDE) - PROPOSED HALO-ILLUMINATED CHANNEL LEHERS & DUAL VIEW LOGO PLAQUE 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project: It's A Grind Address: 2744 Carisbad Blvd. Carlsbad, CA 92008 Account Manager: Mark Frank Designer: Scale: 1.50 AS NOTED Design No.: 10-01-2393-02 Date: 01.06.10 Reg. No.: Revisions: Rl AD (1.50) 1/11/10 Add section details & Interior window signs. R2 AD (1.00) 1/12/10 Add specifications; Delete blade & Interior signage. Scale: Approx. 3/8" = 1'-0' Quantity: One (1) Sign ••Lining— FOR JOB CHECK PATE Accl. Mgr. FOR CONSTRUCTION PATE Acet. Mgr. Design Production FOR INSTALL ONLY PATE Acet. Mgr. Page: 02 Of: 06 This is an original unpublished drawing created by Superior Electrical Advertising, Inc, It Is submitted for your approval. It Is notto be shown to anyone outside of your organization, nor is It to be reproduced, copied or exhibited In any fashion. The changing of colors, sizes, materials or Illumination method does not alter fhe design. Ownership ofthis design Is held by Superior Electrical Advertising, Inc. Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising, Inc. ©SEA 2009 Note; The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project: it's A Grind Address: 2744 Carisbad Blvd. Carisbad, CA 92008 Account Manager: Mark Frank Designer: Aet 'Vc6^Aci\ai6 1.50 Scale: AS NOTED Design No.: 10-01-2393-02 Date: 01.06.10 Reg. No.: Revisions: R1 AD (1.50) 1/11/10 Add section details & Interior window signs. R2 AD (1.00) 1/12/10 Add specifications; Delete blade & Interior signage. STOREFRONT ELEVATION (RIGHT SIDE) - PROPOSED HALO-ILLUMINATED CHANNEL LEHERS Scale: Approx. 3/8" = 1'-0" Quantity: One (1) Sign — ••.i.iniii— FOR JOB CHECK PATE Acet. Mgr. FOR CONSTRUCTION PATE Acet. Mgr. Design Production FOR INSTALL ONLY PATE Aat. Mgr. Page: 03 Of: 06 This Is an original unpublished drawing created by Superior Electrical /\dvertlsing, Inc. h Is submitted for your approval. It Is not to be shown to anyone outside of your organization, nor is It to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or Illumination method does not alterthe design. Ownership ofthis design Is held by Superior Electrical Advertising, Inc. Authorization to use this design In any fashion must be obtained in writing from Superior Electrical Advertising, Inc. ©SEA 2009 Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. 8'-5y4" 6'-11" 3"J3 IT'S A GRIND! CUSTOM FABRICATED HALO-ILLUMINATED REVERSE CHANNEL LETTERS & DUAL-VIEW LOGO PLAQUE Quantity: One (1) Sign Required SPECIFICATIONS: "Logo Plaque" LEHERS: 3" DEEP L.E.D. ILLUMINATED DUAL-VIEW CHANNEL PLAQUE WITH PUSH-THRU FACES: .080" ROUTED ALUMINUM FACE PAINTED TO MATCH DARK BRONZE METALLIC. LOGO TO BE Vl EXPOSED RETURN CLEAR ACRYLIC PUSH-THRU W/POPPY RED (3630-143) & SUNFLOWER (3630-125) TRANSLUCENT VINYL OVERLAY RETURNS: .063" ALUMINUM RETURNS PAINTED TO MATCH DARK METALLIC ILLUMINATION: WHITE L.E.D. ILLUMINATION WITH REMOTELY LOCATED TRANSFORMERS MOUNTING: LOGO PLAQUE TO BE PEGGED OFF FASCIA WITH 1" SPACERS 8'-9y4" Scale: 1" = 1'-0" a> SIDE VIEW DETAIL Scale: 1" = 1'-0" SPECIFICAriONS: "It's A Grind" LEHERS: 3" DEEP LE.D. ILLUMINATED REVERSE CHANNEL LETTERS FACES: .080" ALUMINUM FACES PAINTED TO MATCH DARK BRONZE METALLIC RETURNS: .063" ALUMINUM RETURNS PAINTED TO MATCH DARK BRONZE METALLIC ILLUMINATION: WHITE L.E.D. ILLUMINATION WITH REMOTELY LOCATED TRANSFORMERS MOUNTING: LETTERS TO BE PEGGED OFF FASCIA WITH 1" SPACERS QCOFFEE HOUSE B CUSTOM FABRICATED HALO-ILLUMINATED REVERSE CHANNEL LETTERS Quantity: One (1) Sign Required SPECIFICATIONS: LEHERS: 3" DEEP L.E.D. ILLUMINATED REVERSE CHANNEL LETTERS FACES: .080" ALUMINUM FACES PAINTED TO MATCH DARK BRONZE METALLIC RETURNS: .063" ALUMINUM RETURNS PAINTED TO MATCH DARK BRONZE METALLIC ILLUMINATION: WHITE L.E.D. ILLUMINATION WITH REMOTELY LOCATED TRANSFORMERS MOUNTING: LETTERS TO BE PEGGED OFF FASCIA WITH 1" SPACERS Scale: 1" = I'-O" (3> SIDE VIEW DETAIL Scale: 1" = I'-O" SIGN PERMIT NO. RP lO'0l> Bl'ILDING APPROVEpmr DATE /y^y yfy 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 Facsimile: 562.435.1867 wviw.superiorsigns.eom Project: It's A Grind Address: 2744 Carisbad Bivd. Carisbad, CA 92008 Account Manager: Mark Frank Designer: Att yg^^afna/g Scale: 1.50 AS NOTED Design No.: 10-01-2393-02 Date: Reg. No: 01.06.10 Revisions: Rl AD (1.50) 1/11/10 Add section details & interior window signs. R2 AD (1.00) 1/12/10 Add specrfications; Delete blade & Interior signage. FOR JOB CHECK PATE Acet. Mgr. FOR CONSTRUCTION PATE Acet. Mgr. Design Production FOR INSTALL ONLY PATE Acet. Mgr. Page: 04 Of: 06 This Is an original unpublished drawing created by Superior Electrical Advertising, Inc, It is submitted for your approval. It is not to be shown to anyone outside of your organization, nor Is It to be reproduced, copied or exhibited in any fashion. The changing of colors, sizes, materials or illumination method does not atter the design. Ownership ofthis design is held by Superior Electrical Advertising, Inc. Authorization to use this design In any fashion must be obtained in writing from Superior Electrical Advertising, Inc. ©SEA 2009 Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. L.E.D. REVERSE HALO ILLUIMINATED CHANNEL LETTERS ALUMINUM FACE MOUNTED 1" AWAY FROM WALL SURFACE REMOTE POWER SUPPLY SECONDARY POWER- -PRIMARY POWER TYPICAL WALL FRAMING TYPICAL WALL SURFACE CUSTOM FABRICATED ALUMINUM CHANNEL LETTER RETURNS COUNTER SUNK SCREWED TO CLEAR LEXAN ANGLE CLIPS LIGHT EMITTING DIODES (LEDs) —Q LOW VOLTAGE WIRING FROM LED TO LED ALUMINUM LETTER-FACES LEXAN BACK DRILLED HOLE THRU WALL FOR WIRE CONNECTIONS AND FILLED WITH SILICONE TO PREVENT WATER PENETRATION DISCONNECT TOGGLE SWITCH HANDY BOX THREADED NIPPLE AND COUPLING #10x3y2" DRIVE SCREWS MINIMUM THREE (3) PER LETTER OR AS REQUIRED PER FIELD CONDITIONS 1 V2" SPACERS REQUIRED ONE {^)V^ WEEP HOLE LOCATED AT ALL AREAS THAT MAY COLLECT WATER •DISCONNECT SWITCH AT FAR LEFT OR RIGHT OF END LEHER •VERIFY PLACEMENT PRIOR TO FABRICATION LETTER LAYOUT - PLAN VIEW NOT TO SCALE CLASS 2 LOW VOLTAGE WIRING NOTE: NO CONDUIT OR FLEX REQUIRED PER CLASS 2 LOW VOLTAGE WIRING GUIDELINES VENTILATION HOLES GALVANIZED TRANSFORMER BOX POWER SUPPLY DISCONNECT SWITCH GROUNDING WIRE PRIMARY #12 CONDUIT OR FLEX J-BOX PRIMARY ELECTRICAL (SUPPLIED BY OTHERS) PLEASE REFER TO THE NUMBERED ITEMS BELOW FOR INCORPORATED INSTALL INSTRUCTIONS. LISTED INSTRUCTIONS TO BE FOUND WITH ACTUAL SIGNAGE (NUMBERED ITEMS CORRESPOND TO SECTION DETAIL) ITEM NUMBER DESCRIPTION 1 LIGHT EMITTING DIODES (LEDs) 2 DISCONNECT SWITCH 3 THREADED NIPPLE AND COUPLING (FLEX CONNECTOR) 4 CLASS 2 LOW VOLTAGE WIRING (NO FLEX / CONDUIT REQUIRED) 5 GALVANIZED TRANSFORMER BOX 6 POWER SUPPLY 7 FLEX (FLEXIBLE CONDUIT) / LIQUID TIGHT CONNECTIONS 1 TYPICAL SECTION DETAIL - REVERSE HALO LED ILLUMINATED CHANNEL LETTERS SCALE: NTS ALTERNATE ATTACHMENT METHODS HARDWARE BUILDING CONSTRUCTION Note to All Contractors MINIMUM FASTENERS MASONRY WOOD METAL/ACM PLYWOOD/EFIS VA" BOLTS THRU WALL X X X REQUIRES BLOCKING BY INSTALLER VA" LAG BOLTS W/SHIELD X .... .... .... VA" LAG BOLTS .... X .... REQUIRES BLOCKING BY INSTALLER VA" TOGGLE BOLTS HOLLOW BLOCK ONLY .... X THRU BOTH PLYWOOD AND EFiS MATERIAL 120 Sign Voltage This sign is intended to tte installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project: It's A Grind Address: 2744 Carisbad Blvd. Carisbad, CA 92008 Account Manager: Mark Frank Designer: AttVc6hMi\,ciU 1.50 Scale: AS NOTED Design No.: 10-01-2393-02 Date: 01.06.10 Reg. No.: Revisions: Rl AD (l.SO) 1/11/10 Add section details & interior window signs. R2 AD (1.00) 1/12/10 Add specifications; Delete blade & Interior signage. — •••I.ll.llll— FOR JOB CHECK PATE Acet. Mgr. FOR CONSTRUCTION PATE Acet. Mgr. Design Production FOR INSTALL ONLY PATE Acet. Mgr. Page: 05 Of: 06 This is an original unpublished drawing created by Superior Electrical Advertising, Inc, It Is submitted for your approval. It Is notto be shown to anyone outside of your organization, nor is it to tie reproduced, copied or exhibited In any fashion. The changing of colors, sizes, materials or Illumination method does not alterthe design. Ownership ofthis design Is held by Superior Electrical Advertising, Inc, Authorization to use this design in any fashion must be obtained in writing from Superior Electrical Advertising, Inc. ©SEA 2009 Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications. L.E.D. DUAL ILLUMINATED CHANNEL LOGO PLAQUE ROUTED ALUMINUM FACE WITH ACRYLIC PUSH-THRU MOUNTED 1" AWAY FROM WALL SURFACE REMOTE POWER SUPPLY MAIN POWER GROUNDING WIRE SECONDARY POWER- -PRIMARY POWER -NEUTRAL WIRE TYPICAL WALL FRAMING TYPICAL WALL SURFACE CUSTOM FABRICATED ALUMINUM CHANNEL LETTER RETURNS COUNTER SUNK SCREWED TO CLEAR LEXAN ANGLE CLIPS ROUTED ALUMINUM FACE LIGHT EMITTING DIODES LOW VOLTAGE WIRING FROM LED TO LED W CLEAR ACRYLIC PUSH-THRU LEXAN BACK DRILLED HOLE THRU WALL FOR WIRE CONNECTIONS AND FILLED WITH SILICONE TO PREVENT WATER PENETRATION DISCONNECT TOGGLE SWITCH HANDY BOX THREADED NIPPLE AND COUPLING #10x3 72" DRIVE SCREWS MINIMUM THREE (3) PER LETTER OR AS REQUIRED PER FIELD CONDITIONS 1 Vz" SPACERS REQUIRED ONE (1)%" WEEP HOLE LOCATED AT ALL AREAS THAT MAY COLLECT WATER (LEDs) -Bl •DISCONNECT SWITCH AT FAR LEFT OR RIGHT OF END LEHER •VERIFY PLACEMENT PRIOR TO FABRICATION LETTER LAYOUT - PLAN VIEW NOT TO SCALE CLASS 2 LOW VOLTAGE WIRING NOTE: NO CONDUIT OR FLEX REQUIRED PER CLASS 2 LOW VOLTAGE WIRING GUIDELINES VENTILATION HOLES GALVANIZED TRANSFORMER BOX POWER SUPPLY DISCONNECT SWITCH GROUNDING WIRE PRIMARY #12 IN CONDUIT OR FLEX J-BOX PRIMARY ELECTRICAL (SUPPLIED BY OTHERS) PLEASE REFER TO THE NUMBERED ITEMS BELOW FOR INCORPORATED INSTALL INSTRUCTIONS. LISTED INSTRUCTIONS TO BE FOUND WITH ACTUAL SIGNAGE (NUMBERED ITEMS CORRESPOND TO SECTION DETAIL) ITEM NUMBER DESCRIPTION 1 LIGHT EMITTING DIODES (LEDs) 2 DISCONNECT SWITCH 3 THREADED NIPPLE AND COUPLING (FLEX CONNECTOR) 4 CLASS 2 LOW VOLTAGE WIRING (NO FLEX/ CONDUIT REQUIRED) 5 GALVANIZED TRANSFORMER BOX 6 POWER SUPPLY 7 FLEX (FLEXIBLE CONDUIT) / LIQUID TIGHT CONNECTIONS 1 TYPICAL SECTION DETAIL - DUAL- ILLUMINATED CHANNEL LOGO SCALE: NTS ALTERNATE ATTACHMENT METHODS HARDWARE BUILDING CONSTRUCTION Note to All Contractors MINIMUM FASTENERS MASONRY WOOD METAL/ACM PLYWOOD/EFIS VA BOLTS THRU WALL X X X REQUIRES BLOCKING BY INSTALLER VA" LAG BOLTS W/SHIELD X .... .... .... VA LAG BOLTS .... X .... REQUIRES BLOCKING BY iNSTALLER VA" TOGGLE BOLTS HOLLOW BLOCK ONLY .... X THRU BOTH PLYWOOD AND EFIS MATERIAL 120 Sign Voltage This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project: It's A Grind Address: 2744 Carisbad Blvd. Carisbad, CA 92008 Account Manager: Mark Frank Designer: Act '^^/toctiaii 1.50 Scale: AS NOTED Design No.: 10-01-2393-02 Date: 01.06.10 Reg. No.: Revisions: Rl AD (1.50) 1/11/10 Add section details & Interior window signs. R2 AD (1.00) 1/12/10 Add specifications; Delete blade & interior signage. FOR JOB CHECK PATE Acet. Mgr. FOR CONSTRUCTION PATE Acet. Mgr. Design Production FOR INSTALL ONLY PATE Acet. Mgr. Page: 06 Of: 06 This is an original unpublished drawing created by Superior Electrical Advertising, Inc. It is submitted for your approval. It Is not to be shown to anyone outside of your organization, nor is it to be reproduced, copied or exhibited In any fashion. The changing of colors, sizes, materials or Illumination method does not alter the design. Ownership of this design is held by Superior Electrical Advertising, Inc. Authorization to use this design In any fashion must be obtained in wriiing from Superior Electrical Adverlising, Inc. ©SEA 2009 Note: The Colors depicted here are a graphic representation. Actual colors may vary. See color specifications.