HomeMy WebLinkAbout; Carlsbad Sewage Plant Bridge Pier; Soils Report; 1971-06-15FOUNDATION SOILS INVESTIGATION Sewer Line Bridge Pier Carlsbad Sewage Plant Carlsbad, California - - - Client: Salkin Engineering Corporation June 15, 1971 Job No. 71-404-l 0 KG KENNETH G. OSBORNE &ASSOCIATES TABLE OF CONTENTS Page - .-~ .- - .- - - - - INTRODUCT*ON-- __________________________________ FIELD INVESTIGATION----------------------------- LABORATORY TESTING------------------------------ CONCLUSIONS AND RECOMMENDATIONS Sit- Conditions---------------------------- Subsurface Conditions---------------------- Soil Bearing and Depth of Piling----------- General------------------------------------ APPENDIX Boring Log--------------------------------- Boring Location---------------------------- 0 KG KENNETH G. OSBORNE &ASSOCIATES - Job No. 71-404-l Page 1 - - INTRODUCTION This report presents the results of a Foundation Soils Investigation performed at the Carlsbad Sewage Plant, Carlsbad, California. Planned for construction is a bridge pier for the crossing of a drainage channel with a sewer line. The pier is to be supported on driven wood pilings. FIELD INVESTIGATION' The field investigation consisted of excavating an exploratory boring to a depth of 20 feet. The boring was drilled using an 18 inch bucket auger drilling rig. The majority of the required test information was obtained in the field by means of a standard penetrometer. The penetro- meter used was the, standard split-barrel sampler. It was driven with blows from a 140 pound hammer falling 30 inches. The number of hammer blows required to drive the-sampler 12 inches is recorded on the boring log as the penetration resistance of the soil. In addition, bulk samples of the soils were obtained for laboratory analysis. These soil samples, together with the standard penetration results served as the basis for the laboratory testing and the engineering conclusions contained in this report. The log of the boring and a plot plan showing approximate boring location are included with this report. LABORATORY TESTING The laboratory testing consisted of performing the material classification and determining the in situ moisture content of major soils. 0 KG KENNETH G.OSBORNE &ASSOCIATES Job No. 71-404-l Page 2 - - - - - - CONCLUSIONS AND RECOMMENDATIONS Site Conditions The location of the bridge support is to be in the center of the Flood Control Channel. The area is almost constantly under water due to the downstream restriction of a culvert. This pond also contains a substantial amount of organic sewage. Due to the amount of water and the muddy condition of the site, the boring was placed.as near the proposed pier as possible and is considered sufficient to provide the necessary information. Subsurface Conditions The subsurface soils consist mainly of silty sands with a 2 foot layer of clay at a depth of 5 feet. The soils are generally wet and the ground water table was encountered at a depth of 10 feet. Much caving was observed below this depth. The penetrations indicate that the soils exist in a loose to moderately firm condition. Soil Bearing and Depth of Piling The proposed structure is to be supported on driven wood piles. The bearing capacity will depend almost entirely on skin friction between the wood pile and the native soil. The loading of the individual piles has been supplied by Salkin Engineering Corporation and is equal to 7500 pounds per pile. It is expected that piles of at least one foot in diameter will be used. For this size pile, calculations indicate that the pile shall be driven to a depth of at least 20 feet into natural ground. 0 KG KENNETH G. OSBORNE &ASSOCIATES ,- - - .- - - Job No. 71-404-l Page 3 If a different size pile is used, the following formula for depth of piling applies: (400 w d = 7) where "d" is the pile depth in feet and "D" is the average pile diameter in feet. The above depth and formula are based on the assumption that the penetration resistance encountered during the driving of the piles will correspond with those values encountered in the preliminary boring. This penetration resistance shall be checked at the time the piles are driven. If penetration resistance differs substantially, the depth of piling will have to be re-evaluated by use of the Engineering News formula. General The recommendations contained in this report are based on the results of field investigation, laboratory testing and represent our best engineering judgment. If soil conditions encountered during the placement of piles differ substantially from those described in this report, this office should be notified immediately so that appropriate recommendations can be made. 0B:dhd Respectfully submitted, KENNETH G. OSBORNE & ASSOCIATES L!!ziLgv F*z Osb jorn Bratene Project Engineer Kenneth G. Osborne R.C.E. 14340 0 KG KENNETH G.OSBORNE&ASSOClATES - .- - APPENDIX - - 0 KG KENNETH G. OSBORNE &ASSOCIATES - SURFACE ELEVATION .- - .- - - - .-- - ~- - - - ~- ORGANIC SEWAGE lenses clayey streaks CAVING from 10' KENNETH C. OSBORNE & ASSOC:I.\TES BORING LOG TEST HOLE NO. 1 Page A .- - - - - - - - - -, ,- .- -. - KENNETH G. OSBORNE & ASSOCIhTr”sS . JO.3 NO. 1 DATE 7/-.&i-46 -M-7/ A,,,,&f~4~z~:~ fi :%c AC.C. /43/u ,. rage 13