HomeMy WebLinkAboutRP 12-04; 7 Eleven Sign; Redevelopment Permits (RP)^ CITY OF
CARLSBAD
REVIEW FOR SIGN
PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
PLANNING
REC'D BY
DATE lfZ3//Z
APRLICATION # pJP 12-Q^
SIGN FEE
SIGN PROGRAM FEE
RECEIPT NO. TZ^oo^ftQ^^
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and
sign elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
NAME OF PROJECT: 1-eleven .
ADDRESS OF PROJECT
ASSESSOR PARCEL NUMBER: —r
RELATED PLANNING CASE NUMBER(S):
TYPE OF DEVELOPMENT:
(a) Residential (d)
(b) Commercial (e)
(c) Office/Industrial (f)
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA
Hotel/Motel (g)
Service Station (h)
Prof. Care (i)
Theater
Gov't/Church
Public Park
(j) Produce Stand
(k) Nursey
(I) P-U/OS Zone
YesD NoQ Specific Plan Number
VILLAGEREDEVELOPMENTAREA YesV| NoD Requires VR Approval
p-11 Page 1 of 4 Revised 07/10
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
Show building/s
P/L
\
Show all property lines P/L
Sight Distance Requirement
Show setbacks from all curbs
curb line
Sight Visibility Street Name(s)
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
15 -(o
16.6>
TOTAL BUILDING STREET FRONTAGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.) 12 >
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
sq. ft.
sq. ft.
sq. ft.
sq. ft.
sq.ft.
sq.ft.
p-11 Page 3 of 4 Revised 07/10
SIGN ORDINANCE: YesQ NoQ
COASTAL ZONE: Ye^ NoD
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole 1
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: YesQ NoQ
PROPOSED PERMANENT SIGNS:
Date
TYPE
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
Pole**
Monument**
Wall 1 1 18"
Suspended
Directional
Canopy
Freestanding**
(Project Identity)
PROPOSED TEMPORARY SIGNS:
TYPE
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
Construction**
For Sale**
Banner
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-
of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be
required for such proposed signs.
p-11 Page 2 of 4 Revised 07/10
PROPERTY OWNER APPLICANT
NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) c
MAILING ADDRESS MAILING ADDRESS
CITY AND STATE Zlf^^l'^^^^EPHONE CITY AND STATE ZIP TELEPHONE
^n^^m^^.rAf^ 04.92078 '^^> Gx:ic
M THE LEGAL OWNER
ABOVE INFORMATION IS
T TO THE BEST OF MY
I CERTIFY THAT
AND THAT ALL
IE AND CORR
)WLEDG6.
I CERTIFY THAT I AM THE REPRESENTATIVE
OF THE LEGAL OWNER AND THAT ALL THE
ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE.
DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: • In right-of-way • In visibility triangle at comer
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved route copy to De^a Entr
APPROVED: Planner: ...4-^ Date: f/^^fl^-
P-11 Page 4 of 4 Revised 07/10
8'-1 1/8"
1'-6"
NEW CHANNEL LETTER DISPLAY SCALE 1" = r-0"
MANUFACTURE AND INSTALL (1) NEW SET DF INTERNALLY ILLUMINATED PLEX FACE CHANNEL LETTERS
SHEET METAL SCREW
(#8 X PAINT TO MACH
TRIM-CAP
CONDUIT LOCKNUT
BACKS: .22 GAUGE SHEET METAL
RETURNS: .22 GAUGE SHEET METAL
TRIMCAP: 3/4" PMS BLACK
PAINT : PAINT EXTERIOR OF LETTERS GLOSS BLACK
FACES: WHITE PLEX WITH VINYL OVERLAY- VERIFY COLORS
ILLUMINATION: WHITE LED
SIGN PERMIT NO. RP [t-'-^'j
Rc4evelop«nt
BUILDING
APPIK>VEDBY DATE
PRIMARY ELECTRICAL FEED
(EXISTINGt
LISTED DISCONNECT
SWITCH IN PRIMARY
^.-J^^r"^ WALL (VERIFY)
I J ^ WASHERS
22 GA SHEET METAL
BACKS & RETURNS
1/4-WEEP HOLES
UL APPROVED INSTALLATION DETAIL
CHANNEL LETTER WITH LED & POWER SUPPLY SIA' = 1
INSTALL IN ACCORDANCE WITH THE NEC AND LOCAL ELECTRICAL COOES
WES T E R N TS S IBN
102Q LINDA VISTA DR.
SAN MARCOS Ca 92078
PH0NE:7B0.73B.6a"7Q
FAX:7BO.V36.Ba7'3
PROJECT TITLE
TOWER 37
7-ELEVEN
JOB LOCATION
201 OAK AVENUE
CARLSBAD.CA
THIS DESIGN IS THE EXCLUSIVE
PROPERTY OF WESTERN SIGN
& AWNING. IT MAY NOT BE
REPRODUCED IN WHOLE OR PART
WITHOUT WESTERN SIGN & AWNING S
WRITTEN CONSENT,
ALL PRIMARY ELECTRICAL TO SIGN
LOCATION TO BE PROVIDED BY OTHERS
DRAWN BY: MCASTANEDA
DATE: 1/12/12
PRESENTED BY:
Tiffany Del Gatto
CUSTOMER APPROVAL
DATE:
REVISION
SHEET: OF 2
FILE NUMBER
12-015
MEMBER OF
INTERNATIONAL SIGN ASSOCIATION
T-^V'A \
/y. Site Plan Demo Planting
^ r = io'-o"
CENTER LINE
FIRE HYDRANT ACROSS STREET ON CORNER OF /
OAK AVE & CARLSBAD
BLVD
CENTER LINE-
OAK AVENUE
(80' PUBLIC RIGHT-OF-WAY)
FIRE HYDRANT
150'AWAY ON
SOUTH SIDE OF
OAK AVE
Keynote Legend
Key Value Keynote Text
012
013
101
102
103
104
105
107
108
111
112
113
114
115
116
117
120
Cut curb for new ADA access walkway
slab
Repair (as needed) existing AC paving
in front of access point of side fenced
in yard down to drive and out to
sidewalk
Demo tree and root ball and refill with
top soil and reseed with grass to
match existing
New 5' wide Sidewalk - concrete
Repair existing concrete pad and
existing AC paving next to driveway
(as needed)
Deckcoating over existing walkway -
2% Max. slopage to face of sidewalk
New wood fencing on existing CMU
retaining wall
New wood framed wall on top of
existing CMU retaining wall and
anchor wood framing to existing remaining handrailing, wood sheathing
on each side with Eldorado stone work
all the way around retaining wall and
new frame wall, with stone cap
New parking stripping - white
New ADA parking Blue stripping (van 9' wide 18' long Min,) with 8' wide Blue
stripped side access with 12" high "NO
PARKING" stenciled in white and
accessibility symbol (white wheel chair
profile on blue background 36"x36") in
parking stall - 2% Max. slope in any
direction for parking stall and access
area
New accessibility access walkway blue stripping 5' wide - verify that there is
no more than a 2% cross slope
Line of roof overhang or projections
Relocated wheel stops
Accessible parking sign (van)
New poured concrete stairs and
handrails - 2" wide non slip warning strip (contrasting color to tread) running parallel to nosing, 1" from
tread nosing on all treads and top
landing
Parking lot to be restriped
Tree to be pruned - by other
New palm tree - by other
Existing utility pole
Genral Notes:
All property lines, easements and buildings, trath
existing and proposed, are shown on this site plan.
PLAN jpyE
NORTH NORTH
ATN Site Plan W 1" = io'-0"
ARCHITECT
Friendco, Inc .
Mail to P O Box 4067, Carlsbad, CA 92018-4067
studio @ 2691 Crest Drive, Carlsbad, CA 92008 PH: 760-729-5152, Fax 760-757-5152
E-mail kipmcbane@gmail com
PLANNER/DESIGNER
viy
Karnak Planning & design
2525 Pio PICO Drive, Suite 102, Carlsbad, CA 92006
Phone 760-434-8400, Fax 760-683-2269
E-mai! karnakarch@aol com
CONSULTANT
MADFI, LLC
7-11 Retail Center
Facade Remodel
201 Oak Avenue
Carlsbad, CA 92008
Site Plan
A-001
city of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
Applicant: TIFFANY DELGATTO
Description
RP120004
2 01 OAK AV CBAD
Amount
57.00
Receipt Number: ROOS8083
Transaction Date: 01/23/2012
Transaction ID: ROOS8083
Pay Type Method Description Amount
Payment Check 13292 57.00
Transaction Amount: 57.00