HomeMy WebLinkAboutCDP 2017-0044; THOMAS GEESBREGHT ADU; GRADING PLAN REVIEW; 2018-12-12COAST GEOTECHNICAL CONSULTING ENGINEERS AND GEOLOGISTS RECORD COPY Decem her 12, 2018 John and Priscilla Geesbreght 4056 Skyline Road Carlsbad, CA 92008 Subject: GRADING PLAN REVIEW Proposed Guest House 4056 Skyline Road Carlsbad, California References: SUPPLEMENTAL REPORT Proposed Guest House 4056 Skyline Road Carlsbad, California Prepared by Coast Geotechnical Dated January 8, 2018 RESPONSE TO CITY OF CARLSBAD SDRSD C-01 Retaining Wall Proposed Guest House 4056 Skyline Road Carlsbad, California Prepared by Coast Geotechnical July 2, 2018 Q;;(Lh,Nr-• Tnitial ECF.fVED JAN O 8 2019 LAND Ut:VELOPMENT ENGINEERING PRELIMINARY GEOTECHNICAL INVESTIGATION Proposed Guest House 4056 Skyline Road Carlsbad, California Prepared by Coast Geotechnical Dated July 26, 2018 Dear Mr. and Mrs. Geesbreght: -,./51., Date As requested, we have reviewed the project grading plan, Sheet 3 and sections and BMP Details Sheet 4, prepared by Civil Landworks, and observed that they have, in general, included the recommendations presented in our Preliminary Geotechnical Report. The following comments address the plans from a geotechnical viewpoint. P.O. BOX 230163 • ENCINITAS, CALIFORNIA 92023 • (858) 755-8622 Coast Geotechnical COMMENTS December 12, 2018 W.O. P-674617 Page 2 of 3 1) Cut/fill transitions in the building pad should be overexcavated a minimum of 3.0 feet and replaced as properly compacted fill as indicated on the plans and preliminary geotechnical report. However, remedial grading will be required as recommended in the Preliminary Geotechnical Report and indicated on the plans. Removals are anticipated to be on the order of 4.0 feet or 18 inches below the deepest footing, whichever is greater. However, deeper removals may be necessary. Additional recommendations will be necessary during the grading phase. All fill should be keyed and benched into competent Old Paralic Deposits. 2) All fills should be observed and tested by a representative of the Geo technical Engineer. All cut slopes and temporary slopes should be by an Engineering Geologist. Additional recommendations may be necessary during the grading/construction phases. 3) The proposed biofiltration basin should be sealed with an impervious liner as recommended and as shown on the Plans. LIMITATIONS The findings and opinions presented herein have been made in accordance with generally accepted professional principals in the fields of engineering geology and soils engineering. No warranty is expressed or implied. The geotechnical reports should be considered as part of these plans. Should any discrepancies between the geotechnical report(s) recommendations and the plans occur, the geotechnical report(s) shall take precedence unless otherwise advised by the geotechnical engineer. Coast Geotechnical December 12, 2018 W.O. P-674617 Page 3 of 3 If you have any questions regarding this report, please contact our office. Reference to our Job No. P-674617 will help expedite a response to your inquiry. Respectfully submitted,