HomeMy WebLinkAboutCT 00-06; BRESSI RANCH; RESULTS OF LABORATORY TESTS ON IMPORT CLASS 2 AGGREGATE BASE SAMPLES; 2004-05-13 (2)Leighton and Associates, Inc. A LEIGHTON GROUP COMPANY May 13, 2004 Project No. 971009-018 To: Lennar Communities 1525 Faraday Avenue, Suite 300 Carlsbad, California 92008 Attention: Ms. Kristine Zortman Subject: Results of Laboratory Tests on Import Class 2 Aggregate Base Samples Placed on Alverton Drive, Planning Area PA-6, Bressi Ranch, Carlsbad, California References: Caltrans, 1992, Standard Specifications, July 1992 Carlsbad, City of, 1996, Standards for Design and Construction of Public Works Improvements in the City of Carlsbad, California, Project No. 05332-12-01, dated April 20, 1993, revised December 10, 1996 In accordance with the requirements of the City of Carlsbad, we have performed laboratory tests on representative samples of the import Class 2 Aggregate Base (AB) material placed on a portion of Alverton Drive within Bressi Ranch Planning Area PA-6 located in Carlsbad, California. One representative sample of the Class 2 AB was sampled and transported to our laboratory. Laboratory tests performed on the representative sample included sand equivalent (in accordance with ASTM Test Method D2419) and sieve analysis (in accordance with ASTM Test Method C136). The results of the laboratory tests are presented on the attached table. Based on the City of Carlsbad requirements and the Caltrans specifications (Section 26-1.02A) as indicated on the tables, the representative Class 2 aggregate base sample met the city requirements. 3934 Murphy Canyon Road, Suite B205 • San Diego, CA 92123-4425 858.292.8030 • Fax 858.292.0771 • www.leightongeo.com 971009-018 Table 1 Laboratory Test Results of Import Class 2 Aggregate Base Material Alverton Drive Station No. 3+60 Sieve Analysis (in accordance with ASTM Test Method C136) Sieve Size Operating Range Required Percentage Passing* Sample Result In Conformance? 1 inch 100 100 Yes % inch 90-100 - 96 Yes No. 4 35-60 40 Yes No. 30 10-30 18 Yes No.200 2-9 1 6 Yes Sand Equivalent (in accordan e with ASIM Test Method D2419) Required Minimum* Sample Result In Conformance? 25 47 Yes *per Caltrans Standard Specifications Section 26 and City of Carlsbad Standard Special Provisions for Construction. If you have any questions regarding our letter, please contact this office. We appreciate this opportunity to be of service. Respectfully submitted, LEIGHTON AND ASSOCIATES, INC. -AW 1LJ< Randall K. Wagner, CEG 1612 Senior Associate Distribution: (2) Addressee Lennar Communities, Attention: Mr. Jim Urbina City of Carlsbad, Public Works Department, Attention: Mr. Casey Arndt (1) J. T. Kruer, Attention: Mr. Chuck Knight - 2 - Leighton