Loading...
HomeMy WebLinkAboutCDP 00-65; Clements Residence; Preliminary Investigation - 5021 Tierra Del Sol; 2001-03-07Efifjificcriiiij, Inc. CIVIL. GEOTECHNICAL. <S QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENT* INSPECTION CLIENT: SOTO PROJECT: SOT 201 A DATE: 7 MAR. 2001 MR. WILLIAM CLEMENTS C/O S & S GENERAL CONTRACTOR 1611-AS. Melrose Drive Vista, CA. 92083 Attention: Mr. Robert Soto Subject: Preliminary Geotechnical Soil Investigation for the Proposed Residential Construction for the Lot located at 5021 Tierra Del Sol, Carlsbad, CA. (APN: 210-020-13) Gentlemen: Pursuant to your request, we have completed our Preliminary Soils Investigation for the subject site. The purpose of the Investigation was to determine the general engineering characteristics of the soils on and underlying the site and to provide specific recommendations for the design parameters for foundations and retaining structures, slab-on-grade floors and site earthwork. The proposed development consists of the construction of a second story addition to an existing single story residential structure. SITE CONDITIONS The subject site consists of a rectangular shaped lot located approximately 0.5 mile west of the 1-5 Freeway on the westerly side of Tierra Del Sol Street in the City of Carlsbad. The property is bounded on the east by Tierra Del Sol Street, on the north and south by existing single family residences, on the west by the Pacific Ocean. The site topography consists of a level pad on the easterly side of the lot with an existing single structure. On the westerly portion of the lot there is an existing terraced slope at an approximate inclination of 1.5 : 1 horizontal to vertical. At the time of this investigation, the slope was covered with ice plant and some low lying shrubs. Along the toe of the westerly facing slope as well as along the toe of the adjacent slopes extending to the north and south of the subject site is an existing 1 1611-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 Ifrii/ifiecrififj, Inc. CIVIL, GEOTECHNICAL. t QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENT i INSPECTION erosion control device consisting of large boulders stacked at approximately 30 feet wide by 10 feet high. The purpose of this jetty is for the protection of the westerly facing slopes on this lot and adjacent properties against erosion caused by ocean wave action. FIELD AND LABORATORY TESTING On 15 February 2001, a Field Investigation was performed at the subject site. This investigation consisted of the excavation of two test pits dug with a hand drill auger. Locations of these test holes are shown on the Plot Plan, Enclosure (1) and the detailed Logs of these Test Pits are presented on Enclosure (2). As the test pits were advanced, the soils were visually classified by the Field Engineer. Undisturbed and bulk samples, as well as in-place density tests, were obtained at various depths representative of the different soils horizons. All samples were returned to our laboratory for detailed testing. Results of the in-place compaction tests, the Maximum Dry Density Test values for the various soils sampled and the Expansion Potential Test results are presented on Enclosure (3). These materials were also tested for Shearing Strength, Enclosure (4). Shear tests were made with a direct shear machine of the strain control type in which the rate of strain is 0.05 inches perminute. The machine is so designed that tests may be performed ensuring a minimum of disturbance from the field conditions. Saturated, remolded specimens were subjected to shear under various normal loads. Expansion tests were performed on typical specimens of natural soils. These tests were performed in accordance with the procedures outlined in the Uniform Building Code. SOIL CONDITIONS As indicated by our Test Pit Logs, Enclosure (2), the westerly side of the house pad is underlain with approximately 4 feet of fill materials consisting of dry to damp, loose to dense, brown silty sands. Underlying the fill materials and exposed on the westerly slope face are Terrace Deposit materials consisting of damp, moderately well cemented, massively bedded, silty fine to medium sands. 2 7671-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 , Inc. CIVIL. GEOTECHNICAL. t QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENT t INSPECTION GEOLOGIC HAZARDS According to published information, there are no known active or potentially active faults on or in the immediate vicinity of the subject site. Therefore, the potential for ground rupture at this site is considered low. There are, however, several faults located within a close proximity to this site that the movement associated with them could cause significant ground motion. The following table presents the distance of major faults from the site, the assumed maximum credible earthquake magnitudes and estimated peak accelerations anticipated at the site. The probability of such an earthquake occurring during the lifetime of this project is considered low. The severity of ground motion is not anticipated to be any greater at this site than in other areas of San Diego County. SEISMICITY OF MAJOR FAULTS MAXIMUM CREDIBLE ESTIMATED FAULT DISTANCE MAGNITUDE(RICHTER) ACCELERATION(g) Rose Canyon 4 mi. 7.0 0.25 Elsinore 29 mi. 7.5 0.35 SanJacinto 52 mi. 7.8 0.17 San Andreas 76 mi. 8.3 0.12 The following information is presented relative to the subject site and Seismic Zone 4 per the U.B.C.: SEISMIC PROFILE UBC TABLE (z) Seismic zone factor = 0.4 16 A-I (Na) Near-source factor = 1.0 16A-S (A) Seismic source type = A 16A-U (Sd) Soil profile type = Sd 16A-J (Ca) Seismic coefficient = 0.44 Na 16A-Q (Cv) Seismic coefficient = 0.64 Nv 16A-R (Nv) Near-source factor =1.2 16 A-T 3 1611-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 m/, flic. CIVIL. GEOTECHNICAL. t QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENT* INSPECTION LIQUEFACTION POTENTIAL Liquefaction analysis of the soils underlying the site was based on the consideration of various factors which include the water level, soil type gradation, relative density, intensity of ground shaking and duration of shaking. Liquefaction potential has been found to be the greatest where the ground water level is shallow and loose fine sands occur within a depth of 50 feet or less. These conditions are not present within the site area and, therefore, the potential for generalized liquefaction in the event of a strong to moderate earthquake on nearby faults is considered to be low. STABILITY The relatively dense nature of the slopes within the site and the nature of the material underlying the site generally preclude the occurrence of major landslide conditions. The area surrounding the site is not known to be within an area of ground subsidence. The potential for deep seated slope failure at the subject site is considered low. The site surface materials consist of silty sands that are relatively dense in their dry state. These materials are susceptible to erosion. Drainage control is essential to maintain the stability of any planned slopes or slope areas. FLOODING Flooding is not expected to present a hazard to the existing or proposed development, assuming that structures are constructed above the design historical flood elevations. TSUNAMIS Tsunamis are large sea waves generated by a submarine earthquake or volcanic eruption. The highest waves historically to affect the San Diego coastal area has been slightly in excess of 6 feet. There is a possibility that the site could be subject to tsunami related hazards in an offshore seismic event. 4 1611-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 , Inc. CIVIL, GEOTECHNICAL, t QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENT t INSPECTION CONCLUSIONS AND RECOMMENDATIONS Based on field data and our laboratory tests results, the following Conclusions and Recommendations are presented and are to be utilized in conjunction with the Building Plans. Based on the present site conditions, it is concluded that the long term recession of the westerly slope has been significantly reduced by the installation of the sea-wall jetty. It is further concluded that if the sea-wall jetty is properly maintained throughout the life of the project, the residence should have a usable life span of at least 75 years. On the basis of our investigation, development of the site as proposed is considered feasible from a soils engineering standpoint provided that the recommendations stated herein are incorporated in the design of foundation systems and are implemented in the field. The main consideration in developing the subject site is the presence of loose to dense fill materials subject to possible creep. The thickness of these materials is approximately 2 to 4 feet below the existing surface. These materials are considered unsuitable in their present condition for the support of the proposed second story addition to the existing structure. In order to help mitigate this potentially adverse condition we recommend that the proposed foundation system shall be embedded into the underlying terrace deposit soils. Foundations shall be sized and constructed in accordance with the Structural Engineer's design, based on the earth pressures and the allowable bearing values listed below, along with the expected live and dead loads, and the projected wind and seismic loads. All structural fill shall be compacted to at least 90% of the maximum dry density at near optimum moisture content as determined in accordance with ASTM Test Procedure D 1557-91 or equivalent. Site drainage should be dispersed by non-erodible devices in a manner to preclude concentrated runoff over graded and natural areas in accordance with the City of Carlsbad requirements. 5 1611-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 ffrif/fficcrffiif, fiie. CIVIL, GEOTECHNICAL. t QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENT t INSPECTION FOUNDATIONS For foundation design purposes, the following earth pressures were calculated based on our Shear Test Results (Enclosure 4) and based on a foundation depth and width of 12 inches: Shear Test: Cohesion =180 psf; Angle of Friction = 35° . Allowable Bearing Value = 2050 psf Equivalent Fluid Pressure = 35 psf Passive Lateral Resistance = 475 psf Active Pressure = 35 psf Coefficient of Friction = 0.35 Expansion Index = 0 (NON EXPANSIVE) These values are for dead plus live loads and may be increased by one-third (1/3) for seismic and wind loads where allowed by code. These design bearing values are in accordance with the Uniform Building Code and were calculated based on Terzaghis1 Formula. It is recommended that the continuous perimeter foundations and concrete slabs for a light weight wood-framed structure shall be reinforced in accordance with the following minimum designs: a. Foundation dimensions: it is recommended that the continuous perimeter foundations for support of the proposed two story structure shall extend to a minimum depth of 24 inches and a minimum width of 18 inches into the firm native terrace deposit soils. Due to the thickness of the upper fill soils, it anticipated that the depth of proposed footings may be 6 foot below the existing surface. Footings placed adjacent to the existing house foundations shall be doweled with No. 4 bars at 12 inches on center with an minimum embedment of 6 inches into both footings. b. All perimeter foundations shall be reinforced with at least four No.4 steel bars horizontally, two bars shall be placed 3 inches from the top of the foundation and the other bars shall be placed 3 inches from the bottom. Interim horizontal steel bars, ie: two No. 4 steel rebars, shall be placed at 12 inches on center vertically in the deepened foundations. 6 1611-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 iiiff, Inc. CIVIL. GEOTECHNICAL. t QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENT 4 INSPECTION c. All interior concrete slabs shall be a minimum of four inches in thickness and reinforced with a minimum of No. 3 rebar at 24 inches on center both ways placed in the center of the slab. The slab steel reinforcement shall be bent downward into the perimeter footings and connected to the foundation steel at 24 inches on center. In order to minimize vapor transmission, an impermeable membrane (ie: 10 mil visqueen) shall be placed over 2 inches of clean, poorly graded, coarse sand, decomposed granite, or crushed rock. The membrane shall be covered with 2 inches of sand to protect it during construction and the sand should be lightly moistened just prior to placing concrete. All concrete used on this project shall have a minimum compressive strength of 2500 psi unless otherwise stated on the Building Plans. If imported soil materials are used during grading to bring the building pad to the design elevations, or if variations of soils or building locations are encountered, foundation and slab designs shall be reevaluated by our firm upon the completion of foundation excavations. Footings located on or adjacent to the top of slopes shall be extended to a sufficient depth to provide a minimum horizontal distance of 7 feet between the bottom edge of the footing and the face of the slope. These foundation recommendations are minimum design requirements for the soils encountered during this investigation; however, actual foundations shall be designed by the Structural Engineer for the expected live and dead loads, and for wind and seismic loads. Findings of this Report are valid as of this date; however, changes in conditions of a property can occur with passage of time, whether they be due to natural process or works of man on this or adjacent properties. In addition, changes in applicable or appropriate standards occur whether they result from legislation or broadening of knowledge. Accordingly, findings of this Report may be invalidated wholly or partially by changes outside our control. Therefore, this Report is subject to review and should not be relied upon after a period of one year. In the event that any changes in the nature, design, or location of buildings are planned, the conclusions and recommendations contained in this Report shall not be considered valid unless the changes are reviewed and the conclusions of this Report are modified or verified in writing. 7 7671-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 ffrii/jiiecrifif/, Inc. CIVIL. GEOTECHNICAL. i QUALITY ENGINEERING FOUNDATION DESIGN • LAND SURVEYING • SOIL TESTING CONSTRUCTION MANAGEMENTS INSPECTION This Report is issued with the understanding that it is the responsibility of the owner or of his representative to ensure that the information and recommendations contained herein are called to the attention of the project Architect and Engineer and are incorporated into the plans. Further, the necessary steps shall be taken to ensure that the contractor and subcontractors carry out such recommendations in the field. It is recommended that the Soil Engineer be provided the opportunity for a general review of the final design plans and specifications for this project in order that the recommendations of this report may be properly interpreted and implemented in the design. It is also recommended that the Soil Engineer be provided the opportunity to verify the foundation and slab construction in the field prior to placing concrete. (If the Soil Engineer is not accorded the privilege of making these reviews, he can assume no responsibility for misinterpretation of his recommendations) . The Soil Engineer has prepared this Report for the exclusive use of the client and authorized agents. This Report has been prepared in accordance with generally accepted soil and foundation engineering practices. No other warranties, either expressed or implied, are made as to the professional advice provided under the terms of this agreement, and included in the Report. B & B Engineering Inc. and Associates appreciate this opportunity to be of service. Should you have any questions regarding this project, please do not hesitate to contact us. Sincerely, Arthur C. Beard RCE RGE Chief Engineer 7671-A SO. MELROSE DRIVE #285, VISTA, CA 92083-5497 • 760-945-3150 • FAX: 760-945-4221 APPROXIMATE LOCATION OF FIELD EXPLORATORY TEST PIT PLOT PLAN OWNER ;WILLIAM LOCAT I ON ; 5O 2 1 PEL PROJECT; 50T 2O)A DATE: Engineering, inc. CIVIL, GEOTECHNICAL. i QUALITY ENGINEERS STRUCTURAL ENGINEERING • LAND SURVEYING • PERCOLATION t SOIL TESTING • CONSTRUCTION MANAGEMENT & INSPECTION ENCLOSURE (1) Eiiffiiieeriiifi, inc. CIVIL, QEOTECHNICAL, t QUALITY ENGINEERS STRUCTURAL ENBINEERINO • LAND SURVEYING • PERCOLATION* SOIL TESTING • CONSTRUCTION MANAGEMENT & INSPECTION 20t A LOG OF TEST PITS EXCAVATED. PIT DIMENSIONS IN FEET W Baokhoe MA UP D P-l SURFACE ELEVATION IN FEET DATUM Mean Sea Level GEOLOGICAL CLASSIFICATION DESCRIPTION A^T/PIC/A^ FILL TE&tACE DEPOSITS *ELEVATIONIN FEETxg oz V4 5 10 IS SYMBOL iMWJt. *4n ^ ENGINEERING CLASSIFICATION AND DESCRIPTION 4" 9CC 5tA5 ^" 6fcES UG. 6A^e 4" blZ\CK. LAM6R- R.i'5/^\\/l i 1 C\iTCl ^Aklrt 1*^/^1OK-OWM OIL.IT OHrJu v >5'n J\ C^M»? , og-f^se TA oT^i T~< — —i <£. . \r\/-//v\iflt^J lOr^C/lW AJ ^ I L 1 ^f O»lN^ L' I O'iyv DA/^I^ DE/OSE. 6ecoMi/o^ \ MOK.£ DEP5B VA^T^ O&fTH\ boTTOf^ £>F TECT PiT" @ 5.5' TEST DATA PIT DIMENSIONS IN FEET W L SURFACE ELEVATION IN FEET FILL 10 IS \ \ 4" PCC 4" SttVi DAMP , TAN) - op PIT® 5 l\\i CLIENT: CLEMEOTS /SoTO Test No. / z 3 4 Test Date % '1 « II Test Location TP-I it TP-2 ,. Test El /Depth 2' *>' 2* 3' if&K Engineering, inc. CIVIL, QEOTECHNICAL, t QUALITY ENGINEERS • STRUCTURAL ENGINEERING • LAND SURVEYING • PERCOLATION S SOIL TESTING • CONSTRUCTION MANAGEMENT & INSPECTION PROJECT: SOT "2o\ A WTE: f\A£CM ZOo 1 Soil Type A n n a Dry Density, pcf Field II4& IIB.9 \M llll Maximum. W>0 II " ll Moisture. X Field £9 7>z £* 4.7 Opt. 10.Z .' II " Relative Compaction #9 9Z $d 91 Re test No. COMPACTION CURVE DATA SOIL TYPE AND DESCRIPTION OPTIMUM MAXIMUM DRY MOISTURE % DENSITY (pcf) A, 8l2/)lAJAJ 5ILTM vSAMO .10-5 /2J.O ExPAfJ-SlO^ ItJQE^ - (fi EXPANSION POTENTIAL St/our&ts/ws/i/e) i . TZ4T pZUSoHrtG.0 &VSO/L fMrt TP-I& 2,' 51 I 91 - 131 - - 20 » Very Low - 50 - Low • 90 » Moderate •130 - High •above=Critical EXPANSION AND COMPACTION TEST DATA NCLOSURE (3) 2000 1600 Oz UJ o: 1200 oz a: < 800UJ X (O 400 35' 400 800 1200 1600 NORMAL LOAD (PSR 2000 SOIL TYPE 5/Lfl S£/V>0 w> •o 3 remold |y: BORING NO. (BN) TP-1 DEPTH (ft) ^' MOISTURE (%) /!./% COHESION (PSF) ISO psf ANGLE OF FRICTION («) 3S° , Inc. CIVIL, QEOTECHNICAL, * QUALITY ENGINEERS • STRUCTURAL ENGINEERING 'LAND SURVEYING • PERCOLATION A SOIL TESTING • CONSTRUCTION MANAGEMENT A INSPECTION SOT 20/ A SHEARING STRENGTH TEST