HomeMy WebLinkAboutCD 2017-0013; THE BEACON; SITE PACKAGE SUPPLEMENTAL CALCULATIONS FOR REVISION; 2018-11-07r 1J NIC Consultants 1iECORf> COPY 0 J {I,/ N.JS _} ·!.I ::J!1 r ll ,2 t ----- The Beacon Project No. 1818.03 Site Package Supplemental Calculations For Revision Prepared: November 7, 2018 REC ~1V NOV 14 20'8 LAND OE:Vi=LOPMENT LNGINEE:.RING STRUC:TURAL ENGINEERING C:ONSUL TANTS 23 Corporate Plaza Dr., Newport Beach, CA 92660. www.NIC-ENG.com P. (949) 629-2529, F. (949) 6292501 Beacon Site Package Table of Contents: • Calculation for Eccentric Retaining Walls (Detail 1 /S30) • Calculation for Restraint Retaining Walls (Detail 2/S30) • Calculation for Eccentric Retaining Walls (Detail 3/S39) • Calculation for Cantilevered Retaining Walls (Detail 4/S30) • Calculation for Cantilevered Retaining Walls (Detail 5/S30) NIC Consultants 23 Corporate Plaza Dr., Newport Beach, CA 92660. www.NIC-ENG.com P. (949) 629-2529, F. (949) 629-2501 Project Name/Number : NIC Consultants Title Beac~m. Detail 1/ S30 Page : 1 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package Dsgnr: Touraj Eimani Description .... Date: 7 SEP 2018 Beacon, Eccentric, 1/S30 This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 license: KW-06011040 Cantilevered Retaining Wall license To : RetalnPro Development Center Code: IBC 2018,ACI 318-14,TMS 402-16 1 Criteria I I Soil Data I Retained Height 5.00 ft Wall height above soil = 1.50 ft Slope Behind Wall = 0.00 Allow Soil Bearing = 3,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 40.0 psf/ft Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft = Passive Pressure = 200.0 psf/ft Soil Density, Heel 110.00 pcf Soil Density, Toe = 110.00 pcf Footingl!Soil Friction 0.300 Soil height to ignore for passive pressure = 18.00 in 7 L Surcharge Loads I I Lateral Load Applied to Stem I [ Adjacent Footing Lo~ Surcharge Over Heel 40.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning [3xjaf Load A~d to Ste~ • Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity 0.0 in [ Design Summary ) Wall Stability Ratios Overturning Sliding Total Bearing Load ... resultant ecc. 1.54 OK 1.76 OK 3,005 lbs 13.33 in Soil Pressure @ Toe = 2,623 psf OK Soil Pressure @ Heel = O psf OK Allowable 3,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe 3,672 psf ACI Factored @ Heel = O psf Footing Shear@ Toe Footing Shear @ Heel = Allowable Sliding Cales Lateral Sliding Force = 1.2 psi OK 12.5 psi OK 82.2 psi less 100% Passive Force = - less 100% Friction Force = 1,293.3 lbs 1,375.0 lbs 901 .6 lbs Added Force Req'd .... for 1.5 Stability = 0.0 lbs OK 0.0 lbs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors - Building Code Dead Load Live Load Earth, H Wind,W Seismic, E IBC 2018,ACI 1.200 1.600 1.600 1.000 1.000 Lateral Load 486.0 #/ft Adjacent Footing Load ... Height to Top = 4.75 ft Footing Width ... Height to Bottom 3.75 ft Eccentricity Load Type Seismic (E) Wall to Ftg CL Dist (Service Level) Footing Type Base Above/Below Soil Wind on Exposed Stem = 0.0 psf at Back of Wall (Service Level) Poisson's Ratio Bottom l§!em Construction I ---- Design Height Above Ftg Wall Material Above "HI" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force@ Section Service Level Strength Level Moment....Actual Service Level Strength Level Moment. .... Allowable Shear ..... Actual ft= = = = = = lbs= lbs= ft-#= ft-#= Service Level psi= Strength Level psi= Shear ..... Allowable psi= Stem OK 0.00 Concrete LRFD 8.00 # 5 16.00 Edge ---- 0.592 1,402.4 3,689.7 6,234.5 18.9 82.2 ASD Anet (Masonry) in2 = 139.50 Rebar Depth 'd' in= 6.19 Masonry Data fm psi = Fs Solid Grouting Modular Ratio 'n' Wall Weight Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy psi= psf= 100.0 Normal Weight ASD psi= 3,000.0 psi= 60,000.0 0.0 lbs = 0.00 ft = 0.00 in = 0.00 ft Line Load = 0.0 ft 0.300 I Project Name/Number : NIC Consultants Title Beac~>n, Detail 1/ S30 Page : 2 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package Dsgnr: Touraj Eimani Description .... Date: 7 SEP 2018 Beacon, Eccentric, 1/S30 This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW--06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Concrete Stem Rebar Area Details Bottom Stem As (based on applied moment) : (4/3) * As : Horizontal Reinforcing Min Stem T&S Reinf Area 1.248 in2 200bd/fy : 200(12)(6.1875)/60000 : 0.0018bh : 0.0018(12)(8) : Vertical Reinforcing 0.1397 in2/ft 0.1863 in2/ft 0.2475 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.1728 in2/ft Horizontal Reinforcing Options : ------------One layer of : Two layers of : Required Area : 0.1863 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area : 0.2325 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area : 1.0059 in2/ft #6@ 27.50 in #6@ 55.00 in 1 Footing[)imensions&StrengthQ : Footing Design Res~ ) Toe Width = 0.75 ft Toe Heel Heel Width = 3.00 Factored Pressure = 3,672 O psf Total Footing Width = 3.75 Mu': Upward = 920 179 ft-# Footing Thickness 12.00 in Mu': Downward = 69 2,461 ft-# Mu: Design 851 2,282 ft-# Key Width 12·00 in Actual 1-Way Shear 1.17 12.46 psi Key Depth 3o.oo in Allow 1-Way Shear 43.82 43.82 psi Key Distance from Toe = 2.75 ft Toe Reinforcing = # 6@ 12.00 in fc = 3,000 psi Fy = 60,000 psi Heel Reinforcing = # 5 @ 12.00 in Footing Concrete Density 150.00 pcf Key Reinforcing = # 6@ 12.00 in Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover@ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm Heel: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm Key: #4@ 9.26 in, #5@ 14.35 in, #6@ 18 in, #7@ 18 in, #8@ 18 Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@20.37 in Summary of Overturning & Resisting Forces & Moments 0.97 in2 0.26 in2 1ft If two layers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@40.74 in ..... OVERTURNING ..... . .... RESISTING ..... Force Distance Moment Item lbs ft ft-# Heel Active Pressure 720.0 Surcharge over Heel = 87.3 Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load 486.0 Load @ Stem Above Soil = Total 1,293.3 Resisting/Overturning Ratio Vertical Loads used for Soil Pressure = 2.00 1,440.0 3.00 261 .8 5.25 2,551 .5 O.T.M. 4,253.3 = 1.54 3,005.4 lbs Force Distance lbs ft --- Soil Over Heel Sloped Soil Over Heel Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem Soil Over Toe Surcharge Over Toe = Stem Weight(s) Earth @ Stem Transitions= Footing Weight Key Weight = Vert. Component = 1,283.3 2.58 93.3 41.3 650.0 562.5 375.0 2.58 0.38 1.08 1.88 3.25 Moment ft-# 3,315.3 241 .1 15.5 704.2 1,054.7 1,218.8 Total= 3,005.4 lbs R.M.= 6,549.5 Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. • Axial live load NOT included in total displayed1 or used for overturning resistance, but is included for soil pressure ca1culation. • Project Name/Number : NIC Consultants Title Beac~n. Detail 1/ 530 Page : 3 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Dsgnr: Touraj Eimani Description .... Beacon, Eccentric, 1/S30 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 Cantilevered Retaining Wall License To : RetainPro Development Center ITTt I Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus Horizontal Defl @ Top of Wall (approximate only) 250.0 pci 0.126 in The above calculation rs not valid rf the heel sorl bearing pressure exceeds that of the toe, because the wall would then tend to rotate rnto the retained sorl Date: 7 SEP 2018 Code: IBC 2018,ACI 318-14,TMS 402-16 Project Name/Number : NIC Consultants Title Beacpn, Detail 1/ S30 Page : 4 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Dsgnr: Touraj Eimani Description .... Beacon, Eccentric, 1/S30 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Lap Splice length for #5 bar specified in this stem design segment= Development length for #5 bar specified in this stem design segment = Hooked embedment length into footing for #5 bar specified in this stem design segment = As Provided = As Required = Date: 7 SEP 2018 Code: IBC 2018,ACI 318-1 4,TMS 402-16 21.36 in 16.43 in 7.68 in 0.2325 in2/ft 0.1863 in2/ft NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~n. Detail 1/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric, 1/S30 Page : 5 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 8" w/ #5@ 16" 1'-6" • • 6'-6 " • 5'-0" • 6" 2" #6~12.in • @ o·e 3" #6<@ 12.in @ enter On Key '-6" #5@12" @ Heel 2'-9" 1'~0" 9" 3'-0" 3'-9" NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~n. Detail 1/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric, 1/S30 Page : 6 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetalnPro Development Center Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 486.00psf (Service-Level' Pp= 1375.00# ...... <n a. N I,{) N N (0 40.00psf ill 1293# r Project Name/Number : NIC Consultants Title Beac~m. Detail 1/ S30 Page : 7 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package Dsgnr: Touraj Eimani Description .... Date: 7 SEP 2018 This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Masonry Beacon, Eccentric, 1/S30 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Designer to determine bar cutoff locations 160.0 lbs 480.0 lbs 800.0 lbs 1, 1 0.0 lbs 1, 0.0 lbs 0.0 lbs 320.0 lbs 640.0 lbs 960.0 lbs 1,2 0.0 lbs ... ~--,111111 ·····-111111 ,1111 . I 11111111 i I :~"I NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~>n, Detail 1/ 530 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric, 1/530 Page : 8 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Development Center 6.5 5.00 Masonry Allowable Moment line Masonry Designer to determine bar cutoff locations 690.0 ft-# 2,070.0 ft-# 3,4 0.0 ft-# 4,8 0.0 ft-# 6,2 0.0 ft-# 1,3 0.0 ft-# 2,7 0.0 ft-# 4, 1 0.0 ft-# 5,5 0.0 ft-# Mu = 3, MnPhi = NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beacpn, Detail 2/ S30 Dsgnr: Project Designer ... Description .... Beacon, Restraint, 10-ft, 2/S30 Page : 1 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License: KW-06011040 Restrained Retaining Wall License To : RetainPro Development Center Code: IBC 2018,ACI 318-14,TMS 402-16 Criteria I Soil Data I -------------· ~----------------Retained Height = 10.00ft Allow Soil Bearing = 3,000.0 psf Wall height above soil = 1.50 ft Equivalent Fluid Pressure Method Total Wall Height 11.50 ft At-rest Heel Pressure 60.0 psf/ft Top Support Height = 10.00 ft Passive Pressure = 360.0 psf/ft Soil Density 110.00 pcf Slope Behind Wal = 0.00 Footingl!Soil Frictior = 0.400 Height of Soil over Toe 24.00 in Soil height to ignore for passive pressure = 12.00 in Thumbnail Surcharge Loads I L Uniform Lateral Load Applied to Stem • [ Adjacent Footing Load Surcharge Over Heel 40.0 psf »>Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning J Axial Load Applied to St;;-I Axial Dead Load = Axial Live Load Axial Load Eccentricity 0.0 lbs 0.0 lbs 0.0 in Lateral Load 1,633.0 #/ft ... Height to Top = 7.50 ft ... Height to Bottorr Load Type Wind on Exposed Stem = 6.50 ft Seismic (E) (::itrengtn Level) 0.0 psf Adjacent Footing Load Footing Width Eccentricity Wall to Fig CL Dist Footing Type Base Above/Below Soil at Back of Wall Poisson's Ratio / Earth Pressure Seismic Load I Kh Soil Density Multiplier = 0.500 g Added seismic per unit area -~~~~~~ .s.te•m-W-ei•g•h•t•S•e•is•m•i•c•L•o•a•d ___ J __ . Fp / WP Weight Multiplier = 0.000 g Added seismic per unit area L.o.e.s.ig11n_s.u.m_m.a.ry .. ______ ----, __ 1~oncr~tem Construction -- Total Bearing Load = 2,729 ~bs Thickness = 8.00 in Fy 60,000 psi ... resultant ecc. = 0.00 m Wall Weight = 100.0 psf fc = 3,000 psi Soil Pressure @ Toe = O psf OK Soil Pressure @ Heel = O psf OK Allowable 3,000 psf Soil Pressure Less Than Allowable ACI Factored@ Toe = 0 psf ACI Factored@ Heel O psf Footing Shear@ Toe = 0.0 psi OK Footing Shear@ Heel = 0.0 psi OK Allowable 82.2 psi Reaction at Top = 2,251.1 lbs Reaction at Bottom 3,423.1 lbs Sliding Stability Ratio = 1. 72 OK Sliding Cales Lateral Sliding Force = less 100% Passive Force= - less 100% Friction Force= - Added Force Req'd = .... for 1.5 Stability 3,423.1 lbs 4,781.3 lbs 1,091.4 lbs 0.0 lbs OK 0.0 lbs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Stem is FREE to rotate at top of footing Design Height Above Ft!, Rebar Size Rebar Spacing Rebar Placed at Rebar Depth 'd' Design Data fb/FB + fa/Fa Mu .... Actual Mn * Phi ..... Allowable Shear Force @ this height Shear ..... Actual Shear ..... Allowable @ Top Support Stem OK 10.00 ft = # 5 16.00 in Center 4.00 in 0.000 0.0 ft-# 3,945.8 ft-# 2,919.0 lbs 60.81 psi 82.16 psi Other Acceptable Sizes & Spacings: Mmax Between Top & Base Stem OK 5.22 ft # 5 6.00 in Center 4.00 in 0.939 8,886.6 ft-# 9,459.0 ft-# = = = = = = ..1 o T 0.0 lbs 0.00 ft 0.00 in 0.00 ft Line Load 0.0 ft 0.300 0.0 psf 0.0 psf ~ • I @Base of Wall Stem OK 0.00 ft # 5 16.00 in Center 4.00 in 0.000 0.0 ft-# 3,945.8 ft-# 3,864.4 lbs 80.51 psi 82.16 psi Toe:# 5@ 18.00 in -or-Not req'd: Mu < phi*5*1ambda*sqrt(fc)*Sm Load Factors Building Code Dead Load Live Load Earth,H Wind,W Seismic, E IBC 2018,ACI 1.200 1.600 1.600 1.000 1.000 Heel:# 5@ 12.00 in -or-Not req'd: Mu < phi*5*1ambda*sqrt(fc)*Sm Key: #4@ 9.51 in, #5@ 14. -or-#4@ 9.51 in, #5@ 14.60 in, #6@ 20.6 NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~:m. Detail 2/ S30 Dsgnr: Project Designer ... Description .... Beacon, Restraint, 10-ft, 2/S30 Page : 2 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License: KW-06011040 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Development Center Concrete Stem Rebar Area Details Top Support As (based on applied moment) : (4/3) * As : 200bd/fy : 200( 12)( 4 )/60000 : 0.0018bh : 0.0018(12)(8) : Required Area : Provided Area : Maximum Area : Mmax Between Ends As (based on applied moment) : (4/3) * As : 200bd/fy : 200(12)(4)/60000 : 0.0018bh : 0.0018(12)(8) : Required Area : Provided Area : Maximum Area : Base Support As (based on applied moment) : (4/3) * As : 200bd/fy : 200(12)(4)/60000 : 0.0018bh : 0.0018(12)(8) : Required Area : Provided Area : Maximum Area : Vertical Reinforcing O in2/ft O in2/ft 0.16 in2/ft 0.1728 in2/ft 0.1728 in2/ft 0.2325 in2/ft 0.6503 in2/ft Vertical Reinforcing 0.5364 in2/ft 0. 7153 in2/ft 0.16 in2/ft 0.1728 in2/ft 0.5364 in2/ft 0.62 in2/ft 0.6503 in2/ft Vertical Reinforcing O in2/ft O in2/ft 0.16 in2/ft 0.1728 in2/ft 0.1728 in2/ft 0.2325 in2/ft 0.6503 in2/ft Horizontal Reinforcing Min Stem T&S Reinf Area 1.920 in2 Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of : #4@ 12.50 in #4@ 25.00 in #5@ 19.38 in #5@ 38.75 in #6@ 27.50 in #6@ 55.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 0.918 in2 Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of : #4@ 12.50 in #4@ 25.00 in #5@ 19.38 in #5@ 38.75 in #6@ 27.50 in #6@ 55.00 in Horizontal Reinforcing Min Stem T&S Reinf Area 1.002 in2 Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of : #4@ 12.50 in #4@ 25.00 in #5@ 19.38 in #5@ 38.75 in #6@ 27.50 in #6@ 55.00 in f Footing Strengths & Dimensions I l Footin~ Desiin Resu~ 1 eel Toe Width Heel Width Total Footing Widtt = Footing Thickness = Key W idth Key Depth Key Distance from Toe 0.67 ft 1.33 -2-.00 15.00 in 12.00 in 24.00 in 0.67 ft fc = 3,000 psi Fy = 60,000 psi Footing Concrete Density 150.00 pcf Min. As % 0.0018 Cover@ Top = 2.00 in @ Btm.= 3.00 in Toe Factored Pressure = 0 0 psf Mu': Upward = 0 0 ft-# Mu' : Downward 0 0 ft-# Mu: Design = 0 0 ft-# Actual 1-Way Shear 0.00 0.00 psi Allow 1-Way Shear 82.16 82.16 psi Min footing T&S reinf Area 0.65 in2 Min footing T&S reinf Area per foot 0.32 in2 !ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 7.41 in #4@ 14.81 in #5@ 11.48 in #5@ 22.96 in #6@ 16.30 in #6@ 32.59 in NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beacpn, Detail 2/ S30 Dsgnr: Project Designer ... Description .... Beacon, Restraint, 10-ft, 2/S30 Page : 3 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Restrained Retaining Wall Code: IBC 2018,ACI 318-1 4,TMS 402-16 [ Summary of Forces on Footing : Slab is NOT resisting sliding, stem is PINNED at footing Forces acting on footing for overturning, sliding, & soil pressure Lateral Distance Moment Overturning Moments ... lbs ft ft-# Stem Shear @ Top of Footing = -2,599.0 Heel Active Pressure = -824.1 Sliding Force = 3,423.1 1.25 0.61 -3,248.7 -505.3 Overturning Moment = Footing Overturning Stability Ratio -3,754.1 0.81 Net Moment Used For Soil Pressure Calculations Net Mom. at Stem/Ftg Interface = Allow. Mom. @ Stem/Ftg Interface = Allow. Mom. Exceeds Applied Mom.? Therefore Uniform Soil Pressure = 2,037.0 ft-# 2,037 .0 ft-# 2,466.1 ft-# Yes 1,364.3 psf Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Resisting Moments ... Surcharge Over Heel Adjacent Footing Load Axial Dead Load on Stem = Soil Over Toe Stem Weight Surcharge Over Toe Soil Over Heel Footing Weight Total Vertical Force Vertical Lateral lbs lbs 26.5 147.4 1,150.0 729.7 675.0 Distance ft 1.67 0.34 1.00 1.67 0.85 2,728.6 lbs Resisting Moment I Moment ft-# 44.3 49.4 1,153.8 1,217.3 576.5 3,041 .3 NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~m. Detail 2/ S30 Dsgnr: Project Designer ... Description .... Beacon, Restraint, 10-ft, 2/S30 Page : 4 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License: KW-06011040 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Development Center Rebar Lap & Embedment Lengths Information Stem Design Segment Near Top Support Stem Design Height: 10.00 ft above top of footing Lap Splice length for #5 bar specified in this stem design segment = Lap Splice length for #5 bar extending up into this stem design segment from below = Development length for #5 bar specified in this stem design segment= Development length for #5 bar extending up into this stem design segment from below= Stem Design Segment at Mmax Between Ends Stem Design Height: 5.22 ft above top of footing Lap Splice length for #5 bar extending down into this stem design segment from above = Lap Splice length for #5 bar specified in this stem design segment = Lap Splice length for #5 bar extending up into this stem design segment from below= Development length for #5 bar extending down into this stem design segment from above = Development length for #5 bar specified in this stem design segment = Development length for #5 bar extending up into this stem design segment from below= Stem Design Segment at Base Support Stem Design Height: 0.00 ft above top of footing Lap Splice length for #5 bar extending down into this stem design segment from above = Lap Splice length for #5 bar specified in this stem design segment= Development length for #5 bar extending down into this stem design segment from above = Development length for #5 bar specified in this stem design segment= Hooked embedment length into footing for #5 bar specified in this stem design segment = As Provided = As Required = 21 .36 in 21 .36 in 16.43 in 16.43 in 21.36 in 21 .36 in 21 .36 in 16.43 in 16.43 in 16.43 in 21 .36 in 21.36 in 16.43 in 16.43 in 9.59 in 0.2325 in2/ft 0.1728 in2/ft NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~n. Detail 21 530 Dsgnr: Project Designer ... Description .... Beacon, Restraint, 10-ft, 21530 Page : 5 Date: 7 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 8" Concrete w/#5@ ~;o Lateral Restraint t p t t t 10·-o· s· co1 ncrete w/ #5@ I(• >-,,.~~ 2'-D" '>.,y '>.,) ')o 8 C o 1crete w. r, 6" = #5@18." k ~J @Toe ~1l.7n 19~~r On Ke " ~ s· 1·-0·~ 8" 1'-4''. 2·-0· I 1'-6" 11'-6_ 10·-o· • •• 1 2" 1'-3" ~ T 3· Z-0" NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Pp= 4 781 .25# Project Name/Number : Title Beacpn, Detail 2/ S30 Dsgnr: Project Designer ... Description .... Beacon, Restraint, 10-ft, 2/S30 Page : 6 Date: 7 SEP 2018 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Lateral Restraint 2251.14# 1633 00psf (Serv1ce-Ievel)■ 40.00psf ill 5674# D Project Name/Number : NIC Consultants Title Beac~m. Detail 2/ 530 Page : 7 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package Dsgnr: Project Designer ... Description .... Date: 7 SEP 2018 Beacon, Restraint, 10-ft, 2/S30 This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Development Center asonry Designer to determine bar cutoff locations 390.0 lbs 1,170.0 lbs 1,9 0.0 lbs 2,7 0.0 lbs 3,5 0.0 lbs 1,5 0.0 lbs 2,3 0.0 lbs 3, 1 0.0 lbs I I • : t I • , --: .... __ _ ~ .... - 1 ! I I I·- ~ : I :~-- ~ ;-·----~--------~--------~11111111------~ ·----~~.--.. .... Project Name/Number : NIC Consultants Title Beac~n, Detail 2/ S30 Page : 8 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package Dsgnr: Project Designer ... Description .... Date: 7 SEP 2018 This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Beacon, Restraint, 10-ft, 2/S30 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 I • -. -• ' • -•. • . .... •• • •• I • -• :. - / •······· -, .... . I • I I · : I t · • , I I · • ,ti · , •II · : II · ••••• ••••• ••••• -.... ~-11 JI ~• ~·-..... -dlllll ••••• NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Bulld 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Criteria I Retained Height = 8.00 ft Wall height above soil 1.50 ft Total Wall Height 9.50 ft Top Support Height 8.00 ft Slope Behind Wal 0.00 Height of Soil over Toe = 6.00 in Project Name/Number : Title Beacpn, Detail 3/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric 8-ft, 3/S30 Page: 1 Date: 6 SEP 2018 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Soil Data I Allow Soil Bearing 3,000.0 psf Equivalent Fluid Pressure Method At-rest Heel Pressure = 60.0 psf/ft Passive Pressure Soil Density FootingJISoil Frictior Soil height to ignore for passive pressure 360.0 psf/ft 110.00 pcf 0.400 12.00 in Thumbnail s_u.rc•h•a•rg•e-l.oa•d•s---------■• Uniform lateral l oad Applied to Stem I iAd]acent Footi~ • Surcharge Over Heel 40.0 psf »>Used To Resist Sliding & Overturning Surcharge Over Toe 0.0 psf Used for Sliding & Overturning \ Axial load Applied to Stem Axial Dead Load Axial Live Load Axial Load Eccentricity = 0.0 lbs 0.0 lbs 0.0 in I Lateral Load ... Height to Top ... Height to Bottorr Load Type 1,633.0 #/ft 7.50 ft 6.50 ft = Seismic (E) (~trength Level) Wind on Exposed Stem = 0.0 psf Adjacent Footing Load Footing Width Eccentricity Wall to Fig CL Dist Footing Type Base Above/Below Soil at Back of Wall Poisson's Ratio 0.0 lbs 0.00 ft 0.00 in 0.00 ft Line Load 0.0 ft 0.300 EarthPressure Seismic load I Kh Soil Density Multiplier = ~~~~~~~~ 0.500 g Added seismic per unit area 0.0 psf .s.te•m-W•e•i•g•h•t .s.ei•s•m•i•c •l •o•a•d ____ J_■ Fp / WP Weight Multiplier = 0.000 g Added seismic per unit area 0.0 psf .o.e.s.ig11n_s.u.m_m•a•ry-■--------• Masonry Stem Construction I Total Bearing Load 3,638 lbs Thickness = 8.00 in rm = 1,500 psi 20,000 psi Short Term Factor = Equiv. Solid Thick.= n Ratio (Es/Em) 1.000 7.600in 21.481 ... resultant ecc. 6.04 in wall Weight = 78.0 psf Fs Soil Pressure @ Toe = 2.433 psf OK Soil Pressure @ Heel = 0 psf OK Allowable 3,000 psf Soil Pressure Less Than Allowable ACI Factored@ Toe = 2,920 psf ACI Factored @ Heel 0 psf Footing Shear@Toe = 0.0 psi OK Footing Shear@ Heel = 3.5 psi OK Allowable 82.2 psi Reaction at Top 2,155.1 lbs Reaction at Bottom = 2,103.2 lbs Sliding Stability Ratio = 1.65 OK Sliding Cales Lateral Sliding Force less 100% Passive Force= - less 100% Friction Force= - 2,103.2 lbs 2,025.0 lbs 1.455.1 lbs Added Force Req'd = ... .for 1.5 Stability = 0.0 lbs OK 0.0 lbs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing load Factors Building Code Dead Load Live l oad Earth,H Wind,W Seismic, E IBC 2018,ACI 1.200 1.600 1.600 1.000 1.000 Stem is FREE to rotate at top of footing Block Type = Medium Weight Design Method = ASD Solid Grouted Design Height Above Ftg Rebar Size Rebar Spacing Rebar Placed at Rebar Depth 'd' Design Data fb/FB + fa/Fa Moment. ... Actua Moment. .... Allowable Shear Force @ this height Anet Shear. .... Actual Shear ..... Allowable @ Top Support = Stem OK 8.00 ft # 5 8.00 in Edge 5.25 in 0.000 0.0 ft-# 3.403.2 ft-# 2,156.8 lbs 91 .50 in2 23.57 psi 77.71 psi Other Acceptable Sizes & Spacings: Mmax Between Top & Base Stem OK 4.21 ft # 5 8.00 in Edge 5.25 in 0.856 2,911.9 ft-# 3,403.2 ft-# @Base of Wall Stem OK 0.00 ft # 5 16.00 in Center 3.75 in 0.000 0.0ft-# 1,272.4 ft-# 1,571.4 lbs 91.50 in2 17.17 psi 77.71 psi Toe:# 5@ 18.00 in -or-Not req'd: Mu < phi•5•Iambda•sqrt(fc)•Sm Heel:# 5@ 12.00 in -or-Not req'd: Mu < phi•5•Iambda•sqrt(fc)*Sm Key: #4@ 9.51 in, #5@ 14. -or-#4@ 9.51 in, #5@ 14.60 in, #6@ 20.6 NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~>n, Detail 3/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric 8-ft, 3/S30 Page : 2 Date: 6 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Development Center fJooting Strengths & Dimensions Toe Width = 0.00 ft Heel Width 3.00 Total Footing Widt~ = 3.00 Footing Thickness Key Width Key Depth Key Distance from Toe fc = 3,000 psi Fy = Footing Concrete Density = Min.As% 12.00 in 12.00 in 24.00 in 2.00 ft 60,000 psi 150.00 pcf 0.0018 Cover @ Top = 2.00 in @ Btm.= 3.00 in • Footing Design Results I --••------To•e---•~eel Factored Pressure Mu': Upward Mu' : Downward Mu: Design Actual 1-Way Shear = Allow 1-Way Shear = 2,920 o psf 0 2,513 ft-# 0 4,063 ft-# 0 1,550 ft-# 0.00 3.49 psi 0.00 82.16 psi Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 1ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in ____ #6@ 4_0_.7_4_in ____ _ l Summa of Forces on Footin Slab is NOT resistin , stem is PINNED at footin Forces acting on footing for overturning, sliding, & soil pressure Lateral Distance Moment Vertical Lateral Overturning Moments... lbs ft ft-# Stem Shear@ Top of Footing = -1,571.4 1.00 -1 ,571.4 Heel Active Pressure = -531 .8 0.49 -260.9 ----- Sliding Force = 2,103.2 Overturning Moment = Footing Overturning Stability Ratio -1,832.3 2.98 Resisting Moments ... Surcharge Over Heel Adjacent Footing Load Axial Dead Load on Stem Soil Over Toe Stem Weight Surcharge Over Toe Soil Over Heel Footing Weight Total Vertical Force lbs lbs 93.3 = = = 741 .0 = 2,053.3 750.0 = 3,637.7 lbs Distance ft 1.83 0.33 1.83 1.70 Net Moment Used For Soil Pressure Calculations Net Mom. at Stem/Ftg Interface= Allow. Mom. @ Stem/Ftg Interface= Allow. Mom. Exceeds Applied Mom.? 1,830.8 ft-# 1,830.8 ft-# 1,272.4 ft-# No Resisting Moment = Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Moment ft-# 171.1 247.0 3,764.4 1,275.5 5,458.1 NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beacpn, Detail 3/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric 8-ft, 3/S30 Page : 3 Date: 6 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License: KW-06011040 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Development Center Rebar Lap & Embedment Lengths Information Stem Design Segment Near Top Support Stem Design Height: 8.00 ft above top of footing Calculated Rebar Stress,fs = 0.00 Lap Splice length for #5 bar specified in this stem design segment= Lap Splice length for #5 bar extending up into this stem design segment from below= Development length for #5 bar specified in this stem design segment= Development length for #5 bar extending up into this stem design segment from below= Stem Design Segment at Mmax Between Ends Stem Design Height: 4.21 ft above top of footing Calculated Rebar Stress,fs = 0.00 Lap Splice length for #5 bar extending down into this stem design segment from above= Lap Splice length for #5 bar specified in this stem design segment = Lap Splice length for #5 bar extending up into this stem design segment from below = Development length for #5 bar extending down into this stem design segment from above = Development length for #5 bar specified in this stem design segment = Development length for #5 bar extending up into this stem design segment from below = Stem Design Segment at Base Support Stem Design Height: 0.00 ft above top of footing Calculated Rebar Stress,fs = 0.00 Lap Splice length for #5 bar extending down into this stem design segment from above = Lap Splice length for #5 bar specified in this stem design segment= Development length for #5 bar extending down into this stem design segment from above = Development length for #5 bar specified in this stem design segment = Hooked embedment length into footing for #5 bar specified in this stem design segment = As Provided = As Required = 25.00 in 25.00 in 12.00 in 12.00 in 25.00 in 25.00 in 25.00 in 12.00 in 12.00 in 12.00 in 25.00 in 25.00 in 12.00 in 12.00 in 6.39 in 0.2325 in2/ft 0.1728 in2/ft NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~n. Detail 3/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric 8-ft, 3/S30 Page : 4 Date: 6 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Restrained Retaining Wall Code: IBC 201 8,ACI 318-14,TMS 402-1 6 Solid Grout a·Masonry w/ #5 ~~----------r----r- Lateral Restraint 8" M 8'-0" 8" M onry WI #5 9'-6" 1'-0" 2·-0· 2'-0" ·-o 3-o· 3'-0~ NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beaci:m, Detail 3/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric 8-ft, 3/S30 Page : 5 Date: 6 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Lat eral Restraint (s 1633r.09.eniiiii. ~§t1~1f ·1 • Pp= 2025.00# ...... (/"I 0. co 0 cvj (Y) ...,,. N 40.00psf ill 4258# NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Project Name/Number : Title Beac~n. Detail 3/ S30 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric 8-ft, 3/S30 Page : 6 Date: 6 SEP 2018 Restrained Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Designer to determine bar cutoff locations 240.0 lbs 720.0 lbs 1,2 0.0 lbs 1,6 0.0 lbs 2, 1 0.0 lbs 960.0 lbs 1,4 0.0 lbs 1,9 0.0 lbs NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beacpn, Detail 3/ 530 Dsgnr: Touraj Eimani Description .... Beacon, Eccentric 8-ft, 3/530 Page : 7 Date: 6 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Restrained Retaining Wall Code: IBC 2018,ACI 318-1 4,TMS 402-16 Base II · •11 " ·· • • . . • • . . ;e • . • • . 2,9 0.0 ft-# 1 ■■■11■■■ l J ~11111 ...... 111111111111 ■ -. dlllll I■■■■ 3,3 0.0 ft-# NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~n. Detail 4/ S30 Dsgnr: Touraj Eimani Description .... Beacon, 4ft, 4/S30 Page : 1 Date: 11 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License: KW-06011040 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Develo ment Center L Criteria [ Soil Data I Retained Height Wall height above soil Slope Behind Wall Height of Soil over Toe = Water height over heel 4.00 ft 1.50 ft 0.00 6.00 in 0.0 ft Allow Soil Bearing 3,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure 40.0 psf/ft Passive Pressure Soil Density, Heel Soil Density, Toe Footingl!Soil Friction Soil height to ignore for passive pressure 200.0 psf/ft 110.00 pcf 110.00 pcf = 0.300 = 18.00 in I L [surcharge Loads I ~teral Load Applied to Stem • I Adjacent Footing Load Surcharge Over Heel 40.0 psf Lateral Load 0.0 #/ft Used To Resist Sliding & Overturning ... Height to Top 0.00 ft Adjacent Footing Load Footing Width Surcharge Over Toe = 0.0 ... Height to Bottom = 0.00 ft Used for Sliding & Overturning Eccentricity Wall to Ftg CL Dist I Axial Load Applied to Stem • Axial Dead Load 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity 0.0 in I Earth Pressure Seismic Load ) Method : Inverted Triangular Load at top of Inverted Triangular Distribution .. (Strength) [ Design Summary Wall Stability Ratios Overturning Sliding Total Bearing Load ... resultant ecc. I 1.50 OK 1.64 OK 1,859 lbs 10.64 in Soil Pressure @ Toe 2,021 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 3,000 psf Soil Pressure Less Than Allowable ACI Factored@ Toe = 2,829 psf ACI Factored @ Heel O psf Footing Shear@ Toe Footing Shear@ Heel Allowable Sliding Cales Lateral Sliding Force = less 100% Passive Force = - less 100% Friction Force = - Added Force Req'd = .... for 1.5 Stability 16.9 psi OK 6.7 psi OK 82.2 psi 950.7 lbs 1,000.0 lbs 557.6 lbs 0.0 lbs OK 0.0 lbs OK Load Type Wind (W) (Service Level) Footing Type Base Above/Below Soil Wind on Exposed Stem = (Service Level) 0.0 psf at Back of Wall Poisson's Ratio Total Strength-Level Seismic Load .... . 216.000 psf Total Service-Level Seismic Load .. . L Stem Construction J Design Height Above Ftg ft= Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment....Actual Service Level Strength Level Moment. .... Allowable Shear ..... Actual Service Level Strength Level Shear ..... Allowable Anet (Masonry) Rebar Depth 'd' Masonry Data fm Fs lbs= lbs= ft-#= ft-#= psi = psi= psi = in2= in= psi= psi= Bottom Stem OK 0.00 Masonry ASD 8.00 # 5 16.00 Edge 0.807 896.6 1,402.4 1,810.2 3,689.7 2,243.7 9.8 18.9 45.1 91 .50 5.25 1,500 32,000 Yes ASD 139.50 Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Solid Grouting Modular Ratio 'n' Wall Weight psf= 12.89 84.0 Load Factors Building Code Dead Load Live Load Earth,H Wind,W Seismic, E IBC 2018,ACI 1.200 1.600 1.600 1.000 1.000 Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy = 1.000 in= 7.60 = Normal Weight = ASD psi= psi = = = = j 0.0 lbs 0.00 ft 0.00 in 0.00 ft Line Load 0.0 ft 0.300 540.000 lbs 378.000 lbs • Project Name/Number : NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package Title Beac~n, Detail 4/ S30 Dsgnr: Touraj Eimani Description .... Page : 2 Date: 11 SEP 2018 Beacon, 4ft, 4/S30 This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Develo ment Center Footing Dimensions & Strengths Toe Width Heel Width Total Footing Width Footing Thickness Key Width Key Depth Key Distance from Toe 1.29 ft = 1.71 = --3.00 12.00 in 15.00 in 24.00 in 1.25 ft fc = 3,000 psi Fy = 60,000 psi 150.00 pcf Footing Concrete Density Min. As % Cover@Top 2.00 = 0.0018 @ Btm.= 3.00 in I Footing Design Results • Factored Pressure Mu': Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe Reinforcing Heel Reinforcing Key Reinforcing Toe Heel 2,829 0 psf 1,804 0 ft-# 258 554 ft-# 1,546 554 ft-# 16.87 6.71 psi 43.82 43.82 psi #5@12.00in #5@14.00 in #5@8.00 in Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi•5•Iambda•sqrt(fc)•sm Heel: Not req'd: Mu < phi•5•Iambda•sqrt(fc)*Sm Key: Not req'd: Mu < phi•5•Iambda•sqrt(fc)*Sm Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@20.37 in 0.78 in2 0.26 in2 !ft If two layers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@40.74 in Summa of Overturnin & Resistin Forces & Moments ..... OVERTURNING ..... Force Distance Moment .. ... RESISTING ..... Force Distance lbs ft Moment ft-# Item lbs ft ft-# ----~---- Heel Active Pressure Surcharge over Heel Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil = Seismic Earth Load Total Resisting/Overturning Ratio 500.0 72.7 378.0 950.7 Vertical Loads used for Soil Pressure = 1.67 2.50 3.33 O.T.M. 833.3 181.8 1,260.0 2,275.2 1.50 1,858.8 lbs Soil Over Heel Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe Surcharge Over Toe Stem Weight(s) = Earth @ Stem Transitions= Footing Weight = Key Weight = Vert. Component 459.1 2.48 1,1 37.7 41 .7 2.48 103.4 71.0 0.65 45.8 462.0 1.62 750.0 450.0 1.50 675.0 375.0 1.88 703.1 3.00 ---Total= 1,858.8 lbs R.M.= 3,415.0 If seismic is included, the OTM and sliding ratios be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. [Tilt J • Axial live load NOT included in total displayed! or used for overturning resistance, but is included for soil pressure ca culation. Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus Horizontal Defl @ Top of Wall (approximate only) 250.0 pci 0.103 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Project Name/Number : NIC Consultants Title Beac~m. Detail 4/ S30 Page : 3 Date: 11 SEP 2018 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Dsgnr: Touraj Eimani Description .... Beacon, 4ft, 4/S30 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Calculated Rebar Stress,fs = 19517.30 Lap Splice length for #5 bar specified in this stem design segment= Development length for #5 bar specified in this stem design segment = Hooked embedment length into footing for #5 bar specified in this stem design segment = As Provided = As Required = Code: IBC 2018,ACI 318-14,TMS 402-16 25.00 in 24.40 in 6.03 in 0.2325 in2/ft 0.1462 in2/ft NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~n, Detail 4/ S30 Dsgnr: Touraj Eimani Description .... Beacon, 4ft, 4/S30 Page : 4 Date: 11 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License: KW-06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-1 6 8" w/ #5@ 16" Solid Grout #5@ ·12.in @ Toe #5@,8.in @ Center On Key #5@14" @Heel 5'-6" 2'-0" 1'-3" 1'-3" 6" 1'-3" 1'-9" 3'-0" NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Pp= 1000.00# Project Name/Number : Title Beac~m. Detail 4/ S30 Page : 5 Date: 11 SEP 2018 Dsgnr: Touraj Eimani Description .... Beacon, 4ft, 4/S30 Cantilevered Retaining Wall ..... (J) r 0.. ro (.!) 40 .00psf ill Code: IBC 2018,ACI 318-1 4,TMS 402-16 573# 378# ci N 0 N ■ Seismic lateral earth pressu NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Masonry 100.0 lbs 0.0 lbs 200.0 lbs Project Name/Number : Title Beacpn, Detail 4/ 530 Dsgnr: Touraj Eimani Description .... Beacon, 4ft, 4/530 Page : 6 Date: 11 SEP 2018 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Designer to determine bar cutoff locations 300.0 lbs 500.0 lbs 700.0 lbs 900.0 lbs 400.0 lbs 600.0 lbs 800.0 lbs NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Wall Masonry 250.0 ft-# 0.0 ft-# 500.0 ft-# Project Name/Number : Title Beac~n. Detail 4/ S30 Dsgnr: Touraj Eimani Description .... Beacon, 4ft, 4/S30 Page : 7 Date: 11 SEP 2018 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Allowable Moment Line Concrete Masonry Designer to determine bar cutoff locations 750.0 ft-# 1,2 0.0 ft-# 1,7 0.0 ft-# 2,2 0.0 ft-# 1,0 0.0 ft-# 1,5 0.0 ft-# 2,0 0.0 ft-# Project Name/Number : NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package Title Beac~m. Detail 5/ S30 Dsgnr: Touraj Eimani Description .... Page : 1 Date: 11 SEP 2018 Beacon, 5ft, 5/S30 This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 License To : RetainPro Develo Criteria Retained Height = 5.00 ft Wall height above soil = 1.50 ft Slope Behind Wall 4.00 Height of Soil over Toe = 0.00 in Water height over heel = 0.0 ft [ Surcharge Loads--~ • Surcharge Over Heel 40.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem ::) Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in l Earth Pressure Seismicload I Method : Inverted Triangular I Soil Data f Allow Soil Bearing = 3,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure 40.0 psf/ft Passive Pressure Soil Density, Heel Soil Density, Toe FootingjjSoil Friction Soil height to ignore for passive pressure 200.0 psf/ft 11 o.oo pcf 110.00 pcf 0.300 = 18.00 in .... L .L.a.te.r.a.1.Lo•a•d-A1111p1111p.li•e•d•t•o•S•t•e•m-_.l Adjacent Footing Load Lateral Load ... Height to Top ... Height to Bottom Load Type 0.0 #/ft 0.00 ft 0.00 ft = Wind (W) (Service Level) Wind on Exposed Stem = (Service Level) 0.0 psf Adjacent Footing Load Footing Width = Eccentricity Wall to Ftg CL Dist Footing Type Base Above/Below Soil at Back of Wall Poisson's Ratio = Total Strength-Level Seismic Load. . . . . = Load at top of Inverted Triangular Distribution . . . . . . = 216.000 psf Total Service-Level Seismic Load ..... (Strength) ,-- Design Summary I Stem Construction Wall Stability Ratios Overturning 1.13 Ratio < 1.5! Slab Resists All Sliding ! Total Bearing Load 1,942 lbs ... resultant ecc. = 21 .02 in Resultant Exceeds Fig. Width! Soil Pressure @ Toe O psf OK Soil Pressure @ Heel O psf OK Allowable 3,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe O psf ACI Factored @ Heel O psf Footing Shear@ Toe Footing Shear @ Heel Allowable Sliding Cales Lateral Sliding Force 1.9psi OK 10.5 psi OK 82.2 psi 1.432.3 lbs Notes: The ratio of overturning is below 1.5, but we add seismic load in our design, so the ratio above 1.1 is ok. Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force@ Section Service Level Strength Level Moment....Actual Service Level Strength Level Moment ..... Allowable Shear ..... Actual Service Level Strength Level Shear ..... Allowable Anet (Masonry) Rebar Depth 'd' ._ _________________ ... masonry Data Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code Dead Load Live Load Earth,H Wind,W Seismic, E IBC 2018,ACI 1.200 1.600 1.600 1.000 1.000 fm Fs Solid Grouting Modular Ratio 'n' Wall Weight Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data f c Fy I ft= Bottom Stem OK 0.00 Masonry ASD 8.00 # 6 8.00 Edge 0.925 lbs = 1,220.7 lbs= 1,402.4 ft-#= 2,995.2 ft-#= 3,689.7 = 3,237.7 psi= 13.3 psi= 18.9 psi= 45.4 in2 = 91 .50 in = 5.25 psi= 1,500 psi= 32,000 = Yes 12.89 psf= 84.0 = 1.000 in = 7.60 = Normal Weight ASD psi = psi = ASD 139.50 0.0 lbs 0.00 ft 0.00 in 0.00 ft Line Load 0.0 ft 0.300 675.000 lbs 472.500 lbs • NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beacpn, Detail 5/ S30 Dsgnr: Touraj Eimani Description .... Beacon, 5ft, 5/S30 Page: 2 Date: 11 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 Cantilevered Retaining Wall License To : RetainPro Develo ment Center Code: IBC 2018,ACI 318-14,TMS 402-16 Footing Dimensions & Strengths I Footing Design Results Toe Width Heel Width Total Footing Width Footing Thickness Key Width Key Depth = Key Distance from Toe 1.29 ft 1.96 ~5 15.00 in 0.00 in 24.00 in 1.25 ft fc = 3,000 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover@ Top 2.00 @ Btm.= 3.00 in Toe Heel Factored Pressure = O O psf Mu' : Upward = O O ft-# Mu' : Downward 237 1,524 ft-# Mu: Design = -237 1,524 ft-# Actual 1-Way Shear 1.87 10.51 psi Allow 1-Way Shear = 43.82 43.82 psi Toe Reinforcing = # 5@ 12.00 in Heel Reinforcing = # 5@ 14.00 in Key Reinforcing # 5 @ 8.00 in Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm Heel: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm Key: Slab Resists Sliding -No Force on Key Min footing T&S reinf Area 1.05 in2 0.32 in2 1ft Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 7.41 in #5@ 11.48 in #6@ 16.30 in If two layers of horizontal bars: #4@ 14.81 in #5@22.96 in #6@ 32.59 in Summary of Overturning & Resisting Forces & Moments ..... OVERTURNING ..... . .... RESISTING ..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure Surcharge over Heel Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load Load @ Stem Above Soil = Seismic Earth Load = Total Resisting/Overturning Ratio 864.2 95.6 472.5 1,432.3 2.19 3.29 4.17 O.T.M. 1,893.5 314.2 1,968.8 4,176.5 Soil Over Heel = Sloped Soil Over Heel Surcharge Over Heel Adjacent Footing Load = Axial Dead Load on Stem= • Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = Earth @ Stem Transitions= 71 1.3 23.0 51 .7 546.0 610.0 2.61 2.82 2.61 1.63 1.63 Footing Weight Key Weight = 1.25 1,854.2 64.9 134.9 888.2 992.3 Vertical Loads used for Soil Pressure = = 1.13 1,942.1 lbs Vert. Component = 240.6 3.25 782.6 Total = 2,182.6 lbs R.M.= 4,717.0 If seismic is included, the OTM and sliding ratios be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 • Axial live load NOT included in total displayed! or used for overturning resistance, but is included for soil pressure ca culation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt -, Notes: The ratio of overturning is below 1.5, but we add seismic load in our design, so the ratio above 1.1 is ok. Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus Horizontal Defl @ Top of Wall (approximate only) 250.0 pci 0.103 in The above calculation Is not valid 1f the heel s01I bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil • Project Name/Number : NIC Consultants Title Beac~>n, Detail 5/ S30 Page : 3 Date: 11 SEP 2018 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Dsgnr: Touraj Eimani Description .... Beacon, 5ft, 5/S30 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Rebar Lap & Embedment Lengths Information Stem Design Segment: Bottom Stem Design Height: 0.00 ft above top of footing Calculated Rebar Stress,fs = 11977.37 Lap Splice length for #6 bar specified in this stem design segment = Development length for #6 bar specified in this stem design segment= Hooked embedment length into footing for #6 bar specified in this stem design segment = As Provided = As Required = Code: IBC 2018,ACI 318-14,TMS 402-16 30.00 in 17.97 in 6.00 in 0.6600 in2/ft 0.2449 in2/ft NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beac~>n, Detail 5/ S30 Dsgnr: Touraj Eimani Description .... Beacon, 5ft, 5/S30 Page : 4 Date: 11 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 8" w/ #6@ 8" Solid Grout #5@12.in @ T oe #5@14" @Heel Restraint ----- 1'-3" Z-0" 1'-4" Z-0" 3'-3" 4 ,5'-4" : i : ! ! : Z-0" 6'-6" 5'-0" NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Restraint Project Name/Number : Title Beac~n. Detail 5/ 530 Dsgnr: Touraj Eimani Description .... Beacon, 5ft, 5/530 Page : 5 Date: 11 SEP 2018 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 40 00psf ill 4 960# 473# ■ Seismic lat eral earth pressure NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Masonry 140.0 lbs 0.0 lbs 280.0 lbs Project Name/Number : Title Beacpn, Detail 5/ S30 Dsgnr: Touraj Eimani Description .... Beacon, 5ft, 5/S30 Page : 6 Date: 11 SEP 2018 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Designer to determine bar cutoff locations 420.0 lbs 700.0 lbs 980.0 lbs 560.0 lbs 840.0 lbs 1,2 0.0 lbs 1,120.0 lbs NIC Consultants 23 Corporate Plaza Drive Newport Beach, CA 92660 Beacon Site Package This Wall in File: Project Name/Number : Title Beacpn, Detail 5/ S30 Dsgnr: Touraj Eimani Description .... Beacon, 5ft, 5/S30 Page : 7 Date: 11 SEP 2018 Enercalc EARTH (c) 1987-2018, Build 11.18.09.29 License : KW-06011040 License To : RetainPro Development Center Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16 Masonry Allowable Moment Line Masonry Designer to determine bar cutoff locations 360.0 ft-# 1,0 0.0 ft-# 1,8 0.0 ft-# 2,5 0.0 ft-# 3,2 0.0 ft-# 720.0 ft-# 1,4 0.0 ft-# 2, 1 0.0 ft-# 2,8 0.0 ft-#