Loading...
HomeMy WebLinkAbout3190; RANCHO SANTA FE ROAD; COMPRESSION TESTING OF DRILLED CONCRETE CORES; 2003-07-01Jul 10 03 12:09p Son. & TESTING. INC Hanson User (858)577-2789 P.2 Mt) I P c N E I P.O. Box 600627 (619)280-4321 I San Diego, CA 92160-0627 TOLL FREE I (877) 2154321 6280 Riverdale Street I FAX SanDiego, CA92120 (619) 280-4717 I www.scst.com July 1, 2003 S SCS&T No. 0312002 Report No. 8 Mr. Wes Jacobs Hanson Aggregates Post Office Box 639069 San Diego, California 92163-9069 Subject: COMPRESSION TESTING OF DRILLED CONCRETE CORES RANCHO SANTA FE ROAD CLEANOUT BOX CARLSBAD, CALIFORNIA Dear Mr. Jacobs: In accordance with your request, Southern California Soil and Testing, Inc., (SCS&T) has drilled and tested three 4-inch diameter concrete cores from a cleanout box. The location of the cores was determined by Jeff Hicks with Solid Structures SCS&T $ technician drilled thcores on 22003 and the three cores were tested on June 26, 2003. The procedures of Uniform Building Code (UBC) Section 1905.6.4.3 and ASTM C42-99, "Obtaining and Testing Drilled Cores and Sawed Beams of Concrete", were followed in the drilling. In accordance with ASTM C42-99 paragraph 7.3.1, the cores were tested in a "dry condition" after air-drying them for 14 days at a temperature of 16 to 270c and 60% relative humidity. The compressive strengths of each core have been corrected for a height to diameter ratio less than 1.94 but greater than 1.00. Test results are provided in the attached Table A. We appreciate the opportunity to provide our materials engineering services. Should you have any questions or if we f further service, please contact our office at you convenience. Respectfully Su SOUTHERN Gordon T. W Attachment: TTable~."I'60r " TC' GTW:vah (1) Addressee TESTING, INC. Jul 10 03 12:09p Hanson User (858)577-2789 P.3 Hanson Aggregates - July 1, 2003 Rancho Santa Fe Road, Cleanout Box SCS&T No. 0312002-08 - . Page 2 TABLE A COMPRESSIVE STRENGTH OF DRILLED CONCRETE CORES RANCHO SANTA FE RAOD, CLEANOUT BOX Core No I Core No. 2 Core No. 3 Date Cored 06/24/03 06/24/03 06/24/03 Date Tested 06/26/03 06/26/036 06/26/03 Age, Days Tested Height (in) 6.88 6.23 - 6.69 Diameter (in) 3.75 3.75 3.75 Area (in 2.) 11.04 11.04 11.04 UD Ratio 1.83 1.66 1.78 Correction Factor 0.9884 0.9728 0.9832 Total Load (Ibs) 37,000 37,500 36,500 Uncorrected Compressive Strength (psi)' 3,350 3,400 3,310' Compressive Strength (psi) 3,310 3,31O' Z. 3,250 Average 28-day Compressive Strength (psi) /,'13,290 1 ) Sic ST . ' '