HomeMy WebLinkAboutCT 00-06; BRESSI RANCH; RESULTS OF LABORATORY TESTS ON PROPOSED IMPORT CLASS 2 AGGREGATE BASE SAMPLE; 2004-04-21croo-o Leighton and Associates, Inc. A LEIGHTON GROUP COMPANY April 21, 2004 Project No. 971009-017 To: Lennar Communities 1525 Faraday Avenue, Suite 300 Carlsbad, California 92008 Attention: Ms. Kristine Zortman Subject: Results of Laboratory Tests on Proposed Import Class 2 Aggregate Base Sample from the Camp Pendleton 3-mile Pit for the Bressi Ranch Project, Carlsbad, California References: Caltrans, 1992, Standard Specifications, July 1992 Carlsbad, City of, 1996, Standards for Design and Construction of Public Works Improvements in the City of Carlsbad, California, Project No. 05332-12-01, dated April 20, 1993, revised December 10, 1996 In accordance with the requirements of the City of Carlsbad, we have performed laboratory tests on a sample of the proposed import Class 2 Aggregate Base (AB) material from the Camp Pendleton 3-mile pit to be used on the backbone streets of the Bressi Ranch Project located in Carlsbad, California. One representative sample of the Class 2 AB being produced at the Camp Pendleton 3- mile pit was obtained and transported to our laboratory. Laboratory tests performed on the representative sample included sand equivalent (in accordance with ASTM Test Method D2419) and sieve analysis (in accordance with ASTM Test Method C136). The results of the laboratory tests are presented on Table 1. Based on the City of Carlsbad requirements and the Caltrans specifications (Section 26-1.02A) as indicated on Table 1, the representative Class 2 aggregate base sample met the city requirements. 3934 Murphy Canyon Road, Suite B205 • San Diego, CA 92123-4425 858.292.8030 • Fax 858.292.0771 • www.leightongeo.com Table 1 Laboratory Test Results Sieve Analysis (in accordance with ASTM Test Method C136) Operating Range Sieve Size Required Percentage Sample Result In Conformance? Passing* 1 inch 100 100 Yes 3/4 inch 90-100 97 Yes No. 4 35-60 57 Yes No. 30 10-30 28 Yes No. 200 1 2-9 7 Yes Sand Equivalent (in accordance with ASTM Test Method D2419) Required Minimum* Sample Result In Conformance? 25 48 Yes *per Caltrans Standard Specifications Section 26 and City of Carlsbad Standard Special Provisions for Construction. If you have any questions regarding our letter, please contact this office. We appreciate this opportunity to be of service. Respectfully submitted, LEIGHTON AND ASSOCIATES, INC. Randall K. Wagner, ~EGI612 Senior Associate Distribution: (2) Addressee Lennar Communities, Attention: Mr. Jim Urbina City of Carlsbad, Public Works Department, Attention: Mr. Casey Arndt (1) J. T. Kruer, Attention: Mr. Chuck Knight -2- Leighton