Loading...
HomeMy WebLinkAboutCDP 2016-0004; 148 TAMARACK AVENUE; RESPONSE TO THIRD PARTY SECOND REVIEW DATED JUNE 19,2019; 2019-06-21. , .. \ . ~ June 21, 2019 1941-A Friendship Drive El Cajon, CA 9 2020 ff/, (M'J) 158-WJnO FAX(619) 258-9004 RECE'WED JUN 2 4 2019 Mr. Jeff Parshalle jeff@jparch.net LAND DEVELOPMENT Subject: Response to Third-Party Geotechnical Review (Second ~J~.ffiJ~~ 2019 for the Subject Property located at 148 Tamarack, Carlsbad, CA 92008 Dear Mr. Parshalle: In accordance with your request, we have provided this Second Addendum Geotechnical letter in response to the City Carlsbad, Third-Party Geotechnical Review (Second Review) dated June 19, 2019 by Herrington Engineering, Inc for the Subject Property located at 148 Tamarack, Carlsbad, CA 92008 The following are our responses to the Third-Party Geotechnical Review (Second Review): Issue #1 1. The Consultant should review the project foundation plans, provide any additional geotechnical recommendations considered necessary, and confirm that the plans have been prepared in accordance with the geotechnical recommendations provided in the referenced repmts. We have reviewed the structural and foundation plans prepared by Mike Suprenant and Associates dated August 11, 2017 (revised 6/4/19) for the new single family residence with detached garage for the aforementioned address. Specifically, we have reviewed sheets S-1, S-2, S-3, SD-1 and SD-6 of the structural plans. We certify that the plans have been prepared in accordance with the geotechnical recommendations provided in the referenced report for the subject property 148 Tamarack, Carlsbad, CA 92008. Issue #2 2. The existing site topography and existing improvements "Geologic/Geotechnical Map ... " provided in Reforence 5. provide a legible copy of the "Geologic/Geotechnical Map ... ". are not legible on the The Consultant should See attached Geologic/Geotechnical Map for the Subject Property Located at 148 Tamarack, Carlsbad, CA 92008 -A legible copy of the geologic/geotechnical map has been incorporated as part of this response letter. 148 Tamarack Ave-Third Party Geology review (2nd review) JLVG/BJL 6/21/2019 Page 1 of2 . " Issue #3 3. The Consultant should provide a complete I ist of recommended observation and testing during site grading and construction. The following list of observation and testing is recommended to be performed during grading and construction of the project: • Pre-grading inspection and pre-grading meeting with grading contractor to check that grading limits conform to those specified in the project plans. • Inspection of bottom of excavation key for the remedial removal and recompaction of the proposed building pads. • Continuous observation of site soil conditions to check that the subsurface conditions and soil properties conform to those specified in the approved geotechnical reports. • Continuous observation of engineered fill placement and compaction per Section IV of the General Earthwork and Grading Guidelines listed on the approved geotechnical report. Field density testing for compaction of the engineered fill shall be performed in accordance with ASTM D1556 or ASTM D6938 methods. • Inspection of bottom of footings trenches to be satisfactory to achieve the design bearing capacity. We appreciate this opportunity to be of service. Should you have any questions, please call our office at (619) 258-9000. Sincerely, ernard J. Luther, RCE 63653, CEG 1356 CEO C 63653 I \:!1c~1~r-~~ •, :.-- 148 Tamarack Ave -Third Party Geology review (2nd review) JLVG/BJL 6/21/2019 Page 2 of2 4• PVC OU71.ET 7HRU WALL TO CONCRETE DRIV£WA Y (.'.) /!:If.:~ /!:If.:~ 1!:I ... ~ ~~~ ~~~ r ....._, "' "' "' "' "' "' EXISTING BUILDING PERMEABLE PAV£RS PER ARCHITEcrs BUILDING PLAN~ 4" ATRIUM DRAIN ~1H, 4• PVC Rl.<iFR .C-4• PVr. I , ~ a . <o >-' (/) EXISTING OV£RHEA1~-~•--c,,. X: 7 B-2 TO 36• ;BELOW GROUND ,:SURFACE EXISTING MASONRY WALL TO REMAIN DRAIN , B-1 TO 54• a BELOW GROUND ,,') ELECTRIC LINE - PROTECT IN PLACE UNTIL REMOVED , ~ Q: . -~~ B OU71.ET 4 • PVC PIPE 1HRU CURB FACE -APPLIED CON§Y!J~ SURFACE :u.:>U ~~~ ®t~ f C I a t.~ 11 ~ L r J, ,.,r H , I 1JJ'~ MAIN BUILDl/'fG (4" CONC./4" AB) 54.80 FF 54.IJ PAD f 1 -o w~a • ~. ~l: ~=~~• ..--__,_q ~ I :t:(if\~) •. l((i6~) r-~ t=r~: r~ ! L 4 NJ4'JOVl"W 116.71' A...,.] EXISTING GAS UN[. _J 12+55 It ,.,,~'&! LCOBBLESTONE PROTECT IN PLACE 12+53 -EXIST WATER i:::: L<J ~ SH IN -CONGRE-Tf--UNn D 'O R/W I.I TER ~ co ~ '----EXISTING A · LEGEND: f;:j ~ ~ BUILDING REFERENCE: This map was ~~ 1 Qop6-7 -OLD PARALIC prepared from an existing STAT/ DEPOSITS, UNITS 6-7 Grading plan by bHa, Inc. and ~~; r --1 PROPERTY LINE from the field investigation LANDS, ---• performed by APPLIED CONSULT ANTS. FIFURE A: GEOLOGIC/ GEOTECHNICAL MAP 148 TAMARACK AVE, CARLSBAD, CALIFORNIA 92008 .----. ·----· LIMITS OF REMEDIAL GRADING Date : 6/3/19 Drawn by: J L VG ...