Loading...
HomeMy WebLinkAbout3626; ACCESS EASEMENT RECONSTRUCTION PLANS; CONCRETE TEST REPORT; 1999-11-22LAW/CRANDALL ow L. . 9177 Sky Park Ct. San Diego, CA 92123 (619) CONCRETE TEST REPORT --1 DEC 1 0 I; 0-SAD CLIENT: City of Carlsbad PROJECT: City of Carlsbad, Gibraltar Street Gibraltar Street, Carlsbad MIX ID: 103201 - DATE: 11/22/99 JOBNO: 41.50396.31 LAB NO: 33027 SPECIFIED STRENGTH: 3 , 250 PSI MIX DESC: Concrete FIELD INFORMATION DATE SAMPLED: 10/25/99 BY: S. Skelton SLUMP, INCHES: TIME BATCHED: SAMPLED: 11: 45 AIR, PERCENT: BATCH PLANT: Palomar UNIT WEIGHT, PCF: TRUCK/TICKET: 833/96988 0 DATE RECEIVED: 10/26 /99 MIX/AIR TEMP, °F: COMPRESSION TEST RESULTS FIELD TESTS (ACTUAL) (SPECIFIED) 3 1/2 N. I. N. I. 80 CYLINDER NUMBER DIAMETER (IN.) AREA (SO. IN.) DATE TESTED TEST AGE (DAYS) MAX LOAD (LBS.) COMP. STRENGTH (PSI) FRACTURE TYPE 1 6.00 28.27 11/01/99 7 58,000 2,050<<< A 2 6.00 28.27 11/22/99 28 97,500 3,450 A 3 6.00 28.27 11/22/99 28 95,500 3,380 A 4 RESERVE UNLESS OTHERWISE INDICATED, TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING ASTM TEST METHODS: C39, C138, C143, C173, C1064 * DENOTES CURED IN FIELD <<< DENOTES LOW COMPRESSIVE STRENGTH FRACTURE TYPE IS INDICATED BY LETTER: (A) CONE (B) CONE & SPLIT (C) CONE & SHEAR (D)SHEAR (B) COLUMNAR POUR LOCATION: 24' access basement; Sta 25 + 75 REMARKS: Sampled at 32 cubic yards of 56 NOTE: Reserve cylinder discarded DISTRIBUTION: City of Carlsbad (1C,1B,1D,1ALL) SP SUBMITTED 1507 ison, RCE #54734