Loading...
HomeMy WebLinkAboutSP 31A; Papagayo Development; Specific Plan (SP) (8)Final Noise Analysis For Ocean Pointe Building #6 CITY OF CARLSBAD Report #2001-128 August 29,2001 Preparedfor: Regis Homes L.P. 18825BardeenAve. Irvine, CA 92612 (949) 253-0455 Prepared by: Paul Dunholter, P.E. Theodore Lindberg, INCE Justin Cook BridgeNet, International 3151 Airway Ave. Building 1-2 Costa Mesa, CA 92626 (714) 540-3120 Final Noise Analysis Ocean Pointe Bldg. #6 Summary of Recommendations Final Noise Analysis for Ocean Pointe - Building #6 The proposed project must comply with the City of Carlsbad's interior noise standard of 45 dB CNEL. In order to comply with the interior noise standard, the proposed dwelling unit must provide sufficient outdoor-to-indoor noise attenuation to reduce the interior noise exposure to acceptable levels. Analysis shows that the worst case of noise exposure will be to those buildings, which are located adjacent to the SCRRA mainline. There were thirty-eight (38) rooms used for the interior analysis. These rooms included the living room, dining room, den, kitchen & nook, master bedroom, and second bedroom from Plans Al, A2, Bl, B2, Cl, C2, Dl, D2, and E2. With the construction details listed within the report, the interior noise levels of the rooms within Building #6, adjacent to the SCRRA mainline, were calculated to be as high as 48.8 dB CNEL, therefore upgrades will be required. Refer to Table SI for the specific upgrades required for Building #6 located adjacent to the SCRRA mainline. Table SI Building Upgrades for Ocean Pointe - Building #6 Plan A A Ar Ar B B B B C C C C C C C D D D D Unit 142, 242, 342 142, 242, 342 143, 243, 343 143, 243, 343 141.241.341 141.241.341 146,246,346 146, 246, 346 140, 240 140, 240 140, 240 145, 245, 345 145,245,345 145,245,345 145, 245, 345 144, 244, 344 144, 244, 344 144, 244, 344 144,244,344 Room Windows Living Room Master Bedroom Living Room Master Bedroom Master Bedroom Operable Living Room Master Bedroom Operable Living Room Living Room Fixed Living Room Bedroom 2 Living Room Fixed Living Room Bedroom 2 Master Bedroom Master Bedroom Operable Den Dining/Living Room Fixed Dining/Living Room Doors SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD Exterior Walls 2 2 2 2 2 2 2 2 2 2 1 2 2 1 2 2 2 2 2 Upgrade (EWNR/STC) 25/27 28/30 25/27 28/30 28/30 26/28 30/32 26/28 32/34 29/31 27/29 31/33 29/31 27/29 30/32 25/27 26/28 31/33 32/34 Final Noise Analysis Ocean Pointe Bldg. #6 Refer to the Appendix for the calculation of the EWNR values for each of the rooms used in the analysis. All rooms in the project will meet the City's 45 dB CNEL interior noise standard, assuming windows remain closed. Since the outdoor-to-indoor noise attenuation of a unit falls to about 12 dBA when the windows are open, any unit located within the 57 dB CNEL contour line will meet the 45 dB CNEL interior noise standard only with windows closed. Subsequently, all the units within Building #6, adjacent to the SCRRA mainline, will require some system which provides fresh air into the units when the windows are closed. The mechanical engineer for the project should show that the system chosen for the project complies with the fresh air requirements of the UBC. Final Noise Analysis Ocean Pointe Bldg. #6 Final Noise Analysis for Ocean Pointe - Building #6 City of Carlsbad 1.0 Introduction The purpose of this report is to demonstrate the compliance of Building #6, the Ocean Pointe project, with the City of Carlsbad's interior noise standard. This report is an addendum to "Exterior Noise Analysis for Ocean Pointe, Building #6, City of Carlsbad" report #2001-127 prepared by BridgeNet International, and dated August 22,2001. This report will address the interior noise exposure of the proposed living units based upon the exterior noise levels calculated in the aforementioned exterior noise analysis. This report does not include a review of, or specifications of, common party wall or floor ceiling assemblies. This report only addresses the City of Carlsbad's interior noise standards due to roadway noise. 2.0 Noise Criteria The City of Carlsbad's General Plan specifies outdoor and indoor noise limits for residential land uses. Both standards are based upon the CNEL index. CNEL, or Community Noise Equivalent Level, is a 24-hour, time-weighted, annual average noise level based on the A- weighted decibel. A weighting is a frequency correction that correlates overall sound pressure levels with the frequency response of the human ear. Time weighting refers to the fact that noise occurring during certain time periods is given more significance because it occurs at times when people are more sensitive to noise. In the calculation process, noise occurring in the evening time period (7 p.m. to 10 p.m.) is increased by 5 dB, while noise occurring in the nighttime period (10 p.m. to 7 a.m.) is increased by 10 dB. These time periods and increases were selected to reflect a person's increased sensitivity to noise during late-night and early morning hours. 3.0 Interior Noise Mitigation In order to comply with the 45 dB CNEL interior noise standard, the buildings must provide sufficient outdoor-to-indoor noise attenuation to reduce the interior noise to acceptable levels. The outdoor-to-indoor noise reduction characteristics of a building are determined by combining the transmission loss of each of the individual building elements. Each unique building element has a characteristic transmission loss. For residential units the critical building elements are the roof, walls, windows, doors, attic configuration and insulation. The total noise reduction achieved is dependent on the transmission loss of each of" these elements and the area of that element in relation to the total surface area of the room. Room absorption is the final factor used in determining the total noise reduction. Final Noise Analysis Ocean Pointe Bldg. #6 According to the exterior noise analysis for the project, the projected worst-case unmitigated noise level at the face of Building #6, adjacent to the SCRRA mainline, is expected to be 71.5 dB CNEL. Therefore, in order to meet the interior noise standard of 45 dB CNEL, the units in Building #6, located adjacent to the SCRRA mainline, must provide a minimum of 26.5 dB outdoor-to-indoor noise attenuation. When residential building attenuation requirements are greater than 20 dB, detailed engineering calculations are necessary to demonstrate the noise reduction characteristics of the building partitions. The following are constructions details that were used to determine the outdoor-to-indoor noise reduction of the living units: Roofs are Build-up roofing construction with an EWNR rating of 37. Exterior walls are wood stud construction with 7/8" stucco on the exterior and 1/2" gypsum drywall on the interior. All exterior walls include insulation in the stud cavities. Fixed windows were assumed to be 1/8 " single glazed with an EWNR rating of 26 (STC = 28). Sliding windows were assumed to 1/8 " single glazed with an EWNR rating of 22 (STC = 24). Sliding glass doors were assumed to be 3/16" single glazed with an EWNR rating of23 (STC = 25) All exterior doors are solid core and include weather-stripping with an EWNR rating of 26 (STC = 28). All exterior doors are solid core and include weather-stripping. In order to assess compliance of the project with the 45 dB CNEL interior noise standard, worst-case rooms for each building plans were selected for analysis. In general, the worst-case room is the second story corner room with the greatest amount of window area. Corner rooms have more exterior surface area, which allows for greater noise intrusion. Rooms with large window areas have the least amount of noise reduction, because windows typically are acoustically the weakest part of the structure. Based on the construction details and the Equivalent Wall Noise Rating (EWNR) values for each of the building elements, the total building noise reduction was calculated. There were a total of thirty-eight (38) rooms used for the interior analysis. These rooms included the living room, dining room, den, kitchen & nook, master bedroom, and second bedroom from Plans Al, A2, Bl, B2, Cl, C2, Dl, D2, and E2. With the construction details listed above, the interior noise levels of the rooms within Building #6, adjacent to the SCRRA mainline, were calculated to be as high as 48.8 dB CNEL. Final Noise Analysis Ocean Pointe Bldg. #6 Since this level exceeds the interior noise standard of 45 dB CNEL, building upgrades will be required. Refer to Table 1 for the specific upgrades required for Building #6 located adjacent to the SCRRA mainline. Table 1 Building Upgrades for Ocean Pointe - Building #6 Plan A A AT AT B B B B C C C C C C C D D D D Unit 142,242,342 142, 242, 342 143,243,343 143,243,343 141.241,341 141,241,341 146.246,346 146,246,346 140, 240 140,240 140,240 145,245,345 145,245,345 145,245,345 145,245,345 144,244,344 144,244,344 144,244,344 144,244,344 Room Windows Living Room Master Bedroom Living Room Master Bedroom Master Bedroom Operable Living Room Master Bedroom Operable Living Room Living Room Fixed Living Room Bedroom 2 Living Room Fixed Living Room Bedroom 2 Master Bedroom Master Bedroom Operable Den Dining/Living Room Fixed Dining/Living Room Doors SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD SGD Exterior Walls 2 2 2 2 2 2 2 2 2 2 1 2 2 1 2 2 2 2 2 Upgrade (EWNR/STC) 25/27 28/30 25/27 28/30 28/30 26/28 30/32 26/28 32/34 29/31 27/29 31/33 29/31 27/29 30/32 25/27 26/28 31/33 32/34 Refer to the Appendix for the calculation of the EWNR values for each of the rooms used in the analysis. With the aforementioned buildings installed, all of the rooms in the project will meet the City's 45 dB CNEL interior noise standard, assuming windows remain closed. Since the outdoor-to-indoor noise attenuation of a unit falls to about 12 dBA when the windows are open, regardless of building upgrades, any unit located within the 57 dB CNEL contour line will meet the 45 dB CNEL interior noise standard only with windows closed. Subsequently, all the units within Building #6, adjacent to the SCRRA mainline, will require some system which provides fresh air into the units when the windows are closed. The mechanical engineer for the project should show that the system chosen for the project complies with the fresh air requirements of the UBC. Final Noise Analysis Ocean Pointe Bldg. #6 APPENDIX Values Used in the Calculation of the Interior Noise Levels (Ocean Pointe Bldg. #6 - Along SCRAA Mainline - With Upgrades) Final Noise Analysis Ocean Pointe Bldg. #6 CASE 1: Ran A1 Living Roan Exterior Walls: BUILDING ELEMENT Roof Wall Windcw(sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft*2) 10LogS/A Total Noise Reduction AREA (ft2) 269.6 333.8 64 667.4 -1 28.6 EWNR 37 40 22 24 25 26 Interior Level 42.9 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" Single Gazed 1/8" Single Gazed (5/32", 5/16" air, 5/32") 1 .75' Solid Core - Weather Stripped Reduction Required: ,|Q(-EWNIV10) 0.053792 0.033380 0.202386 0.289558 26.5 CASE 2: Ran A1 Dining Room Exterior Walls: BUILDING ELEMENT •Roof Wall Window(sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft*2) 10LogS/A Total Noise Reduction AREA (ft2) 148 90 238 -2 33.9 EWNR 37 40 22 24 23 26 Interior Level 37.6 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" Single Gazed 1/8" Single Gazed 3/16" Single Gazed 1 .75" Solid Core - Weather Stripped Reduction Required : 1Q(-EWNIV10) 0.029530 0.009000 0.038530 26.5 CASE3: RanA1 Master Bedroom Exterior Walls: BUILDING ELEMENT Roof Wall Window(siicling) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (W2) 10LogS/A Total Noise Reduction AREA (ft2) 246.9 172.7 64 483.6 0 28.6 EWNR 37 40 22 24 28 26 Interior Level 42.9 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" Single Gazed 1/8" Single Gazed (1/8", .046 Laminate, 1/8") 1 .75" Solid Cere - Weather Stripped Reduction Required : ..g(-EWNR/10) 0.0492630 0.0172700 0.1014332 0.1679662 26.5 Final Noise Analysis Ocean Pointe Bldg. #6 CASE4: PlanAI Kitchen Exterior Walls: BUILDING ELErvENT Roof Wall Window (si iding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft*2) 10LogS/A Total Noise Reduction AREA (ft2) 124.6 202.5 18 345.1 1 28.8 EWNR 37 40 26 24 23 26 Interior Level 42.7 dB CCMVENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (1/8", 1/2' air, 1/8") 1/8" Single Gazed 3/16" Single Gazed 1.75" Solid Core- Weather Stripped Reduction Required: 10(-EWNR/10) 0.024861 0.020250 0.045214 0.090325 26.5 CASES: PlanAI Bedroom2 Exterior Walls: BUILDING ELErVENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft"2) 10LogS/A Total Noise Reduction AREA(f?) 188.1 319.2 48 555.3 0 28.7 EWNR 37 40 26 24 23 26 Interior Level 42.8 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (1/8", 1/2" air, 1/8") 1/8" Single Glazed 3/16" Single Glazed 1.75" Solid Core - Weather Stripped Reduction Required : 10(-EWNR/10) 0.037531 0.031920 0.120571 0.190021 26.5 CASE6: PlanA2 LivingRoom Exterior Walls: BUILDING ELEMENT Roof Wall Window (si iding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft*2) 10LogS/A Total Noise Reduction AREA (ft2) 270.2 333.8 64 668 -1 28.6 EWNR 37 40 22 24 25 26 Interior Level 42.9 dB CCMVENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. 1/8" Sngle Gazed 1/8" Sngle Gazed (5/32", 5/16" air, 5/32') 1 .75" Solid Core - Weather Stripped Reduction Required : 10(^MVt6) 0.053912 0.033380 0.202386 0.289678 26.5 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 7: RanA2 Dining Room Exterior Walls: BUILDING EUEMENT Ftoof Wall Window(slidng) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (1^2) 10LogS/A Total Noise Reduction AREA (ft2) 147 90 237 -2 33.9 EWNR 37 40 22 24 23 23 Interior Level 37.6 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" Single Gazed 1/8" Single Gazed 3/16" Single Gazed 1 .75" Solid Core - Weather Stripped Reduction Required : .|Q(-aMwio) 0.029330 0.009000 0.038330 25.5 CASE 8: Ran A2 Master Bedroom Exterior Walls: BUILDING ELEMENT Roof Wall Window(sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (W2) 10LogS/A Total Noise Reduction AREA (ft2) 242.5 171.8 64 478.3 0 28.6 EWNR 37 40 22 24 28 25 Interior Level 42.9 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" Single Gazed 1/8" Single Gazed (1/8", .045 Laminate, 1/8") 1.75" Solid Core - Weather Stripped Reduction Required : ^(-EWNR/10) 0.048385 0.017180 0.101433 0.166998 26.5 CASE 9: RanAZ Bedroom 2 Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window(fixed) Door (sliding) Door (entry) TOTAL AREA (W2) 10LogS/A Total Noise Reduction AREA (ft2) 187 318.3 48 553.3 0 28.6 EWNR 37 40 26 24 23 26 Interior Level 42.9 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int (1/8" -1/2' Air- 1/8") 1/8" Single Gazed 3/16" Single Gazed 1 .75" Solid Core - Weather Stripped Reduction Required : 10(WMO) 0.037311 0.031830 0.120571 0.189712 26.5 10 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 10: PlanAZ Kitchen Exterior Walls: BUILDING ELEMENT Roof Wall Window(sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft*2) 10LcgSA Total Noise Reduction AREA (ft2) 123.9 204.3 18 346.2 1 28.8 EWNR 37 40 26 24 23 26 Interior Level 42.7 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (1/8" -1/2" Air -1/8") 1/8" Single Glazed 3/16" angle Glazed 1 .75" Solid Cere - Weather Stripped Reduction Required : ,|Q(-EWNR/10) 0.024721 0.020430 0.045214 0.090365 26.5 CASE 11: Ran Bl Master Bedroom Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft^) 10LogS/A Total Noise Reduction AREA (ft2) 194.5 264.9 36 18 24 537.4 0 28.5 EWNR 37 40 30 28 23 26 Interior Level 43.0 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. 1/4" laminated (1/4" lam., 3/8" air, 1/8") 3/16" Single Glazed 1 .75" Solid Core - Weather Stripped Reduction Required : .i/\(-EWNR/10) 0.038808 0.026490 0.036000 0.028528 0.060285 0.190111 26.5 CASE 12: flanBI Living Room Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (fr2) 10LogS/A Total Noise Reduction AREA (ft2) 272.3 242 64 578.3 -1 28.8 EWNR 37 40 22 24 26 26 Interior Level 42.7 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" angle Glazed 1/8" Single Glazed (5/32', 5/16" air, 5/32") 1 .75" Solid Core - Weather Stripped Reduction Required : 1Q(-BMW16) 0.054331 0.024200 0.160761 0239292 26.5 11 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 13: Plan 81 Bedroom 2 Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) 10LogS/A Total Noise Reduction AREA (ft2) 149.3 206.1 30 24 409.4 0 28.5 EWNR 37 40 28 27 23 26 Interior Level 43.0 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (1/8", 1/2" air, 1/8") (3/16", 7/16" air, 1/8") 3/16" Single Glazed 1.75' Solid Core- Weather Stripped Reduction Required : 10l-tWMVlO) 0.029789 0.020610 0.047547 0.047886 0.145832 26.5 CASE 14: PlanBI Den Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) 10LogS/A Total Noise Reduction AREA (ft2) 128 69 30 227 -4 28.9 EWNR 37 40 23 24 23 26 Interior Level 42.6 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. 1/8" Single Glazed 1/8" Single Glazed 3/16" Sirgle Glazed 1.75' Sdid Cere- Weather Stripped Reduction Required : 10(-EWNR/10) 0.025539 0.006900 0.150356 0.182796 26.5 CASE 15: PlanBl Kitchen & Nook Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) 10LogS/A Total Noise Reduction AREA (ft2) 166.2 220.5 54 440.7 1 28.5 EWNR 37 40 29 24 23 26 Interior Level 43.0 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (1/4" laminated) 1/8" Single Glazed 3/16" Single Glazed 1 .75" Sdid Core - Weather Stripped Reduction Required : 10(-£WR/10) 0.033161 0.022050 0.067982 0.123193 26.5 12 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 16: RanBZ Master Bedroom Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft"2) 10LogS/A Total Noise Reduction AREA (ft2) 194.3 280.2 36 24 534.5 0 28.6 EWNR 37 40 28 24 23 26 Interior Level 42.9 cB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (3/16", 7/16" air, 1/8') 1/8" Single Glazed 3/16" Single Glazed 1.75" Solid Core- Weather Stripped Reduction Required : 1Q{-EWIR/10) 0.038768 0.028020 0.057056 0.060285 0.184129 26.5 CASE 17: RanB2 Living Room Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTALAR£A(ff2) 10LcgS/A Total Noise Reduction AREA (ft2) 268.5 240.2 64 5727 -1 28.8 EWNR 37 40 22 24 26 26 Interior Level 42.7 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. 1/8" Single Glazed 1/8" Single Gazed (5/32", 5/16" air, 5/32") 1.75" Solid Core- Weather Stripped Reduction Required : ^(-EWIR/10) 0.053573 0.024020 0.160761 0.238354 26.5 CASE 18: PlanB2 Bedroom2 Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft^) 10LcgS/A Tote! Noise Reduction AREA (ft2) 139.3 229.2 30 398.5 0 29.0 EWNR 37 40 26 24 23 26 Interior Level 42.5 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int (1/8", 1/2' air, 1/8") 1/8" Single Glazed 3/16" Single Glazed 1.75" Solid Core - Weather Stripped Reduction Required : 1Q(-EWNR/10) 0.027794 0.022920 0.075357 0.126071 26.5 13 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 19: PlanBZ Den Exterior Wdls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA(ft*2) 10LogS/A Total Noise Reduction AREA (ft2) 122.4 66.3 30 218.7 -4 28.8 EWNR 37 40 23 24 23 26 Interior Level 42.7 dB COMMENTS Built-Mp Roofing 7/8' Stucco, 5/8" Gyp. lit 1/8" Single Gazed 1/8" Single Gazed 3/16" Single Gazed 1.75' Solid Core - Weather Stripped Reduction Required : .|Q(-£WNfyiO) 0.024422 0.006630 0.150356 0.181408 26.5 CASE20: RanBZ Wtahen&Nook Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft"2) 10LogS/A Total Noise Reduction AREA (ft2) 168.3 216.9 54 439.2 1 28.5 EWNR 37 40 29 24 23 26 Interior Level 43.0 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int (1/4" laminated) 1/8" Sngle Gazed 3/16" Single Gazed 1.75" Solid Core- Weather Stripped Reduction Required : 10(-EVW10) 0.033580 0.021690 0.067982 0.123252 26.5 CASE21: PlanCl Living Room Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA(ft"2) 10LogS/A Total Noise Reduction AREA (ft2) 250.3 150 84 48 24 556.3 -1 28.7 EWNR 37 40 22 32 29 26 Interior Level 42.8 cB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" G/p. Int 1/8" Single Gazed (1/4" laminated) (1/8", 1/4" air, 1/4" lam.) 1.75" Solid Core- Weather Stripped Reduction Required : .|Q(-EVWIO) 0.049941 0.015000 0.053000 0.060428 0.060285 0.238656 26.5 14 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 22: PlanCI Dining Ftocm Exterior Walls: BUILDING ELEMENT Roof Wdl Window (hiding) Window (fixed) Dcor(slio5ng) Door (entry) TOTAL AREA (ft*2) 10LogS/A Total Noise Reduction AREA (ft2) 198 182.7 18 398.7 1 28.9 EWNR 37 40 26 24 23 26 Interior Level 42.6 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int (1/8", 1/2" air, 1/8") 1/8" Single Glazed 3/16" Single Gazed 1 .75" Solid Core - Weather Stripped Reduction Required : 10(-E»NR/10) 0.039506 0.018270 0.045214 0.102990 26.5 CASE 23: PlanCI Kitchen Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) 10LogS/A Total Noise Reduction AREA (ft2) 115.9 242.1 358 1 31.8 EWNR 37 40 22 24 23 26 Interior Level 39.7 cB COIWENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" Single Gazed 1/8" Single Gazed 3/16" Single Gazed 1 . 75" Solid Core - Weather Stripped Reduction Required : ^(-EWNR/10) 0.023125 0.024210 0.047335 26.5 CASE 24: PlanCI Master Bedroom Exterior Walls: BUILDING ELEMENT Roof Weil Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTALAFEA(ft'2) 10LogS/A Total Noise Reduction AREA (ft2) 302.2 251 18 64 635.2 0 28.6 EWNR 37 40 22 24 30 26 Interior Level 42.9 cB COMMENTS BuK-Up Roofing 7/8" Stucco, 5/8" Gyp. Int 1/8" Single Gazed 1/8" Single Gazed (3/16", 1/4" air, 3/16") 1 .75" Sdid Core - Weather Stripped Reduction Required : ^Q(-EWNR/IO) 0.060297 0.025100 0.071659 0.064000 0221056 26.5 15 Final Noise Analysis Ocean Pointe Bldg. #6 CASE25: PlanCl Bedrcom2 Exterior Walls: BUILDING ELEMENT Roof Wall Wndow(sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft"2) 10LogS/A Total Noise Reduction AREAfft2) 154.5 54.8 64 273.3 -3 29.2 EWNR 37 40 22 24 27 26 Interior Level 42.3 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. 1/8" Single Gazed 1/8" Single Gazed (5/32", 5/16" air, 5/32") 1.75" Sd id Core- Weather Stripped Reduction Required: 10(-B/**V16> 0.030827 0.005480 0.127697 0.164004 26.5 CASE26: PlanC2 LivingRoom Exterior Walls: BUILDING ELEMENT Roof Wall Window(sliding) Window (fixed) Door (sliding) Door(entr^ TOTAL AREA (ft"2) 10LogS/A Total Noise Reduction AREA (ft2) 208.6 192.6 72 48 24 545.2 -1 28.6 EWNR 37 40 22 31 29 26 Interior Level 42.9 dB COMMENTS Built-Up Roofing 7/8"Stuooo,5/8"Gyp.lnt. 1/8" Single Gazed (1/4" laminated) (1/8", 1/4" air, 1/4" lam) 1.73' Solid Core-Weather Stripped Reduction Required: 10(-£WMV10) 0.041621 0.019260 0.057192 0.060428 0.060285 0.238786 26.5 CASE27: RanD1 Den Exterior Walls: BUILDING ELEMENT Roof Wall Winabw(s!iding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft"2) 10LogS/A Total Noise Reduction AREA(ft2) 111.1 224.7 48 383.8 -1 28.7 EWNR 37 40 22 24 26 26 Interior Level 42.8 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. 1/8" Sirgle Gazed 1/8" Single Gazed (5/32', 5/16" air, 5/32') 1.75" Solid Core- Weather Stripped Reduction Required : 10C-EWIV10) 0.022167 0.022470 0.120571 0.165208 26.5 16 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 31: Ran D1 Kitchen & Nook Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) lOLogS/A Total Noise Reduction AREA(ttz) 184.9 219 24 427.9 1 28.6 EWNR 37 40 26 24 23 26 Interior Level 42.9 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int (1/8" OS, 7/16" air, 1/8" OS) 1/8" Single Glazed 3/16" Sngle Glazed 1.751 Solid Core-Weather Stripped Reduction Required : .|Q(-EWNR/IO) 0.036892 0.021900 0.060285 0.119078 26.5 CASE 32: Plan D2 Master Bedroom #1 Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) 10LogS/A Total Noise Reduction AREA (ft2) 218.3 258.9 30 507.2 0 28.9 EWNR 37 40 25 24 23 26 Interior Level 42.6 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int (1/8", 1/2" air, 1/8") 1/8" Single Glazed 3/16" Single Gazed 1 .75" Solid Core - Weather Stripped Reduction Required : 1f/SM«/1« 0.043557 0.025890 0.094368 0.164315 26.5 CASE33: PlanD2 Bedrcom2 Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) 10LogS/A Total Noise Reduction AREA (ft2) 196.9 151.5 60 408.4 0 29.0 EWNR 37 40 29 24 23 26 Interior Level 42.5 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (3/16", 7/16" air, 1/8") 1/8" angle Glazed 3/16" Single Glazed 1 .75" Solid Core - Weather Stripped Reduction Required : 10(-EWNR/10) 0.039287 0.015150 0.075536 0.129972 26.5 18 Final Noise Analysis Ocean Pointe Bldg. #6 CASE 37: PlanEZ Bedroom 2 Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ftA2) 10LogS/A Total Noise Reduction AREA (ft2) 169 104.1 57 330.1 0 28.5 EWNR 37 40 29 24 23 26 Interior Level 43.0 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (3/15" -7//16" Air- 1/8") 1/8" Single Glazed 3/16" Single Glazed 1 .75" Solid Core - Weather Stripped Reduction Required : IQ(-EWNR/IO) 0.033720 0.010410 0.071759 0.115889 26.5 CASE 38: Plan E2 Kitchen & Nook Exterior Walls: BUILDING ELEMENT Roof Wall Window (sliding) Window (fixed) Door (sliding) Door (entry) TOTAL AREA (ft*2) 10LogS/A Total Noise Reduction AREA (ft2) 193.5 236.7 54 36 520.2 1 28.7 EWNR 37 40 31 30 23 26 Interior Level 42.8 dB COMMENTS Built-Up Roofing 7/8" Stucco, 5/8" Gyp. Int. (1/4" lam., 3/8" air, 1/8") (1/4" lam., 3/8" air, 1/8") 3/16" Single Glazed 1 .75" Solid Core - Weather Stripped Reduction Required : 10(-B/W16> 0.038608 0.023670 0.042894 0.036000 0.141172 26.5 20