Loading...
HomeMy WebLinkAbout3674; Poinsettia Lane Reach 3 - Hunsaker; Poinsettia Lane Reach 3; 1999-06-091 i to p "OIK P 0 ii Ai' : GEOTECHNICAL INVESTIGATION POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA PREPARED FOR HUNSAKER AND ASSOCIATES SAN DIEGO, CALIFORNIA JUNE 1999 GEOCON INCORPORATED GEOTECHNICAL CONSULTANTS Project No. 06313-12-01 June 9, 1999 Hunsaker and Associates 10179 Huennekens Street San Diego, California 92121 Attention: Mr. Ray Martin Subject: Gentlemen: POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA GEOTECHNICAL INVESTIGATION In accordance with our Proposal No. LG-99155 and your authorization, we have performed a geotechnical investigation of the proposed Poinsettia Lane ("Reach 3") alignment in Carlsbad, California. The proposed Poinsettia Lane ("Reach 3") alignment will extend from its intersection with Black Rail Road easterly to the existing Poinsettia alignment at approximate Station 162+90 for a distance of approximately 1350 feet. The accompanying report presents the results of our study and conclusions and recommendations pertaining to the geotechnical aspects of developing the property as presently proposed. Provided the recommendations of this report are followed, the site is considered suitable for roadway development as currently planned. If you should have any questions regarding this report, or if we may be of further service, please contact the undersigned at your convenience. Very truly yours, GEOCON INCQ RCE 22527 PD:AS:DFL:dmc (6) Addressee CERTIFIED ENGINEERING GEOLOGIST Paul Dunster RG6761 6960 Flanders Drive 558-6900 TABLE OF CONTENTS 1. PURPOSE AND SCOPE 1 2. SITE AND PROJECT DESCRIPTIONS 1 3. SOIL AND GEOLOGIC CONDITIONS 2 3.1 Compacted Fill (Qcf) . 2 3.2 Undocumented Fill (Qudf) 2 3.3 Topsoil/Colluvium (unmapped) 3 3.4 Alluvium (Qal) 3 3.5 Lindavista Formation (Qln) 3 3.6 Santiago Formation (Ts) 4 4. GROUNDWATER 4 5. GEOLOGIC HAZARDS 4 5.1 Faulting and Seismicity 4 5.2 Liquefaction 5 5.3 Landslides 6 6 . CONCLUSIONS AND RECOMMENDATIONS 7 6.1 General 7 6.2 Soil and Excavation Characteristics 7 6.3 Grading 8 6.4 Subdrains 9 6.5 Fill Slopes 10 6.6 Slope Stability 10 6.7 Preliminary Pavement Section 10 6.8 Slope Maintenance 11 6.9 Drainage 11 6.10 Grading Plan Review 12 LIMITATIONS AND UNIFORMITY OF CONDITIONS MAPS AND ILLUSTRATIONS Figure 1, Vicinity Map Figure 2, Geologic Map Figure 3, Cross Section A-A' Figure 4, Fill Slope Stability Analysis Figure 5, Surficial Slope Stability Analysis Figure 6, Typical Subdrain Detail Figure 7, Recommended Subdrain Cut-Off Wall Figure 8, Subdrain Outlet Headwall Detail APPENDIX A FIELD INVESTIGATION Figures A-l-A-19, Logs of Trenches TABLE OF CONTENTS (Continued) APPENDIX B LABORATORY TESTING Table B-I, Summary of Laboratory Maximum Dry Density and Optimum Moisture Content Test Results Table B-II, Summary of Laboratory Direct Shear Test Results Table B-III, Summary of Laboratory Expansion Index Test Results APPENDIX C RECOMMENDED GRADING SPECIFICATIONS GEOTECHNICAL INVESTIGATION 1. PURPOSE AND SCOPE This report presents the results of a geotechnical investigation for Poinsettia Lane ("Reach 3"). The subject site is located south of Palomar Airport Road, between Poinsettia Lane's intersection with Black Rail Road, and the existing Poinsettia lane alignment at approximate Station 162+90, in Carlsbad, San Diego County, California (Figure 1). The purpose of this report was to evaluate surface and subsurface soil and geologic conditions and, based on those conditions, provide recommendations pertaining to the geotechnical aspects of improving the roadway as proposed. The scope of this geotechnical investigation consisted of performing a geologic reconnaissance and the excavation of 19 backhoe trenches and geologic mapping. The approximate locations of the exploratory excavations are depicted on Figure 2. Logs of the exploratory trenches are presented in Appendix A. Our scope also included a review of: 1. Report of Preliminary Geotechnical Investigation [for] DeJong Property (APN 215-080-01), Carlsbad, California, prepared by Geotechnical Exploration Incorporated, dated January 12, 1998, 2. Final Report of Testing and Observation Services During Site Grading [for] Black Rail Road (Approximate Station 15+10 to Sapphire Drive) Off-site Cobblestone Sea Village Units 1 and 2, Carlsbad, California, prepared by Geocon Incorporated, dated April 6, 1999, 3. California DMG Open-File Report 96-02 entitled Geologic Maps of the Northwestern Part of San Diego County, California, and 4. An improvement map entitled Grading and Improvement Plans for Poinsettia Lane, prepared by Hunsaker & Associates, undated. Laboratory tests were performed on selected soil samples to evaluate pertinent physical properties. Details of the field investigation and laboratory tests are presented in Appendices A and B. The recommendations presented herein are based upon an analysis of the data obtained in the referenced reports, observations during this investigation and our experience with similar soil and geologic conditions. 2. SITE AND PROJECT DESCRIPTIONS The Poinsettia Lane ("Reach 3") alignment which is located in Carlsbad, California consists of approximately 1,350 feet of future road alignment. The proposed road alignment is bounded on the Project No. 06313-12-01 -1- June 10, 1999 east and west sides by existing reaches of Poinsettia Lane, and to the north and south the property is surrounded by rural/natural and agriculturally-developed properties. Topographically, the property consists of a slope descending from an elevation of approximately 370 feet Mean Sea Level (MSL) in the west to a steeply-incised brush-filled gully in the east at an elevation of approximately 260 feet MSL. The site drains primarily to the north and east. Site vegetation generally consists of native weeds, grasses, scattered trees and bushes. Some of the property has been cultivated in the past, and there are partially ruined buildings and trailers in the western and eastern portions of the site. Fences, firewood piles, debris, dirt roads, end dumped soil, overhead powerlines, and a reclaimed water pipeline were observed on the property. 3. SOIL AND GEOLOGIC CONDITIONS Five surficial soil types and two geologic formations underlying the proposed roadway alignment were encountered during this field investigation. The surficial units include topsoil, undocumented fill and debris, previously placed compacted fill, alluvium, and colluvium. The Formational units encountered includes the Pleistocene-aged terrace deposit known as the Lindavista Formation underlain by the Eocene-aged Santiago Formation. The soil types and geologic formation are discussed below in order of increasing age. 3.1 Compacted Fill (Qcf) Compacted fill was encountered at the western end of the proposed alignment. As documented in the referenced grading report, this fill was placed under the observation of Geocon Incorporated during the period of March 11 through July 30, 1998, as part of the testing and observation services provided during the site grading for a portion of Black Rail Road (Reference No. 2). During the development of "Reach 3", this existing fill should be "benched", prior to placing additional compacted fill against it. The fill generally consisted of medium dense, damp, silty, fine to coarse sand. In exploratory Trenches T-12 and T-13, medium dense Terrace Deposits were encountered at 4'/2 and 3 feet below ground surface, respectively. 3.2 Undocumented Fill (Qudf) Undocumented fill and debris consisting of wood, plastic, household debris, and other refuse was observed over a large area in the vicinity of exploratory Trenches T-4, T-5, and T-18. Smaller areas covered with similar debris were noted in the vicinity of exploratory Trenches T-6, T-7, T-19 and T-16. End dumped soils were noted in the western portion of the project in the vicinity of Trench T-12. Other areas of undocumented fill may exist but were not observed. This is common where Project No. 06313-12-01 -2- June 10, 1999 agricultural activities may have masked the presence of such materials. It is recommended that all undocumented fill soils be removed and properly recompacted. Any debris or deleterious material should be removed and disposed of off-site. 3.3 Topsoil/Colluvium (unmapped) Topsoils and Colluvial materials on the order of 1 to 8 feet generally blanket the majority of the subject property. The soils generally consist of very loose to loose, porous, dry to saturated, silty, fine to coarse sand. Areas of deeper colluvium may occur within the proposed alignment. These soils in their present condition are compressible and are not considered suitable to receive improvements and will require remedial grading in the form of complete removal and recompaction. 3.4 Alluvium (Qal) Alluvial materials were encountered in exploratory Trenches T-3 and T-4 within the natural drainage valley that runs approximately north-south under the proposed eastern portion of the road alignment. Smaller amounts of alluvium were noted in exploratory Trench T-16. The alluvium generally consists of loose, damp to saturated, porous, silty to clayey sand. Observations of the alluvium within the trenches excavated during this field investigation indicate that the alluvium is up to 9 feet in thickness. Areas of deeper alluvium may occur within this valley. The alluvium in its present condition is compressible and is not considered suitable to receive improvements and will require remedial grading in the form of complete removal and recompaction. 3.5 Lindavista Formation (Qln) Pleistocene marine terrace deposits of the Lindavista Formation were encountered over the western portion of the site. This unit generally consisted of predominantly medium dense, light brown, moderate brown and greyish orange, silty, fine- to coarse-grained sandstone with varying amounts of fine-grained rounded gravel, and partially-cemented zones. It is anticipated that the majority of any excavation within this unit can be accomplished with conventional, moderate to heavy-duty grading equipment. Heavy ripping will be required for excavations in localized areas of highly cemented sandstone and/or conglomerate. Some oversized cemented chunks may be generated. Any oversized material (i.e., material greater than 12 inches in maximum dimension) will require special handling and placement as recommended hereinafter. In general, the Lindavista Formation possesses excellent foundation bearing characteristics in either a natural or properly compacted condition. The majority of these materials are anticipated to have a low to medium expansion potential. Project No. 06313-12-01 -3- June 10, 1999 3.6 Santiago Formation (Ts) The Eocene-aged Santiago Formation unconformably underlies the Lindavista Formation in the eastern portion of the project site. The Santiago Formation encountered generally consisted of dense, massive, very pale orange, greyish orange, pale and dark yellowish orange, slight to moderately weathered, clayey/silty, fine to coarse sandstone and well-graded sandstone. Some zones of hard, greenish gray to brown claystone and siltstone have been observed in other areas close to the site and should be expected. Flat-lying interbeds were observed in exploratory Trench T-3. It is anticipated that the majority of the excavation within this unit can be accomplished with conventional, moderate to heavy-duty grading equipment. The claystone and siltstone members of the Santiago Formation are stratigraphically equivalent to the Eocene-aged Friars Formation. Cut slope stabilization measures are frequently required for excavations within the clayey members due to the presence of inherently weak claystone beds, bedding plane shear surfaces, and groundwater seepage. Typically, the sandstone member of the Santiago Formation possesses excellent foundation bearing characteristics in either an undisturbed and/or properly compacted condition. The claystone and siltstone portions of the Santiago Formation, however, are generally weaker, and are moderately to highly expansive. In general, highly expansive soils should be placed in deeper fill areas and away from the face of the slope. 4. GROUNDWATER Groundwater was encountered in several of the exploratory trenches. Flowing water and seepage was typically noted within the surficial soils and at their contact with the underlying formational units. A subdrain should be installed following removal of alluvium from the steeply incised gully at the eastern end of the proposed alignment. Other smaller gullies and tributary canyons may be exposed during surficial soil removals. Additional subdrains should be installed to control any water that may enter these drainages prior to placing compacted fill. Grading should be periodically observed by an engineering geologist to evaluate the necessity for these additional subdrains. Specific subdrain recommendations will be presented in the Conclusions and Recommendations portion of this report. 5. GEOLOGIC HAZARDS 5.1 Faulting and Seismicity A review of geologic literature, experience with the soil and geologic conditions in the general area, and observations during the field investigation indicate that no active faults are located at the site. The nearest known active fault is the Rose Canyon Fault Zone located approximately 6 miles west of Project No. 06313-12-01 -4- June 10, 1999 the site. Maximum Credible and Maximum Probable seismic events of Magnitude 6.90 and Magnitude 5.70, respectively, are postulated for the Rose Canyon Fault Zone. The estimated Maximum Credible and Maximum Probable peak site accelerations are 0.31 g and 0.17 g, respectively. The maximum effective ground motion, however, is estimated to be approxi- mately 0.22 g for the same seismic event. The effective ground motion is associated with the significant part of the ground motion containing repetitive motions that possess strong energy content and that produce structural deformation. It has been estimated by Ploessel and Slosson (1974) that effective ground acceleration is equal to approximately 65 to 70 percent of the peak ground motion for earthquakes within 20 miles of a site. Seismic parameters for some other regional faults capable of generating ground acceleration at the site are summarized below. TABLE 5.1. DETERMINISTIC SITE PARAMETERS FOR SELECTED FAULTS Fault Name Rose Canyon Newport-Inglewood-Offshore Palos Verdes Coronado Banks Elsinore-Glen Ivy Elsinore-Temecula Elsinore-Julian Distance From Site (miles) 6 9 40 21 37 24 24 Maximum Credible Event Maximum Credible (Mag.) 6.90 6.90 7.10 7.40 6.80 6.80 7.10 Peak Site Acceleration (g) 0.31 0.24 0.07 0.16 0.06 0.10 0.12 Maximum Probable Event Maximum Probable (Mag.) 5.70 5.80 6.20 6.30 6.30 6.30 6.40 Peak Site Acceleration (g) 0.17 0.13 0.03 0.08 0.04 0.07 0.07 It is our opinion that the site could be subjected to moderate to severe ground shaking in the event of a major earthquake along any of the above mentioned faults, however, the seismic risk at the site is not considered to be significantly different than that of the surrounding developments of similar geologic settings in the Carlsbad area. 5.2 Liquefaction Liquefaction occurs in loose cohesionless soils located below the water table that are subjected to large accelerations during strong earthquakes. Due to the very dense nature of the formational units, the removal and recompaction of the surficial soils, the installation of subdrains, and the lack of a permanent groundwater table, the potential for liquefaction of the site subsoils is considered to be very low. Project No. 06313-12-01 June 10, 1999 5.3 Landslides Evidence of landslides on the subject property was not observed in our review of aerial photographs, geologic maps, or during on-site field investigations. Project No. 06313-12-01 - 6 - June 10, 1999 6. CONCLUSIONS AND RECOMMENDATIONS 6.1 General 6.1.1 No soil or geologic conditions were encountered during this geotechnical investigation performed by Geocon Incorporated that would preclude the development of the property provided that the recommendations of the report are followed. 6.1.2 The surficial soils such as the undocumented fill alluvium, colluvium and topsoil within \ areas of planned development are considered unacceptable to receive improvements in their present condition and will require remedial grading in the form of removal and recompaction. Also, the existing structures and trash will need to be removed and disposed / of off-site. 6.1.3 It is our understanding that the majority of the fill material will be imported from offsite. \ Geocon Incorporated should test imported soil for expansion potential and compaction j characteristics prior to it being imported to the site. Any large chunks of cemented sandstone imported to the site will require special handling and placement. / 6.2 Soil and Excavation Characteristics 6.2.1 The soil conditions encountered were low expansive sands derived from the Lindavista and Santiago Formations. However, some clayey materials should be anticipated from the imported soils, and on-site. These clayey materials are highly expansive and in general should not be placed as fill in the outer 3 feet of any fill slope face and/or within 10 feet of finish fill grade. Claystone material should be placed in the deeper portion of fill areas away from the slope zone. 6.2.2 It is anticipated that the surficial deposits can be excavated with a light effort using conventional heavy-duty grading equipment. A moderate to heavy effort is anticipated for excavations within the formational sedimentary units. Oversize materials in the form of cemented chunks and/or slabs of sandstone may be generated during excavation of portions of the Lindavista and Santiago Formations. Oversized rock or slabs should be broken so that no rock fragments greater than 4 feet in maximum dimension are placed in fills. Oversized rocks should be placed in accordance with the Recommended Grading Specifications in Appendix C. It is recommended that prior to beginning grading, acceptable areas and methods of rock disposal be designated and reserved for the placement of rock as it is encountered. Project No. 06313-12-01 -7- June 10, 1999 6.3 Grading 6.3.1 All grading should be performed in accordance with the Recommended Grading Specifications in Appendix C and the City of Carlsbad Grading Ordinance. Where the recommendations of this section conflict with those in Appendix C, the recommendations of this section take precedence. All earthwork should be observed and all fills tested for proper compaction by Geocon Incorporated. 6.3.2 Prior to commencing grading, a preconstruction conference should be held at the site with the owner or developer, grading contractor, civil engineer and geotechnical engineer in attendance. Special soil handling and/or the grading plans can be discussed at that time. 6.3.3 Site preparation should begin with the removal of existing structures, debris, vegetation, and all deleterious material. The depth of removal should be such that material exposed in cut areas or soils to be used as fill are relatively free of organic matter. Material generated during stripping and/or site demolition should be exported from the site. 6.3.4 All compressible surficial soil deposits (undocumented fill, topsoil, colluvium and alluvium) within areas of planned grading should be removed to firm natural ground and properly compacted prior to placing additional fill and/or structural loads. 6.3.5 The actual extent of unsuitable soil removals will be determined in the field during grading by the soil engineer and/or engineering geologist. Overly wet surficial soils will require drying and/or mixing with drier soils to facilitate proper compaction. 6.3.6 After removal of unsuitable materials as recommended above is performed, the site should then be brought to final subgrade elevations with structural fill placed and compacted in layers. Prior to placing fill, the exposed natural ground surface should be scarified to a depth of at least 12 inches, moisture conditioned and compacted. In general, soils native to the site are suitable for use as fill if free from vegetation, debris and other deleterious material. Layers of fill should be no thicker than will allow for adequate bonding and compaction. All fill, including scarified ground surfaces, should be compacted to at least 90 percent of laboratory maximum dry density in accordance with ASTM Test Procedure D-1557-91, at or slightly above optimum moisture content. Fills deeper than 50 feet should be compacted to at least 92 percent of the laboratory maximum dry density. Fill materials with in-place density test results indicating moisture contents less than optimum will require additional moisture conditioning before placing additional fill. Project No. 06313-12-01 -8- June 10, 1999 6.3.7 Oversize cemented sandstone chunks (defined as material greater than 12 inches in nominal dimension) will likely be generated during grading within the Formational units. Placement of oversize materials within fills should be performed in accordance with the recommendations in Appendix C. 6.3.8 Grading operations should be scheduled so as to permit the placement of oversized rock and expansive soils (if encountered) in the deeper fills. Oversized rock should be placed at least 5 feet below finish grade or 3 feet below the deepest utility, whichever is greater. 6.4 Subdrains 6.4.1 Subdrains (Figure 6) should be installed in the canyons to be filled. The subdrains should extend up the canyons to approximately 10 feet below ultimate finish grade elevations and/or at least 2 feet below any proposed utility. 6.4.2 The lower 20 feet of subdrains exiting the base of compacted fill slopes should consist of nonperforated pipe. A cutoff wall (Figure 7) should be constructed immediately below the junction of the perforated pipe with the non perforated pipe. The cutoff wall should extend at least 6 inches beyond the sides and bottom of the subdrain trench and 6 inches above the top of the pipe. 6.4.3 Where subdrain systems do not outlet into permanent structures such as storm drains, the outlet pipe should be provided with a concrete headwall (Figure 8), riprap, or similar device. 6.4.4 Anticipated locations of subdrains will be designated on the improvement plans during review by Geocon, Incorporated when plans are available. Actual locations may vary and final installation will be determined during grading. 6.4.5 After installation of the subdrains, the project Civil Engineer should survey the locations and prepare accurate As-built plans of the subdrain locations. The project soils engineer should verify the as-built subdrain outlet. The contractor should ensure that an adequate drainage gradient is maintained throughout the system, and that the subdrain outlet is free of obstructions. Project No. 06313-12-01 - 9 - June 10, 1999 6.5 Fill Slopes 6.5.1 The outer 15 feet of fill slopes, measured horizontal to the slope face, should be composed of properly compacted granular "soil" fill to reduce the potential for surface sloughing. 6.5.2 All fill slopes should be overbuilt at least 3 feet horizontally, and cut to the design finish grade. As an alternative, fill slopes may be compacted by back-rolling at vertical intervals not to exceed 4 feet and then track-walking with a D-8 dozer, or equivalent, upon completion such that the fill soils are uniformly compacted to at least 90 percent relative compaction to the face of the finished slope. 6.5.3 All slopes should be planted, drained and properly maintained to reduce erosion. 6.6 Slope Stability 6.6.1 Slope stability analysis utilizing average drained direct shear strength parameters based on laboratory tests and experience with similar soil types in nearby areas indicates that the proposed fill slopes, constructed of on-site materials, should have calculated factors of safety of at least 1.5 under static conditions for both deep-seated failure and shallow sloughing conditions. Slope stability calculations are presented on Figures 4 and 5. 6.7 Preliminary Pavement Section 6.7.1 Based on R-value tests performed on granular material derived from the Lindavista Formation from a nearby property, an assumed R-Value of 30 was used to evaluate preliminary pavement sections. A Traffic Index (TI) of 8.5 has been assumed for Poinsettia Lane. Utilizing the California Flexible Pavement Design procedure, and the City of Carlsbad minimum requirements, pavement sections were determined and are presented in Table 6.9. It should be noted that these pavement sections are preliminary. Grading operations should consider capping the roadway subgrade to a depth of 3 feet with granular imported soils. This should provide higher R value subgrade soils and result in decreasing the pavement section. The final pavement recommendations will be provided for City of Carlsbad approval after finish subgrade is achieved and R-Value tests are performed on the actual subgrade soils. Project No. 06313-12-01 -10- June 10, 1999 TABLE 6.7 PRELIMINARY PAVEMENT SECTIONS Location Poinsettia Lane Assumed Traffic Index 8.5 Asphalt Concrete (inches) 5 Class 2 Aggregate Base (inches) 12 6.7.2 Base course material should consist of aggregate base and be properly moisture conditioned and compacted to a minimum relative compaction (ASTM Dl557-91) of 95 percent at or above optimum moisture content. The upper 12 inches of subgrade soil should also be moisture-conditioned and compacted to a minimum relative compaction of 95 percent. 6.7.3 Aggregate base and asphalt concrete should conform to City of Carlsbad Standards. 6.8 Slope Maintenance 6.8.1 Slopes that are steeper than 3:1 (horizontal:vertical) may, under conditions which are both difficult to prevent and predict, be susceptible to near surface (surficial) slope instability. The instability is typically limited to the outer three feet of a portion of the slope and usually does not directly impact the improvements on the pad areas above or below the slope. The occurrence of surficial instability is more prevalent on fill slopes and is generally preceded by a period of heavy rainfall, excessive irrigation, or the migration of subsurface seepage. The disturbance and/or loosening of the surficial soils, as might result from root growth, soil expansion, or excavation for irrigation lines and slope planting, may also be a significant contributing factor to surficial instability. It is, therefore, recom- mended that, to the maximum extent practical: (a) disturbed/loosened surficial soils be either removed or properly recompacted, (b) irrigation systems be periodically inspected and maintained to eliminate leaks and excessive irrigation, and (c) surface drains on and adjacent to slopes be periodically maintained to preclude ponding or erosion. It should be noted that although the incorporation of the above recommendations should reduce the potential for surficial slope instability, it will not eliminate the possibility, and, therefore, it may be necessary to rebuild or repair a portion of the project's slopes in the future. 6.9 Drainage 6.9.1 Establishing proper drainage is imperative to reduce the potential for differential soil movement, erosion and subsurface seepage. Positive measures should be taken to properly Project No. 06313-12-01 June 10, 1999 finish grade the improvements so that drainage water is directed away from pavement and the tops of slopes into controlled drainage devices. Experience has shown that even with these provisions, a shallow groundwater or subsurface condition can and may develop in areas where no such condition existed prior to site development. This is particularly true where a substantial increase in surface water infiltration results from an increase in landscape irrigation. 6.10 Grading Plan Review 6.10.1 The geotechnical engineer and engineering geologist should review the grading plans prior to finalization to verify their compliance with the recommendations of this report and determine the necessity for additional comments, recommendations and/or analysis. Project No. 06313-12-01 -12- June 10, 1999 LIMITATIONS AND UNIFORMITY OF CONDITIONS 1. The recommendations of this report pertain only to the site investigated and are based upon the assumption that the soil conditions do not deviate from those disclosed in the investigation. If any variations or undesirable conditions are encountered during construction, or if the proposed construction will differ from that anticipated herein, Geocon Incorporated should be notified so that supplemental recommendations can be given. The evaluation or identification of the potential presence of hazardous or corrosive materials was not part of the scope of services provided by Geocon Incorporated. 2. This report is issued with the understanding that it is the responsibility of the owner, or of his representative, to ensure that the information and recommendations contained herein are brought to the attention of the architect and engineer for the project and incorporated into the plans, and the necessary steps are taken to see that the contractor and subcontractors carry out such recommendations in the field. 3. The findings of this report are valid as of the present date. However, changes in the conditions of a property can occur with the passage of time, whether they be due to natural processes or the works of man on this or adjacent properties. In addition, changes in applicable or appropriate standards may occur, whether they result from legislation or the broadening of knowledge. Accordingly, the findings of this report may be invalidated wholly or partially by changes outside our control. Therefore, this report is subject to review and should not be relied upon after a period of three years. Project No. 06313-12-01 June 10, 1999 4 VESPER Ul °:.«UEBH?. ?. '%5 PBLINA CT i: 'iV!£ 3:c/. SOURCE: 1999 THOMAS BROTHERS MAP SAN DIEGO COUNTY, CALIFORNIA REPRODUCED WITH PERMISSION GRANTED BY THOMAS BROTHERS MAPS. THIS MAP IS COPYRIGHTED BY THOMAS BROS. MAPS. IT IS UNLAWFUL TO COPY OR REPRODUCE ALL OR ANY PART THEREOF, WHETHER FOR PERSONAL USE OR RESALE. WITHOUT PERMISSION N NO SCALE GEOCON <gS> INCORPORATED ^SS^ GEOTECHNICAL CONSULTANTS 6960 FLANDERS DRIVE - SAN DIEGO, CALIFORNIA 92121-2974 PHONE 619 558-6900 - FAX 619 558-6159 PD/GBP DSK/DOOOD VICINITY MAP POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA DATE 06-10-1999 PROJECT NO. 06313-12-01 FIG. 1 ivici A 270 -i 280- 290- 300^ GEOCON LEGEND ALLUVIUM 7S SANTIAGO FORMATION , EXISTING GRADE T-4 E/RU/GEOTKH/6313PO.DWG/PACO PROPOSED GRADE CROSS SECTION A-A' SCALE 1" = 40' POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA A1 ,— 270 -280 -290 L300 GEOCON INCORPORATED GEOTECHNICAL CONSULTANTS 6960 FLANDERS DRIVE - SAN DIEGO, CALIFORNIA 92121 - 2974 PHONE 619 558-6900 - FAX 619 558-6159 PROJECT NO. 06313 -12 - 01 FIGURE 3 DATE 06-10-1999 PROJECT NO. 06313-12-01 ASSUMED CONDITIONS: Slope Height Slope Inclination Total Unit Weight of Soil Angle of Internal Friction Apparent Cohesion No Seepage Forces H = 50 feet 2:1 (Horizontal:Vertical) y, =125 pounds per cubic foot <|> = 28 degrees C =390 pounds per square foot ANALYSIS: Equation (3-3), Reference 1 Equation (3-2), Reference 1 Calculated Using Eq. (3-3) Determined Using Figure 10, Reference 2 Factor of Safety Calculated Using Eq. (3-2) FS = FS = REFERENCES: (1) Janbu, N., Stability Analysis of Slopes with Dimensionless Parameters, Harvard Soil Mechanics, Series No. 46, 1954. (2) Janbu, N., Discussion of J.M. Bell, Dimensionless Parameters for Homogeneous Earth Slopes, Journal of Soil Mechanics and Foundation Design, No. SM6, November 1967. FILL SLOPE STABILITY ANALYSIS POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA FIGURE 4 PROJECT NO. 06313-12-01 ASSUMED CONDITIONS: Slope Height H ' = Infinite Depth of Saturation Z = 3 feet Slope Inclination 2:1 (Horizontal:Vertical) Slope Angle i = 26.5 degrees Unit Weight of Water yw = 62.4 pounds per cubic foot Total Unit Weight of Soil yt = 125 pounds per cubic foot Angle of Internal Friction <(> = 28 degrees Apparent Cohesion C = 390 pounds per square foot Slope saturated to vertical depth Z below slope face. Seepage forces parallel to slope face ANALYSIS: = 3.1 REFERENCES: Yt Z sin i cos / (1) Haefeli, R. The Stability of Slopes Acted Upon by Parallel Seepage, Proc. Second International Conference, SMFE, Rotterdam, 1948, 1, 57-62. (2) Skempton, A. W., and F. A. Delory, Stability of Natural Slopes in London Clay, Proc. Fourth International Conference, SMFE, London, 1957, 2, 378-81. SURFICIAL SLOPE STABILITY ANALYSIS POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA FIGURE 5 APPROVED FILTER FABRIC 6" DIA. PERFORATED SUBDRAIN PIPE 1" MAX. OPEN-GRADED AGGREGATE 9 CUBIC FT./FT. MINIMUM NOTES: 1 SUBDRAIN PIPE SHOULD BE 6-INCH MINIMUM DIAMETER, PERFORATED, THICK WALLED SCHEDULE 40 PVC, SLOPED TO DRAIN AT 1 PERCENT MINIMUM AND CONNECTED TO STORM DRAIN SYSTEM OR APPROVED OUTLET. 2 WHERE DRAIN EXCEEDS 500 FEET, PIPE DIAMETER SHOULD BE INCREASED TO 8 INCHES 3 FILTER FABRIC TO BE MIRAFI 140N OR EQUIVALENT NO SCALE TYPICAL SUBDRAIN DETAIL GEOCON <^> INCORPORATED ^*SOr GEOTECHNICAL CONSULTANTS 6960 FLANDERS DRIVE - SAN DIEGO, CALIFORNIA 92121 • 2974 PHONE 619 558-6900 • FAX 619 558-6159 PD / GBP DSK/EOOOO POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA DATE 06-10-1999 PROJECT NO. 06313 - 12 - 01 FIG. 6 SD / IXVIII / RSS FRONT VIEW CONCRETE CUT-OFF WALL 6" MIN. (TYP) 6" MIN. (TYP) NO SCALE SIDE VIEW CONCRETE CUT-OFF WALL- SOLID SUBDRAIN PIPE 12" MIN. 6" MIN. (TYP). PERFORATED SUBDRAIN PIPE 6" MIN. (TYP) NO SCALE RECOMMENDED SUBDRAIN CUT-OFF WALL GEOCON ®> INCORPORATED ^SKF GEOTECHNICAL CONSULTANTS 6960 FLANDERS DRIVE - SAN DIEGO, CALIFORNIA 92121 - 2974 PHONE 619 558-6900 - FAX 619 558-6159 PD/GBP DSK/EOOOD POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA DATE 06-10-1999 PROJECT NO. 06313 - 12 - 01 JFIG. 7 RSCOW VI/IXVIIRSS FRONT VIEW 6" SUBDRAIN 18" 12" 24" NO SCALE SIDE VIEW NOTE : HEADWALL SHOULD OUTLET AT TOE OF FILL SLOPE OR INTO CONTROLLED SURFACE DRAINAGE NO SCALE SUBDRAIN OUTLET HEADWALL DETAIL GEOCON ®> INCORPORATED ^SiSr GEOTECHNICAL CONSULTANTS 6960 FLANDERS DRIVE - SAN DIEGO, CALIFORNIA 92121 -2974 PHONE 619 558-6900 - FAX 619 558-6159 PD / GBP | DSK/GTYPD POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA DATE 06-10-1999 PROJECT NO. 06313-12-01 FIG. 8 SOHD / VIII-IXVRSS I E i I I E I C C i"V C c C C E 1 E I APPENDIX A FIELD INVESTIGATION The field investigation was performed on May 13 and 17, 1999, and consisted of a visual site reconnaissance, and the excavation of 19 backhoe trenches. The approximate locations of the exploratory trenches are shown on Figure 2. The backhoe trenches were advanced to depths varying from 3 to 11 feet using a track-mounted backhoe equipped with a 24-inch-wide bucket. The soils encountered in the exploratory excavations were visually examined, classified, and logged. Logs of the backhoe trenches are presented on Figures A-l through A-19. The logs depict the soil and geologic conditions encountered. Project No. 06313-12-01 June 10, 1999 PROJECT NO. 06313-12-01 DEPTH IN FEET - 2 - - 4 - - SAMPLE NO. Tl-2 Tl-1 CDo4 H -1 ~ 1 1 -|.]-, 1 T 1•I'll '. •'.- •'.'• '• ~ - ''-.'• trLU <E C Oa:CD SOIL CLASS (USCS) SM SW TRENCH T 1 ELEV. (MSL.) 312 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose dry moderate yellowish brown Silty fine _ \ SAND / SANTIAGO FORMATION Medium dense, damp, grayish orange, well graded, fine to coarse SAND, slightly weathered, massive, scattered, randomly oriented joints up to 1/8" wide, black silt filled TRENCH TERMINATED AT 6 FEET oW~Hyi-(-JFU.<rS\ £"^ UJCOO Q. ^ _ > 1^^ . >w a ~ Ife ^^ J^£~* f~l CJ Figure A-l, Log of Trench T 1 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C ... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) £1 ... DISTURBED OR BAG SAMPLE B ... CHUNK SAMPLE I ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - - - 4 - - 6 - - fi _ 11) SAMPLE NO. T2-1 1 11I 3_LITHOLOG'•I-1-'--,. 1 - i-- 1 L .-!• •'-•i- 1 -l-j't.. -'i ":•!•••• 1 :[}•; " /- " .-•'.' •'.-:• ".-:•• a:HI GROUNDUA1SOIL CLASS (USCS) SM sw TRENCH T 2 ELEV. (MSL.) 300 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose, damp, dark yellowish brown, porous, Silty, fine to medium SAND, becomes moister with depth, prevalent sloughing of trench walls, common _^ -Slight seepage at contact(less than 1/2 gpm) ^_ SANTIAGO FORMATION Medium dense, damp, grayish orange, well graded, fine to medium SAND, slightly to moderately weathered, massive, scattered, randomly oriented joints up to 1/8" wide, black silt filled TRENCH TERMINATED AT 10 FEET Z <*N ENETRATIORESISTANCEBLOWS/FT.Q_fc*"^' _ - - - 5_ 1 a 96.6 ^MOISTUREONTENT (Xo 9.0 Figure A-2, Log of Trench T 2 PLR3 SAMPLE SYMBOLS D ... SAMPLING UNSUCCESSFUL ii ... DISTURBED OR BAG SAMPLE C . . . STANDARD PENETRATION TEST B . . . CHUNK SAMPLE ... DRIVE SAMPLE (UNDISTURBED) ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - _ -4-i - 6 - - 8 - - 10 - SAMPLE NO. T3-1 r 1 1T3-2 T3-3 i 1i ?T3-4 1 I CD ITHOLO_i '/: '/:/. v// /S'/7./:// "/// ty/- / S '^'/ fa % § £/X' .i/l 'y/I- i/l ')\4'JC.yTf/ y yXT i/l If -!/l '¥n a:UJi— c oCLCD SOIL CLASS (USCS) sc SC/SM TRENCH T 3 ELEV. (MSL.) 275 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION ALLUVIUM Loose, damp to moist, pale yellowish brown, Clayey, fine to medium SAND, porous, abundant rootlets (fine) -Slight seepage at contact SANTIAGO FORMATION Medium dense, damp, mottled, grays, dark yellowish orange, grayish orange, Silty, Clayey, fine to medium SAND, slightly weathered, weak, poorly defined undulatory, approximately flat ~\ bedding, scattered rootlets /~ TRENCH TERMINATED AT 1 1 FEET ZLU~ £ik iLlrnO Lu^mQ_a:w :_ - _ >• «C go •£^ Q 101.4 ~ || ^0o 7.5 Figure A-3, Log of Trench T 3 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) H ... DISTURBED OR BAG SAMPLE K ... CHUNK SAMPLE T. ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET . - 4 - - 6 - SAMPLE NO. 5T4-1 V >_ COa LITHOL"-1. ' •• -•''I •i T . V-'-•j. i - -1- •'- T '• V -< I rX - , HX 1 ' "x • . i • - < " I* ' " * 1 - L VI1 -- 1 1. •j-T a:LUi—<r GROUNDUSOIL CLASS (USCS) SM SM SM TRENCH T 4 ELEV. (MSL.) 310 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose, damp, dark yellowish brown, Silty, fine to medium SAND, abundant roots ALLUVIUM Loose, damp, moderate yellowish brown, fine to coarse Silty SAND, porous SANTIAGO FORMATION Medium dense, damp to wet, mottled dark yellowish orange, grays, Silty, fine to medium SAND, massive, moderately weathered TRENCH TERMINATED AT 7 FEET z ^o^ .HCJ,ENETRAT]JESISTANBLOUS/F1Q- ^ _ _ — >_ h~ H Q ^1 1 1 *^MOISTURONTENT <a Figure A-4, Log of Trench T 4 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL E... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) H ... DISTURBED OR BAG SAMPLE K ... CHUNK SAMPLE I ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - - 4 - - 6 - SAMPLE NO. T5-1 T5-2 T5-3 I 71|1 i CD LITHOLO".1 ''-•. "-,. \ -, -, I- iA \- - :j}- :]}• 4-1"T ^ ~-, i - i--•1-.|- -J- o:u.GROUNDWASOIL CLASS (USCS) SM SM TRENCH T 5 ELEV. (MSL.) 314 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOH7COLLUVIUM Loose to very loose, damp, moderate brown to dark yellowish brown, Silty, fine to medium SAND, porous -Slight seepage at contact SANTIAGO FORMATION Medium dense, damp, dark yellowish orange, Silty, fine to medium SAND, moderately weathered, massive TRENCH TERMINATED AT 8 FEET ZLJ'--ENETRATICJESISTANCBLOWS/FT.Q. ^ _ _ > |j Q ~MOISTUREONTENT Oo - Figure A-5, Log of Trench T 5 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C... STANDARD PENETRATION TEST 81 ... DISTURBED OR BAG SAMPLE B ... CHUNK SAMPLE ... DRIVE SAMPLE (UNDISTURBED) ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - - - 4 - - SAMPLE NO.LITHOLOGY~.j '!.- "-,. I - -, iI.-!• -1- _\l - .-I-}-'- :\ } - •1. ••--,. i-I.:1.};- •! t GROUNDWATER |SOIL CLASS (USCS) SM TRENCH T 6 ELEV. (MSL.) 295 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Very loose, (caving) saturated, moderate brown, Silty, fine to coarse SAND, trench caving, cannot enter, flowing water SANTIAGO FORMATION Medium dense to loose, damp to wet, mottled \ grays, pale and dark yellowish orange, moderately / \ weathered, massive, random discontinuous joints / \ stained black / TRENCH TERMINATED AT 7 FEET DID NOT ENTER CAVING TRENCH ENETRATIONRESISTANCEBLOWS/FT.)Q- ^ _ ~ -RY DENSITY(P.C.F.)a MOISTUREONTENT (X)u Figure A-6, Log of Trench T 6 PLR3 SAMPLE SYMBOLS D ... SAMPLING UNSUCCESSFUL l§ ... DISTURBED OR BAG SAMPLE C ... STANDARD PENETRATION TEST • ... DRIVE SAMPLE (UNDISTURBED) B ... CHUNK SAMPLE I ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ _ , - 4 - - 6 ~ - - 8 - ID SAMPLE NO. >-CDO O 1—H "1 1 - •"'' •)""1 'j \•1 j. "1 ' '• " r•j- 1 - •1 !-•-it"'j -f. --i j."1~ j "i-!~"i -1 * 1 L -•'• ' 'i. •-i -•i -.•i- r -i. ' ;|J'- ;l}; ]-!;. i ' "•It trLUi— ~T 2 O CD SOIL CLASS (USCS) SM SM SM SM TRENCH T 7 ELEV. (MSL.) 300 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION FILL Loose, dry, pale yellowish brown, Silty, fine to medium SAND COLLUVIUM Loose, damp, dark yellowish brown to moderate brown, Silty, fine to medium SAND Becomes moist to wet SANTIAGO FORMATION _. Medium dense, moist to wet very pale orange __ \ Silty, fine to medium SAND, massive / TRENCH TERMINATED AT 11 FEET z /-* °o ' L_ "^ I ««" ||| ^"^ ^^ fc> ||| ^-J Q. ^ _ >_ t—/^ fn • UJ(J ° • CZ^Ct s^ UJ"^rv 2$ g" O - Figure A-7, Log of Trench T 7 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) S ... DISTURBED OR BAG SAMPLE B ... CHUNK SAMPLE f. ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - - 4 -1 SAMPLE NO. T8-1 ;_LITHOLOG~.1 "' / . "-i. ] - v--1 1 -'}]'.' li . •i-!--- 1 1 -. .• i'i- 1i 1 1&. 1 . _- 1w -1 "1 a: UJ GROUNDUA1SOIL CLASS (USCS) SM SM TRENCH T 8 ELEV. (MSL.) 302 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOBL/COLLUVIUM Very loose, (caving) saturated, dark yellowish brown, Silty, fine to coarse SAND. Trench caving, cannot enter, flowing water -Heavy seepage at lower contact LINDAVISTA FORMATION Loose to medium dense, moist, mottled moderate brown, grayish orange and gray, Silty, fine to coarse SAND with rounded fine gravel TRENCH TERMINATED AT 5 FEET DID NOT ENTER CAVING TRENCH z /^ENETRATIORESISTANCEBLOWS/FT.Q- ^ _ — _ ^. ^ Q ^MOISTUREONTENT (.'/,o m Figure A-8, Log of Trench T 8 PLR3 SAMPLE SYMBOLS IH... SAMPLING UNSUCCESSFUL H ... DISTURBED OR BAG SAMPLE C... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) B ... CHUNK SAMPLE I ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ SAMPLE NO. 1 T9-1 LITHOLOGY• i i - "']• ' " It--1 u II ]•".-Jlrt -T9-2 [Ijljj 11 1 GROUNDWATERSOIL CLASS CUSCS) SM SM TRENCH T 9 ELEV. (MSL.) 324 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOEL/COLLUVIUM Loose, dry, moderate yellowish brown, Silty, fine to coarse SAND LINDAVISTA FORMATION Loose, dry to damp, light brown, Silty, fine to coarse SAND, trace of rounded fine gravel. Becomes medium dense below 3 feet TRENCH TERMINATED AT 4 FEET ENETRATIONRESISTANCEBLOWS/FT.)0. ^ _RY DENSITY(P.C.F.)Q 120.8 MOISTUREONTENT Mo 6.3 - Figure A-9, Log of Trench T 9 PLR3 SAMPLE SYMBOLS D ... SAMPLING UNSUCCESSFUL C ... STANDARD PENETRATION TEST I ... DRIVE SAMPLE (UNDISTURBED) H ... DISTURBED OR BAG SAMPLE G ... CHUNK SAMPLE JL ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 4 - ~ — SAMPLE NO. ,_LITHOLOGV!"i1 --1 1.:-i- ----j.i- ••]'•!"-" v -: |•" r]•- 1 {•*"-:!t. ceLU <n z occCO SOIL CLASS (USCS) SM SM TRENCH T10 ELEV. (MSL.) 338 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOEL/COLLUVIUM Loose, dry, moderate yellowish brown, Silty, fine to coarse SAND LINDAVISTA FORMATION Medium dense, dry to damp, light brown, mottled black, Silty, fine to coarse SAND, trace of rounded fine gravel TRENCH TERMINATED AT 6 FEET "2. s*.ENETRATIORESISTANCEBLOWS/FT.Q."-'W _ _ _ ~ ^_ t—^ gul go Q ^MOISTUREONTENT <•/.u Figure A-10, Log of Trench T 10 PLR3 SAMPLE SYMBOLS ... SAMPLING UNSUCCESSFUL ... DISTURBED OR BAG SAMPLE C... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) K ... CHUNK SAMPLE f. ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - - 4 - SAMPLE NO. Tll-1 5"= 1 1 LITHOLOGY::J:[:•i t:.j J-. ;[{". T"-2 lit - T""3 1|:-NDWATERaa SOIL CLASS (USCS) SM SM TRENCH Til ELEV. (MSL.) 344 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose, damp to wet, moderate yellowish brown, Silty, fine to coarse SAND, rootlets, porous LJNDAVISTA FORMATION Medium dense, damp, light brown, mottled gray, Silty, fine to coarse SAND TRENCH TERMINATED AT 5 FEET ENETRATIONRESISTANCEBLOWS/FT.)Q_«-^-' _ - ,RY DENSITY(P.C.F.)a 118.6 MOISTUREONTENT (X)a 9.4 - Figure A-ll, Log of Trench T 11 PLR3 SAMPLE SYMBOLS D ... SAMPLING UNSUCCESSFUL C ... STANDARD PENETRATION TEST H ... DISTURBED OR BAG SAMPLE K ... CHUNK SAMPLE •... DRIVE SAMPLE (UNDISTURBED) f. ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - - - 4 - - - 6 - SAMPLE NO.LITHOL06YV.-1- T -'j -T. - -\\,_ -V}- V-ji.. 'I-/'- V J -i. -- 1 j. -|.i'-'JNDWATERa C3 SOIL CLASS (USCS) SM SM TRENCH T 12 ELEV. (MSL.) 349 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION FELL Loose to medium dense, damp, moderate brown, Silty, fine to coarse SAND LINDAVISTA FORMATION Medium dense, damp, light and moderate brown, Silty, fine to coarse SAND TRENCH TERMINATED AT 6.5 FEET ENETRATIONRESISTANCEBLOWS/FT.)Q- ^ „ -RY DENSITY(P.C.F.)a MOISTUREONTENT (X.)u Figure A-12, Log of Trench T 12 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) H ... DISTURBED OR BAG SAMPLE B ... CHUNK SAMPLE 3P ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ - 2 - SAMPLE NO.LITHOLOGY|ri ^- j.•-M'-" _}t.. \'\GROUNDWATERSOIL CLASS (USCS) SM SM TRENCH T13 ELEV. (MSL.) 365 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION FILL Loose to medium dense, damp, light and moderate brown, Silty, fine to coarse SAND LJNDAVISTA FORMATION __ Medium dense, damp, light and moderate brown, \ Silty, fine to coarse SAND / TRENCH TERMINATED AT 4 FEET ENETRATIONRESISTANCEBLOWS/FT.)Q.1*-^ _RY DENSITY(P.C.F.)Q MOISTUREONTENT 00CJ - Figure A-13, Log of Trench T 13 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C . . . STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) ... DISTURBED OR BAG SAMPLE ... CHUNK SAMPLE I ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET - 2 - SAMPLE NO. T14-1 THOL06YH I}' '-I-!-- T-!' :'! (' rv JNDUATE0ceCD SOIL CLASS (USCS) SM SM TRENCH T 14 ELEV. (MSL.) 354 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose, damp, moderate brown, Silty, fine to medium SAND, rootlets LJNDAVISTA FORMATION Medium dense, damp, light brown, Silty, fine to coarse SAND TRENCH TERMINATED AT 3 FEET 'RATIONSTANCEIS/FT.)^co° Lu^^ - - Ei-gu! £cJo . >°-£~Q /^ US = 1-cnf?i H^ot ^0CJ Figure A-14, Log of Trench T 14 PLR3 SAMPLE SYMBOLS D ... SAMPLING UNSUCCESSFUL C . . . STANDARD PENETRATION TEST H ... DISTURBED OR BAG SAMPLE B ... CHUNK SAMPLE ... DRIVE SAMPLE (UNDISTURBED) . . . WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET . - 2 - SAMPLE NO. T15-1 I J LITHOL06Y• i - -.1-, •'1 . - \ "• - --t 1:k!.•i- -i-*GROUNDUATER |SOIL CLASS (USCS) SM 5M/ML TRENCH T 15 ELEV. (MSL.) 340 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSODL/COLLUVIUM Loose, wet (saturated) moderate brown to dark yellowish brown, Silty, fine to coarse SAND, rootlets -Seepage at contact LINDAVISTA FORMATION Loose to medium dense, wet to damp, mottled dark \ yellowish orange, gray, Silty, fine to medium / \ SAND/Sandy SILT / TRENCH TERMINATED AT 4 FEET PENETRATIONRESISTANCE(BLOWS/FT.)_ -DRY DENSITY(P.C.F.)MOISTURECONTENT (.'/.)Figure A-15, Log of Trench T 15 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) ... DISTURBED OR BAG SAMPLE K ... CHUNK SAMPLE I ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET . - 2 - - 4 - - SAMPLE NO. sT16-1 X X 3C')LITHOLO.1 -; h't . 'i •- 1 .-!• ' K '. ' - '. QLLU1—GROUNDUASOIL CLASS (USCS) SM SM SM/ML TRENCH T 16 ELEV. (MSL.) 320 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVTUM Loose, wet, dark yellowish brown to olive black, Silty, fine to coarse SAND, abundant organics ALLUVIUM Loose, (caving) wet/saturated, moderate yellowish brown, Silty,fine to coarse SAND. Trench caving, cannot enter, flowing water -Heavy seepage at contact LINDAVISTA FORMATION Loose to medium dense, mottled dark yellowish \ orange, gray, Silty, fine to medium SAND/Sandy / \ SILT / TRENCH TERMINATED AT 7 FEET DID NOT ENTER CAVING TRENCH Zi.i~i— i LU .ENETRATK?ESISTANCBLOUS/FTQ. ^ _ 5_ Id Q ^MOISTUREONTENT C0 • Figure A-16, Log of Trench T 16 PLR3 SAMPLE SYMBOLS D ... SAMPLING UNSUCCESSFUL C ... STANDARD PENETRATION TEST • ... DRIVE SAMPLE (UNDISTURBED) §§ ... DISTURBED OR BAG SAMPLE E ... CHUNK SAMPLE T. ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ SAMPLE NO. CDo LITHOL•-!T-' r- •r<-"1 ' •:-1 J.'1 1 -J" ' C£u <T c Q SOIL CLASS (USCS) SM SM TRENCH T 17 ELEV. (MSL.) 314 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose, moist, dark yellowish brown and olive black, Silty, fine to coarse SAND, abundant organics, highly odiferous LJNDAVISTA FORMATION Loose, wet, light brown, Silty, fine to coarse SAND -Becomes medium dense at 4 feet TRENCH TERMINATED AT 4 FEET ZLU~ENETRAT]JESISTANBLOWS/F1OL ^ _ Ijj Q ~ III *^MOISTURONTENT <u . Figure A-17, Log of Trench T 17 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C ... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) H ... DISTURBED OR BAG SAMPLE K ... CHUNK SAMPLE I ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ SAMPLE NO. T18-1 i CDa LITHOL"i !•'"•!•!1 \- 1 J. A\'~-'1 rtn {£U <r GROUNDUSOIL CLASS (USCS) SM SM TRENCH T 18 ELEV. (MSL.) 324 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose, dry, moderate to dark yellowish brown, Silty, fine to medium SAND, rootlets LINDAVISTA FORMATION Medium dense, moist, light brown, Silty, fine to coarse SAND with fine rounded gravel / TRENCH TERMINATED AT 3 FEET zui~i» CJ i ENETRAT]?ESISTANBLOUS/Fltt. s^' _ ^d o 118.2 ~ LU i MOISTURONTENT <o 7.9 Figure A-18, Log of Trench T 18 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C ... STANDARD PENETRATION TEST •... DRIVE SAMPLE (UNDISTURBED) H ... DISTURBED OR BAG SAMPLE B ... CHUNK SAMPLE T. ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. PROJECT NO. 06313-12-01 DEPTH IN FEET _ *•>z .. - 4 - SAMPLE NO.LITHOLOGYT-- •j I :i|-- A\''-~\ • -i•i.j-- jl:GROUNDWATER ISOIL CLASS (USCS) SM SM TRENCH T 19 ELEV. (MSL.) 297 DATE COMPLETED 5/17/99 EQUIPMENT JD 555 MATERIAL DESCRIPTION TOPSOIL/COLLUVIUM Loose, dry, pale yellowish brown, Silty, fine to medium SAND SANTIAGO FORMATION Medium dense, dry to moist, light brown, fine to coarse Silty SAND TRENCH TERMINATED AT 5 FEET ENETRATIONRESISTANCEBLOWS/FT.)Q."-^ _ _RY DENSITY(P.C.F.)a MOISTUREONTENT (*)a - Figure A-19, Log of Trench T 19 PLR3 SAMPLE SYMBOLS D... SAMPLING UNSUCCESSFUL C... STANDARD PENETRATION TEST H ... DISTURBED OR BAG SAMPLE B . . . CHUNK SAMPLE ... DRIVE SAMPLE (UNDISTURBED) ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. c I I I I £ E I I I 1 E I I I I I I I APPENDtX APPENDIX B LABORATORY TESTING Laboratory tests were performed in accordance with generally accepted test methods of the American Society for Testing and Materials (ASTM) or other suggested procedures. Selected samples were tested for their in-place density and moisture content, direct shear strength, expansion, and maximum dry density and optimum moisture content. The results of these tests are summarized on Tables B-I through B-III and the in-place dry density and moisture content results are indicated on the exploratory trench logs. TABLE B-I SUMMARY OF LABORATORY MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT TEST RESULTS ASTM D 1557-91 Sample No. T3-2 Tll-2 Description Pale Yellowish, Brown, Clayey, fine to medium SAND Light Brown Silty, fine to coarse SAND Maximum Dry Density (pcf) 119.5 127.0 Optimum Moisture Content (% dry wt.) 12.0 10.8 TABLE B-ll SUMMARY OF LABORATORY DIRECT SHEAR TEST RESULTS* Sample No. T3-2 Dry Density (pcf) 107.5 Moisture Content (%) 12.2 Unit Cohesion (psf) 390 Angle of Shear Resistance (degrees) 28 "Soil sample was remolded to 90 percent relative density at near optimum moisture content. TABLE B-III SUMMARY OF LABORATORY EXPANSION INDEX TEST RESULTS Sample No. T15-1 Moisture Content Before Test (%) 8.0 After Test (%) 23.7 Dry Density (pcf) 117.5 Expansion Index 2 Classification Very Low Project No. 06313-12-01 June 10, 1999 C G G G G I C C C C C C G I I I I I I APPENDIX APPENDIX C RECOMMENDED GRADING SPECIFICATIONS FOR POINSETTIA LANE ("REACH 3") CARLSBAD, CALIFORNIA PROJECT NO. 06313-12-01 RECOMMENDED GRADING SPECIFICATIONS 1. GENERAL 1.1. These Recommended Grading Specifications shall be used in conjunction with the Geotechnical Report for the project prepared by Geocon Incorporated. The recom- mendations contained in the text of the Geotechnical Report are a part of the earthwork and grading specifications and shall supersede the provisions contained hereinafter in the case of conflict. 1.2. Prior to the commencement of grading, a geotechnical consultant (Consultant) shall be employed for the purpose of observing earthwork procedures and testing the fills for substantial conformance with the recommendations of the Geotechnical Report and these specifications. It will be necessary that the Consultant provide adequate testing and observation services so that he may determine that, in his opinion, the work was performed in substantial conformance with these specifications. It shall be the responsibility of the Contractor to assist the Consultant and keep him apprised of work schedules and changes so that personnel may be scheduled accordingly. 1.3. It shall be the sole responsibility of the Contractor to provide adequate equipment and methods to accomplish the work in accordance with applicable grading codes or agency ordinances, these specifications and the approved grading plans. If, in the opinion of the Consultant, unsatisfactory conditions such as questionable soil materials, poor moisture condition, inadequate compaction, adverse weather, and so forth, result in a quality of work not in conformance with these specifications, the Consultant will be empowered to reject the work and recommend to the Owner that construction be stopped until the unacceptable conditions are corrected. 2. DEFINITIONS 2.1. Owner shall refer to the owner of the property or the entity on whose behalf the grading work is being performed and who has contracted with the Contractor to have grading performed. 2.2. Contractor shall refer to the Contractor performing the site grading work. 2.3. Civil Engineer or Engineer of Work shall refer to the California licensed Civil Engineer or consulting firm responsible for preparation of the grading plans, surveying and verifying as-graded topography. GI rev. 8/98 2.4. Consultant shall refer to the soil engineering and engineering geology consulting firm retained to provide geotechnical services for the project. 2.5. Soil Engineer shall refer to a California licensed Civil Engineer retained by the Owner, who is experienced in the practice of geotechnical engineering. The Soil Engineer shall be responsible for having qualified representatives on-site to observe and test the Contractor's work for conformance with these specifications. 2.6. Engineering Geologist shall refer to a California licensed Engineering Geologist retained by the Owner to provide geologic observations and recommendations during the site grading. 2.7. Geotechnical Report shall refer to a soil report (including all addenda) which may include a geologic reconnaissance or geologic investigation that was prepared specifically for the development of the project for which these Recommended Grading Specifications are intended to apply. 3. MATERIALS 3.1. Materials for compacted fill shall consist of any soil excavated from the cut areas or imported to the site that, in the opinion of the Consultant, is suitable for use in construction of fills. In general, fill materials can be classified as soil fills, soil-rock fills or rock fills, as defined below. 3.1.1. Soil fills are defined as fills containing no rocks or hard lumps greater than 12 inches in maximum dimension and containing at least 40 percent by weight of material smaller than 3/4 inch in size. 3.1.2. Soil-rock fills are defined as fills containing no rocks or hard lumps larger than 4 feet in maximum dimension and containing a sufficient matrix of soil fill to allow for proper compaction of soil fill around the rock fragments or hard lumps as specified in Paragraph 6.2. Oversize rock is defined as material greater than 12 inches. 3.1.3. Rock fills are defined as fills containing no rocks or hard lumps larger than 3 feet in maximum dimension and containing little or no fines. Fines are defined as material smaller than 3/4 inch in maximum dimension. The quantity of fines shall be less than approximately 20 percent of the rock fill quantity. ' GI rev. 8/98 3.2. Material of a perishable, spongy, or otherwise unsuitable nature as determined by the Consultant shall not be used in fills. 3.3. Materials used for fill, either imported or on-site, shall not contain hazardous materials as defined by the California Code of Regulations, Title 22, Division 4, Chapter 30, Articles 9 and 10; 40CFR; and any other applicable local, state or federal laws. The Consultant shall not be responsible for the identification or analysis of the potential presence of hazardous materials. However, if observations, odors or soil discoloration cause Consultant to suspect the presence of hazardous materials, the Consultant may request from the Owner the termination of grading operations within the affected area. Prior to resuming grading operations, the Owner shall provide a written report to the Consultant indicating that the suspected materials are not hazardous as defined by applicable laws and regulations. 3.4. The outer 15 feet of soil-rock fill slopes, measured horizontally, should be composed of properly compacted soil fill materials approved by the Consultant. Rock fill may extend to the slope face, provided that the slope is not steeper than 2:1 (horizontal:vertical) and a soil layer no thicker than 12 inches is track-walked onto the face for landscaping purposes. This procedure may be utilized, provided it is acceptable to the governing agency, Owner and Consultant. 3.5. Representative samples of soil materials to be used for fill shall be tested in the laboratory by the Consultant to determine the maximum density, optimum moisture content, and, where appropriate, shear strength, expansion, and gradation characteristics of the soil. 3.6. During grading, soil or groundwater conditions other than those identified in the Geotechnical Report may be encountered by the Contractor. The Consultant shall be notified immediately to evaluate the significance of the unanticipated condition 4. CLEARING AND PREPARING AREAS TO BE FILLED 4.1. Areas to be excavated and filled shall be cleared and grubbed. Clearing shall consist of complete removal above the ground surface of trees, stumps, brush, vegetation, man-made structures and similar debris. Grubbing shall consist of removal of stumps, roots, buried logs and other unsuitable material and shall be performed in areas to be graded. Roots and other projections exceeding 1-1/2 inches in diameter shall be removed to a depth of 3 feet below the surface of the ground. Borrow areas shall be grubbed to the extent necessary to provide suitable fill materials. GI rev. 8/98 4.2. Any asphalt pavement material removed during clearing operations should be properly disposed at an approved off-site facility. Concrete fragments which are free of reinforcing steel may be placed in fills, provided they are placed in accordance with Section 6.2 or 6.3 of this document. 4.3. After clearing and grubbing of organic matter or other unsuitable material, loose or porous soils shall be removed to the depth recommended in the Geotechnical Report. The depth of removal and compaction shall be observed and approved by a representative of the Consultant. The exposed surface shall then be plowed or scarified to a minimum depth of 6 inches and until the surface is free from uneven features that would tend to prevent uniform compaction by the equipment to be used. 4.4. Where the slope ratio of the original ground is steeper than 6:1 (horizontahvertical), or where recommended by the Consultant, the original ground should be benched in accordance with the following illustration. TYPICAL BENCHING DETAIL Finish Grade Original Ground Finish Slope Surface Remove All Unsuitable Material As Recommended By Soil Engineer Slope To Be Such That Sloughing Or Sliding Does Not Occur See Note 1 See Note 2 -1 No Scale DETAIL NOTES:(1) Key width "B" should be a minimum of 10 feet wide, or sufficiently wide to permit complete coverage with the compaction equipment used. The base of the key should be graded horizontal, or inclined slightly into the natural slope. (2) The outside of the bottom key should be below the topsoil or unsuitable surficial material and at least 2 feet into dense formational material. Where hard rock is exposed in the bottom of the key, the depth and configuration of the key may be modified as approved by the Consultant. GI rev. 8/98 4.5. After areas to receive fill have been cleared, plowed or scarified, the surface should be disced or bladed by the Contractor until it is uniform and free from large clods. The area should then be moisture conditioned to achieve the proper moisture content, and compacted as recommended in Section 6.0 of these specifications. 5. COMPACTION EQUIPMENT 5.1. Compaction of soil or soil-rock fill shall be accomplished by sheepsfoot or segmented-steel wheeled rollers, vibratory rollers, multiple-wheel pneumatic-tired rollers, or other types of acceptable compaction equipment. Equipment shall be of such a design that it will be capable of compacting the soil or soil-rock fill to the specified relative compaction at the specified moisture content. 5.2. Compaction of rock fills shall be performed in accordance with Section 6.3. 6. PLACING, SPREADING AND COMPACTION OF FILL MATERIAL 6.1. 50/7 fill, as defined in Paragraph 3.1.1, shall be placed by the Contractor in accordance with the following recommendations: 6.1.1. Soil fill shall be placed by the Contractor in layers that, when compacted, should generally not exceed 8 inches. Each layer shall be spread evenly and shall be thoroughly mixed during spreading to obtain uniformity of material and moisture in each layer. The entire fill shall be constructed as a unit in nearly level lifts. Rock materials greater than 12 inches in maximum dimension shall be placed in accordance with Section 6.2 or 6.3 of these specifications. 6.1.2. In general, the soil fill shall be compacted at a moisture content at or above the optimum moisture content as determined by ASTM D1557-91. 6.1.3. When the moisture content of soil fill is below that specified by the Consultant, water shall be added by the Contractor until the moisture content is in the range specified. 6.1.4. When the moisture content of the soil fill is above the range specified by the Consultant or too wet to achieve proper compaction, the soil fill shall be aerated by the Contractor by blading/mixing, or other satisfactory methods until the moisture content is within the range specified. GI rev. 8/98 6.1.5. After each layer has been placed, mixed, and spread evenly, it shall be thoroughly compacted by the Contractor to a relative compaction of at least 90 percent. Relative compaction is defined as the ratio (expressed in percent) of the in-place dry density of the compacted fill to the maximum laboratory dry density as determined in accordance with ASTM D1557-91. Compaction shall be continuous over the entire area, and compaction equipment shall make sufficient passes so that the specified minimum relative compaction has been achieved throughout the entire fill. 6.1.6. Soils having an Expansion Index of greater than 50 may be used in fills if placed at least 3 feet below finish pad grade and should be compacted at a moisture content generally 2 to 4 percent greater than the optimum moisture content for the material. 6.1.7. Properly compacted soil fill shall extend to the design surface of fill slopes. To achieve proper compaction, it is recommended that fill slopes be over-built by at least 3 feet and then cut to the design grade. This procedure is considered preferable to track-walking of slopes, as described in the following paragraph. 6.1.8. As an alternative to over-building of slopes, slope faces may be back-rolled with a heavy-duty loaded sheepsfoot or vibratory roller at maximum 4-foot fill height intervals. Upon completion, slopes should then be track-walked with a D-8 dozer or similar equipment, such that a dozer track covers all slope surfaces at least twice. 6.2. Soil-rock fill, as defined in Paragraph 3.1.2, shall be placed by the Contractor in accordance with the following recommendations: 6.2.1. Rocks larger than 12 inches but less than 4 feet in maximum dimension may be incorporated into the compacted soil fill, but shall be limited to the area measured 15 feet minimum horizontally from the slope face and 5 feet below finish grade or 3 feet below the deepest utility, whichever is deeper. 6.2.2. Rocks or rock fragments up to 4 feet in maximum dimension may either be individually placed or placed in windrows. Under certain conditions, rocks or rock fragments up to 10 feet in maximum dimension may be placed using similar methods. The acceptability of placing rock materials greater than 4 feet in maximum dimension shall be evaluated during grading as specific cases arise and shall be approved by the Consultant prior to placement. GI rev. 8/98 6.2.3. For individual placement, sufficient space shall be provided between rocks to allow for passage of compaction equipment. 6.2.4. For windrow placement, the rocks should be placed in trenches excavated in properly compacted soil fill. Trenches should be approximately 5 feet wide and 4 feet deep in maximum dimension. The voids around and beneath rocks should be filled with approved granular soil having a Sand Equivalent of 30 or greater and should be compacted by flooding. Windrows may also be placed utilizing an "open-face" method in lieu of the trench procedure, however, this method should first be approved by the Consultant. 6.2.5. Windrows should generally be parallel to each other and may be placed either parallel to or perpendicular to the face of the slope depending on the site geometry. The minimum horizontal spacing for windrows shall be 12 feet center-to-center with a 5-foot stagger or offset from lower courses to next overlying course. The minimum vertical spacing between windrow courses shall be 2 feet from the top of a lower windrow to the bottom of the next higher windrow. 6.2.6. All rock placement, fill placement and flooding of approved granular soil in the windrows must be continuously observed by the Consultant or his representative. 6.3. Rock fills, as defined in Section 3.1.3., shall be placed by the Contractor in accordance with the following recommendations: 6.3.1. The base of the rock fill shall be placed on a sloping surface (minimum slope of 2 percent, maximum slope of 5 percent). The surface shall slope toward suitable subdrainage outlet facilities. The rock fills shall be provided with subdrains during construction so that a hydrostatic pressure buildup does not develop. The subdrains shall be permanently connected to controlled drainage facilities to control post-construction infiltration of water. 6.3.2. Rock fills shall be placed in lifts not exceeding 3 feet. Placement shall be by rock trucks traversing previously placed lifts and dumping at the edge of the currently placed lift. Spreading of the rock fill shall be by dozer to facilitate seating of the rock. The rock fill shall be watered heavily during placement. Watering shall consist of water trucks traversing in front of the current rock lift face and spraying water continuously during rock placement. Compaction equipment with compactive energy comparable to or greater than that of a 20-ton steel vibratory roller or other compaction equipment providing suitable energy to achieve the GI rev. 8/98 required compaction or deflection as recommended in Paragraph 6.3.3 shall be utilized. The number of passes to be made will be determined as described in Paragraph 6.3.3. Once a rock fill lift has been covered with soil fill, no additional rock fill lifts will be permitted over the soil fill. 6.3.3. Plate bearing tests, in accordance with ASTM Dl 196-64, may be performed in both the compacted soil fill and in the rock fill to aid in determining the number of passes of the compaction equipment to be performed. If performed, a minimum of three plate bearing tests shall be performed in the properly compacted soil fill (minimum relative compaction of 90 percent). Plate bearing tests shall then be performed on areas of rock fill having two passes, four passes and six passes of the compaction equipment, respectively. The number of passes required for the rock fill shall be determined by comparing the results of the plate bearing tests for the soil fill and the rock fill and by evaluating the deflection variation with number of passes. The required number of passes of the compaction equipment will be performed as necessary until the plate bearing deflections are equal to or less than that determined for the properly compacted soil fill. In no case will the required number of passes be less than two. 6.3.4. A representative of the Consultant shall be present during rock fill operations to verify that the minimum number of "passes" have been obtained, that water is being properly applied and that specified procedures are being followed. The actual number of plate bearing tests will be determined by the Consultant during grading. In general, at least one test should be performed for each approximately 5,000 to 10,000 cubic yards of rock fill placed. 6.3.5. Test pits shall be excavated by the Contractor so that the Consultant can state that, in his opinion, sufficient water is present and that voids between large rocks are properly filled with smaller rock material. In-place density testing will not be required in the rock fills. 6.3.6. To reduce the potential for "piping" of fines into the rock fill from overlying soil fill material, a 2-foot layer of graded filter material shall be placed above the uppermost lift of rock fill. The need to place graded filter material below the rock should be determined by the Consultant prior to commencing grading. The gradation of the graded filter material will be determined at the time the rock fill is being excavated. Materials typical of the rock fill should be submitted to the Consultant in a timely manner, to allow design of the graded filter prior to the commencement of rock fill placement. GI rev. 8/98 6.3.7. All rock fill placement shall be continuously observed during placement by representatives of the Consultant. 7. OBSERVATION AND TESTING 7.1. The Consultant shall be the Owners representative to observe and perform tests during clearing, grubbing, filling and compaction operations. In general, no more than 2 feet in vertical elevation of soil or soil-rock fill shall be placed without at least one field density test being performed within that interval. In addition, a minimum of one field density test shall be performed for every 2,000 cubic yards of soil or soil-rock fill placed and compacted. 7.2. The Consultant shall perform random field density tests of the compacted soil or soil-rock fill to provide a basis for expressing an opinion as to whether the fill material is compacted as specified. Density tests shall be performed in the compacted materials below any disturbed surface. When these tests indicate that the density of any layer of fill or portion thereof is below that specified, the particular layer or areas represented by the test shall be reworked until the specified density has been achieved. 7.3. During placement of rock fill, the Consultant shall verify that the minimum number of passes have been obtained per the criteria discussed in Section 6.3.3. The Consultant shall request the excavation of observation pits and may perform plate bearing tests on the placed rock fills. The observation pits will be excavated to provide a basis for expressing an opinion as to whether the rock fill is properly seated and sufficient moisture has been applied to the material. If performed, plate bearing tests will be performed randomly on the surface of the most-recently placed lift. Plate bearing tests will be performed to provide a basis for expressing an opinion as to whether the rock fill is adequately seated. The maximum deflection in the rock fill determined in Section 6.3.3 shall be less than the maximum deflection of the properly compacted soil fill. When any of the above criteria indicate that a layer of rock fill or any portion thereof is below that specified, the affected layer or area shall be reworked until the rock fill has been adequately seated and sufficient moisture applied. 7.4. A settlement monitoring program designed by the Consultant may be conducted in areas of rock fill placement. The specific design of the monitoring program shall be as recommended in the Conclusions and Recommendations section of the project Geotechnical Report or in the final report of testing and observation services performed during grading. GI rev. 8/98 7.5. The Consultant shall observe the placement of subdrains, to verify that the drainage devices have been placed and constructed in substantial conformance with project specifications. 7.6. Testing procedures shall conform to the following Standards as appropriate: 7.6.1. Soil and Soil-Rock Fills: 7.6.1.1. Field Density Test, ASTM D1556-82, Density of Soil In-Place By the Sand-Cone Method. 7.6.1.2. Field Density Test, Nuclear Method, ASTM D2922-81, Density of Soil and Soil-Aggregate In-Place by Nuclear Methods (Shallow Depth). 7.6.1.3. Laboratory Compaction Test, ASTM D1557-91, Moisture-Density Relations of Soils and Soil-Aggregate Mixtures Using 10-Pound Hammer and 18-Inch Drop. 7.6.1.4. Expansion Index Test, Uniform Building Code Standard 29-2, Expansion Index Test. 7.6.2. Rock Fills 7.6.2.1. Field Plate Bearing Test, ASTM Dl 196-64 (Reapproved 1977) Standard Method for Nonrepresentative Static Plate Load Tests of Soils and Flexible Pavement Components, For Use in Evaluation and Design of Airport and Highway Pavements. 8. PROTECTION OF WORK 8.1. During construction, the Contractor shall properly grade all excavated surfaces to provide positive drainage and prevent ponding of water. Drainage of surface water shall be controlled to avoid damage to adjoining properties or to finished work on the site. The Contractor shall take remedial measures to prevent erosion of freshly graded areas until such time as permanent drainage and erosion control features have been installed. Areas subjected to erosion or sedimentation shall be properly prepared in accordance with the Specifications prior to placing additional fill or structures. 8.2. After completion of grading as observed and tested by the Consultant, no further excavation or filling shall be conducted except in conjunction with the services of the Consultant. GI rev. 8/98 9. CERTIFICATIONS AND FINAL REPORTS 9.1. Upon completion of the work, Contractor shall furnish Owner a certification by the Civil Engineer stating that the lots and/or building pads are graded to within 0.1 foot vertically of elevations shown on the grading plan and that all tops and toes of slopes are within 0.5 foot horizontally of the positions shown on the grading plans. After installation of a section of subdrain, the project Civil Engineer should survey its location and prepare an as-built plan of the subdrain location. The project Civil Engineer should verify the proper outlet for the subdrains and the Contractor should ensure that the drain system is free of obstructions. 9.2. The Owner is responsible for furnishing a final as-graded soil and geologic report satisfactory to the appropriate governing or accepting agencies. The as-graded report should be prepared and signed by a California licensed Civil Engineer experienced in geotechnical engineering and by a California Certified Engineering Geologist, indicating that the geotechnical aspects of the grading were performed in substantial conformance with the Specifications or approved changes to the Specifications. GI rev. 8/98