HomeMy WebLinkAbout; La Costa Greens; Soils Report Final; 1970-05-28L 5673 - - - - - PHlLlP HENKING BENTON PIFSIDLNT ClYlL CNOINIC” Ranch0 Lo Costa, inc. Rwh 1, Box 2550 Encinitas, California 92024 BENTON ENGINEERING, INC. APPLIED SOlL MECHANICS ~.,- FOUNDITlONS 6741 EL CAJON mOULE”*RD *AN DIE00. CALIFORNIA 921,s May 28, 1970 6AU DIEGO: ,I)J-S6S4 LA MIS*: .6*-s=*. Subject: Project No. 69-lo-24D Fimi Report on Ccmpachd Filled Ground and Recommendations for Sicpa Stability and Soil Bearing Values La Costa Green North of La Costa Avenue East of El Camino Real San Diogo County, California Permit No. L5673 Gentlemen: This is to report the rosuits of tests and obrrvatiotn mode in order to inspect the compaction of fiiiod grwnd placed on certain aroas of Lots 1 to 10, inciusive, La Costa Greens, being a Subdivision of a Portion of kctiom 35 and 36, Township 12 South, Rarge 4 West, S.B.B.b M. San Diego County, California. These fills wire placed during the period between October 24, 1969 and May 15, 1970. Reference is made to wr report of Proiect No. 69-6-12C, doted January 20, 1970, in which M stated that stability of thr slopes wwid be confirmed and rrcommendations for dosign of safe and economical fwndatiom would be made after the grading was completed. These items will be discussed further on Pqe 2 of this report. The approximate areas and depths of filled ground placed under wr impaction in accordance with the approved specifications ore shown on Drawig No. 1, entitled “Location of Compacted Filled Grwnd. ” The gradinp plon used for the placement of filled ground was prepared by Rick Eginoerirq Company and dated January 26, 1970. Pioase note that a portion of the filled ground was placed over compressibio ground. This orea is roforred to on Drowirg No. 1 as, “fill placed over ccmpressibie ground.” It is recommended that spciai design precwtions be exercised in this area to minimize possible damqe to the sttucture CII a result of sottlemont. The approximate locations at which the tests were taken and the final test results are p-ant& on ~910 Tl to T4, inclusive, under the “Table of Test Results.” The laboratory determimtiwr of the maximum dry dersttios and optimum moisture contents of ho maior fill matariais are pmsrnkd on pqe T5, under the “Laboratcry Test Rosuik.” Some of he maximum dry demities shown in the ktbir of test results wre combimtiom of thesr. The tests wire taken during the mekiy periods indicated on the foilowirg pqe. - SlOlO .17.73 c.2 Project No. 69-IO-24D La Costa Greens -2- Test Number Week Ending 1 October 24, 1969 2 October 31, 1969 3afd4 November 14, 1969 5 to 33, inclusive November 2 1, 1969 34 to 86, inclusive December 19, 1969 87 to 101, lnciusiv. December 26, 1969 102 to 119, inclusive May 8, 1970 120 to 141, inclusive May 15, 1970 - The final results of tests and observations indicate that the filled ground, placed under wr ilrpection, has been canpacted to 90 percent of maximum dry deraity or greater. - Direct shear tests vmr. performed on selected loose soil sonpies remolded to 90 percent of maxlmum dry denri ty that mre ail saturated and drained prior to testig . The results of these tests are presented below: - Sample 1 Normal Load in kiprhq ft 0.5 1.0 2.0 Maximum Agi. of Shear internal Load Friction kips/sq ft Degrees 1.10 1.21 29.3 1.94 ib/sq ft 650 Sample 2 0.5 0.85 1.0 1.17 16.0 700 2.0 1.46 Sample 3 0.5 0.65 1.0 ,0.72 9.2 575 2.0 0.88 - Appiyirg the Terzaghi Formula to the results of the above tests indicates that the fiti materiais ccmpacted to 90 percent of maximum dry density have a safe bearirg value of 1300 pounds per - square foot for on. foot wide contirvous footings founded at a minimum depth of two feet below the iomrt adjacent grwnd level, and placed five feet or more inside the top of compacted filled ground slopes. If footings are placed closer to the exposed slopes than five feet imide - the top of compacted filled ground slopes, these shwld be deepened on. foot below a om and om half horizontal to on. vertical line prolected outward and downward from a point five feet horlzontaiiy irmide the top of the compacted filled ground slopes. Tests indicate that the can- - pacted tl lied ground is adquate to satisfactoriiy support on. or two story wood frame dweiiirgs desigmd for the recommended bearing value without detrimental settlements in the areas where the compacted filled ground is placed wer stable natural ground. No accurate prediction can - - BENTON ENGINEERING. INC. Project No. 69-IO-24D La Cceta Greenr -3- May 28, 1970 be made concernirgl the settlement for structures placed on the compacted filled ground overlying the “compressible ground” areas shown on Drawig No. l!, However, it is understood that the foundation design used for the Stables and the Maintemnco Building, which were both placed over similar compressible soiis, has been performing satisfactoriiy. it is recommended that the sane design criteria be used for structures in these area. Through tests and observations it has been determimd that expansive soils exist in the upper three feet below finished grade on ail of the lots covered by this report. it is therefore recom- mended that the following special design precaution be taken for the hwses to be constructed on these lots. - 1. isolated interior piers shwid not be used. Continuous footigs should be used throughout, and these should be placed at a minimum depth of two feet below the iov+ast adjacent exterior final ground surface. - .- .- - - 2. 3. 4. Reinfcrce and interconnect continuously with steel bars ail interior and exterior footirgs with om #5 bar at 3 inches above the bottom of ail footings and one ‘5 bar placed 1 l/2 inches below the top of the stems of the footirgs. Use raised wood floors that span betwon continuwr fwtigs, or reinforce ail concrete slabs with 6 x 6 - IO/IO woven wire fabric and provide a minimum of 4 inches of clean sand beneath ail concrete slobs. provide a moisture barrier 2 inches below slabs under livirg areas. Separate garage slabs from perimeter fwtigs by l/2 inch thickness of construc- tion felt or equivalent, to allow independent movement of garqe slabs relative to perimeter footirgs. 5. Provide positive dmirqe away from ail perimeter footings to a horizontal distance of at least 6 feet wtside the hwse wails. it is concluded from the test data that the flii soil4 when uniformly compacted to at least 90 percent of maximum dry demity in accordance with the approved specifications, will be stable for heights up to 28 feet when constructed on a 1 l/1 horizontal to 1 vertical, or flatter slopes. A stability analysis for the proposed fill slope is presented on Drawirg No. 2, Hhichdemon- strates a safety factor of 1.5 arsumitg a horizontal seismic force of 0.1 g . The above conclusion assume that erosional control and proper drainage to prevent surface water from running aver the top of exposed slopes will be provided. Pqes Tl to T5, inclusive, and Drawirg Nos. 1 and 2, are a part of this report. - Respectfully submitted, - BENTON ENGINEERING, INC. - B Reviemd William C. Catiin, Civil Engineer - Distr: (3) Addressee (2) Mr. B. L. homer BENTON ENGINEERING. INC IR\ Pi-L S..s.l..ur:.m Cr...mm.... Proiect No. 69-IO-24D La Costa Greera Test No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 : 38 Approx- D.Ph imate of Flli Location at Test Lot No. in Feet 1 2 7 3 : 7 9 3 2 1 6 8 10 5 7 5 4 10 9 6 9 3 5 2 1 4 3 8 7 4 5 6 7 5 3 1 6 4 7 3 13.3 105.5 115.8 91.2 2 13.2 108.0 119.9 90.1 * 12.3 119.8 124.2 96.4 1 13.2 109.6 121.0 90.6 2 11.9 115.1 122.1 94.3 4 11.0 114.3 122.1 93.7 2 13.5 112.9 122.0 92.6 2 10.4 113.1 122.1 92.6 4 10.1 1FO.O 122.1 90.1 6 14.6 111.1 120.5 92.2 7 11.2 115.2 122.1 94.4 4 9.8 111.8 122.1 91.6 4 10.4 114.2 122.1 93.5 2 12.2 113.9 120.5 94.5 6 11.3 108.2 121.6 89.1 6 12.6 109.6 119.9 91.5 6 12.3 109.3 120.5 90.8 8 13.3 111.8 121.0 92.4 6 13.1 112.9 121.0 93.4 6 13.7 113.1 120.5 93.9 8 11.9 108.7 119.9 90.7 8 13.0 111.0 121.0 91.8 8 12.1 111.1 120.0 92.6 10 14.4 111.2 116.4 95.6 10 14.4 114.1 120.0 95.2 11 15.2 112.2 120.0 93.6 12 14.7 112.2 120.0 93.6 12 14.8 110.4 120.0 92.0 8 12.8 114.4 122.1 93.7 10 10.4 115.6 124.2 93.1 16 13.9 117.3 122.1 96.1 14 13.7 111.9 123.2 90.8 12 12.2 110.8 121.0 91.6 14 10.3 114.1 122.1 93.4 18 10.6 114.2 122.1 93.5 16 12.7 109.6 118.1 92.7 15 7.6 116.4 124.2 93.7 16 10.9 106.7 118.1 90.3 20 16.1 106.2 112.3 94.6 18 12.7 107.8 113.9 94.6 Tl TABLE OF TEST RESULTS Field Moisture %drywt Dry Denity ib/cu ft Maximum w Density Ib/cu ft Percent Compaction Pamark Reworked Check on 115 l Backfill ofremoved area. BENTON ENGINEERING. INC - - - - - - - - -. - - - .- - Proiect No. 69-IO-24D T2 La &to Greens Test No. 41 42 43 44 2 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 2 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 Approx- D.Ph imate of Fill Location at Test Lot No. in Feet Field DV Moisture Denily %drywt Ib/cu ft Maximum b Demity Ib/cu ft Percent Compaction Rem& 2 14 13.3 108.8 118.0 92.2 1 17 13.6 107.7 113.9 94.6 2 16 13.5 109.9 118.0 93.1 3 18 13.3 109.8 118.0 93.0 2 18 9.5 118.5 124.2 95.4 3 20 12.2 115.1 122.1 94.3 2 20 9.4 116.2 124.2 93.6 3 22 12.2 112.8 122.1 92.3 1 19 8.6 115.1 124.2 92.6 3 24 10.7 114.0 124.2 91.8 2 22 14.2 107.2 112.3 95.5 2 24 13.3 105.8 112.3 94.2 3 26 12.1 108.2 113.9 95.1 9 10 11.1 106.8 118.0 90.6 8 10 11.9 110.5 118.0 93.7 10 8 10.0 112.5 122.1 92.2 3 27 11.9 109.8 118.0 93.1 4 22 13.7 110.8 118.0 94.0 1 22 12.2 113.0 117.4 96.3 2 25 14.9 108.7 113.9 95.5 1 23 21.1 101.8 110.6 92.1 1 25 14.5 110.3 118.0 93.6 2 26 14.9 105.3 113.9 92.6 1 27 15.2 106.4 113.9 93.5 2 28 16.5 105.4 112.3 93.8 2 30 15.5 106.8 113.9 93.8 3 28 15.6 109.8 118.0 93.1 2 32 11.8 111.8 122.1 91.6 1 29 14.2 108.9 118.0 92.3 2 34 12.2 103.0 113.9 90.5 1 31 11.6 112.0 122.1 91.8 2 38 12.8 109.7 118.1 92.9 4 24 14.7 101.2 112.0 90.3 4 26 14.7 106.8 112.3 95.0 4 28 14.8 106.9 113.9 93.8 5 20 12.9 107.9 118.0 91.4 4 30 11.1 110.0 122.1 90.1 7 10 13.6 108.0 118.0 91.6 8 6 15.4 104.5 112.3 93.0 8 8 15.3 112.2 118.0 95.1 TABLE OFTEST RESULTS (CONI) BENTON ENOINEERING. INC F'roiect No. 69-IO-24D T3 La haGreens TABLE OF TESTRESULTS(CONT.) Test No. 81 82 83 84 85 86 EJ 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 IW 108 103 110 111 112 113 114 115 116 117 118 119 120 Approx- hPh imate of Fill Location at Test Lot No. inFeet 8 10 3 9 10 9 10 9 10 9 10 9 8 10 8 9 10 8 10 1: 10 10 10 l&2 10 162 3&4 566 10 10 1 10 6 7 10 10 10 10 9 a 10 10 12.6 106.7 118.0 90.5 8 12.0 109.1 119.0 91.7 20 11.3 111.5 122.1 91.4 8 14.8 105.2 112.7 93.5 10 16.9 104.4 112.7 92.7 10 15.1 116.7 122.1 95.5 12 14.3 104.9 112.7 93.2 12 14.5 108.4 118.0 91.9 14 17.2 108.4 118.0 91.9 14 11.1 106.8 118.0 90.6 18 10.2 109.3 118.0 92.7 18 13.0 lop.1 118.0 92.6 12 13.4 107.3 118.0 91.1 20 14.1 108.2 118.0 91.9 16 12.3 106.6 112.2 94.9 22 14.5 109.3 118.0 92.7 22 15.0 104.8 112.2 93.4 20 12.6 107.7 113.9 94.6 26 14.2 107.2 113.9 94.1 24 11.2 110.5 118.0 93.6 30 11.7 111.3 122.1 91.3 7 18.2 105.9 112.7 94.0 9 15.8 114.1 120.0 95.1 11 15.7 112.3 120.0 93.7 2 17.3 107.1 116.4 92.1 13 16.4 103.2 116.4 93.9 6 20.4 102.2 110.6 92.6 4 17.2 103.8 114.0 91.2 4 19.2 104.2 113.0 92.4 15 23.4 100.1 110.6 90.6 17 22.8 97.6 lW,l 91.1 31 19.9 100.1 110.6 90.6 19 24.3 100.1 110.6 90.6 20 15.0 106.8 117.0 91.3 20 22.4 97.3 1W.l 90.8 21 20.7 102.9 112.0 92.0 23 21.7 101.4 110.6 91.8 25 21.8 102.9 110.6 93.1 27 21.4 101.6 110.6 92.0 4 15.3 108.2 ,117.o 92.5 Fleid Moisture %drywt Dry Denity Ib/cu ft Maximum Dr-Y Density ib/cu ft Percent Compaction Remsks BENTON ENGINEER,NG. iNC. Proiect No. 69-IO-24D La Cwta Greens T4 Test No. 121 122 123 124 125 126 127 - 128 129 130 - 131 132 133 - !E 136 - 137 138 139 - 140 141 - Apprm- D.Pth imate of Fill Location at Test Lot No. in Feet 10 6 1 7 8 9 d 10 7&8 2 3 182 384 586 788 9 a 10 4 5 6 7 8 9 10 29 10 33 11 14 : 39 30 lo? 8' 8* 8+ 12 * 32 22 22 22 25 25 31 TABLE OFTESTRESULTS(CONT.) Field bY Moisture D.r.ity % dry wt Ib/cu ft Mauimum BY Demity ib/cu ft Percent Compaction ibmarks 22.0 100.6 110.6 91.0 19.6 101.6 112.0 90.7 21.5 101.8 110.6 92.1 14.4 107.2 113.3 94.6 20.0 103.7 113.3 91.5 14.4 111.2 121.0 92.0 12.6 110.6 121.0 91.5 11.9 112.4 122.1 92.2 16.8 113.0 121.0 93.4 15.2 112.3 121.0 93.0 15.9 108.2 116.4 93.0 17.8 104.0 113.3 91.8 13.9 109.2 118.0 92.7 15.1 109.9 118.0 93.2 14.6 113.2 120.0 94.5 15.9 111.8 116.4 96.1 14.1 114.6 122.1 93.8 15.4 112.1 120.0 93.5 13.9 112.8 121.0 93.3 16.3 108.5 116.4 93.2 12.8 114.t 122.1 93.5 l Finished Grade - - - BENTON ENGINEERING. INC. project No. 69-IO-24D La Costa Greens T5 LABORATORY TEST RESULTS The maximum dry densities and optimum moisture contents of the maior fill moteriais o deter- mined by the A.S.T.M. D 1557-66T method, that uses 25 blom of a 10 pound hammer faiiirg from a height of 18 inches on each of 5 layers in a 4 inch diameter l/30 cubic foot compaction cylinder, are presented as follows: Soil Type - Gray very fine to fim sandy clay Dark gray very fin. sandy clay Light greenish-gray clayey very flm to fim - sand with ciayston. chunks Light greenish-gmy slightly clayey fine sand Oiive-green silty clay - Gray brown slightly silty fine sand Brown fin. sandy clay Dark gray silty clay Yellow-brown silty fim sand Gray-black silty clay Light brown silty fim sand Maximum Optimum Mois- Dry Dermlty ture Content ib/cu ft % dry wt 115.8 9.8 119.9 12.2 124.2 11.2 122.1 11.5 110.6 15.7 113.9 13.3 117.4 13.1 110.5 16.3 116.0 13.2 118.0 13.6 103.6 15.5 - - - - - BENTON ENGINEERING. INC. I - - ,- - - - - - - - - 5Ge i 67 i ’ c 2,9 ‘&,r ,z /- 2 I7 GiccC~;c i ;1 \ J 6 *.- _ ,~, , - / A -i ,,..“,a- , ,,? ,,, : ti: \ . . $- I. ;+-. 0 ‘; c LC - ./ i ,,& ,. ,‘A- ” ; ,‘? , rz.5 - I--3. cc3 % *r’ 2: L1 + :- I’ , ..” .’ ;.--,y ~, -/ __.~-~-,~- -5, 0.~; “i’ ~+. .;” .,1. -3 3 ,’ ,j /,$ ; >/53~JC SLOPE STABILITY ANALYSIS LA COSTA GREENS :SAN DIEGO COUNTY, CALIFORNIA PROJECT NO. 69- lo-24D i BENTON ENGINEERING, INC. DRAWING NO. 2 .- -~ - PHILIP HENI(IHG BENTON PIIEIIIDENT CIYIL ENGIWIZI” BENTON ENGINEERING, INC. APPLIED *OIL MECHANICS - FOUNDATION6 6741 EL CAJON BOULEYARD *AN DIEGO. CALIFORNIA 02115 June 25, 1970 SAN DIL.z.2: ,w-se*. L* ML**: 46WS8S4 Ranch0 La Costa, Inc. Routs 1, Box 2550 Encinitco, California 92824 Subiect: Project No. 69 -lO-24D Report of Results of pH and Soil Resistivity Tests La Costa Greens North of La Costa Avenue East of El Camino Real San Diego County, California Permit No. L5673 Gentlemen: This is to repcrt the results of a soil reslstlvlty test and a pH test of the most active soils likely to come in contact with the culvert pipe on subject project. These tests were performed in accordonce with Test Method No. Califomla 643-B, Part III and Port IV of the California Division of Highways Materials Marual. The pH of the soil was determined to be 5.3 and the minimum resistivity WOI 375 ohms. Accord- ing to the Chart for Estimating Yean to Perforation of Metal Culverts, these data indicate a useful life of approximately three years for 16 gcuge corrugated metal pipe. In order to meet the 25 year life required by the County of San Diego, It is recommended that the minimum wail thickness of corrugated metal pipe imtolled on subject proiect be 12 gauge and that this pipe be treated with an asbestos bonded bituminous coatlrrg and paved invert o indicated In Table 7-821.6A of Part 7 of the California Division of Hlghvmys Plannirg Manual, This treatment will add 20 yean to the life of the pipes carrylrg abrasive materials at flow velocities not exceedlrg 7 feet per second and for culvert pipes carryirg non-abralve materials at flow velocities greater than 7 feet per second. This treatment coupled with the odded life anticipated from 12 gauge pipe rather than 16 gwge pipe will meet the minimum required life expectancy of 25 years. Respectfully submitted, BENTON ENGINEERING, INC. - . ..Q&cL Willlam G. Catlin, Civil Eglneer Distr: (3) Addressee (2) Mr. B. L. Kmmer (3) Rick Ergimerlrg Company ( 1) Robert W. Radgen