Loading...
HomeMy WebLinkAbout; 1280 Hoover Street; Rough Grading Certification; 2003-01-294656 Briar Ridge Rd. Oceanside Ca. 92056 Office 497-5039 Fax 941-5627 Integrily Construction January 29,2003 Re: Tract/Parcel Map No. 1280 Hoover Street Attn Mr. David Dates; We request the release of building pad lot no. APN206-150-2100 also known as 1280 Hoover St. Carlsbad Calif. Enclosed are certificates for pad elevation and soil reports as per your request. Respectfully, Steve Spi'^ General Contractor mpany built ipon afirmfinaidation Armstrong & Brooks Consulting Engineers Planning-lnfrastmcture-Slte Development-Water Resources Rough Grading Certification Date: January 13,2003 City of Carlsbad Public Works Department Inspection Division, Attn: Mr. David Dates 1635 FaradayAvenue (760) 438-4178 (fax) TRACT/PARCEL MAP NO. 1280 Hoover Street LOT NOS. COVERED BY THIS CERTIFICATION DWG. NO. 405-5A APN 206-150-2100 As engineer of record for the subject project, I hereby certify that the rough grading has been completed m accordance with the approved plans on file with the City. As engineer of record, I further certify that: (1) all grades and pad elevations are in conformance with the approved plans. The pad has been field verified within one-tenth of a inch; (2) all property line locations are in confonnance with the approved plans; (3) all pads'drain toward an approved drainage system or towards the street at a minimum of 1%- (4) I have venfied hne and grade for all drainage stmctures; (5) all slopes, including cut ^d fill slopes have been constmcted in the location(s) and at the slope(s) as shown on the approved plans. I also certify that all erosion control devices shown on the approved erosion control plans (if applicable) have been installed and that all Best Management Practices (if applicable) as defined in the project Stoma Water Pollution Prevention Plan (SWPPP) have been implemented. REMARKS: Pad Certification onlv per field survey performed 12/05/20Q2 CIVIL ENGINEER: William D. Brooks. P.E. 53114 DATE: 1 -13-2003 C: Dr. Shantu Patel via fax. (760) 967-3828 Integrity Constmction (Steve) (760) 941-5627 Armstrong & Brooks Consulting Engineers 1530 Consumer Cir., UnitB- Corona, CA - 92880 Ph. (909) 372-8400 ~ Fax (909) 372-8430 Testing Engineers- San Diego, Inc. Established 1946 Dr. Shantu Patel 2851 Columbia Drive Oceanside, CA 92056 December 2, 2002 Project No. 2000-080D Subject: Project: Reference: Dear Dr. Patel; AS-GRADED GEOTECHNICAL TESTING AND OBSERVATIONS REPORT Patel Residence 1280 Hoover Street Carlsbad, Califomia "Limited Geotechnical Investigation, Proposed Single Family Residence, 1280 Hoover Street, Carlsbad, Califomia", prepared by Testing Engineers San Diego, Inc., project number 2000-080, dated March 10, 2000. In accordance with your request, Testing Engineers - San Diego, Inc. (TESD) has conducted grading observation and compaction testing during preparation of the above referenced project. Services described herein were provided by TESD from November 7, 2002 through November 20, 2002. As indicated in our field reports, a representative of this office observed placement of fill within the pad area. Building pad subgrade preparation included overexcavation to a minimum depth of 4 feet below pad grade and a lateral distance of 6 feet outside of the perimeter of the planned stmcture. The driveway area was overexcavated in accordance with our referenced geotechnical report. The bottom of the overexcavations were scarified, moisture conditioned and recompacted prior to the placement of fill. The approximate test locations are presented on the Plot Plan in Appendix A. Summaries of field and laboratory compaction test results are provided on Tables 1 and 2 in Appendix B. Results of our field observations and density testing indicate that the fill placed within the pad meets the relative connaction requirements of 90 percent or greater based on test method ASTM D-1557. It is our opinion tiiat the residential pad preparation including tiie placement of fill was conducted in substantial conformance with tiie referenced geotechnical report and local grading ordinances. If you should have any questions after reviewing this report, please do not hesitate to contact the undersigned at (858) 715-5800. Sincerely, Testily Engineers - San Diego, Inc. Eitiiifk J. Aldrich, GE 2565 Geotechmcal Engineer 2000-080D Patel Residence As-Graded Testing Engineers - San Diego, Inc.. 7895 Convoy Court, Suite 18 San Diego, CA. 92111 [858] 715-58 00 Fax [858] 715-5810 APPENDIXA PLOT PLAN APPENDIXB COMPACTION TEST RESULTS Table 1 REPORT OF COMPACTION TEST DATA Print Date: November 22,2002 Project Number: 2000-080D Project Name: Patel Residence Location: 1280 Hoover Street Cailsbad, CA Engineer; Erick J. Aldrich, GE 2565 Renewal 6/30/06 Test# Test Oate Test Locafion Moisture Dry Density (pcf) Relative Compaction Conform Test Oate Field Optimum Field Maximum Obtained Required Non-Conform 1 11/7/2002 House Pad, W Keyway ^ §119.5 ft Elev. 10.5% 9.5% 126.2 132.0 96% 90% Conform 2 11/7/2002 House Pad, W Keyway ^ §121.5 ft Elev. 11.1% 9.5% 126.1 132.0 96% 90% Conform 3 11/7/2002 House Pad, W Keyway S 122.5 ft Elev. 10.9% 9.5% 127.0 132.0 96% 90% Conform 4 11/12/2002 Circular Driveway Turn Around @ 122 0 ft Elev. 11.7% 8.0% 132.1 134.0 99% 90% Conform 5 6 11/12/2002 11/13/2002 House Pad, W Fill Slope, 124.5 ft Elev. 50 ft N, 25 ft E of NW Corner of Retaining Wall on Parcel #1, 126.8 ft Elev. 11.1% 8.4% 8.0% 8.0% 135.6 126.5 134.0 134.0 101% 94% 90% 90% Conform Conform 7 11/13/2002 125 ft N. 35 ft E of NW Corner of Retaining Wall on Parcel #1, 126.8 ft Elev. 8.6% 8.0% 128.2 134.0 96% 90% Conform 8 11/13/2002 9 11/13/2002 10 11/13/2002 11 11/15/2002 35 ft N of NW Comer of Retaining Wall on 7.8% 8 0% 121 1 134 0 Parcel #1,127.5 ft Elev. 140 ft N, 40 ft E of NW Corner of Retaining 8.7% 8.0% 1216 134 0 Wall on Parcel #1, 127.5 ft Elev. 130 ft N of NW Corner of Retaining Wall 7.4% 8.0% 123 6 134 0 on Parcel #1,120.5 ft Elev. 35 ft E, 25 ft Nof SW Corner of Retaining 8.7% 8.0% 125 6 1340 Wall, Parcel #1,127.5 ft Elev. 90% 90% Conform 91% 90% Conform 92% 90% Conform 94% 90% Conform 12 11/15/2002 90 ft E, 105 ft N of SW Corner of Retaining Wail on Parcel #1,127.5 ft Elev. 9.0% 8.0% 122.2 134.0 91% 90% Conform 13 11/15/2002 82 ft E, 48 ft N of SW Corner of Retaining Wall on Parcel #1, 127.5 ft Elev. 12.7% 8.0% 118.1 134.0 88% 90% Nonconforr 13A 14 11/15/2002 11/15/2002 Retest of #13, Dated 11/15/2002 148 ft N, 38 ft E of SW Corner of Retaining Wall on W Slope Keyway, 120.3 ft Elev. 8.1% 9.6% 8.0% 8.0% 124.0 123.8 134.0 134.0 93% 92% 90% 90% Conform Conform 15 11/15/2002 140 ft N, 28 ft E of SW Corner of Retaining Wall on W Slope Keyway, 122.5 ft Elev. 7.9% 8.0% 122.5 134.0 91% 90% Conform 16 11/18/2002 Garage Sut)grade, Elev. 127.8 ft, Finish Grade 8.8% 8.0% 122.2 134.0 91% 90% Conform 17 11/18/2002 Garage Subgrade, Elev. 127.8 ft.. Finish Grade 6.9% 8.0% 125.1 134.0 93% 90% Conform 18 11/18/2002 Driveway Subgrade, Elev. 126.0 ft, Finish Grade 9.1% 8.0% 127.9 134.0 95% 90% Conform 19 11/18/2002 Driveway Subgrade, Elev. 126.0 ft. Finish Grade 6.9% 8.0% 125.1 134.0 93% 90% Conform 20 11/20/2002 House Pad, Finish Grade, Elev. 129.5 ft 6.9% 8.0% 127.1 134.0 95% 90% Conform 21 11/20/2002 House Pad, Finish Grade, Elev. 129.5 ft 7.3% 8.0% 128.9 134.0 96% 90% Conform Page 1 of 2 REPORT OF COMPACTION TEST DATA Print Date: Project Number Project Name: Locat'on; Engineer: Test# Test Date November 22,2002 2000-080D Patel Residence 1280 Hoover Street Carisbad, OA Erick J. Aldrich, GE 2565 Renewal 6/30/06 Test Location Moisture Field Optimum Dry Densi^ (pcf) Field Maximum Relative Compaction Obtained 22 11/20/2002 House Pad, Finish Grade, Elev. 129.5 ft 7^2% ao% m9 mo 95% 23 11/20/2002 House Pad, Finish Grade, Elev. 129.5 ft 6.7% 8.0% 128.3 134.0 96% Required Conform Non-Conform 90% 90% Conform Conform Page 2 of2 TABLE 2 RESULTS OF MAXIMUM DENSITY TESTS (ASTM-D-1557) SAMPLE # DESCRIPTION MAXEMUM DRY DENSITY (PCF) OPTEVim MOISTURE CONTENT (%) 1 Dark orange-brown silty sand 2 Orange-brown silty sand 134.0 132.0 8.0 9.5