Loading...
HomeMy WebLinkAboutRP 97-06; Marriott Towneplace Suites; Redevelopment Permits (RP) (2)City of Carlsbad Planning Department April 13, 1998 Sandor W. Shapery Shapery Enterprises 1158 State Street Suite 100 San Diego, CA 92101 SUBJECT: RP 97-06 MARRIOTT TOWNEPLACE SUITES No action on your part has taken place on your application since your request to suspend processing of the application on October 3, 1997. As a result, this letter is notification to you that RP 97-06 has been withdrawn. Please contact Debbie Fountain at (760) 434-2810, extension 2935 with questions regarding the withdrawal. Sincerely, CHRISTER WESTMAN Associate Planner CWmh c: Debbie Fountain Gary Wayne Bob Wojcik Ken Quon Bobbie Hoder Don Rideout File Copy Data Entry 2075 La Palmas Dr. • Carlsbad, CA 92009-1576 • (760) 438-1161 • FAX (760) 438-0894 ® City of Carlsbad Planning Department October 27, 1997 Sandor W. Shapery Shapery Enterprises 1158 State Street Suite 100 San Diego, Ca. 92101 SUBJECT: RP 97-06 MARRIOTT TOWNEPLACE SUITES Dear Mr. Shapery: Pursuant to your notice of October 3, 1997, processing of your application for a Redevelopment Permit has been suspended as of the date of receipt (October 8, 1997). In addition, proposing a different site plan and elevations will constitute a new project and will require a second completeness review. Should you have any questions, please contact me at (760) 438-1161 extension 4448. Sincerely; CHRISTER WESTMAN Associate Planner CW-.kr Debbie Fountain Gary Wayne Ken Quon 2075 Las Palmas Dr. • Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894 0 Shapery Enterprises October 3, 1997 Ms. Deborah Fountain CARLSBAD REDEVELOPMENT AGENCY CITY OF CARLSBAD 2965 Roosevelt, Suite B Carlsbad, CA 92008-2389 Re: Redevelopment Perinit Application 97-06 Dear Deborah: We are currently considering developing a different brand extended stay hotel on the property located between Laguna, Grand, and Interstate 5. As a result, the configuration elevations and site layout will be different; so, I am requesting that you halt any further action on this application pending a reconfiguration and finalization of our plans. Thank you for your cooperation in this matter. Sincerely, Sandor W. Shapery SWS: 1158 State Sfreef • Suite 100 • Son Diego, CoiifornlQ 92101 • (619) 239-4700 FAX (619) 237-0191 Shapery Enterprises September 18, 1997 Ms. Deborah Fountain CARLSBAD REDEVLOPMENT AGENCY 2965 Roosevelt Street, Suite B Carlsbad, CA 92008-2389 Re: Carlsbad Village Suites - Marriott TownePlace Suites Development permit application no.: 97-06 Dear Deborah: On August 20, 1997, I submitted ten (10) sets of plans along with other required documents to obtain a permit to construct a 106-unit Marriott TownePlace Suites in Carlsbad adjacent to Interstate 5 between Grand and Laguna Avenues. Marriott Corporation has asked that the site plan and parking configuration be adjusted slightly. They want the 60-room building moved forward 18 feet to allow for an improved parking plan on both ends of the building and they have relocated the trash enclosure to the rear of the property next to the freeway off-ramp. Marriott also has several additional planting areas to break-up the long parking stalls. I have enclosed ten (10) copies of the revised site plan for your approval as we are requesting that this modified site plan replace the original one submitted on August 20, 1997. Please call if you need anything further. Sincerely, a- Sandor W. Shapery SWS:rp Enclosures 1158 State Streef • Suite 100 • San Diego, California 92101 • (619) 239-4700 FAX (619) 237-0191 Citv of Carls Planning D September 17, 1990 Gary Caywood Austin Nelson Company Inc. 1122 Melrose Drive Vista, CA 92083 Subject: Grand and Laguna Condominium Project APN: 203-13-15/18/20/24 Preliminary review of your project was conducted on September 7, 1990. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept ofyour project. The preliminary review does not represent an in-depth analysis of your proiect. Additional issues of concern mav be raised after vour application is submitted and processed for a more specific and detailed review. Plannina 1. Thirty foot driveways are required throughout the entire site. This includes the area leading to the garages. 2. The walls located in the required front yard setbacl<s should not exceed a height of 42 inches for aesthetics, safety and driveway visibility. 3. Noise, architectural treatment, and setback along the east building elevation adjacent to 1-5 are all issues of concern. No building elevations were provided for this elevation, therefore it is difficult to assess this aspect of the project. 4. With no openings to the freeway because of noise considerations, light and air for the internal units along the freeway becomes an issue. 5. Check with the Fire Department for confirmation that all the units could be served adequately with fire equipment. 6. The Planning Department has an Administrative Policy No. 24 which concerns the definition of a street and driveway within a Planned Residential Development The distinction between the two is made for the purpose of determining setback requirements. Private streets require a 20 foot setback from the edge ofthe street and driveways require a minimum of five feet from the edge of the driveway. Your eastern building along 1-5 obsen/es a five foot settiack where 20 feet is required from the internal street Before staff can deviate from the policy and recommend approval of the project, detailed findings must be made to justify the superiority of this design over another design that would meet the policy. 2075 Las Palmas Drive • Carlsbad. California 92009-4859 • (619) 438-1161 Gary Caywood September 17, 1990 Paae 2 Enaineerina 1. If you use an automatic gate you must provide a turnaround. 2. The emergency access and additional curb cut on Laguna will be permitted only if the Fire Department requires it If it is required, then the area for the emergency access should not be paved. Use "grass-crete" which will blend with the surrounding front yard landscaping. 3. A five foot back-up clearance is required at the end of the driveway and adjacent to Units 11/16 and Units 22/27 (see plans). Please contact me at 438-1161 if you have any questions. Sincerely, Jeff Gibson Associate Planner JG:n/o c: Erin Letsch Citv of Carlsbad Planning Department August 10, 1990 Michael E. Robinson/Robinson/Meixl Architects 616-B East Alvarado Street Fallbrook, CA 92028 Subject Grand & Laguna Condominium Project APN: 203-13-15, 18, 20, 34 Preliminary review of your project was conducted on August 10, 1990. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project The preliminarv review does not represent an in-depth analvsis of vour proiect Additional issues of concern mav be raised after vour application is submitted and processed for a more specific and detailed review. Plannina: 1. The project density of 11.66 du's/ac exceeds the Growth Control Point of 11.5 du's/ac which is the highest density allowed in this General Plan Designation (RMH). 2. Thirty foot driveways are required with a 5 foot setback to the building (this includes the decks) off the 30 foot driveway (see marked plans). 3. Pedestrian access to the street is required, (i.e. sidewalks along the driveway). 4. With 28 units, 10 guest spaces are required. 5. The lot is double fronted and buildings or decks should not encroach into the two 20 foot required front yard setbacks along Grand and Laguna. 6. Garages must measure 20' x 20' from the inside of the building wall. 7. A noise study is required and the City's Noise Policy applies to this project 8. Guest parking spaces must be located at least 5 feet from any dwelling units or structures. 9. For projects over 10 dwelling units, recreational vehicle parking must be provided at a ratio of 20 square feet for each dwelling unit Prelim.rev Form 2075 Las Palmas Drive • Carlsbad, California 92009-4859 • (619) 438-1161 irand & Laguna Condominium Project ^August 10, 1990 Paae 2 10. Need to show central refuse pickup areas. 11. The building elevations along the freeway should have plenty of visual and architectural interest On this building, the driveway elevations are too long and linear. Provide more offsets and insets or possibly a break in the building. This will provide more shading, relief and visual interest Enaineerina: 1. The through connection between cul-de-sacs will not be permitted. You cannot have access from both streets for one lot We will require that all lots be consolidated into one lot 2. You will probably be required to complete a temporary street drainage system along Grand Avenue to Hope (asphalt berm). 3. You need sidewalks on the interior private "streets". Please contact me at 438-1161 if you have any questions. Sincerely, Jeff Gibson Associate Planner JG;rvo c; Erin Letsch Prelim.rev Form r Citv of Carlsbad Housing & Redevelopment Department July 31, 1997 GREG FRIESEN 402 WEST BROADWAY 27TH FLOOR SANDIEGO, CA. 92101 RE: MARRIOTT TOWNEPLACE SUITES Dear Mr. Friesen: The following is in response to the correspondence you forwarded to my office, dated July 25, 1997 regarding the proposed Marriott Towneplace Suites on the site at the end of Grand Avenue and Laguna Drive, within the City ofCarlsbad. This correspondence provides some corrections to the information you received on July 24, 1997 from the Planning Department. I wanted to preface my comments by indicating that this project is slightly more complicated than most because two of the parcels proposed for development are inside the Village Redevelopment Area and two are outside. Properties within the Village Redevelopment Area must be developed according to the specific development standards outlined within the Village Master Plan and Design Manual. Attached is a copy of the standards which will apply to the subject project. A redevelopment permit is required for the subject project. Therefore, the project must be in compliance with the attached development standards in order to obtain approval. If the development standard can't be met, the applicant will be required to request a variance. Unfortunately, the Planning Department did not have a fmal copy of the Village Master Plan and Design Manual when you called on July 24, 1997. Therefore, the planner was not aware of the changes which had been made to the development standards. The standards attached represent the standards which have been approved for development in the Village Area. Height Limit: The height limit for the land use district in which the subject project is located is 35 feet with a minimum 5:12 roof pitch. To exceed this maximum height standard, a variance must be granted. To be granted a height variance, the Redevelopment Agency must find that the project height is I) visually compatible with surrounding buildings, 2) the increased height will not unduly impact nearby residential areas, 3) the taller project will not adversely impact views, 4) the project will maintain a scale and character compatible with the Village and the guidelines contained vvithin the Village Master Plan and Design Manual, and/or 5) the project provides for exceptional design quality and is consistent with the goals and objectives of the Village Redevelopment Area. 2965 Roosevelt St.. Ste. B • Carlsbad, CA 92008-2389 • (619) 434-2810/2811 • FAX (619) 720-2037 ® G. Friesen July 31, 1997 Page 2 At this time, it would be difficult to tell you if staff will support a variance for the height. We will need to review the completed plan to determine any potential impact on surrounding properties. It is important to note that the impact on the single family homes to the east of the sight will be considered in any decision to support a height variance. Set Backs: The set backs standards are provided in ranges to allow for some flexibility to accommodate desirable design features. Typically, the top of the range is the desired standard. However, a reduction in the standard to the minimum, or anywhere within the range, may be allowed if the project warrants such a reduction, and the appropriate fmdings are made by the approving body. The findings which must be made are included in the attached information. To go below the minimum or above the maximum, a variance must be approved with the appropriate findings. Please note again that there is no parking permitted within the front or rear set backs. Also, please note the open space requirements. Parking: No corrections to the parking information provided by Mike Grim. Engineering Comments: In a previous preliminary review of the project by the City's Engineering Department, comments were provided as related to access to the site and public improvements. I do not believe that this information had been previously provided to Mr. Shapery. Therefore, I am forwarding it to you at this time for review and consideration. If you have any questions regarding the above information, please contact my office at (760) 434-2935. Sincerely, DEBBIE FOUNTAIN Senior Management Analyst c: Planning, Mike Grim